• Title/Summary/Keyword: Supply of Medicine

Search Result 679, Processing Time 0.029 seconds

A Study on the Continuing Education of Dental Technicians (치과기공사의 보수교육에 관한 연구(I) -보수교육 실태와 인식을 중심으로 -)

  • Moon, Je-Hyuk
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.179-198
    • /
    • 2000
  • Since dental prosthesis is made possible only when dental technicians give themselves to the study of knowledge and the acquisition of updated skills, continuing education is of great importance in that it makes up for the efforts of dental technicians. Accordingly, continuing education relates to a system designed to contribute to the enhancement of the talents of dental technicians and the dental health of the nation. Specialized knowledge and information may work as the best weapon to preserve their jbs. This is true of this modern society where no one can expecth to survive without acquiring knowledge and information constantly for work is getting more classified and more divirsifide. This paper is dedicated to take a look at the current condition of the continuing education of dental technicians and to come up with measure to make general evaluation and to improve continuing education. This research resorts to 609 questionnaires among 6433 copies save unfaithfully responded 34 copos with 6.431 dental technicians as the subjects enrolled in the Dental technician Association. The collected questionnaires consist of 365 dental technicians living in Seoul and of 244 ones, Which account for 11.8 percent of dental technicians enrolled in the association. Because dental technicians live more in local areas than Seoul, the generalization of this survey leaves something to be desired. I have come up with the following findings. 1. 6,431 dental technicians, or 36.3 percent of an total of 14,956 licensed dental technicians, were admitted as numbers of the Dental Tachnician Association as of October 31, 1999. In the '98 continuing education. 4,141 dental technicians among 4,711 dental technicians got relevant training, and in the '99 continuing education, 4,075 technicians, or 75.9 percent of 5,365 technicians got relevant training while 1,290 technicians or 24.2 percent, fail to get relevant training. 2. The survey has it that 38.1 percent of dental technicians are ignorant of the laws on continuing education, and that technicians staying in local communities(146 persons, or 61.6%) take more part in education than those living in the capital of Korea(159 persons, or 146%), and that the older they are, the more money they earn, the more carrer they have, the higher position they hold, the more part they take in education 3. According to the survey, those who have the experience of getting training more than three times account for 52 persons(16.8%) in Seoul and 47 persons(22.4%) in local districts(p<0.01). In terms of sanctions in relation to continuing education, 26 dental technicians(4.6%) say that they have ever gotten sanctions, and 533 dental technicians(95.4%) say that they haven't. And those who were absent from continuing education(72 technicians : 13.51%) didn't get any sanction. 4. In terms of the degree of understanding continuing education, local technicians(46.8% : 110 persons) have a higher understanding of continuing education than their countparts staying in Seoul(36.0% : 130). Continuing education is not the ultimate goal itself. It should be changed to motivate those who get education to be willing to take part in contunuing education, and to help dental technicians in a practical and specific way. And the branch societies should be developde to engage in more specialized and classified expert fields. Of course, the curriculum should be so selected that the conceptions of dental technicians may be reflected to the maximum extent, and the ultimate effores should be made to effect diversity in the ways of educational methods and to perfect the preparation of continuing education on the part of instructors. Regulations should be established in relation to continuing education with a veiew to enhancing the participation of continuing education and its effectiveness. The supervision of the Ministry of Health and Welfare is of great importance in this context. The regulation of continuing education is not administrative regulation, but the expression of national will to guarantee the medical service of the nation at highest level. Therefore, it is necessary that the Ministry of Health and Welfare should change their understanding of the needs for the continuing education of dental experts, and that the expertise of government employees in charge of continuing education should be expanded. It goes without saying that the government should suppory continuing education in a financial way so as to supply the person in charge of public welfare and control the quality of national medicine.

