• Title/Summary/Keyword: Supply rate

Search Result 2,631, Processing Time 0.031 seconds

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Assessment of the Effect of Dimethyl Ether (DME) Combustion on Lettuce and Chinese Cabbage Growth in Greenhouse (온실에서 상추와 배추를 이용한 DME 원료 난방 효율분석)

  • Basak, Jayanta Kumar;Qasim, Waqas;Khan, Fawad;Okyere, Frank Gyan;Lee, Yongjin;Arulmozhi, Elanchezhian;Park, Jihoon;Cho, Wonjun;Kim, Hyeon Tae
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.293-301
    • /
    • 2019
  • The experiment was conducted to determine the performance of DME combustion gas when used as a fuel for DME burner for raising temperature and $CO_2$ concentration in greenhouse and also to examine its effects on chlorophyll content, and fresh and dry weight of lettuce and Chinese cabbage. DME-1 and DME-2 treatments consisted of average DME flow quantity in duct were $17.4m^3min^{-1}$ and $10.2m^3min^{-1}$ respectively to greenhouse-1 and greenhouse-2 and no DME gas was supplied to greenhouse-3 which was left as control (DME-3). DME supply times were $0.5hr\;day^{-1}$, $1hr\;day^{-1}$, $1:30hrs\;day^{-1}$ and $2hrs\;day^{-1}$ on week 1, 2, 3, and 4 respectively. Chlorophyll content and fresh and dry weight of lettuce and Chinese cabbage were measured for each treatment and analyzed through analysis of variance with a significance level of P<0.05. The result of the study showed that $CO_2$ concentration increased up to 265% and 174% and the level of temperature elevated $4.8^{\circ}C$ and $3.1^{\circ}C$ in greenhouse-1 and 2, respectively as compared to greenhouse-3 due to application of DME combustion gas. Although, the same crop management practices were provided in greenhouse-1, 2 and 3 at a same rate, the highest change (p<0.05) of chlorophyll content, fresh weight and dry weight were found from the DME-1 treatment, followed by DME-2. As a result, DME combustion gas that raised the level of temperature and $CO_2$ concentration in the greenhouse-1 and greenhouse-2, might have an effect on growth of lettuce and Chinese cabbage. At end of experiment, the highest fresh and dry weight of lettuce and Chinese cabbage were measured in greenhouse-1 and followed by greenhouse-2. Similarly chlorophyll content of greenhouse-1 and greenhouse-2 were more compared to greenhouse-3. In general, DME was not producing any harmful gas during its combustion period, therefore it can be used as an alternative to conventional fuel such as diesel and liquefied petroleum gas (LPG) for both heating and $CO_2$ supply in winter season. Moreover, endorsed quantify of DME combustion gas for a specified crop can be applied to greenhouse to improve the plant growth and enhance yield.

Structural Changes in Rental Housing Markets and a Mismatch between Quartile Income and Rent (월세 임차시장의 구조적 변화에 따른 분위별 소득과 임대료 간의 부정합 분석)

  • JungHo Park;Taegyun Yim
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.17-37
    • /
    • 2023
  • The rental housing market in South Korea, specifically monthly rent with deposit, has been expanding over the last three decades (8.2% in 1990 to 21.0% in 2020), partly replacing the traditional Jeonse market. The distribution of rent has changed due to public rental subsidies and the emergence of luxury rental housing, while the distribution of rental household income has been polarized because of the emergence of rich renters. This study attempts to measure the structural changes in the rental market by developing a new indicator of income-rent mismatch. Using the seven series of the Korea Housing Survey, this study analyzed the changes in rent (reflecting the conversion rate) and income levels of rental households in 2006 (base year) and 10-15 years later (the analysis year) at the national level and at the spatial unit of 16 metropolitan cities and provinces (excluding Sejong), respectively, by dividing them into quartile data. The result reveals that rental housing was undersupplied in middle- and high-income rental housing due to the decline in the highest quartile (25%→18%) and the third quartile groups (25%→20%), while the supply of public rental housing expanded for the second quartile (25%→28%) and the lowest quartile (25%→35) groups. On the demand side, the highest income quartile shrank (25%→21%), while the lowest income quartile grew (25%→31%). Comparing the 16 metropolitan cities and provinces, there were significant regional differences in the direction and intensity of changes in rent and renter household income. In particular, the rental market in Seoul was characterized by supply polarization, which led to an imbalance in the income distribution of rental households. The structural changes in the apartment rental market were different from those in the non-apartment rental market. The findings of this study can be used as a basis for future regional rental housing markets. The findings can support securing affordable rental housing stock for each income quartile group on monthly rent and developing housing stability measures for a balance between income and rent distribution in each region.

