• Title/Summary/Keyword: Supply valve

Search Result 292, Processing Time 0.033 seconds

The Study of the Decision Criteria for the Urgency Released Valve in Hydraulic Dam (수력댐 비상방류밸브의 선정조건에 관한 연구)

  • Roh, H.W.;Lee, G.S.;Park, Y.M.;Kim, B.S.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.613-616
    • /
    • 2005
  • In general, the hollow jet valve, the fixed cone valve had been used for the urgency released or maintenance of the flow rate. Nowadays, the butterfly valve, the gate valve are applied in economic performance and operation maintenance more than the hollow jet valve, the fixed cone valve. However, in the case of butterfly valve, it should be required the strict application standard to the cavitation coefficient because the structural axis and disk were situated in pipe channel and the occurring the shock problem by Karman Vortex. And, the judgment data for choice were slight lowdown in water supply and drainage facilities standard or Japanese penstock technology standard, various standard of KOWACO etc. Therefore. there were investigated the valve inside phenomenon (cavitation, disk chattering, vibration) by velocity of flow and the stability examination of body by high velocity of flow through flow scale model test using the numerical analysis and PIV to establish the applicable extensibility of the butterfly valve for the urgency released valve.

  • PDF

Development of an Automatic Nutrient-Solution Supply System Using Fuzzy Control (퍼지제어를 이용한 양액 자동공급 시스템 개발)

  • 황호준;류관희;조성인;이규철;김기영
    • Journal of Biosystems Engineering
    • /
    • v.23 no.4
    • /
    • pp.365-372
    • /
    • 1998
  • This study was carried out to develop a nutrient-solution mixing-and-supplying system, which used a low-cost metering device instead of expensive metering pumps and a fuzzy logic controller. A low cost and precise overflow-type metering device was developed and evaluated by testing the flow discharge for the automatic nutrient-solution mixing-and-supplying system for snail-scale hydroponic sewers. The fuzzy logic controllers, which could predict and meet the desired values of EC and supply rate of nutrient solution were developed and verified by simulation and experiment. this fuzzy logic controller, whose algorithm consists of four crisp inputs, two crisp outputs and nine rules, was developed to predict the desired value of EC and supply rate of nutrient solution and two crisp inputs, one crisp output and nine rules used to control EC to the desired values. The nutrient-solution mixing-and-supplying system showed satisfactory EC control performance with the maximum overshooting of 0.035 mS/cm and the maximum settling time of 15 minutes in case of increasing 0.7 mS/cm. also, the accuracy of the overflow-type metering device in terms of the full-scale error was 2.29% when using solenoid valve only and 0.2% when using solenoid valve and flow control valve together.

  • PDF

Experimental Study of Operating Parameters for Pneumatic Control Valve in Abnormal Conditions (공기구동 제어밸브 비정상상태 운전변수에 관한 실험적 연구)

  • Kim, Yang-seok;Kim, Dae-woong;Lee, Byoung-oh;Jeoung, Rae-hyuk;Lee, Seung-ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.613-619
    • /
    • 2016
  • A pneumatic control valve performs a major role in controlling the flow of a system or the level of a key tank in many power plants, and its performance should be guaranteed during the plant's lifetime. Its operation starts by supplying air to the pneumatic actuator or by exhausting the air from the actuator. To control the valve position, the amount of air supply or exhaust is adjusted by a control loop where various accessaries are equipped. In this paper, air leakage in the air supply line, changes in the valve packing force, and false adjustments of zero and the span of the positioner are simulated and analyzed using a 2-in pneumatic valve with a position control loop including an I/P converter and positioner, where the valve position is controlled within ${\pm}2%$ of the control pressure at 67% opening position.