  • PDF

암환자 인식에 관한 연구 - 간호사ㆍ의사를 중심으로

  • Jo, In-Hyang
    • Korean Journal of Hospice Care
    • /
    • v.2 no.1
    • /
    • pp.58-74
    • /
    • 2002
  • This paper constitutes a descriptive investigation and used a structured questionnaire to investigate nurses' and doctors' recognition of cancer patients. The subjects were extracted from the medical personnel working at the internal medicine, the surgery ward, the obstetrics and gynecology department, the pediatrics department, the cancer ward, and the emergency room of five general hospitals located in Seoul and Gyeonggi Province. The research lasted from August, 2001 to September 2001. Total 137 nurses and 65 doctors were included and made out the questionnaires directly distributed by the investigator. The study tool was also developed by the investigator and consisted of such items as the demographic and social characteristics, the medical personnel's recognition degree of cancer and cancer patients, their recognition of the management of cancer patients, and their participation in a hospice. The results were analyzed using the SPSS Window program in terms of technological statistics, ranks, t-test, and ANOVA. The reliability was represented in Cronbach' α=.75. The nurses' and doctors' recognition degree of cancer and cancer patients had an overall average of 3.86 at the 5 point-scale. The items that received an average of 4.0 or more included 'Medical personnel should explain about the cancer cure plans to the cancer patient and his or her family', 'A patient whose case has been diagnosed as a terminal cancer should be notified of it, 'If I were a cancer patient, I would want to get informed of it,' and 'Cancer shall be conquered whenever it is'. In the meantime, the items that received an average of 3.0 or less was 'My relationship with the cancer patient's family has gotten worse since I announced his or her impending death.' And according to the general characteristics and the difference test, the recognition degree of cancer and cancer patient was high among the subgroups of nurses, females, married persons, who were in their 30s, who had a family member that was a cancer patient, and who received a hospice education. The biggest number of the nurses and doctors saw 'a gradual approach over several days'(68.8%) as a method to tell a cancer patient about his or her cancer diagnosis or impending death. Those who usually tell tragic news were the physician in charge(62.8%), the family members or relatives(32.1%) and the clergymen(3.8%) in the order. The greatest number of them recommended a cancer patient's home as the place where he or she should face death because they thought 'it would stabilize his or her mentality'(91.9%) while a number of them recommended the hospital because they 'should give the psychological satisfaction to the patient'(40%) or 'should try their best until the last moment of the patient's death'(30%). A majority of the medical personnel regarded 'smoking or drinking' and 'diet' as the causes of cancer. The biggest symptom of a cancer patient was 'pain' and the pain management of a cancer patient was mostly impeded by the 'excessive fear of drug addiction, tolerance to drugs and side effects of drugs' by medical personnel, the patient, and his or her family. The most frequently adopted treatment plan of a terminal cancer patient was 'to do whatever the patient or his or her family wants' to resort to a hospice' and 'to continue active treatment efforts' in the order. The biggest reasons why a terminal cancer patient went to see a doctor were 'pain alleviation' 'control of symptoms other than pain(intravenous supply)' and 'incapability of the patient's family' in the order. Terminal cancer patients placed their major concern in 'spiritual(religious) matter' 'emotional matters' their family' 'existence' and 'physical matters' in the order. 113(58.5%) of the whole medical personnel answered they 'would recommend' an alternative treatment to a terminal cancer patient mostly because they assumed it would 'stabilize the patient's mentality.' Meanwhile, 80(41.5%) of them chose 'not to recommend it mostly due to the unverified effects and high cost of it(78.7%). A majority of them, I. e. 190(94.1%) subjects said they 'would recommend' a hospice to a terminal cancer patient mostly because they thought it would help the patient to 'mentally prepare'(66.6%) Only 17.3% of them, however, had received a hospice education, most of which was done through the hospital duty education(41.4%) and volunteer training(34.5%). The follows are results of this study: 1. The nurses and the doctors turned out to be still passive and experience confusion in dealing with a cancer patient despite their great sense of responsibility for him or her. 2.Nurses and Doctors realize the need of a hospice, but an extremely small number of them participate in a hospice education or performance. Thus, a whole recognition of a hospice should be changed, for which purpose a hospice education for nurses and doctors should be provided. 3.Terminal cancer patients preferred their home to a hospital as the place to face their impending death because they felt it would bring 'mental stability.' And most of nurses and doctors think it would be unnecessary for them to be hospitalized just for control of their symptoms. Accordingly a terminal cancer patient can be cared at home, and a home hospice care needs to be activated.

