Development of a GIS-Based Basin Water Balance Analysis Model (GIS 기반의 유역물수지 분석모형 개발)

  • Hwang, Eui-Ho;Kim, Kye-Hyun;Park, Jin-Hyeog;Lee, Geun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.4
    • /
    • pp.34-45
    • /
    • 2004
  • Existing Semangeum's water balance analysis simplifies whole basin to single basin and achieved volume of effluence that produce by Kajiyama way to foundation. But Semangeum is complicated and various rice-wine strainer supply system. And there is difficulty to apply as elastic when water balance element is changed at free point. Divided to unit possession station for suitable water balance analysis model application to Semangeum in this study. And developed basin water balance model of GIS base that can do details analysis is bite about development and transfer of an appropriation in the budget of basin water resources. Achieved study including abstraction and concept design that use UML (unified modeling language) diagram for details analysis, stream network composition for rice-wine strainer supply system application, preprocessing of GIS base and postprocessing module development, model revision and verification etc. Support of this water balance analysis model is available to establish efficient water resources administration plan through outward flow process analysis of water resources. And support is considered to be possible in more convenient and, reasonable water resources administration way establishment by minimizing manual processing in systematic water resources government official to user and support diversified analysis system.

  • PDF

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

A Research on the Implementation and Estimation of an Integrated System for Information Management in the Field of Nuclear Science and Engineering (원자력분야 학술정보 통합정보관리시스템 구현에 관한 연구)

  • Chun, Young-Choon
    • Journal of Information Management
    • /
    • v.34 no.4
    • /
    • pp.63-84
    • /
    • 2003
  • This research is a case study that describes the NUCLIS21(Nuclear Information System 21), an integrated web-based information management system of KAERI(Korea Atomic Energy Research Institute), implemented to carry out the role of a national nuclear information center with government support as an information infra implementation programme. Through its user-centered single interface, the system aims at building an infrastructure for the national nuclear information center, as well as improving the information management system of the TID(Technical Information Department) within the institute. The system consists of two major parts which are an integrated module of the MIS and six different kinds of system. These include the Integral search system with OPAC, My Library, the Acquisition system, the Catalogue system, the Information Supply system, and the Serial Publication system. The DB is composed of Bibliographical DB, Original text DB and Abstract DB. A special feature of this system was designed as a unified network system through connection to MIS(Management Integration System) of the institute, so users can get research information for projects. Therefore, they have access to available information easily and access to the ongoing service of this system. Furthermore, users can share information by using our system. The survey has it that 75.7%(200 persons), 62.1%(164 persons) and 78.4%(207 persons) of the respondents are satisfied with the fidelity, speediness, and convenience of the system respectively, and the overall satisfaction of the respondents is comparably high.

Development of Power Supplies for Radiation Monitoring System and Process Control System of Korean-type Standard Nuclear Pourer Plants (한국형 표준원전의 방사선감시계통 및 공정제어계통 전원공급기 국산화 개발)

  • Roh, J.H.;Kwon, Y.G.;Jang, D.S.;Oh, C.Y.;Lee, C.H.;Kim, Y.K.;Ju, D.S.;Cho, H.M.;Park, W.G.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.515-517
    • /
    • 2008
  • 현재 가동 중인 원자적발전소 계측제어설비의 전원공급기를 살펴보면 인버터 또는 별도의 교류를 입력전원으로 사용한다. 직류 전원공급기들은 설비의 중요도예 따라 이중화로 구성된 설비도 있고 그렇지 않은 기기나 설비도 있다. 이중화로 구성된 전원공급기라 해도 교류 입력전원이 동일하다면 교류 입력이 상실될 때 이중화로 구성된 직류전원도 상실되어 관련계통의 가동이 정지된다. 이러한 문제점을 해결하기 위해서는 각기 다른 교류입력전원으로 동작되는 이중화전원공급기로 구성되는 것이 가장 바람직하다. 본 연구개발의 목적은 두 종의 설비에 소요되는 3종의 직류전원 공급기를 원자력 안정성등급으로 국산화하는 연구이다. 기존 제품들은 3종 모두 리니어 방식의 제품이지만, 방사선감시 계통 현장제어기의 5V로직 전원공급기와 공정제어계통 전원공급자는 전력변환효율이 높고 소형, 정량화가 가능한 SMPS(Switched Mode Power Supply) 방식으로 개발하였다. 방사선감시계통 현장제어기의 PCA(Printed Circuit Assembly) 저전압공급기는 다양한 종류의 출력전압과 저 전류형이므로 안정성 면에서 동일한 형식의 리니어 방식으로 개발하였으며 3종류 모두 출력용량을 20% 이상 향상시켰다. 또한, 논문을 통해 SMPS 방식의 전원공급기의 핵심 부품인 Control Module을 Hybrid IC형으로 자체 설계하여 성능이 우수한 제품을 지속적으로 생산할 수 있는 기틀을 마련하고자 한다.

