• Title/Summary/Keyword: Suppression criteria

Search Result 48, Processing Time 0.023 seconds

Quantitative Difference in the Extinguishing Concentration of Inert Gases with Fire Suppression Criteria in a Cup Burner Test (컵버너시험에서 소화기준에 따른 불활성기체의 소화농도에 대한 정량적 차이)

  • Cho, Jae-Ho;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.34-42
    • /
    • 2014
  • The concentrations of inert gases ($N_2$, Ar, $CO_2$ and He) required to induce the flame instabilities such as swing, rotation, lifted and blow-out were measured in a cup burner nonpremixed flames for $CH_4$ and $C_3H_8$ fuels. Quantitative differences in the extinguishing concentration with fire suppression criteria (i.e. blow-out or onset of flame instability) were also examined. It was found that the difference in extinguishing concentration was increased with the appearance of lifted flame and the low extinguishing performance of inert gaseous. The maximum difference in extinguishing concentration with the suppression criteria was approximately 35% at the highest fuel velocity condition (1.3 cm/s) for the $C_3H_8$-air nonpremixed flame. It can be also expected that the extinguishing concentration by the criteria based on the onset of flame instability will provide the useful information from the viewpoint of the accurate and economical design concentration.

DC-Suppression Selection Criteria of Multimode Modulation Code for Optical Recording (광 기록 시스템을 위한 멀티모드 변조 코드의 DC-억압 코드 선택 방법)

  • Lee, Myoung-Jin;Lee, Jun;Lee, Jae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3C
    • /
    • pp.209-214
    • /
    • 2003
  • Multi-mode coding method is a reliable DC-suppression method. There are two ways to improve the DC-suppression performance. One is improving scrambler's performance, and the other is improving selection criteria. The latter uses the MRDS(minimum running digital sum) criterion. It is easy to calculate, but its performance goes down when the length of codeword is getting longer. The MSW(mean squared weight) criterion that is known as the best so far regardless of the length of codeword has the high complexity. In this paper, we present the new selection criteria, MPRDS(minimum peak RDS) and A BSRDS(absolute RDS). Their performance are close to the MSW, implementation is simple. And also we present the SC(sign change) that has a subsidiary role with the original selection criteria and improve the capacity.

Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression (2유체 미세 물분무 소화노즐의 분무유동 특성)

  • Kim, Bong-Hwan;Choi, Hyo-Sung;Kim, Dong-Keon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

A study on the Water Mist Fire Suppression Performance (미세 물 분무 소화 성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.61-65
    • /
    • 2002
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility. The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was concluded to be cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

  • PDF

Numerical analysis to determine fire suppression time for multiple water mist nozzles in a large fire test compartment

  • Ha, Gaghyeon;Shin, Weon Gyu;Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1157-1166
    • /
    • 2021
  • In this study, a numerical sensitivity analysis was performed to determine the fire suppression time for a large number of water mist nozzles in a large fire compartment. Fire simulations were performed using FDS (Fire dynamics simulator) 6.5.2 under the same condition as the test scenario 5 of the International Maritime Organization (IMO) 1165 test protocol. The sensitivities of input parameters including cell size, extinguishing coefficient (EC), droplets per second (DPS), and peak heat release rate (HRR) of fuel were investigated in terms of the normalized HRR and temperature distribution in the compartment. A new method of determining the fire suppression time using FDS simulation was developed, based on the concept of the cut-off time by cut-off value (COV) of the heat release rate per unit volume (HRRPUV) and the cooling time by the HRR cooling time criteria value (CTCV). In addition, a method was developed to determine the average EC value for the simulation input, using the cooling time and cut-off time.

A Study on the Necessity and Contents of the Installation Criteria of the Fire Suppression Education & Training Facilities (화재진압 교육훈련시설 설치기준의 필요성 및 내용에 관한 연구)

  • Song, Woo Seung;Ham, Seung Hee;Yoon, Myung O
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.62-71
    • /
    • 2014
  • The importance of the firefighting education & Training is being magnified in order to enhance and strengthen a firefighters' ability and to reduce the firefighters' fatality and casualty. Therefore, It is needed to expand the facilities. In this study, with a comparative analysis of the global firefighting education & training facilities for fire suppression, we try to present the necessity and the basic contents of the establishing the installation criteria for the domestic firefighting education & training facilities. It has to contain specific purpose of the training and minimum standards for the structures with a guarantee of an international level. Naturally, the top priority is a safety of trainees and trainers. And, it should pay attention to a higher effectivity of the training course with a active reflection of the standard operation procedures' scenarios. Simultaneously, by securing a similarity and a compatibility to the other standards, it must maintain the balance of a whole standard.

Scaling analysis of the pressure suppression containment test facility for the small pressurized water reactor

  • Liu, Xinxing;Qi, Xiangjie;Zhang, Nan;Meng, Zhaoming;Sun, Zhongning
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.793-803
    • /
    • 2021
  • The small PWR has been paid more and more attention due to its diversity of application and flexibility in the site selection. However, the large core power density, the small containment space and the rapid accident progress characteristics make it difficult to control the containment pressure like the traditional PWR during the LOCA. The pressure suppression system has been used by the BWR since the early design, which is a suitable technique that can be applied to the small PWR. Since the configuration and operating conditions are different from the BWR, the pressure suppression system should be redesigned for the small PWR. Conducting the experiments on the scale down test facility is a good choice to reproduce the prototypical phenomena in the test facility, which is both economical and reasonable. A systematic scaling method referring to the H2TS method was proposed to determine the geometrical and thermohydraulic parameters of the pressure suppression containment response test facility for the small PWR conceptual design. The containment and the pressure suppression system related thermohydraulic phenomena were analyzed with top-down and bottom-up scaling methods. A set of the scaling criteria were obtained, through which the main parameters of the test facility can be determined.

A Study on the Performance of Water Mist Spray Fire Protection System (미세물분무 소화성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱;최현호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.572-578
    • /
    • 2003
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was attributed to the cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

Performance Evaluation of DC-Suppression GS Coding for the Holographic Data Storage Using Integer Programming Models (정수계획법 모형을 이용한 홀로그래픽 저장장치의 DC-억압 GS코딩의 성능평가)

  • Park, Taehyung;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.8
    • /
    • pp.650-655
    • /
    • 2013
  • For the DC-free encoding of source data, the Guided Scrambling (GS) technique is widely used as multi-mode coding in the optical data storage system. For DC-suppression GS coding in the holographic data storage system, the conservative array and balanced coding criteria are proposed. In this paper, equivalent integer programming models are developed to determine the optimal control bits for the minimum digital sum value (MDSV), conservative array, and balanced coding criteria. Using the proposed integer programming models, we compare the performance of GS encoding for the various combination of control bit/array sizes and scrambling polynomials.

Progressive Sampling Implementing Different Criteria (밀도증가식(密度增加式) 표본추출법(標本抽出法)에 관한 연구(研究) - 추출조건(抽出條件)을 중심(中心)으로 -)

  • Lee, Suk Chan;Cho, Kyu Jon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.101-107
    • /
    • 1982
  • The progressive sampling method adapts well to the local variabilities of the input terrains, and is therefore one of the most efficient sampling methods in DTM. The efficiency of progressive sampling can be enhanced by increasing the comprehensiveness of grid densification criteria, with superfluous points reduced and/or suppressed. In this investigation, four different criteria were applied to the numerical test, and the suppression criterion was found the most significant among them.

  • PDF