  • PDF

The Contents and Satisfation of Home Care Progral Delivered by Seoul Nurses Association (서울시 간호사회 가정간호시범사업 서비스 내용 및 만족도 분석)

  • Lim, Nan-Young;Kim, Keum-Soon;Kim, Young-lm;Kim, Kwuy-Bun;Kim, Si-Hyun;Park, Ho-Ran
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.59-76
    • /
    • 1997
  • The purposes of this study were to identify the contents and satisfaction level of the patients received home care service, and to compare the differences of the contents by the characteristics of the patients. Seventy eight patients received home care service from 1st Jan. to 30th Sept., 1996 were data-collected to analyze the contents and outcomes of home care service. Sixty-nine patients currently receiving home care service were participated to evaluate the satisfaction level of home care service. The data were analyzed using mean, standard deviation, $x^2$ test, and ANOVA by SPSS $PC^+$ program. The findings of this study were as follow : 1. The contents & outcomes of home care service 1) The mean age of the subjects was 64.4 years: 58% of them were female. Those who living in Seoul were 83% and the rest of the subjects was living in Kyung-Gi. 2) The subjects who had one diagnosis were 41%. Over 60% of them had the disease of neurologic & sensory system. 3) The mean number of visit was 6. Only one visit was 22%. The mean time of care was 79 minutes. Duration of visit from 31 minutes to 60 minutes were 47 %. The subjects who terminated the visit because of death were 67.3%. 62% of the persons who referred them to the home care service were nurses. 4) The pain after the service was more relieved than before. The amounts of intake, the degree of bed sore, edema & fracture after the service were more improved than before. Health status after the service was improved in general. 5) There were significant differences between initial and last conscious level in tracheostomy care & oxygen inhalation care. There was significant difference between initial and last degree of activity in blood sugar check. 6) There were significant differences on the number of visit in assessment of the status, evaluation & observation, vital sign check, skin care, injection, medication, bed sore care, colostomy care, relaxation therapy for pain relief, patient education, family care, exercise therapy, position change, supply of disinfected equipments and infection control. There were significant differences on visiting time in nasogastric tube care, drainage tube care and oxygen inhalation care. 2. The satisfaction level of home care service 1) 50% were male. Over 60 years of the subjects was 61 %. Those who living in Seoul were 82%. 2) The subjects who had one or two diagnosis were 32% respectively. 55% of the persons who referred them to the home care service were nurses. 3) Total level of satisfaction of home care service was very high. 4) The older the age, the higher the satisfaction level. The larger the number of visit, the higher the satisfaction level. 5) The subjects who were in cloudy state were higher level of satisfaction than in alert or coma state. The subjects whose activity were normal or who needed assistance were higher level of satisfaction than bedridden or immobilized subjects. These findings suggested that the patients had substantial need for posthospital care. They tended to be elderly and to have experienced the wide range of health problems associated with aging, chronicity, including limitations in activities, and other serious health problems. So, the nationwide home care systems beyond the limit of demonstration program by local association and the development of the effective financial system of home based health care are necessary for the clients who are in need of home care.

  • PDF

Observations of Oxygen Administration Effects on Visuospatial Cognitive Performance using Time Course Data Analysis of fMRI (뇌기능 자기공명영상의 시계열 신호 분석에 의한 공간인지과제 수행시 산소 공급의 효과 관찰)

