• 제목/요약/키워드: Supply water temperature

검색결과 536건 처리시간 0.03초

상수도의 수질관리와 타소소독의 잔류효과에 관한 연구 (Study on the Water Quality Control of Water Supply the Reside: Effects of Chlorinations)

  • 유귀현
    • 환경위생공학
    • /
    • 제6권2호
    • /
    • pp.33-47
    • /
    • 1991
  • 1. Water supply treatment plants personnel could not test the water quality control, because most of them rely on the provincial health laboratories about water quality rely rant test. However, in future, plants have to been provided the facilities and equipment of water quality laboratory. 2. Chlorination methods are 89.5% of liquid chlorine and 10.5% of solid chlorine, and the cost per 1 $\m^{3}$ of chlorination is about 1.30 won which chlorination cost is very cheap as 1/142 of drinking water production cost. Input method of chlorine is 35% of automatic method, 56% of semi-automatic, and 9% of other methods, and this is no problem 3. Residual effects of chlorination, in the case of distilled water as a standardized material and 0.2 ppm of seperated residual chlorine, were continued 32 hours in $0^{\circ}C$, and 25 hour in $20^{\circ}C$, of water temperature and in the case of 0.4 ppm of seperated residual chlorine were continued 47 hours in $0^{\circ}C$ and 23 hours in $20^{\circ}C$. 4. In the case of 4 ppm of seperated residual chlorine, residual effects were continued 23 hours in $5^{\circ}C$, 90 hours in $10^{\circ}C$, 78 hours in $15^{\circ}C$, and 60 hours in $20^{\circ}C$ : by the temper; lure of water, continuing residual effects of chlorination are different, so we have to car for the warm season chlorination in the hider temperature. 5. Chlorination effects of drinking waters in the case of 0.4 ppm of seperated residual chlorine were continued 237 hours in $22^{\circ}C$ water : and in the case of rechlorination as 4 ppm of residual chlorine, continued 71 hours in $22^{\circ}C$ water.

  • PDF

Ecological Characteristics of Lycoris radiata with Habitat Types

  • Lee, Jeom-Sook;Ihm, Byung-Sun;Kim, Ha-Song
    • The Korean Journal of Ecology
    • /
    • 제26권5호
    • /
    • pp.247-250
    • /
    • 2003
  • The investigation of ecological characteristics of Lycoris radiata was carried out in flooding (site I), half flooding (site II) and dry stands (site III). Seasonal change of air temperature showed similar patterns and that of light intensity showed quite difference among three L. radiata stands. Seasonal change of soil water content showed a great difference among three L. radiata stands. The study area was dominated by Pinus densiflora, P. thunbergii and L. radiata communities. The number of bulb in 1. radiata increased in September with bulb formation and decreased in January. Bulb weight in L. radiata was different from each site. The numbers of blossom were 23, 13 and 9, respectively in site I, II and III. The length of wreath were 17.0, 13.0 and 11.0cm, respectively, the length of stamen were 7.0, 6.4 and 6.5 cm, respectively and the length of stalk were 60.0, 45.0 and 42.0 cm, respectively in site I, II and III. The leaf of L. radiata developed rapidly in site I with sufficient water supply and lower light intensity, the number and the length of rootlets increased considerably in site III with insufficient water supply and higher light intensity, and the ecological characteristics in site II was intermediate between site I and site III. There was no great difference between the numbers of rootlets in site I and site II, which were due to sufficient water supply in two stands.

