• Title/Summary/Keyword: Supply apparatus

Search Result 125, Processing Time 0.024 seconds

Design of a LDC Recycling Load Tester for Hybrid and Electric Vehicles (하이브리드 및 전기 자동차용 LDC 재생형 부하 시험기 설계)

  • Lee, Choon-Il;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6258-6263
    • /
    • 2014
  • The LDC (Low Voltage DC-DC Converter) used for hybrid vehicles and electric vehicles was utilized to supply the electric apparatus load with a voltage and to charge the auxiliary batteries by receiving a high DC voltage from the high voltage battery. The LDC has a long-time load test during the manufacturing process. On the other hand, it has the disadvantage of considerable energy consumption because it has the structure to release the power as 100% heat during a load test. Therefore, in this paper, a recycling load test method was proposed and 75~90% energy saving was realized.

Experimental Study on Effects of PAG Oil for $CO_2$ Evaporation Heat Transfer (PAG 오일이 $CO_2$ 증발열전달에 미치는 영향에 관한 실험적 연구)

  • Lee, Sang-Jae;Kim, Dae-Hoon;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.357-363
    • /
    • 2008
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a horizontal micro-fin tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($400{\sim}1200\;kg/m^2s$), heat fluxes($10{\sim}30\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$), and PAG oil concentration($0{\sim}5\;wt%$). The variation of the heat transfer coefficient was different in accordance with the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

A Study on the Insulation Properties of Cryogen for the HTS SMES (고온 초전도 에너지 저장장치용 극저온 냉매의 절연 특성 연구)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Lee, Hai-Gun;Song, Jung-Bin;Kim, Hae-Jong;Seong, Ki-Chul;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.16-19
    • /
    • 2009
  • Recently, for improvement of the magnetic field of high temperature superconductor (HTS) apparatus, many studies investigating on operating in the range of $20{\sim}65K$ with liquid helium or the conducting method using cryocooler is actively reviewed. Also, the cooling method using solid nitrogen as cryogen is being suggested. Since the nitrogen has very large specific heat in solid state, it is expected that it can enable long time operation without a continuous supply of cooling energy. However, there is still insufficient data on the characteristics of solid nitrogen such as thermodynamic properties and liquid-solid phase change. Especially, there was almost no study done on the electrical insulation properties of solid nitrogen so far. In this study, solid nitrogen to find the electrical characteristics was made by using cryocooler and cryostat, and investigated the flashover discharge and breakdown. The results of this study will be useful as a basic data for electrical insulation design of the HTS system using solid nitrogen as cryogen.

A Study on Apparatus of Smart Wearable for Mine Detection (스마트 웨어러블 지뢰탐지 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.263-267
    • /
    • 2015
  • current mine detector can't division the section if it is conducted and it needs too much labor force and time. in addition to, if the user don't move the head of sensor in regular speed or move it too fast, it is hard to detect a mine exactly. according to this, to improve the problem using one direction ultrasonic wave sensing signal, that is made up of human body antenna part, main micro processor unit part, smart glasses part, body equipped LCD monitor part, wireless data transmit part, belt type power supply part, black box type camera, Security Communication headset. the user can equip this at head, body, arm, waist and leg in removable type. so it is able to detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal and it can express the 2D or 3D film about distance, form and material of the mine. so the battle combats can avoid the mine and move fast. also, through the portable battery and twin self power supply system of the power supply part, combat troops can fight without extra recharge and we can monitoring the battle situation of distant place at the command center server on real-time. and then, it makes able to sharing the information of battle among battle combats one on one. as a result, the purpose of this study is researching a smart wearable mine detector which can establish a smart battle system as if the commander is in the site of the battle.

The Effect of Jakamchotang(炙甘草湯) on Isolated rat herts under langendorff apparatus (자감초탕(炙甘草湯)이 재관류장치하에서 흰쥐의 적출심장(摘出心臟)에 미치는 영향(影響))