  • Sohn Jin-Hun;You Ji-Hye;Eom Jin-Sup;Lee Soo-Yeol;Chung Soon-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.9-15
    • /
    • 2005
  • Purpose : This study attempted to investigate the effects of supply of highly concentrated $(30\%)$ oxygen on human ability of visuospatial cognition using time course data analysis of functional Magnetic Resonance Imaging (fMRI). Materials and Methods : To select an item set in the visuospatial performance test, two questionnaires with similar difficulty were developed through group testing. A group test was administered to 263 college students. Two types of questionnaire containing 20 questions were developed to measure the ability of visuospatial cognition. Eight college students (right-handed male, average age of 23.5 yrs) were examined for fMRI study. The experiment consisted of two runs of the visuospatial cognition testing, one with $21\%$ level of oxygen and the other with $30\%$ oxygen level. Each run consisted of 4 blocks, each containing control and visuospatial items. Functional brain images were taken from 37 MRI using the single-shot EPI method. Using the subtraction procedure, activated areas in the brain during visuospatial tasks were color-coded by t-score. To investigate the time course data in each activated area from brain images, 4 typical regions (cerebellum, occipital lobe, parietal lobe, and frontal lobe) were selected. Results : The average accuracy was $50.63{\pm}8.63$ and $62.50{\pm}9.64$ for $21\%\;and\;30\%$ oxygen respectively, and a statistically significant difference was found in the accuracy between the two types of oxygen (p<0.05). There were more activation areas observed at the cerebellum, occipital lobe, parietal lobe and frontal lobe with $30\%$ oxygen administration. The rate of increase in the cerebellum, occipital lobe and parietal lobe was $17\%$ and that of the frontal lobe, $50\%$. Especially, there were increase of intensity of BOLD signal at the parietal lobe with $30\%$ oxygen administration. The increase rate of the left parietal lobe was $1.4\%$ and that of the right parietal lobe, $1.7\%$. Conclusion : It is concluded that while performing visuospatial tasks, high concentrations of oxygen administration make oxygen administration sufficient, thus making neural network activate more, and the ability to perform visuospatial tasks increase.

  • PDF

A Study on the Establishment and Operation of a Regulatory Response Framework in connection with the Regulatory Strength of the Licensing Policy for New Medical Devices -Focusing on the Application of FMEA- (의료기기 신제품의 인허가정책 규제강도에 연계한 규제대응 프레임워크 수립 및 운영에 관한 연구 - FMEA 적용을 중심으로 -)

  • Kim, Gyosu;Ru, Gyuha;Kim, Yeonhee
    • Journal of Technology Innovation
    • /
    • v.28 no.4
    • /
    • pp.1-26
    • /
    • 2020
  • Due to the spread of Corona 19 around the world, Infectious Disease Medicine and New Medical Devices such as Diagnostic Agent are being rapidly developed and launched, and for the fast supply and demand of these, each country has eased import regulations or has implemented policies for fast approval(NIDS, 2020). On the other hand, New Developed Medical Devices that are not related to New Infectious Diseases, they are still entering the market through strict licensing and licensing regulations, such as delay and cancellation in the test inspection process, etc. Therefore, This Study specialized in the government-managed laws encountered when New Medical Devices enter the market, derive Factors influencing the Strength of Regulations, analyzes the Strength of Regulations, and proposes a Regulatory Response Framework. The Research Method was conducted by Literature Research, was applied by Failure Mode and Effects Analysis(FMEA) Method, Expert Interview(1st): Idea Collection, Expert Interview(2nd): Validation, and Priority through the Application Process of FMEA Method. A Method of Quantifying the Intensity of Regulation was proposed by multiplying the Impact of the Influencing Factors for each stage of regulation and the Burden Impact for each type of Regulatory Affairs to find the Importance of the Regulatory Factors and multiplying the Severity of the Regulatory Impact. The Implications are that major overseas countries and the Korean government are actively responding with Special Regulatory Policies and Mitigation Policies for fast licensing of New Developed Medical Devices in accordance with Corona 19. It is expected that the direction for improvement of regulations and measures to respond to regulations will be implemented so that a more proactive and preemptive response to the regulatory process of the licensing policy for New Devices can be achieved.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

The Present Status and a Proposal of the Prospective Measures for Parasitic Diseases Control in Korea (우리나라 기생충병관리의 현황(現況)과 효율적방안에 관(關)한 연구(硏究))