  • PDF

Development of the Passive Outside Insulation Composite Panel for Energy Self-Sufficiency of Building in the Region (지역 건축물의 에너지 자립을 위한 패시브 외단열 복합패널 개발 연구)

  • Moon, Sun-Wook
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2018
  • The study aims to address the energy crisis and realize self-sufficiency of building as part of local energy independence, breaking away from a single concentrated energy supply system. It is intended to develop modules of the outside insulation composite panels that conform to passive certification criteria and for site-assembly systematization. The method of study first identifies trends and passive house in literature and advanced research. Second, the target performance for development is set, and the structural material is selected and designed to simulate performance. Third, a test specimen of the passive outside insulation curtain wall module designed is manufactured and constructed to test its heat transmission coefficient, condensation performance and airtightness. Finally, analyze performance test results, and explore and propose ways to improve the estimation and improvement of incomplete causes to achieve the goal. The final test results achieved the target performance of condensation and airtightness, and the heat transmission coefficient was $0.16W/(m^2{\cdot}K)$, which is $0.01W/(m^2{\cdot})K$ below the performance target. As for the lack of performance, we saw a need for a complementary design to account for simulation errors. It also provided an opportunity to recognize that insulated walls with performance can impact performance at small break. Thus, to be commercialized into a product with the need for improvement in the design of the joint parts, a management system is needed to increase the precision in the fabrication process.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

ITER HCCR TBM 헬륨냉각계통 개발을 위한 헬륨공급장치 구축 및 실험계획

  • Lee, Eo-Hwak;Kim, Seok-Gwon;Jin, Hyeong-Gon;Yun, Jae-Seong;Jo, Seung-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.465-465
    • /
    • 2014
  • 증식블랑켓모듈(TBM, Test Blanket Module)을 개발하여 왔다. 이 두 증식블랑켓모듈은 모두 헬륨냉각을 기반으로 개발 되어왔으며 이에 따라, 헬륨순환기, 헬륨히터 및 헬륨열교환기 등에 대한 기본적인 연구가 수행되었다. 이후 2012년 고체형 증식블랑켓모듈을 ITER TBM 개념으로 주도하기로 결정함에 따라, HCCR (Helium Cooled Ceramic Reflector) TBM의 보조계통인 하나인 헬륨냉각계통(HCS, Helium Cooling System)에 대한 개발이 본격적으로 이루어졌다. 한국원자력연구원에서는 HCCR TBM의 냉각성능을 만족하기 위하여 8 MPa, 1.5 kg/s 및 $300/500^{\circ}C$ (입구/출구 온도)의 운전조건을 갖는 헬륨냉각계통의 설계를 완료하였다. 설계된 헬륨냉각계통은 HCCR TBM에서 회수된 약 $450^{\circ}C$의 헬륨을 열회수기(recuperator)기와 냉각기를 통해 상온으로 냉각시킨 후, 필터를 통해 헬륨을 여과시킨다. 여과된 헬륨은 헬륨순환기에 의해 가압되어 열회수기를 다시 지나 $300^{\circ}C$ 이상으로 가열된다. 가열된 헬륨은 열회수기를 지나지 않는 상온의 헬륨과 혼합되어 최종적으로 HCCR TBM의 입구온도 조건인 $300^{\circ}C$로 맞추어 HCCR TBM에 공급된다. 이러한 열회수기 중심으로 '${\infty}$' 모양의 자가 교차로 설계된 헬륨냉각계통은 고온영역과 저온영역으로 냉각회로를 구분하여 순환기, 필터 및 각종 계측기의 운전온도 환경을 상온으로 유지시킬 수 있어 운전 및 유지보수 관점에서 이점이 있다. HCCR TBM의 헬륨냉각계통 설계 및 핵심 기기를 실증하고, 운전 경험을 쌓기 위하여 헬륨공급장치(HeSS, Helium Supply System)를 헬륨유량기준 1/3 규모(0.5 kg/s)로 구축하였으며, '14년까지 HeSS를 실증규모로 업그레이드 하기 위하여 80기압 환경에서 압축비 1.1, 유량 1.5 kg/s의 성능을 내는 헬륨순환기를 설치할 예정이다. 현재 구축된 1/3 규모 HeSS는 국내 구축된 전자빔 고열부하 시험 장비인 KoHLT-EB (Electron Beam)와 연계되어 HCCR TBM의 일차벽(플라즈마 대향부품)을 검증할 예정이며, 이를 통해 얻어진 열수력 DB는 현재 개발중인 핵융합로 안전해석코드인 GAMMA-FR 검증에 활용될 계획이다.

