• 제목/요약/키워드: Supplemental equipment

검색결과 9건 처리시간 0.025초

부가적인 전기 장비품의 인증 방안 (A Study on the Certification of Miscellaneous Non-Required Electrical Equipment)

  • 김일영;서장원
    • 항공우주시스템공학회지
    • /
    • 제1권4호
    • /
    • pp.1-6
    • /
    • 2007
  • The interest about the installation and certification for miscellaneous non-required electrical equipment is being increased in the domestic aviation industries. In this paper, the minimum applicable requirements in Airworthiness Standard and the acceptable means of compliance which can be applied to installation and certification for miscellaneous non-required electrical equipment is being researched. As a case study, galley certification procedures are presented by electrical load analysis, installation of warning devices and installation requirements.

  • PDF

Optimal oxygen saturation in premature infants

  • Chang, Mea-Young
    • Clinical and Experimental Pediatrics
    • /
    • 제54권9호
    • /
    • pp.359-362
    • /
    • 2011
  • There is a delicate balance between too little and too much supplemental oxygen exposure in premature infants. Since underuse and overuse of supplemental oxygen can harm premature infants, oxygen saturation levels must be monitored and kept at less than 95% to prevent reactive oxygen species-related diseases, such as retinopathy of prematurity and bronchopulmonary dysplasia. At the same time, desaturation below 80 to 85% must be avoided to prevent adverse consequences, such as cerebral palsy. It is still unclear what range of oxygen saturation is appropriate for premature infants; however, until the results of further studies are available, a reasonable target for pulse oxygen saturation ($SpO_2$) is 90 to 93% with an intermittent review of the correlation between $SpO_2$ and the partial pressure of arterial oxygen tension ($PaO_2$). Because optimal oxygenation depends on individuals at the bedside making ongoing adjustments, each unit must define an optimal target range and set alarm limits according to their own equipment or conditions. All staff must be aware of these values and adjust the concentration of supplemental oxygen frequently.

지중 및 보조루프의 2차 유체 유량 분배비를 통한 하이브리드 지열히트펌프의 성능 최적화 연구 (Performance Optimization of a Hybrid Ground Source Heat Pump According to Secondary Flow Distribution Ratio between the Ground and the Supplemental Loop)

  • 이주성;박홍희;김원욱;김용찬
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.102-110
    • /
    • 2012
  • The objective of this study is to improve the performance of a hybrid ground source heat pump (HGSHP) by optimizing the flow distribution ratio of secondary fluid flow rate between a ground loop and a supplemental loop. Initially, a conventional ground source heat pump (GSHP) was tested to determine an optimum flow rate of the secondary fluid. Based on the selected optimum value, the HGSHP was also tested by varying the flow distribution ratio of the secondary fluid flow rate between the ground loop and the supplemental loop, such as 9:1, 7:3, 5:5, and 3:7. The results showed that the optimum flow distribution ratio of the secondary fluid flow rate was 7:3. The COP of the HGSHP was improved by 19% over the GSHP at a flow distribution ratio of 7:3 and an entering water temperature of $40^{\circ}C$.

초음파 스캐닝을 활용한 지능형 건설기계 충돌방지 기술 (Intelligent Collision Prevention Technique for Construction Equipment using Ultrasound Scanning)

  • 이재훈;황영서;양강혁
    • 한국건설관리학회논문집
    • /
    • 제22권5호
    • /
    • pp.48-54
    • /
    • 2021
  • 고용노동부의 2020년 산업재해 사고 사망 통계 발표에 따르면 최근 5년간 발생한 업무상 사고 사망 재해의 절반 이상이 건설업에서 발생하고 있다. 그중 건설기계와 관련된 충돌 및 협착 사고가 사망 재해의 큰 부분을 차지하고 있다는 것을 알 수 있다. 정부는 건설 현장에서 발생하는 사고를 예방하기 위해 "건설안전특별법" 발의, 사고 예방을 위한 새로운 기술의 도입 장려 등 큰 노력을 기울이고 있지만, 여전히 건설 현장에서 수많은 안전사고가 발생하고 있다. 이에 본 연구는 초음파 스캐닝 기술을 통해 반경 내 대상의 종류와 위치를 인식하여 건설기계와 작업자 간의 충돌사고를 예방할 수 있는 기술을 개발했다. 본 연구는 파일럿 실험을 수행하였으며, 결과 분석을 통해 대상 인식과 위치 추정 모두에서 높은 정확도로 기술의 실현 가능성을 증명하였다. 개발한 기술은 건설 현장에서 발생하는 충돌사고를 예방하고, 자동화된 건설기계 충돌사고 예방 기술 개발에 이바지할 수 있을 것으로 기대된다.

