Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System (복합 열원 공조시스템의 최적 제어 알고리즘)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.

An Experimental Study on the Cooling Operation Characteristics for Different Entering Water Temperatures In Geothermal Heat Pump System (지열히트펌프 시스템의 EWT의 변화에 따른 냉방운전 특성에 관한 실험적 연구)

  • Ahn, Byung-Chun;Kim, Jae-Wan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, an experimental study on the cooling operation characteristics for different entering water temperatures in geothermal heat pump system are carried out by using Lab VIEW system program Set-point temperature controls for cooling water and supply air temperatures is applied to analyze the energy consumption and control performances. As a result, the system responses show that different entering water temperatures(EWT) effect greatly on the energy consumption and system COP.

Effect of Distilled Water Supply Method on Performance of PEMWE Typed Hydrogen Generators for Inhalation (흡입용 PEMWE형 수소 발생기에서 증류수 공급 방법이 성능에 미치는 영향)

  • In-Soo, You;Hyunwoo, Bae;Joon Hyun, Kim;Jaeyong, Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.117-127
    • /
    • 2022
  • The present study has investigated the performance of hydrogen gas generators for inhalation purposes based on polyelectrolyte membrane water electrolysis (PEMWE). The system applied two watering methods. One is pumped water (pumping system) and the other is gravity-fed water without a pump (non-pumping system). The cell efficiencies were compared by measuring the cell voltage and temperature in the hydrogen gas generator, respectively. The results show that the cell voltage and temperature increase with the cell current. The cell temperature is lower in the pumping system than that in the non-pumping system at a given cell current. Even though the amount of hydrogen production is the same regardless of the pumping system, the cell efficiency of the hydrogen gas generator in the non-pumping system is better than that in the pumping system.

A Study on the Performance of Ondol with a Ventilation System (환기시스템을 갖춘 온돌 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4047-4051
    • /
    • 2014
  • Modern apartment houses are constructed to be relatively airtight with a high heat insulation system to increase the energy efficiency. Such a system has a range of deleterious effects due to the insufficient ventilation. In this study, the ondol system, which is used as a heat source typical of winter in Korea, was set as the default system to evaluate the indoor heat environment according to the ventilation method, the factors of energy reduction by the ventilation system was analyzed. The experimental apparatus was used to simulate the ambient conditions for a certain constant temperature and humidity chamber. The experimental results showed that the supply water temperature higher air volume decreases with increasing supply air temperature in the following order: floor supply/exhaust > total heat exchange supply/exhaust > forced supply/exhaust. Through this study, the applicability of various ventilations could be examined.

Control and Design of a Arc Power Supply for KSTAR's the Neutral Beam Injection

  • Ryu, Dong-Kyun;Lee, Hee-Jun;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.216-226
    • /
    • 2015
  • The neutral beam injection generate ultra-high temperature energy in the tokamak of nuclear fusion. The neutral beam injection make up arc power supply, filament power supply and acceleration & deceleration power supply. The arc power supply has characteristics of low voltage and high current. Arc power supply generate arc through constant output of voltage and current. So this paper proposed suitable buck converter for low voltage and high current. The proposed buck converter used parallel switch because it can be increased capacity and decrease conduction loss. When an arc generated, the neutral beam injection chamber occur high voltage. And it will break output capacitor of buck converter. Therefore the output capacitor was removed in the proposed converter. Thus the proposed converter should be designed for the characteristics of low voltage and high current. Also, the arc power supply should be guaranteed for system stability. The proposed parallel buck converter enables the system stability of the divided low output voltage and high current. The proposed converter with constant output be the most important design of the output inductor. In this paper, designed arc power supply verified operation of system and stability through simulation and prototype. After it is applied to the 288[kW] arc power supply for neutral beam injection.