Water Physiology of Panax ginseng. 1. Habitat observation. cultural experience, weather factors and characteristics of root and leaf (인삼의 수분생리 1. 자생지관찰.재배 경험.기상요인과 근 및 엽의 특성)

  • Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.4 no.2
    • /
    • pp.197-221
    • /
    • 1980
  • Habitat observation, cultural experience of old and present plantation, weather factors in relation to crop stand and water physiology of root and leaf were reviewed. According to habitat observation ginseng plants love water but plate wit talus well grow at drained place with high moisture content in air and soil while ginseng plants were not found in dry or wet place. According to cultivation experience ginseng plants require abundant water in nursery and main field but most old planters believe that ginseng plaints are draught-loving thus require little water. The experience that rain especially in summer i.e unfavorable might be due to mechanical damage of leaves arid leaf disease infection, or severe leaf fall which is caused by high air temperature and coinsided with rain. According to crop stand observation in relation to weather factors abunsant water increased each root weight but decreased total yield indicating tile increase of missing root rate. Rain in summer was unfavorable too. Though rain in June was favorable for high yield general experience that cloudy day and rain were unfavorable might be due to low light intensity under shade. Present leading planters also do loot consider the importance of water in main field. Water content is higher in top than in root and highest in central portion of root and in stem of top. For seedling the heavier the weight of root is tile higher the water content while it reveries from two years old. Water potential of intact root appeared to be -2.89 bar suggesting high sensitivity to water environment. Under water stress water content severly decreased only in leaf. Water content of leaf appeared to be 78% for optimum, below 72% for functional damage and 68% for perm anent wilting. Transpiration or curs Principally through stomata in lower side of leaf thus contribution of upper side transpiration decreased with the increase of intensity. Transpiration is greater in the leaves grown under high light intensity. Thus water content is lower with high light inte nsity under field condition indicating that light is probable cause of water stress in field. Transpiration reached maximum at 10K1ut The decrease of transpiration at higher temperature seems to be due to the decrease of stomata aperture caused by water stress. Severe decrease of photosynthesis under water stress seems to be principally due to functional damage which is not caused by high temperature and Partly due to poor CO2 supply. Water potential of leaf appeared to be -16.8 bar suggesting weakness in draught tolerance. Ginseng leaves absorb water under high humidity. Water free space of leaf disc is %mailer than that of soybean leaf and water uptake appears to be more than two steps.

  • PDF

On the Countermeasure for Preventing the Accident of Cargo Handling in Port (항만하역관할의 원인분석 및 예방대책에 관하여)