고온환경에서 이온수의 급수가 산란계의 생산성, 계란 품질 및 혈액성상에 미치는 영향 (Effects of Drinking Ion Water on Performance, Egg Quality and Blood Biochemical Composition of Laying Hens under High Temperature Conditions)

  • 임천익;레이나마수드;리홍룡;조태현;류경선
    • 한국가금학회지
    • /
    • 제47권3호
    • /
    • pp.121-126
    • /
    • 2020
  • 본 연구는 고온환경에서 이온수의 급수가 산란계의 생산성, 계란 품질 및 혈액성상에 미치는 영향을 구명하고자 시행하였다. 24주령 산란계 180수를 3개 처리구 5반복으로 배치하여 4주간 사양실험을 실시하였다. 각 처리구는 수돗물(tap water; TW)과 냉수(cold water; CW)를 급수하고, 이온수 급수구(ion water; IW)와 비교하였다. 산란계의 생산성은 산란율과 난중을 매일 조사하여 계산하였고, 계란 품질과 혈액성상은 사양실험 종료 후 채집하여 분석하였다. 고온환경에서 이온수 급수로 일반 수돗물에 비해 산란율, 난중 및 사료섭취량은 유의적으로 개선되었고(P<0.01), 계란의 난백 높이와 호우유닛 및 난각 두께도 증가하였다(P<0.05). 혈액성상에서 칼슘과 인은 이온수 급수구에서 증가하는 경향을 보였고(P<0.10), HDL 콜레스테롤과 알부민은 이온수 급수구에서 수돗물에 비해 통계적으로 증가하였다(P<0.05). 본 실험 결과 이온수 급수로 여름철 산란계의 고온스트레스를 완화되었다. 특히 이러한 이온수가 혹서기에 산란계에 미치는 영향은 냉수를 급수한 결과와 유사하였으므로 냉수 급수법과 함께 산란계에 활용될 수 있는 여름철 음용수 관리법으로 가능성을 보였다.

기후변화에 따른 기업 공급체인의 물 리스크 대응 실태 조사 (A study of how Supply Chain companies correspond to water risk resulted from climate change)

  • 박지영;박석하;임병선;김제숭
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.149-168
    • /
    • 2015
  • It is expected that the temperature in Pyeongyang will be similar to that ($16.6^{\circ}C$) in Seogwipo in the late 21st century, and most of South Korea will enter the subtropical climate due to climate change. Change in the precipitation pattern like the range of fluctuation caused by climate change will lead to expanded uncertainty in securing reliable water supply, along with a serious impact on demands for living and industrial water due to change in the volume and period of river outflow. As industrial water for production activities is estimated based on the contract quantity, it is difficult to apply rationalization of water usage and incentives in water recycling. Therefore many companies are making efforts in complying with the effluent standard while spending few resources on such rationalization and recycling. This study researched water risk management over 115 Korean companies by 28 questions in 4 categories. Through the research, this study aims to understand water risk management levels and seek response plans.

이앙시기 및 담수심 변화에 따른 논벼 수요량 변화 분석 (Analysis of Variance of Paddy Water Demand Depending on Rice Transplanting Period and Ponding Depth)

  • 조건호;최경숙
    • 한국농공학회논문집
    • /
    • 제63권3호
    • /
    • pp.75-85
    • /
    • 2021
  • This study evaluated variations in the paddy rice water demand based on the continuous changing in rice transplanting period and ponding depth at the four study paddy fields, which represent typical rice producing regions in Korea. Total 7 scenarios on rice transplanting periods were applied while minimum ponding depth of 0 and 20 mm were applied in accordance with maximum ponding depth ranging from 40 mm to 100 mm with 20 mm interval. The weather data from 2013 to 2019 was also considered. The results indicated that the highest rice water demand occurred at high temperature and low rainfall region. Increased rice transplanting periods showed higher rice water demand. The rice water demand for 51 transplanting days closely matched with the actual irrigation water supply. In case of ponding depth, the results showed that the minimum ponding depth had a proportional relationship with rice water demand, while maximum ponding depth showed the contrary results. Minimum ponding depth had a greater impact on rice water demand than the maximum ponding depth. Therefore, these results suggest that increasing the rice transplanting period, which reflects the current practice is desirable for a reliable estimation of rice water demand.