  • Loh, In-Kyu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.3 no.1
    • /
    • pp.1-16
    • /
    • 1970
  • The present status of control measures for public health important helminthic infections in Korea was surveyed in 1969 and the following results were obtained. The activities of parasitic examination and Ascaris treatment for the positives which were done during 1966 to 1969 were brought in poor result and could not decrease the infection rate. It is needed to improve or strengthen the activities. The mass treatment activities for paragonimiasis and clonorchiasis in the areas which were designated by the Ministry of Health were carried out during 1965 to 1968 with no good results in decrease of estimated number of the patients. There were too many pharmaceutical companies where many kinds of anthelmintics were produced. It may be better to reduce the number of anthelmintics produced and control the quality. The human feces, the most important source of helminthic infections, was generally not treated in sanitary ways because of the poor sewerage system and no sewage treatment plant in urban areas and insanitary latrines in rural areas. The field soils of 170 specimens were collected from 34 areas out of 55 urban and tourist areas where night soil has been prohibited by a regulation to be used as a fertilizer, and examined for parasites contamination with the result of Ascaris egg detection in 44%. Some kinds of vegetables of 64 specimens each from the supply agents of parasite free vegetables and general markets were collected and examined for parasites contamination with the results of Ascaris egg detection in 25% and 36% respectively. The parasite control activities and the ability of parasitological examination techniques in the health centers of the country were not satisfactory. The budget of the Ministry of Health for the parasite control was very poor. The actual expenditure needed for cellophane thick smear technique was 8 Won per a specimen. As a principle the control of helminthic infections might be led toward breaking the chain of events in the life cycle of the prasites and eliminating environmental and host factors concerned with the infections, and the following methods nay be pointed out. 1) Mass treatment might be done to eliminate human reservoirs of an infection. 2) Animal reservoirs which are related with human infections night be eliminated. 3) The excretes of reservoirs, particularly human feces, should be treated in sanitary ways by the means of sanitary sewerage system and sewage treatment plant in urban areas and sanitary latrines such as waterborne latrine, aqua privy and pit latrine in rural areas. The increase of national economical development and prohibition of the habit of using night soils as a fertilizer might be very important factors to achieve the purpose. 4) The control of vehicles and intermediate hosts might be done by the means of prohibition of soil contamination with parasites, food sanitation, insect control and snail control. 5) The improvement of insanitary attitudes and bad habits which are related with parasitic infections night be done by the means of prohibition of habit of using night soils as a fertilizer, and improving eating habits and personal hygiene. 6) Chemoprophylactic measure and vaccination may be effective to prevent the infections or the development of a parasite to adult in the bodies when the bodies were invaded by parasites. Further studies and development of this kind of measures are needed.

  • PDF

A Survey of Nutritional Status on Pre-School Children in Korea (학영기전아동(學齡期前兒童)의 영양실태조사(營養實態調査))

