• 제목/요약/키워드: Supply and Exhaust

검색결과 257건 처리시간 0.026초

밸브 타이밍 변화가 3기통 LPG 엔진의 성능과 Idle 특성에 미치는 영향에 관한 연구 (A Study on the Effect of Valve Timing on the Performance and Idle characteristics of 3-Cylinder LPG Engine)

  • 이지근;이한풍;노병준
    • 한국자동차공학회논문집
    • /
    • 제5권3호
    • /
    • pp.27-34
    • /
    • 1997
  • The effects of the intake and exhaust valve timing to improve the engine performance in a spark ignition 3-cylinder LPG engine with a closed loop fuel supply system were studied. The engine torque and power have been measured using the 75kW EC-dynamometer while adjusting the optimal fuel consumption ratio with a solen- oid driver. As the results from this experiment, when intake valve opening is $12^{\circ}$ BTDC, intake valve closing is $36^{\circ}$ ABDC, exhaust valve opening is $12^{\circ}$ ATDC, and exhaust valve closing is $36^{\circ}$ BBDC respectively, the best torque characteristics in low and high speeds for a gives engine were obtained. And also we could find that the torque characteristics in low speeds were affected by the timing of exhaust valve open. An increased valve overlap by the EVC delay was ineffectual to the torque characte- ristics improvement in high speeds.

  • PDF

열회수장치에 의한 열교환 성능 분석(농업시설) (Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct)

  • 서원명;강종국;윤용철;김정섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF

흡.배기 밸브의 밀착이상이 엔진연소특성에 미치는 영향 (The Effects of an Abnormal Adjusting Intake and Exhaust Valves on the Combustion Characteristics of SI Engine)

  • 박경석;손성만
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.123-129
    • /
    • 2005
  • The unbalance of the power output, noise, and vibration is happened by the disproportionate pressure variation in the cylinder. For this reason, decrease of the pressure in the cylinder and increase of the residual gas effect on the engine performance. If the abnormal combustion is continued, the crack would be occurred in the engine block. And it could be broken down. For the normal combustion of the SI engine, it is important to supply the balanced mixture by each operating condition. In this study, it was tested the combustion characteristics in the cylinder according to the abnormal adjusting of intake & exhaust valve. This test is willing to set a basic data's analysis fur developing an automotive diagnosis system by analyzing the pressure in the cylinder, the output signal of MAP sensor, the exhaust gas, etc.

선로부 TES를 갖는 지하철 역사내 화재의 수치 해석 (A NUMERICAL STUDY ON THE FIRE EMERGENCY IN THE UNDERGROUND STATION WITH TRACKWAY EXHAUST SYSTEM (TES))

  • 박종택;원찬식;허남건
    • 한국전산유체공학회지
    • /
    • 제11권4호
    • /
    • pp.26-31
    • /
    • 2006
  • In the present study, a numerical simulation of the subway carriage fire is performed to determine the more effective operation of Trackway Exhaust System(TES) in underground stations. The four types of possible TES operation (OSUS, OSUE, OEUS and OEUE) is simulated and compared their removal capability of smoke and hot temperature for the carriage fire of 2MW. From the results, the distribution of temperature and smoke concentration is more dependent on the operation of fans located at upper side of the platform than those at lower side. It is also found from the results that for more efficient smoke control, the fans at upper side of the platform should be operated as an exhaust system. Whereas the fans at lower side can be operated as a supply system to aid upper exhaust fans.

VR 영상관에서의 급기 및 배기 방식에 따른 향 농도 분포 수치해석 (Numerical Simulation of Aroma Concentration Distribution in a VR Theater for different Supply and Exhaust Conditions)

  • 김영일;김기정;허남건
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 추계학술대회 논문집
    • /
    • pp.212-216
    • /
    • 2000
  • 어떤 특정한 환경과 상황을 가상적으로 모의함으로써 그 환경에 있는 사람이 마치 실제적인 환경 또는 상황과 상호 작용을 하고 있는 것처럼 만들어 주는 진보된 기술을 가상현실(virtual reality) 이라고 한다. 가상현실을 실현하기 위해서는 주변의 영상, 음향, 운동감, 열환경, 후각환경 등이 실제처럼 제시되어야 한다. 본 연구에서는 이중 후각환경의 제시를 위하여 급기 및 배기 위치에 따른 향 농도의 분포를 수치해석적으로 예측한다. 수치해석 결과는 VR 영상관의 향 배기 시스템의 설계 자료로 활용된다.