수온, 염분, 사육밀도 및 먹이공급이 왕우럭(Tresus keenae) 유생의 성장과 생존에 미치는 영향 (Effects of Water Temperature, Salinity, Rearing Density and Food Supply on the Growth and Survival of the Surf Clam, Tresus keenae Larvae)

  • 강한승;김철원
    • 한국해양생명과학회지
    • /
    • 제3권2호
    • /
    • pp.67-73
    • /
    • 2018
  • 본 연구는 수온, 염분, 사육밀도 및 혼합 먹이생물 공급량과 같은 환경요인이 왕우럭 Tresus keenae의 유생사육 시 생존 및 발생에 미치는 영향을 조사하기 위하여 수행하였다. 연구 결과, 왕우럭 유생사육의 최적 조건은 수온 20℃에서 24℃, 염분 30 psu, 사육밀도 1 ml당 5개체 및 먹이생물 I. galbana, C. simplex 및 T. suecica 혼합 공급량 10×104 세포/ml이였다. 본 연구 결과를 통해 밝혀진 왕우럭 유생 최적의 사육 환경요인은 빠른 성장 및 높은 생존을 통해 생산성 향상에 기여하리라 생각된다.

Occurrence of Disinfection By-Products and Distribution in Drinking Water

  • In, Chi-Kyung;Lee, Jung-Ho;Lee, In-Sook
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 Proceedings of KSEH.Minamata Forum
    • /
    • pp.103-114
    • /
    • 2005
  • Chlorine disinfection has been used in drinking water supply to disinfect the water-borne microbial disease which may cause to serious human disease. As Chlorination is still the least costly, relatively easy to use, chlorination is the primary means to disinfect portable water supplies and control bacterial growth in the distribution system. However, chlorine also reacts with natural organic matter (NOM), which presents in nearly all water sources, and then produces disinfection by-product (DBps), which may have adverse health effects. Although the existent DBPs have been reported in drinking water supplies, it is not feasible to predict the levels of the various DBPs due to the complex chemistry reaction involved. The objectives of this study were to investigate seasonal variation of DBPs formation and difference of DBPs concentration in the plant to tap water. The average concentration of THMs was 20.04 ${\mu}g/{\ell}$, HAAs 8-15 ${\mu}g/{\ell}$, HANs 2-4.5 ${\mu}g/{\ell}$ respectively. Distant variation of DBPs formation is that THMs concentration increase by 17% at 2 km point from the plant and by 28% at 7 km and HAAs, HANs also increase each by 16%, 32%, at 2 km from the plant and 35%, 56%, at 7 km. DBPs increase in water supply pipe continually. The seasonal occurrence of DBPs is that in May and August DBPs concentration is very high then in March, in May DBPs concentration is highest. The temperature is main factor of DBPs formation, precursor also. Precursor which was accumulated for winter flowed into the raw water by flooding in spring and summer and produced DBPs. Therefore for the supply of secure drinking water, it is required to protect precursor of flowing into raw water and to add to BCAA and DBAA to drinking water standards.

  • PDF

저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구 (Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System)

  • 조진균;박병용;이용준;정원호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

Solar Energy를 이용한 하수처리의 질소 제거에 관한 연구 (A Study on Removal of Nitrogen at Sewage Treatment using Solar Energy)

  • 황용하
    • 융복합기술연구소 논문집
    • /
    • 제1권2호
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this research is to improve nitrogen removal efficiency in winter season through rise of water temperature of extraneous water by using solar energy which is estimated to have great potential among new regeneration energy and while operating Plug-Flow Reactor to improve nitrogen removal efficiency by selecting A/O process among sewage waste water treatment processes as the necessity of solving the problem of nitrogen removal efficiency according to reduced water temperature in winter season and strengthening of water quality criteria regarding discharged sewage waste water suggested in the research background. Summarizing the research result, supply of solar energy source improves the function outstandingly when removing nitrogen, (nitrogen removal rate before operating solar energy 55.4% ${\rightarrow}$ nitrogen removal rate after operating solar energy 84.1%).

  • PDF

심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석 (Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater)

  • 정훈;황성욱;이철희
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.