수송류 항공기용 금속계 제동패드의 역설계 절차 (Reverse Engineering Procedure of Metal Brake Pad for Part 25 Aircraft)

  • 김민지;김경일;김경택
    • 한국항행학회논문지
    • /
    • 제27권5호
    • /
    • pp.621-628
    • /
    • 2023
  • 본 연구는 항공기용 부품 및 장비품 중 치명성 부품인 수송류 항공기용 금속계 제동패드의 부품등제작자증명 및 부가형식증명을 위한 원 부품 등과 개발품의 설계 동일성 입증을 위한 역설계 절차를 도출하였다. 역설계 절차에 대한 규정은 우리나라의 경우 부품등제작자증명 지침에 의해 규정되며, 미국의 경우 AC No; 21.303-4에 규정되어 있다. 제동패드의 역설계 절차는 각 구성품별 샘플 수량, 치수공차, 기계적 물성 측정, 자재, 무게 및 부피특성 등의 동일성 확인 항목을 선정하여 각각의 세부 절차를 정의하였다. 아울러 우리나라 및 미국의 연방항공규정을 분석한 결과, 우리나라의 경우 수송류 항공기용 제동장치의 기술표준품 표준서 및 비행시험과 관련된 규정의 제정이 필요하다.

실험용 쥐의 마취 (Anesthesia for the Experimental Rats)

  • 최희락;고종현;이해범;이준모
    • Archives of Reconstructive Microsurgery
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2013
  • Rats and mice are commonly used in experimental laboratories and anesthetic drugs are important for researchers to understand the details. Administration of fluids helps to stabilize the experimental animals before anesthesia via intravenously through the lateral vein in rats and in case of difficulty in catheterization and maintenance, fluids are usually administered as boluses. Large volumes of cool fluids will rapidly lead to hypothermia and all parenteral fluids must be warmed to body temperature before administration. Premedication with a sedative may ease induction with volatile anesthetic drugs. The first choice for rodent anesthesia is complete inhalational anesthesia. The second option is using injectable anesthesia. Recovery from the volatile agents that have been used rapid when the agent is no longer administered. Anesthetic monitoring equipment is an infant-size bell sthethoscope that can be used to ausculate the heart and lungs. Supplemental heating should be provided to reduce the heat loss supply and maintain core body temperature. The kinds of drugs, characteristics, route of administration and care after surgery were reviewed and summarized from the references. Anesthetic drugs, maintenance, monitoring and aftercare are important in the laboratories to keep the animal safe in all experimental procedures.

  • PDF

공항철도연계 구간의 고속열차(KTX)와 전동열차(AREX) 혼용운용에 따른 ATP지상설비간 상호간섭 영향에 관한 연구 (Study on the mutual interference of mixed mode operation between KTX and AREX train at the airport linked line)

  • 김봉수;송인근
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.23-30
    • /
    • 2016
  • 공항 철도 연계 시설 확충 사업에 따라 수색역구내에서 공항 철도로 연결선(L=2.2km)을 건설하고 신호 시스템 및 정거장을 개량하여 경의선 수색역에서 공항 철도로 경부선 및 호남선 고속열차(KTX)를 직결 운행 할 수 있도록 하였다. KTX/AREX 열차의 혼용 운행에 따른 AREX 전동 열차의 신호 시스템은 기존과 동일한 ATC /ATO 방식으로 운행하고 KTX 고속 열차는 ERTMS/ETCS L1 ATP 방식을 신설하여 운행하기로 하였으나 "고속 열차(KTX)와 공항 철도의 지상 신호 설비" 간 및 "공항 철도 차량(AREX)과 고속 열차용 ATP 시스템 지상 설비간 상호 간섭 등의 문제점으로 인하여 고속 열차 운행이 불가능하게 되었다. 이에 공항 철도 비콘과 KTX 열차용 발리스의 특성을 비교 분석한 결과 상호 간섭에 대한 기술적 보완이 필요함을 확인하게 되었다. 따라서 이러한 복합적인 문제의 해결과 기술적 타당성을 확인하기 위해 3가지 유형의 시험 모듈로 실제의 열차를 이용하여 시험을 함으로서 "고속열차(KTX)와 공항 철도 지상 신호 설비간" 및 "공항 철도 전동차(AREX)와 고속 열차용 ATP시스템 지상 설비" 간 상호 간섭 등의 문제점을 해소하고자 한다.

Comparison of Two Vitrification Methods of In Vitro Development Oocytes Collected from Porcine Antral Follicles Using Open Pulled Straw (OPS) Techniques