  • 박용욱;이철영
    • Journal of the Korean Institute of Navigation
    • /
    • v.17 no.3
    • /
    • pp.57-68
    • /
    • 1993
  • The economy of Korea has grown up significantly in its scale. It has, therefore, become imperative to develop countermeasures to prevent work related injuries and occupational illnesses resultining from haza-rdous working conditions and handling harmful substances. A lot of cargo handling accident in port have occurred due to the characteristics of poor working environment, diversity of working place and method, fluctuation of the amount of cargo and handling of heavy, long, harmful and dangerous cargo, etc. According to '91 industrial accident analysis carried out by the ministry of labour, the number of the stevedores injured by cargo handling accident in port were 1, 432 persons (the death accident : 22 per-sons), the amount of industrial accident compensation in port was 6.7 billion won (the amount of economic loss : 33.6 billion won), and the injury occurance rate of the stevedoring industry was higher than that of the whole industry. This paper, therefore, aims to the actual status of the stevedoring industry and to extract the main cau-ses of the accidents related to cargo handling in port through factor analysis using the data of the accide-nts in the whole habour from 1990 to 1992, and to suggest the countermeasures to prevent such accident. The main causes of the accident and countermeasures are found to be as follows through the factor analy-sis : Factor1, factor2, and factor3 related to a defect of human being and management, a defect of state and environment, and an insufficiency of education and law are extracted. The short-term countermeasures to prevent these accidents are 1) to consolidate the safety and health organization in the working spot, 2) to secure a safe condition in working spot before dock work, 3) to strengthen a dock worker's safety educa-tion. The long-term countermeasures are 1) to promote a decasualisation of dock workers, 2) to modernize the cargo working methods through constructing exclusive pier and introducing exclusive cargo handling equipment, 3) to establish a exclusive dock accident prevention organization and the dock workers law. Factor 4, factor5, factor6, and factor7 related to an unfitness, a deficiency of technical knowledge, a nonfu-lfilment of safety measures, and a bad arrangement are extracted. The countermeasures to prevent these accidents are 1) to perform a complete safety inspection of cargo handling equipments and tools and to carry out the dock work according to a working plan, 2) to publish and supply technical safety books, safety instruction book, safety check list, etc., 3) to strengthen the safety patrol at the working spot in habour and to activate a safety fund, 4) to maintain always a clean workshop with the safety consciousness in which the good arragement of the working spot is considered to be the beginning of safety.

  • PDF

Appraisal of Concrete Performance and Plan for Stable Use of EAF Oxidizing Slag as Fine Aggregate of Concrete (전기로 산화슬래그 잔골재를 사용한 콘크리트의 성능 평가)

  • Cho, Bong-Suk;Lee, Hoon-Ha;Yang, Seung-Kyu;Lee, Woong-Jong;Um, Tai-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.367-375
    • /
    • 2009
  • Recently, more focus is shift to imbalances in aggregate market supply and demand and an exhaustion of natural resources. In this situation, Electric arc furnace oxidizing slag (EAF slag) has high application possibility as aggregate for concrete due to similar property with general aggregate. However, it is inherent the problem which causes pop-out by free-CaO contained in slag In this study, we've got the plan to assure the chemical stability of EAF slag, and then experimentally tested the mechanical performance and durability for the fine aggregate used EAF slag. On this test result, we suggest the application plan. At the result of this study, it shows that EAF slag would reduce the surface defect such as pop-out due to natural aging for the fixed hour and adjustment the grain size of EAF slag. And mechanical performance and durability according to the replacement rate of concrete service, were revealed more than equal or equal compare to general aggregate. Hereafter, quality control must precede not to impede the beauty of concrete surface as assure the safety for aging and processing. And, to establish the environmental resource recycling system for by-products of steel, it should be made development of various application and guideline of quality control for the EAF slag aggregate. Moreover, it must be constantly studied all kind of engineering performance and durability for related to this study.

Selection of Retaining Wall System for Underground Parking Lots Expansion of Apartments (거주중 공동주택의 지하주차장확대를 위한 흙막이공법 선정)

  • Ro, Young-Chang;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.2
    • /
    • pp.99-107
    • /
    • 2008
  • Rapidly increasing automobile supply rate according to improved economic level of life makes lack of parking space of apartments. Even though the initial design of parking space compiled with old regulations, it may not observe either new laws or requirement of inhabitants. Even if old apartments have no structural durability problem, outworn facilities and insufficient parking area may be a main reason for reconstruction. It causes waste of national resources and makes recycling issues. Additionally, irregularly parked cars make traffic obstruction to a fire engine and result in many fire accident victims. Parking problems of apartments are not only inconvenience but also serious safety issues. From these points of view, remodeling only for parking area expansion is necessary to avoid overall reconstruction of apartments. The purpose of this study is to suggest a retaining wall selection method for apartments underground parking lots expansion without evacuation of resident people. Effect factors to select retaining wall system are analyzed and weight values are calculated by applying AHP. One selection method of retaining wall is proposed by evaluating applicability and its sensitivity analysis is executed. This selection method is expected to help decision-making of retaining wall system selection.