  • Moon, Hyung-Kun;Moon, Sang-Kwan;Ko, Chang-Nam;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.340-354
    • /
    • 1997
  • Background : The stenosis of the coronary artery results in a decrease in the myocardial oxygen supply, ischemia and infarction. Jakamchotang as a drug of liquid is generally regarded to have the effect of arrythmia, palpitation from Heart disease and promoting the flow of Ki and Blood. Methods : The purpose of this experimental study is to find whether Jakamchotang is effective or not in curing ischemia in isolated perfused rat hearts and to measure the degree of its curing effect. In this study, under the Langendorff apparatus, ischemia was induced in isolated Sprague-Dawley rat hearts by ceasing the perfusion for 20 minites. Subjects were divided into a normal saline orally administered group(control group), an Jakamchotang orally 100mg administered group (sample A), an Jakamchotang orally 300mg administered group (sample B), and an Jakamchotang injection perfused group(sample C). The heart rates, left ventricular pressure, myocardial dilatation/contraction, cardiac perfusion flow and cardiac ezyme(LDH, CPK) of the four group were measured and compared in order to assess the influence of Jakamchotang on isolated perfused rat hearts recovering abillity from ischemia and infarction. results : 1. Heart rates were increased significantly in Jakamchotang orally 100mg administered group, Jakamchotang orally 300mg administered group and Jakamchotang injection perfused group on perfusion and reperfusion(p<0.01). 2. Left ventricular pressure were increased significantly in Jakamchotang orally 100mg administered group and 300mg administered and Jakamchotang injection perfused group(p<0.01) in comparison with control group on perfusion, but every group did not significant on reperfusion. 3. While there were no differances in each group's abillities of myocardial dilatation, the ability of myocardial constriction of Jakamchotang 100mg administered group only on perfusion was significantly greater than that of control group(p<0.05). 4. CBF was no significant on perfusion and reperfusion in comparison with control group(N.S.) 5. LDH was not significantly decreased on perfusion, but significactly decreased in Jakamchotang orally 100mg administered group, Jakamchotang orally 300mg administered group on reperfusion. 6. CPK was significantly decreased in Jakamchotang orally 100mg administered group, 300mg administered and Jakamchotang injection perfused group on perfusion(p<0.01), but was not significantly in Jakamchotang 300mg administered group only on reperfusion(P<0.05) Conclusion : According to the result above, Jakamchotang have an effect to recover in the isolated perfused rat hearts. Especially, the effect of Jakamchotang in orally adminstered group is greater than that of Jakamchotang injection perfused group on preischemia. The followings are the two important results of this study: First, the effect of Jakamchotang used traditionally on heart disease was proved statistcally under the Langendorff apparatus. Second, on the basis of this study, the effect of other type medications on myocardial ischemia can be evaluted in further studies.

  • PDF

Remediation of Water Quality Using Up-Flow Circulation Apparatus(UFCA) in a Reservoir (용승순환장치를 이용한 호소의 수질개선에 관한 연구)

  • Kang, Chang-Min;Chung, Seon-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.255-260
    • /
    • 2008
  • This study was conducted to analyse the effects of the UFCA for treating polluted water in a reservoir. The UFCA mixes water by circulation of surface and bottom water layers. The circulation supplies oxygen to bottom of the reservoir, resulting in water quality improvement. With a UFCA in use, we surveyed the changes of temperature, pH, transparency, depth, conductivity, DO, COD, BOD, T-N, T-P and Chlorophyll-a for 7 months from Feb. to Aug. in 2004 in our experimental reservoir. There was little difference in the surface and bottom temperatures of the reservoir because of water mixing by the UFCA. However, pH was changed from 7 to 9. The transparency of water was about 80 cm through the all periods. Conductivity was $150\;{\mu}S/cm$ in early Feb., but increased to $270\;{\mu}S/cm$ in early March. Little change was seen in DO with depth, but it was maintained above 6 mg/l in June and July. BOD increased from 2.1 to 12.2 mg/l. The study reservoir did not undergo any eutrophication during the period of our experiment, but the comparison reservoir had an algae-bloom. The COD in the experimental reservoir increased from 5.4 to 14.5 mg/l. The COD concentration of the experimental reservoir was higher than comparison reservoir at the beginning of the study but in August this situation was reversed. SS concentration increased from 13.5 to 23.5 mg/l in Feb., but it fell from between 8.5 to 11.2 mg/l in July. T-N was increased from 1.3 to 4.9 mg/l. It increased up to 3 times in the rainy season as compared to other components. However the comparison reservoir increased up to 40 times higher than the experimental reservoir in the same period. T-P increased from 0.04 to 0.17 mg/l. The ratio of T-N to T-P increased from 20:1 to 40:1 which means that T-P was a growth limiting factor for algae and aquatic plants. Chlorophyll-a increased from 20 to 120 mg/l, and its concentration was correlated with T-P, such that Chlorophyl-a concentration increased with increased of T-P concentration. The concentrations of COD, T-N, T-P and other parameters were higher in the experimental reservoir than in the comparison reservoir but this situation was reversed in July, when the most severe eutophication occurred. The results show that overall the experimental reservoir was greatly remedied by UFCA. The UFCA accelerated the degradation of aquatic organic materials through effective supply of air with up-flow and circulation of water. We conclude that the UFCA can be very effective in aspect of the remediation of water quality incontaminated reservoirs and lakes.

Convenient and Economic Mechatronics Education Using Small Portable Electronic Devices (휴대용 소형 전자장비를 이용한 편리하고 경제적인 메카트로닉스 교육)

  • Kang, Chul-Goo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.63-71
    • /
    • 2016
  • Although mechatronics education in a mechanical engineering curriculum is recently recognized as important, its experimental education has been done generally in the laboratory equipped with all the apparatus and could not be done at home by students. This paper introduces experimental educations on mechatronics, e.g., digital logic circuits, 7-segment LED drive, square wave generation, microcontroller programming using assembly and C languages, timer interrupt, and step motor drive using a small 5 V power supply, a breadboard, various electronic and electric components, a microcontroller and its programmer, a step motor, and a student's PC. In the developed mechatronics course, experimental educations are scheduled in parallel with content's lectures together, and cheap and economic experimental environment is prepared for students in which students can easily practice experimental works in advance or later at home by themselves.