Structural safety evaluation of decrepit gray cast iron water valves for the control of water supply (노후 회주철 수도용 제수밸브의 구조적 안전성 평가)

  • Lee, Ho-Min;Choi, Tae-Ho;Park, Jeong-Joo;Bae, Cheol-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.5
    • /
    • pp.261-273
    • /
    • 2022
  • In this study, we collect water control valves that have had accidents due to existing cracks, etc. are collected, and propose investigation items for strengthening the valve structural safety evaluation through a series of analyzes from valve specifications to physicochemical properties are proposed. The results of this study are as follows. First, there was a large variation in the thickness of the body or flange of the valves to be investigated, which is considered to be very important factor, because it may affect the safety of the valve body against internal pressure and the flange connected with the bolt nut. Second, 60% of the valves under investigation had many voids in the valve body and flange, etc. and the decrease in thickness due to corrosion was relatively large on the inner surface in contact with water rather than the outer surface. It is judged that the investigation of depth included voids is very important factor. Third, all valves to be investigated are made of gray cast iron foam, and therefore it is judged that there is no major problem in chemical composition. It is judged that the chemical composition should be investigated. Fourth, as a physical investigation item, the analysis of metal morphology structure seems to be a very important factor for nodular cast iron from rather than a gray cast iron foam water valve with a flake structure. As it was found to be 46.7~68.8% of the standard recommended by KS, it could have a direct effect on damage such as cracks, and therefore it is judged that the evaluation of tensile strength is very important in evaluating the safety of the valve.

Flow Characteristics of Pressure Balancing Valve with Various Piston Shapes (피스톤 형상변화에 따른 압력평형밸브의 유동특성연구)

  • Kim, Tae-An;An, Byeong-Jae;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2168-2173
    • /
    • 2003
  • Pressure balancing valve is one of important control devices, which is fully automatic and no manual controls, regulating or adjustments are needed. It is typically used to maintain constant temperature of working fluid in power and chemical plants and domestic water supply systems. Pressure balancing valve is composed of body, cylinder and balancing piston. Therefore, the balancing piston shapes are important design parameters for a pressure balancing valve. In this study, numerical and experimental analyses are carried out with two different balancing piston shapes. Especially, the distribution of static pressure is investigated to calculate the flow coefficient($C_v$). The governing equations are derived from making using of three-dimensional Navier-Stokes equations with standard ${\kappa}-{\varepsilon}$ turbulence model and SIMPLE algorithm. Using commercial code, PHOEIC, the pressure and flow fields in pressure balancing valve are depicted.

  • PDF

Study of Waterhammer Suppression Technique due to Valve Closing on Water Supply Pipeline (송수관로 밸브폐쇄에 따른 수충격현상 완화기법 연구)

  • Park, Jong-Ho;Park, Han-Yung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.6
    • /
    • pp.11-17
    • /
    • 2011
  • The cause of waterhammer phenomenon due to valve closing which is installed on pipeline is clarified in this study. Also if waterhammer phenomenon occurs on simple pipeline, expensive facilities like pressure relief valve is adapted to protect pipeline from waterhammer so far. But this study shows that waterhammer phenomenon can be suppressed by just simple modification of valve control sequence, and this technique is verified by simulation and site experiment.

Flow Control for High Pressure Gas by using a Solenoid Valve (솔레노이드 밸브를 이용한 고압가스의 유량제어)

  • Sim Han-sub;Lee Chi-woo;Kim Nam-kyung;Ahn Kook-chan;Namkoong Chai-kwan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.156-161
    • /
    • 2005
  • Dynamic flow characteristics of a solenoid valve are affected by pressure difference in inlet and outlet of orifice, gas temperature, and supply voltage of a coil. In this paper, the dynamic flow characteristics for deviations of various conditions are studied Static and dynamic flow for variation on-time of a solenoid valve open signal are measured in basic bench test. The solenoid valve is applied to a compressed natural gas(CNG) engine test for validation of flow control performance. The experimental results show that flow of high pressure gas can controlled precisely by using a solenoid valve.

  • PDF

Application & Examination of the Plan for Optimum Stability through Water-hammer in Pipe Line and Booster Pump Station (관로계통 및 가압펌프장 수격에 따른 최적 안정성 확보방안)

  • Ra, Beyong-Pil;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.19-24
    • /
    • 2009
  • This paper is performed to find out the stability of water-hammer in pipe line and pump station that is happened when additional water needs demanded. At first, the water supply construction project is planned to supply $6,000\;m^3/day$ through 17.9 km pipe line. But additional demand ($1,200\;m^3/day$) happened from Cheong-ra water reservoir. In this situation, air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) are needed to prevent water-hammer. When the additional water is supplied, the existing facilities (air-chamber, vacuum breaker valve) are sufficient to alleviate shock not changing capacity alteration, judging from the airspace change and rise. Therefore, there is no problem for water-hammer by installing air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) at the top of Yeo-ju hill.