Efficiency of Enriched Rotifer and Artemia nauplius for the Seedling Production of Flounder, Paralichthys olivaceus (넙치 종묘생산을 위한 Rotifer와 Artemia nauplius의 영양강화효과)

  • LIM Young Soo;HUR Sung Bum
    • Journal of Aquaculture
    • /
    • v.7 no.4
    • /
    • pp.225-237
    • /
    • 1994
  • Survival and growth rates of flounder larvae fed rotifers and Artemia nauplii enriched by various bio-enrichment techniques were investigated. Enriched materials used in the study were $12\omega-yeast$, 2 commercial emulsified oil and microparticulated products. $\omega-yeast$ were added with one kinds of oils (cuttlefish liver oil, sardine oil, Alaska pollock liver oil, linseed oil) at the level of $5\%,\;15\%\;and\;25\%$. The results are as follows: 1. The growth rate of rotifers cultured with $\omega-yeast$ added $15\%$ cuttlefish liver oil was the best among 12 kinds of $\omega-yeast$ and this performance was almost the same with that of rotifers fed on Chlorella. 2. Survival and growth rates of flounder larvae fed on rotifers and Artemia nauplii enriched with $\omega-yeast$ and the other commercial products were higher than that those of larvae cultured with only Chlorella and non-enriched Artemia. The optimum contents of the cuttlefish liver oil in $\omega-yeast$ for rotifers and Artemia enrichment were $15\%\;and\;25\%$, respectively. 3. Optimum enrichment time and supply amount of $\omega-yeast$ for Artemia nauplii were 6 hr., 1.5 g/g cyst, respectively.

  • PDF

A Case of Chemical Pneumonitis Caused by Nitric Acid Fume Inhalation (질산(Nitric Acid) 증기 흡입에 의해 발생한 화학성 폐렴 1예)

  • Ha, Jun-Wook;Lee, Seung Soon;Eom, Kwang-Seok;Bahn, Joon-Woo;Jang, Seung Hun;Kim, Dong Gyu;Lee, In Jae;Lee, Yul;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.670-676
    • /
    • 2004
  • Chemical pneumonitis is caused by the inhalation of noxious chemical substances and is a cause of occupational lung disease. Nitric acid, which is a one of the common air pollutants and a potential oxidant for refining and cleansing of metals, has a chance for occupational and environmental exposure. A 52-year-old man visited our hospital due to coughing and dyspnea after the inhalation of nitric acid fumes at his workplace. He had conditions of tachypnea (respiratory rate 26 /min) and hypoxemia ($PaO_2$ 42.6 mmHg, $SaO_2$ 80.2% in room air) in our emergency department. The chest radiographs showed diffuse interstitial infiltrates and ground glass opacity in both lungs. The patient made improvements in clinical symptoms and chest radiography after being given a supply of oxygen, antibiotics, and bronchodilator therapy without systemic glucocorticoid therapy. On his follow up visit after 4 weeks, he showed no symptoms and sequelae, and the pulmonary function test showed a normal pulmonary function.

A Study on the Analysis and Methods to Improve the Management System for Building Energy Database (국가 건물에너지통합관리시스템의 데이터 품질 분석 및 개선방안 연구)

  • Kim, Sung-Min;Yoon, Jong-Don;Kwon, Oh-In;Shin, Sung-Eun
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.131-144
    • /
    • 2016
  • Damage occur frequently around the world on climate change and the main cause of greenhouse gas emissions regulation is growing. To this end, the government has built integrated management system for national building energy. The building energy information is total 6.8 million complex. Integrated management system for national building energy database are matched building registers information and energy information of the supply agencies. However, the matching process has its limitations so advanced work is in progress continuously. This study analyzed integrated management system for national building energy database quality and limitations and deduce improvement plan to increase system reliability and availability. The existing database matching average rate is 85.6%. 58.2% of the total non-matching data type has no building information. To ensure the ease of new database matching and the accuracy of the existing database matching, address standarization and building properties system are needed between building information and energy information. Also, The system construction is required to include information on other energy sources like petroleum energy which has high proportion of non-urban areas and small residential areas and renewable energy which has high potential in development and utilization.