  • PDF

초고층 공동주택 국소배기용 입상덕트의 배기성능평가 (The Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;김웅용;신현곤
    • 유기물자원화
    • /
    • 제22권3호
    • /
    • pp.60-67
    • /
    • 2014
  • 고층 공공주택의 화장실과 주방에 적용되는 배기 시스템은 기본적으로 두 종류의 환기팬이 적용된다. 가지 기본 유형의 지붕 팬이다. 그 하나가 자연 통풍력을 활용하는 무동력 팬이고 다른 하나는 자연 통풍력이 없을 때, 모터를 활용하여 강제로 구동하는 팬을 적용하는 방식이다. 자연/강제 겸용으로 지붕에 적용되는 환기팬은 회전축에 모터가 있습니다. 대한민국에는 많은 고층건물이 있다. 그러나 고층건물의 환기가 굴뚝효과에 의존된다고 판단하였기 때문에 이러한 건물의 실내에서 발생하는 오염물질의 제거에 대한 관심을 크게 갖지 않고 있다. 본 연구는 외기압력과 초고층아파트에 사용되는 배기연돌에 적용되는 차압에 의해 결정되는 연돌압력을 조사하기 위함이다. 본 논문은 화장실 배기풍량과 대기의 자연풍속을 변수로 하여 루프팬에 설치된 모타의 전력공급시간을 판단함으로써 기존 배기팬보다 향상된 배기효율을 예측하기 위해, 수행되었다.

DI 디젤기관에서 함산소연료(EGBE)와 EGR의 유용성에 관한 실험적 연구 (An Experimental Study on Usability of Oxygenated Fuel(EGBE) and EGR in a DI Diesel Engine)

  • 최승훈;황윤택;김우상;오영택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1697-1702
    • /
    • 2003
  • In this paper, the effect of oxygen component in fuel on the exhaust emissions has been investigated for a direct injection diesel engine. It was tested to estimate change of engine performance and exhaust emission characteristics for the commercial diesel fuel and oxygenated blended fuel which has seven kinds of mixed ratio. And, the effects of exhaust gas recirculation(EGR) on the characteristics of NOx emission have been investigated. Ethylene glycol mono-n-butyl ether(EGBE) contains oxygen component 27% in itself, and it is a kind of effective oxygenated fuel of mono-ether group that the smoke emission of EGBE blended fuel is reduced remarkably compared with commercial diesel fuel, that is, it can supply oxygen component sufficiently at higher loads and speeds in a diesel engine. It was found that simultaneous reduction of smoke and NOx was achieved with oxygenated fuel and cooled EGR method.

  • PDF

백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구 (Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction)

  • 왕쩐후안;전종균;권영철
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

CFD를 이용한 기상청 지중온도의 피트부분 지중열원 유용성 평가에 관한 연구 (Effectiveness Assessment on the Soil Temperature of KMA as Ground Heat Source Using CFD in Pit Area)

  • 민준기;김정태
    • KIEAE Journal
    • /
    • 제8권5호
    • /
    • pp.49-54
    • /
    • 2008
  • The experimental of temperature, humidity and velocity was taken from the underground pit which utilized the system of ground heat source quite similar to the cool-pit system. Also, through CFD analysis, one could review the effectiveness of analysis of future alternatives. Furthermore, the temperature range of mock up cool-pit system was analyzed by inputting the weather data of annual average soil temperature provided by KMA(Korea Meteorological Administration) into the fluid simulation of anticipated heat distribution. Firstly, the difference between the temperature of air exhaust of the pit or the temperature of air supply of the compressor room and the experimental data for the month of May from the CFD analysis came out to be $0.6^{\circ}C$ and $0.9^{\circ}C$ respectively with tolerance of 3.1% and 4.7%. Secondly, the difference between the temperature of air exhaust of the Pit or the temperature of air supply of the compressor room and the experimental data for the month of July from the CFD analysis came out to be $0.8^{\circ}C$ and $1.1^{\circ}C$ respectively with tolerance of 3.3% and 4.5%. Thirdly, for the month of May, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.9^{\circ}C$ and $1.8^{\circ}C$ respectively with tolerance of 10.7% and 9.8%. Fourthly, for the month of July, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.1^{\circ}C$ and $1.4^{\circ}C$ respectively with tolerance of 4.5% and 5.8%. The result of above experiments allowed us to establish CFD model set up as a verification tool that is based on experimental data collected within the Pit area. Also, one could confirm the possibility to apply weather data of soil temperature provided by KMA in order to anticipate proper value for CFD analysis.

직분식 디젤기관의 메탄올 흡기분사에 의한 기관성능과 배기배출물에 관한 연구 (A Study on the Engine Performance and Exhaust Emission with Intake Port Methanol Injection in a DI Diesel Engine)

  • 김명수;라진홍;안수길
    • 수산해양기술연구
    • /
    • 제36권3호
    • /
    • pp.249-256
    • /
    • 2000
  • In order to investigate the effectiveness of methanol, which has high latent heat of evaporation and oxygen contents, for DI diesel engine performance and exhaust emission, the methanol was injected at the suction port of DI diesel engine. The injector used for test was conventional gasoline engine injector and controlled the quantity of methanol per cycle by the power supply controller which designed specially for injector. The results shown that the maximum pressure point was delayed, the value of maximum pressure was decreased, and the concentrations of both NOx and Soot were decreased, as the methanol injection quantity increased, and also the thermal efficiency of engine injected methanol under the high load condition was similar to no methanol injection but under the medium load condition was decreased within the experimental conditions.

  • PDF