Implementation of The Fluid Circulation Blood Pressure Simulator (유체 순환 혈압 시뮬레이터의 구현)

  • Kim, C.H.;Lee, K.W.;Nam, K.G.;Jeon, G.R.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.768-776
    • /
    • 2007
  • A new type of the fluid circulation blood pressure simulator was proposed to enhance the blood pressure simulator used for the development and evaluation of automatic sphygmomanometers. Various pressure waveform of fluid flowing in the pipe was reproduced by operating the proportional control valve after applying a pressure on the fluid in pressurized oil tank. After that, appropriate fluid was supplied by operating the proportional control valve, which enabled to reproduce various pressure wave of the fluid flowing in the tube. To accomplish this work, the mathematical model was carefully reviewed in cooperating with the proposed simulator. After modeling the driving signal as input signal and the pressure in internal tube as output signal, the simulation on system parameters such as internal volume, cross-section of orifice and supply pressure, which are sensitive to dynamic characteristic of system, was accomplished. System parameters affecting the dynamic characteristic were analyzed in the frequency bandwidth and also reflected to the design of the plant. The performance evaluator of fluid dynamic characteristic using proportional control signal was fabricated on the basis of obtained simulation result. An experimental apparatus was set-up and measurements on the dynamic characteristic, nonlinearity, and rising and falling response was carried out to verify the characteristic of the fluid dynamic model. Controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. Hybrid controller combined with an proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid simulator indicated that even though the former showed good control performance.

A Study on the Improvement on the Target Structure in a Magnetron Sputtering Apparatus (마그네트론 스퍼터링 장치의 타겟구조 개선에 관한 연구)

  • Bae, Chang-Hwan;Lee, Ju-Hee;Han, Chang-Suk
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • The cylindrical magnetron sputtering has not been widely used, although this system is useful for only certain types of applications such as fiber coatings. This paper presents electrode configurations which improved the complicacy of the target assembly by using the positive voltage power supply. It is a modified type which has a target constructed with a large cylindrical part, a conical part and a small cylindrical part. When positive voltage was applied to an anode, a stable glow discharge was established and a high deposition rate was obtained. The substrate bias current was monitored to estimate the effect of ion bombardment. As a result, it was found that the substrate current was large. With cylindrical and conical cathode magnetron sputter deposition on the surface of the substrate to prevent re-sputtering, ion impact because it can increase the effectiveness with excellent ductility and adhesion of Ti film deposition can be obtained. We board at the front end of the ground resistance of $5\;k{\Omega}$ attached to the substrate potential can be controlled easily, and Ti film deposition with excellent adhesion can be obtained. Microstructure and morphology of Ti films deposited on pure Cu wires were investigated by scanning electron microscopy in relation to preparation conditions. High level ion bombardment was found to be effective in obtaining a good adhesion for Cu wire coatings.

DEVELOPMENT OF COMBIND WELDING WITH AN ELECTRIC ARC AND LOW POWER CO LASER

  • Lee, Se-Hwan;Massood A. Rahimi;Charles E. Albright;Walter R. Lempert
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.176-180
    • /
    • 2002
  • During the last two decades the laser beam has progressed from a sophisticated laboratory apparatus to an adaptable and viable industrial tool. Especially, in its welding mode, the laser offers high travel speed, low distortion, and narrow fusion and heat-affected zones (HAZ). The principal obstacle to selection of a laser processing method in production is its relatively high equipment cost and the natural unwillingness of production supervision to try something new until it is thoroughly proven. The major objective of this work is focused on the combined features of gas tungsten arc and a low-power cold laser beam. Although high-power laser beams have been combined with the plasma from a gas tungsten arc (GTA) torch for use in welding as early as 1980, recent work at the Ohio State University has employed a low power laser beam to initiate, direct, and concentrate a gas tungsten arcs. In this work, the laser beam from a 7 watts carbon monoxide laser was combined with electrical discharges from a short-pulsed capacitive discharge GTA welding power supply. When the low power CO laser beam passes through a special composition shielding gas, the CO molecules in the gas absorbs the radiation, and ionizes through a process known as non-equilibrium, vibration-vibration pumping. The resulting laser-induced plasma (LIP) was positioned between various configurations of electrodes. The high-voltage impulse applied to the electrodes forced rapid electrical breakdown between the electrodes. Electrical discharges between tungsten electrodes and aluminum sheet specimens followed the ionized path provided by LIP. The result was well focused melted spots.

  • PDF