  • Ju, Jin-Soon;Oh, Seoung-Ho
    • Journal of Nutrition and Health
    • /
    • v.9 no.2
    • /
    • pp.68-86
    • /
    • 1976
  • The primary purpose of this study is to evaluate the correct nutritional status on pre-school children in Korea. Furthermore, it made an attempt to find and define nutrional problems, and assist in establishment on their nutritional improvement plan. For this, food intake and health condition (physical, clinical, biochemical and parasitological) survey on 109 Pre-school children in both sexes, randomly selected from Yang-Gu area in Gang-Won province and Rea-ju area in Kyong-gy Province, were conducted by means of three-day records, during the two periods of Spring and Fall season in 1975. The results obtained are summerized as follows: 1. The food intake; Average food intake of the subjects per day were $508{\sim}647g$ ($83{\sim}91%$ in vegetable foods and $5.5{\sim}11.7%$ in animal foods) in Yang-gu area, and $587{\sim}698g$ ($88{\sim}89%$ in vegetable foods and $6.3{\sim}7.6%$ in animal foods) in Rea-ju area. 2. The intake of energy and nutrients; a) Calory intake. Average energy intake of subjects per day in Yang-gu area$(1120{\sim}1415kcal)$ were all lower than the Korean Recommended Dietary Allowances (RDA) in either Spring and Fall survey, whereas the subjects in Rea-ju area were lower intake $(1213{\sim}1418kcal)$ than the RDA in the Spring but higher intake$(1516{\sim}1755kcal)$ than the RDA in the Fall, and the average intake were similar level with that of RDA. b) Protein intake. Average protein intake of the subjects per day in Yang-gu area $(33{\sim}43g)$ girl subjects in Rea-ju area $(35{\sim}39g)$ were lower than the RDA in either Spring and Fall survey, whereas the boy subjects in Rea-ju area$(36{\sim}38g)$ were lower in Spring and higher $(49{\sim}57g)$ in the Fall than that of the RDA, but the average $(43{\sim}47g)$ were similar level with the RDA. The protein intake from animal sources in all subjects were much lower $(5.5{\sim}11.7\;of\;total\;protein)$ than the RDA. c) Fat intake. Average fat intake were very lower in all subjects of both area $(14{\sim}24g\;in\;Yang-gu,\;10{\sim}12g\;in\;Rea-ju)$ than that of RDA which is recommended $12{\sim}14%$ of total energy to be supplied from fat. d) Calcium intake. Average calcium intake were very low in all subjects of both area $(264{\sim}355mg\;in\;Yang-gu\;and\;283{\sim}429mg\;in\;Rea-ju)$, especially, these in Spring were about a half level of the RDA, and it was much increased in the Fall due to increased intake of milk, but it was still not enough than the RDA. e) Vitamin A intake. Average intake of V.A ($703{\sim}1465\;IU$ in Ynag-gu and $750{\sim}1521\;IU$ in Rea-ju) were also lower than the RDA, moreover their V-A sources were mainly vegetable, so that the V-A supply might be critical one for the subjected. f) Riboflavin intake. Average riboflavin intake on all subjects in both area except boys in Rea-ju area in Fall, were very lower than the RDA. 3. The physical status; a) Average weight and height of boys aged 4 and 5 in Yang-gu area and girls of aged 5 in Rea-ju area were lower than those of Korean Standard of 1967 report, but those by age of girls in Yang-gu area and boys in Rea-ju area were a little heigher than the Korean Standard. It is, hower, present Korean standard of physical status might be somehow heigher than the 1967, since the socio-economical situation has been much improved during past a decade. So that, if one considered on this sense, the physical status of the subjects on this survey might be somehow lower than those of present Korean standard. b) Average upper arm circumference in both area were no difference each other, and their mean values of age 4, 5 and 6 in boy and girl were 15.6, 16.5, 16.4 and 15.5, 16.5, 16.4cm respectively. c) Average chest girth of boys were similar to those of Korean standard whereas the girls were smaller than the Korea standard. The average head circumference also showed similar tendency with the chest girth. 4. The clinical findings; The most popular clinical signs were angular stomatitis and dental caries, and boys had more heigher incidence then the girls. 5. The biochemical findings; a) Hemoglobin and anemia Average Hb value of boys and girls were 11.4 and 10.9g per 100 ml of blood respectively. The incidence of anemia (Hb value below 11 g/100 ml, by WHO) was increased by age, and girls had more heigher incidence than the boy (34% : 48%). The incidence of anemia in age of 4,5, and 6 in boys and girls were 28%, 41% 34%, and 33%, 50%, 49% respectively. The degree of the anemia was not severe, and the anemia of there subjects may be caused mainly low intake of better quality protein and low iron intake as well. b) Hematocrit. Average Ht value of whole subject were $39.9{\sim}41.6%$. c) Blood plasma protein. Average blood plasma protein contents of whole subjects were $6.6{\sim}7.4gm$ per 100 ml. The incidence of deficient range (<6.0g%, by ICNND) was only one girl of age 4 in yang Gu area. 6. Parasitological findgs; The most popular parasitism were asicris lumbicoides and trichocephalus trichiura, and about 2/3 of the whole subjects were suffering one or more of these parasitism.

  • PDF