• 제목/요약/키워드: Supply Current

검색결과 3,037건 처리시간 0.036초

The Development of High-Current Power Supply System for Electrolytic Copper Foil

  • Luo, An;Ma, Fujun;Xiong, Qiaopo;He, Zhixing
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.399-410
    • /
    • 2015
  • A 6.5 V/50 kA high-frequency switching power supply (HSPS) system composed of 10 power modules is developed to meet the requirements of copper-foil electrolysis. The power module is composed of a two-leg pulse width modulation (PWM) rectifier and a DC/DC converter. The DC/DC converter adopts two full-wave rectifiers in parallel to enhance the output. For the two-leg PWM rectifier, the ripple of the DC-link voltage is derived. A composite control method with a ripple filter is then proposed to effectively improve the performance of the rectifier. To meet the process demand of copper-foil electrolysis, the virtual impedance-based current-sharing control method with load current full feedforward is proposed for n-parallel DC/DC converters. The roles of load current feedforward and virtual impedance are analyzed, and the current-sharing control model of the HSPS system is derived. Virtual impedance is used to adjust the current-sharing impedance without changing the equivalent output impedance, which can effectively reduce current-sharing errors. Finally, simulation and experimental results verify the structure and control method.

Bi-2223 팬케익부하 충전용 히터-트리거 스위칭 장치의 설계 및 제작 (Design and Fabrication of Heater-triggered Switching System for the Charging of Bi-2223 Pancake Load)

  • 김영식;윤용수;배덕권;안민철;임대준;김호민;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.43-48
    • /
    • 2004
  • This paper deals with design and fabrication of heater-triggered switching system for the high-Tc superconducting (HTS) power supply with series-connected double-pancake load. Amongst all components, heater triggering is the most important element for the performance of HTS power supply. To fabricate the optimal heater-triggered system, its characteristics have been analysed through the simulation and expriment. The thermal analysis of switching parts of the Bi-2223 solenoid according to the heater input was carried out. Based upon the analysis, 8A electromagnet current and 1.5A DC Heater current were optimally derived, and 8s and 20s for the pumping period were selected in this experiment. In the experiment. the maximum pumping current reached about 24A with Bi-2223 pancake load of 6mH.

단자망을 이용한 직류전기철도 해석방안에 관한 연구 (A Study on Analysis Method of DC Electric Railroad using Terminal Network Analysis)

  • 이장무;장동욱;김재원;한문섭;정환수;김주락
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1913-1918
    • /
    • 2016
  • In order to analyze the power consumption pattern of the DC urban rail system, the method to obtain a solution establishing the current equation according to fixed position of the substation and varying position of the train is used. The proposed analysis method using the network analysis is to model the transfer function of the component constituting a direct current power supply system (dc substation, train, catenary) to the voltage and current. By multiplying the model formula consecutive, it can calculate the voltage and current of each element of power supply circuit and shows a simple case analysis.

포워드 컨버터의 노드확장에 의한 전도성 노이즈 감소에 관한 연구 (A Study on Reduction of Conducted-Noise by the Expanded Node of the Forward Converter)

  • 이희훈;권영안
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권7호
    • /
    • pp.374-379
    • /
    • 2006
  • The switch mode power supply is a source of EMI with other equipment as well as with its own proper operation because of rapid changes in voltages and currents within a switching converter. The EMI is transmitted in two forms: radiated and conducted. Conducted noise consists of two categories known as the differential mode and the common mode. Common mode noise current is a major source of EMI in the switch mode Power supply. Recently, a current balancing technique has been studied to reduce the common mode noise. This paper investigates the reduction of common mode noise according to a node expansion of the switch mode power supply which is based on a current balancing technique. In this paper, seven PCB patterns of the forward converter are manufactured and experimented.

Testability of Current Testing for Open Faults Undetected by Functional Testing in TTL Combinational Circuits

  • Tsukimoto, Isao;Hashizume, Masaki;Mushiaki, Yukiko;Yotsuyanagi, Hiroyuki;Tamesada, Takeomi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1972-1975
    • /
    • 2002
  • A new test approach based on a supply current test method is proposed for testing open faults in bipolar logic circuits. In the approach, only the open faults are detected by the supply current test method, which are difficult to be detected by functional test methods. The effectiveness of the approach is examined experimentally on open fault detection in TTL combinational circuits. The results shows that higher fault coverage can be established by applying a small number of test input vectors of the supply current test method after test vectors of functional test methods based on stuck-at models.

  • PDF

전류원 PWM 컨버터 / 인버터를 이용한 새로운 단조용 유도가열 전원장치의 설계 (Design of New Induction Heating Power Supply for Forging Applications Using Current-Source PWM Converter and Inverter)

  • 최승수;이창우;김인동
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1602-1610
    • /
    • 2018
  • Induction heating can convert electrical energy to thermal energy with high conversion efficiency and quick heating. Currently, a current source rectifier/inverter-fed parallel resonant circuit is widely used as an induction heating power supply for forging applications. However, the conventional induction heating power supplies composed of phase-controlled rectifier and SCR inverter have low efficiency and low power factor at input side, and require additional starting circuitry. So this paper proposes new induction heating power supply topologies for forging applications which have high power factor, high efficiency, and large output power. It also suggests detailed design guideline.

