• 제목/요약/키워드: Supplementary Tie

검색결과 5건 처리시간 0.019초

보조 띠철근으로써 V-타이의 부착-미끄러짐 관계 실험 (Bond-Slip Tests of V-ties as a Supplementary Lateral Reinforcement)

  • 권혁진;양근혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.157-158
    • /
    • 2017
  • This tests examined bond stress-slip relationship of V-ties embedded into concrete as a supplementary lateral reinforcement proposed for ductility of concrete flexural members. The different leg shapes of V-ties were prepared as a test parameter. The V-tie with pressed end-legs exhibited 28% higher bond strength than the conventional V-ties, whereas bond stress-slip curves were insignificantly affected by the embedment length of V-ties.

  • PDF

기둥의 단면 확대보강을 위한 V-타이 보조 띠철근의 형상 제시 (Proposals of Reliable Shapes of Supplementary V-ties for Section Jacketing Method of Columns)

  • 권혁진;양근혁;심재일
    • 한국건축시공학회지
    • /
    • 제18권2호
    • /
    • pp.99-107
    • /
    • 2018
  • 이 연구의 목적은 기존 철근콘크리트 기둥의 내진보강을 위한 단면 확대보강공법에서 보조 띠철근으로써 배근할 수 있는 V-타이의 상세를 제시하는 것이다. 모두 24개의 직접 인발실험체에서 V-타이의 역학적 거동을 고려한 부착강도 관점에서 선택한 주요 변수는 V-타이의 형상, 묻힘길이 및 콘크리트 강도이다. 다양한 상세를 갖는 V-타이의 부착강도는 일반 V-타이의 부착강도 및 CEB-FIP 제안식과 비교하였다. 그 결과 보강단면의 두께가 기존 V-타이의 묻힘 길이[= max(75mm, $6d_b$)]보다 적은 기둥의 경우 단부 압착형의 V-타이가 보조 띠철근로 추천될 수 있었는데, 여기서 $d_b$는 V-타이로 사용된 철근의 직경이다.

철근콘크리트 기둥의 휨 연성에 대한 V-타이 보조띠철근의 효율성 평가 (Evaluation on the Effectiveness of Supplementary V-ties on Flexural Ductility of Reinforced Concrete Columns)

  • 이혜진;양근혁;곽민경
    • 콘크리트학회논문집
    • /
    • 제29권4호
    • /
    • pp.345-351
    • /
    • 2017
  • 이 연구에서는 철근콘크리트 기둥의 휨 연성에 대한 보조 띠철근으로서 ACI 318-14에서 제시하는 크로스타이의 대체로서 V-타이 보조 띠철근의 효율성을 평가하였다. 작용 축하중비를 주요 변수로 일정 축하중과 반복 횡하중을 받는 기둥에서 파괴모드 및 횡하중-횡변위 관계를 측정하였다. 기둥의 최대 휨 내력 이후, 크로스타이의 $90^{\circ}$ 갈고리가 서서히 열리면서 주철근의 조기 좌굴 및 코어 콘크리트의 심각한 손상을 동반한 반면, V-타이의 뽑힘 현상은 기둥의 파괴 시까지 나타나지 않았다. 최대 내력의 80% 시점에서 V-타이 기둥의 일손상 지수 값은 크로스타이 기둥에 비해 축력비가 0.25, 0.4 및 0.55일 때 각각 2.4배, 2.3배 및 5.2배 높았다. 즉, 기둥의 휨 연성에 대한 기존 크로스타이 대비 V-타이의 효율성은 축력비가 높을수록 현저하였다.

Provision of Two-area Automatic Generation Control by Demand-side Electric Vehicle Battery Swapping Stations

  • Xie, Pingping;Shi, Dongyuan;Li, Yinhong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.300-308
    • /
    • 2016
  • Application of demand-side resources to automatic generation control (AGC) has a great significance for improving the dynamic control performance of power system frequency regulation. This paper investigates the possibility of providing regulation services by demand-side energy storage in electric vehicle battery swapping stations (BSS). An interaction framework, namely station-to-grid (S2G), is presented to integrate BSS energy storage into power grid for giving benefits to frequency regulation. The BSS can be regarded as a lumped battery energy storage station through S2G framework. A supplementary AGC method using demand-side BSS energy storage is developed considering the vehicle user demand of battery swapping. The effects to the AGC performance are evaluated through simulations by using a two-area interconnected power grid model with step and random load disturbance. The results show that the demand-side BSS can significantly suppress the frequency deviation and tie-line power fluctuations.

도시철도 콘크리트궤도 목침목 분기기의 손상현황 (Damage Status of Turnout System with Wooden Sleeper of Concrete Track on Urban Transit)

  • 최정열;한경성;봉재근;장철주;정지승
    • 문화기술의 융합
    • /
    • 제5권4호
    • /
    • pp.379-385
    • /
    • 2019
  • 본 연구는 도시철도 콘크리트궤도 목침목 분기기의 손상현황 및 손상유형별 원인을 분석하고자 현장조사를 수행하였다. 또한 약 24년간의 분기기 유지관리이력을 열차 통과톤수와 연계하여 운영 호선별로 구분하여 손상발생빈도와 연계분석하고 현재까지 수행되어온 손상항목별 궤도보수내용의 적정성을 비교 분석하였다. 도시철도 콘크리트 도상에 적용된 목침목 분기기의 특성상 목침목 하부에 삽입되어 있는 침목방진패드의 성능유지가 중요하다. 현장조사결과 목침목 분기기 궤도구조의 적정탄성 수준 부족에 따른 손상 및 다양한 유형의 레일손상이 조사되었으며, 레일의 손상은 독립적인 손상이 아닌 다른 궤도구성품의 손상에서 기인되어 유발되는 경우도 다수 발견되었다. 분기기 궤도구성품별 손상빈도 분석결과, 손상발생빈도는 레일, 타이플레이트, 나사스파이크, 목침목 순으로 나타났으며 이를 바탕으로 목침목 분기기 궤도구조의 주요 손상유형은 목침목의 변형에 따른 나사스파이크와 타이플레이트의 고정상태불량에서 기인된 손상이 주요 손상유형으로 분석되었다. 연구결과, 분기기에 적용된 목침목의 변형은 레일체결장치구성품의 고정상태 불량을 초래하고 이로 인한 연계손상이 유발될 수 있음을 현장조사결과를 바탕으로 분석하였다. 또한 분기기의 중점 점검항목 및 현행 분기기 점검 시트의 보완점을 도출하여 개선 안을 제시하였다.