  • PDF

Implementation of Active RFID System Using Prediction Packet Algorithm for Ultra Low Power Wireless Communication (초저전력 무선통신을 위한 패킷 예측 알고리즘을 이용한 능동형 RFID 시스템 구현)

  • Lee, Kyung-Hoon;Lee, Bae-Ho;Kim, Young-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8A
    • /
    • pp.661-668
    • /
    • 2012
  • In this paper, we introduce the low power wireless communication method and propose new protocol and algorithm for wireless communication which can be applied Active RFID system. Transceiver module is composed of MCU, RF transceiver and chip antenna. and it used the lithium coin battery for power supply. The experimental result is confirmed minimum power consumption which show average $10{\mu}A$(packet transmit) and $30{\mu}A$(packet receive) per second. It can be used ultra low power wireless communication. this result is possible for using the algorithm which predict the arrival time of packet. and it indicates that are possible to prevent malfunction and enhance responsiveness.

Reuse of Petroleum Refinery Wastewater Using Reverse Osmosis Membrane (역삼투막을 이용한 정유산업 폐수 재활용 연구)

  • Hwang, Jong-Sic;Sang, Byoung-In;Yoo, Je-Kang;Lee, Kyu-Hyun;Min, Byoung-Ryul;Kim, Byoung-Sik
    • Membrane Journal
    • /
    • v.4 no.4
    • /
    • pp.213-220
    • /
    • 1994
  • Reverse osmosis(R/O) pilot system, which consists of pretreatments and R/O membranes, was demonstrated to regenerate the petroleum refinery wastewater for the process feedwater supply. Despite of the unsteady quality of the wastewater effluent from the process facilities, relatively high salt rejection of 96~99% was obtained and the product water showed a feasible quality for the use of cooling tower feed water. The results of R/O membrane module cleaning with NaOH solution represented that there was some fouling effects on the membrane performance during the period of test due to the ineffective treatment processes proposed and used in this study.

  • PDF

Design and Implementation of SyncML based Application Management System for Mobile Devices (이동 단말을 위한 SyncML 기반 응용 관리 시스템의 설계 및 구현)

  • Park, Ji-Eun;Kim, Sang-Wook
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.1
    • /
    • pp.62-70
    • /
    • 2002
  • The purpose of this paper in that users can use mobile device applications more easily and efficiently through MoDAM (Mobile Device Application Management) system. MoDAM automates the process of web retrieval for obtaining mobile device applications and the process of installing or updating it on mobile devices and then supply users with these automated services in a step form by combining two separated processes. We implement a web agent conforming to OSD (Open Software Description) specification for automating software retrieval and downloading and also a mobile device based software management module conforming to SyncML (Synchronization Markup Language) specification for synchronizing common data between server and client. The method of automated software retrieval and management for mobile devices using these standard specifications minimizes users' interrupts and also can be applied to traditional several different mobile devices, operating systems or downloading web sites without platform dependent considerations.