다목적댐의 가뭄 대비 용수공급 조정기준과 혼합 정수계획법에 의한 용수 감량 공급 기준의 비교 및 분석 (Analysis and comparison of the water supply adjustment guide and a hedging rule of reservoir operation derived from mixed-integer programming for water supply operation of a multi-purpose reservoir)

  • 진영규;정택문;이상호
    • 한국수자원학회논문집
    • /
    • 제54권6호
    • /
    • pp.443-452
    • /
    • 2021
  • 혼합정수 계획의 최적화 기법으로 유도한 '용수 감량 공급 기준'은 용수를 미리 감량 공급함으로써 가뭄 기간에 상대적으로 많은 물을 확보하여 저수지를 운영하는 기준이다. 우리나라의 다목적 저수지 운영에 적용하고 있는 현행 기준은 모의 운영 기법으로 유도된 '용수공급 조정기준'이다. 2003-2018년 기간의 저수지 유입량을 입력 자료로 하여, 합천 다목적댐 저수지의 모의 운영에 두 방법을 적용한 결과, 두 방법 모두 2015년부터 2018년까지 지속된 가뭄에 장기간 물 공급 부족이 발생하였다. 특히 2017년 하반기에 물을 전혀 공급하지 못하거나 간헐적으로 공급하는 기간이 지속해서 나타났다. 용수공급 조정기준은 '정상 용수공급 환원 기준 저수량'을 둠으로써, 2017년 7월에 용수공급 불가 상태에 이른 다음, 저수량이 정상 용수공급 환원 기준 저수량 보다 커지는 2018년 1월까지 용수공급을 중단하는 결과를 낳았다. 저수지에 물이 유입되어 저수량이 증가하는 상태에도 불구하고 물 공급을 중단하는 결과는 실행 상 개선이 필요하다. 현행 용수공급 조정기준과 용수 감량 공급 기준 모두 가뭄 단계별 용수의 감축 공급 개념을 과학적 수치로 나타낸 저수지 운영 기준으로서 유용하고 현실적이다. 그렇지만 위와 같이 몇 개월간 물을 전혀 공급하지 못하거나 간헐적으로 공급하는 저수지 모의 운영 결과를 개선하기 위하여, 현재 적용 중인 가뭄 단계별 물의 공급 축소량을 증가시킬 필요가 있다.

초전도 여자 코일을 이용한 초전도 Power Supply 제작 및 동작 특성 해석 (The Manufacture and Operational Characteristics Analysis of a Superconducting Power Supply by using Superconducting Excitation Coils)

  • 배준한;오윤상;송명곤;지창섭;김호민;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.190-192
    • /
    • 1996
  • This paper is a study on the rotating type of superconducting power supply(R.S.P.S.) with superconducting excitation coils. In this paper, a new idea of excitation coil is introduced to control the pole-flux in air gap. We manufactured the R.S.P.S. by using superconducting excitation coils and measured the charging current of superconducting load with respect to rotational speeds and excitational current. Through this experiment, 425A of maximum current was obtained a few minutes. It turned out that the charging rate of load current is proportional to rotational speeds and excitational current. Furthermore, it is found that it's possible to generate the charge current of thousands of amperes by using wires of larger critical current.

  • PDF

펄스파워 기술을 이용한 전류펄스 공급장치 (Electric current pulse supply unit use pulse power technique)

  • 박상국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.791-793
    • /
    • 2012
  • 본 논문에서는 경량합금 용해공정 상에서 발생되는 응고 조직의 불균일한 문제를 대전류 펄스파워 장치를 적용해서 해결하기위한 용도로 전류펄스 공급 장치를 개발했다. 펄스파워를 발생시키기 위한 전원공급용 스위치는 MOSFET 스위치를 사용했고, 게이트제어를 위한 신호로는 PWM 신호를 발생시켜 공급했다. 설계한 회로에 대해 시뮬레이션을 거쳐 PCB로 제작하여 최종적으로 전류펄스 공급 장치를 개발했다. 전원회로 시뮬레이션은 PSIM 소프트웨어를 이용해서 실시했다. 실험결과 개발한 시스템에서 출력되는 전류펄스 출력신호가 시뮬레이션 결과와 잘 일치함을 확인했다.

  • PDF

Automatic Control on Dosing Coagulant as to Stream Current

  • Oh, Sueg-Young;Byun, Doo-Gyoon;Hwang, Jae-Moon;Song, Hyun-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1318-1321
    • /
    • 2005
  • As recently raw water quality has been polluted as well as its quality has been remarkably varied according to season and region, the precise control of coagulant dosage is being keenly required in water treatment plants. The amount of coagulant is closely related to raw water quality such as turbidity, alkalinity, water temperature, pH, electrical conductivity, etc. Since the optimum quantity of chemicals is not yet finalized, so dosage rate must be decided by using jar test that takes one or two hours. Hereupon, the output signal of stream current and multi-regression on historical data were proposed to be applied to the coagulant dosing control. In consequence of applying the scheme to automatic determination of the dosage rate, it was testified that the determination of dosage rate was very effective in case it is performed as to real-time sensing of water quality and the output signal of stream current.

  • PDF