A Study on the Development of a Multi-Heat Supply Control Algorithm in a District Heating Apartment Building in Accordance with the Variation of Outdoor Air Temperature (외기온도 변화에 따른 지역난방 공동주택 다중 열공급제어 알고리즘 개발에 관한 해석적 연구)

  • Byun, Jae-Ki;Yun, Sung-Ho;Nam, Ki-Hoon;Choi, Young-Don;Sin, Jong-Geun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.585-594
    • /
    • 2013
  • In this study, we developed a heat supply control algorithm that minimizes the heat loss in the heat distribution pipelines used for supplying heat energy to shared group housing. Controlling the temperature and flow rate of the hot water supplied to the heat exchanger for shared group housing enables us to develop a heat supply control technique that meets the heating load required by each household in a shared apartment building in accordance with changes in the outdoor air temperature, and that minimizes the heat loss occurring in the heat distribution pipeline. A one-year study in 2008 on a 1,473-household D-apartment building in Hwaseong, Gyeonggi-do, South Korea, compared the heat capacity used by each household, as well as the heat capacity supplied to the heat exchanger room of the apartment housing building, to calculate the amount of heat loss in the heat distribution pipeline. The results confirmed that 24.1% of the heat supplied was lost in the piping.

Optimization of Air Supply for Increased Polymer Electrolyte Fuel Cell System Efficiency (고분자 전해질 연료전지 시스템의 효율향상을 위한 공기공급 최적화)

  • Chu, Keon-Yup;Jo, Ki-Chun;SunWoo, Myoung-Ho;Choi, Seo-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.44-51
    • /
    • 2011
  • Polymer Electrolyte Fuel Cells (PEFCs) operate in wide-range changes in temperature, humidity, and electric current for automotive applications. In order to operate automotive PEFC efficiently, optimal air supply is required to adjust to these changes. This paper presents an air-supply optimization process that consists of experiments, modeling of the PEFC system, and optimization. The objective is to establish an air supply suitable for the required power for PEFC system and optimized with a Lagrange multiplier. Our simplified PEFC system model is used as a constraint for optimization problem. The result of this paper presents that efficient operation of PEFC system can be achieved by air-supply optimization.

Diagnosis of power supply by analysis of chaotic nonlinear dynamics (카오스 비선형 동력학 해석에 의한 수·변전설비의 진단)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.1
    • /
    • pp.113-119
    • /
    • 2013
  • In this paper, n order to degrade of diagnosis of power supply by using Poincare map and fractal dimension with temperature measured by infrared camera. we review the characteristic of temperature variation according to pattern variation of power supply in chemical industry complex. As a simulation results we can be realized the characteristic behaviors of nonlinear dynamics in the poincare mal and fractal dimension. In the future verification method requires through additional research.

The Effect of Oil-Starvation on the Lubrication Characteristics of High-Speed Bearing: Part I-Ball Bearing (가스터어빈용 고속 베어링의 Oil-Starvation 윤활특성: Part I-Ball Bearing)

  • Kim, Ki-Tae
    • Tribology and Lubricants
    • /
    • v.13 no.1
    • /
    • pp.70-75
    • /
    • 1997
  • The lubrication characteristics of high-speed ball bearings at oil-starvation have been investigated empirically using the bearings employed in small industrial gas turbine engines. For the close structural simulation, experiments carried our with bearing mounting supports of real engines, such as bearing housings and oil nozzle assemblies with squeeze film dampers. Thus the results of tests can be applied to the design and the development of gas turbine engines. Testing was done by simulating the oil-starvation conditions in engines, such as stopping the oil-supply to the bearing during normal operating, starting without oil-supply at atmospheric temperature, and accelerating with oil-supply at atmospheric temperature. From this study, the relative comparison of the frictional resistance and the resistance due to the bearing cavity oil was demonstrated visually, and the resistance due to the bearing cavity oil was dominant in the resistance of bearing at high speed.

A Study on the Fluid Network Analysis for the LPG Supply System of the Gaseous Fuel Injection Type (LPG 가스분사 방식 연료공급시스템의 관로 유동해석에 관한 연구)

  • Yun, Jeong-Eui;Kim, Myung-Hwan;Nam, Hyeon-Sik;Jeong, Tae-Hyuung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.35-40
    • /
    • 2007
  • The gaseous fuel injection (GFI) type in LPG fuel supply system has more advantage than the liquified fuel injection type from the viewpoint of durability and cost reduction. But in GFI system, to control pressure and temperature of gaseous fuel is needed to get precision fuel metering for the compressible characteristic of gaseous fuel. In this study, the effects of pressure and temperature on the fuel metering was simulated by commercial flow network analysis package, Flowmaster. And the fuel composition effects on the fuel metering were also studied to figure out the fuel metering characteristics.