  • An, Mihyun;Hong, Daewuk;Son, Dongsoo;Seok, Hobong
    • 한국수정란이식학회:학술대회논문집
    • /
    • 한국수정란이식학회 2002년도 국제심포지엄
    • /
    • pp.84-84
    • /
    • 2002
  • The advantages of the OPS techniques(Vajta G et al, Mol Reprod Dev 51: 53-58,1998) give 1) high survival rates of various types of eggs, 2) quick and simple process, 3) inexpensive equipment and reduced chilling injury. The efficiency of IVM/IVF technique in the porcine species is relatively lower than that obtained in other species such as ruminants. Two experiments were designed to investigate the effects of in-vitro fertilization of porcine oocytes matures using different OPS protocol for chilling and warming of vitrification. Porcine oocytes from ovaries collected at abattoir were matured for 44 hours in TCM199 Earle's salt supplemental with pyruvate, pff, L-cysteine, hormones and gentamycin. Oocytes were denuded and fertilized with frozen boar semen by common method. Porcine embryos produced routinely by in-vitro culture system of NCSU23 medium. The vitrification and the warming were conducted by OPS method with the glass micropipette instead of straw vessels and modified the protocol of G.Vajta(1999). In Exp 1, Chilling/Warming:Holding Medium(HM)+EG+DMSO/HM +sucrose Medium(SM) at 39$^{\circ}C$ warm stage. In Exp 2, : PBS+CS+EG+Ficoll+ Trehalose/PBS+Trehalose at 25$^{\circ}C$ stage. Filling, freezing, packing, thawing out and further culturing were performed to follow the basic protocol of G Vajta. During IVM-lVC and post-warming, fertilization parameter and developmental potential were compared to and statistically analysed. It was not significantly different from Exp 1 and Exp 2 but 25$^{\circ}C$ of stage was slightly higher on the morula/blastocyst forming rate and better atmosphere for worker than that at 39$^{\circ}C$ stage.

  • PDF

융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발 (Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition)

  • 조용귀;표성재;김봉수;신채호;조진우;김창호
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.84-89
    • /
    • 2013
  • PET-CT (Positron Emission Tomography-Computed Tomography)의 융합영상(Fusion image)에서 긴 영상 획득 시간에 의한 환자의 움직임은 융합영상에서 부적합한 결과로 나타나 영상의 질과 진단에 큰 영향을 준다. 의료장비 회사에서 제공하는 팔 지지대는 환자 자세에서의 편의성과 안전성을 고려하지 않아 PET/CT를 검사하는 동안 팔과 머리의 움직임 때문에 뇌기저부의 영상 결손이 생기고 머리의 좌우, 상하 움직임으로 인하여 재촬영이 빈번하다. 이에 우리는 두경부와 팔의 움직임을 최소화할 수 있는 환자보정기구를 개발하여 PET/CT 촬영 시 환자에게 편의성과 안전성을 제공하고 환자의 움직임으로 인한 재촬영을 줄이고자 한다. 2012년 6월부터 7월까지 PET Torso 검사를 위해 핵의학과에 내원하는 환자들 중 움직임에 불편함이 전혀 없는 환자 20명과 어깨 통증으로 팔을 올리기가 불편한 환자 20명을 대상으로 Patient Holding System (PHS)와 팔의 경사도($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$)를 변화시켜 가장 편안한 자세와 경사도를 선정 하였다. 또한 지지대 재질의 투과성에 대하여 유관업체의 검증을 하였고, 환자의 머리와 팔을 밴드(벨크로 형태)로 고정하여 이에 대한 편의성을 질의하였다. 그리고 움직임에 의한 재촬영 빈도를 알아보기 위해 2012년 1월부터 12월까지 PET Torso를 시행한 환자들 중 환자보정기구 사용 전/후 재촬영 여부를 분석하였다. 움직임에 불편이 전혀 없는 환자에서는 18명이 PHS와 팔의 각도가 $29^{\circ}$에서 가장 편안함을 느낀다고 답하였으며, 2명은 각각 $27^{\circ}$, $31^{\circ}$이라고 답하였다. 어깨 통증을 느끼는 환자에서는 15명이 $31^{\circ}$에서 가장 편안함을 느낀다고 답하였고, $33^{\circ}$에서 2명, $35^{\circ}$에서 3명이었다. 이를 위해 손잡이 부분이 상, 하 움직임이 가능하도록 제작하였다. 환자보정기구 재질의 투과성은 검증된 상태이며, 환자보정기구 자체의 움직임을 방지하기 위하여 PHS와 보정기구를 밴드(벨크로 형태)로 고정시켰다. 두경부의 움직임을 최소화할 수 있는 홈을 만들고 머리를 고정할 수 있게 고정밴드를 부착 하였고, 손목 및 전완과 상완의 움직임을 제한할 수 있는 고정밴드를 부착하여 팔의 흔들림으로 인한 움직임을 최소화 하였다. PET Torso 촬영 시 움직임에 의한 재촬영 빈도는 환자고정기구 사용 전 10.56% (191건/1,808명), 사용 후 2.77% (48 건/1,732명)로 7.79%의 발생 빈도를 줄일 수 있었다. 최근 의료 환경의 변화와 혁신으로 고가의 영상검사가 늘어남에 따라 고객이 요구하는 차별화된 서비스 제공은 필수적이다. 따라서 PET/CT를 검사하는 동안 환자의 편안함과 안전성을 확보하기 위해 인체공학적인 환자보정기구를 제공하여야 한다. 따라서 본 연구를 통해 PET Torso 검사 시 환자의 체형과 상황에 따라 인체공학적 경사도를 상, 하 조절할 수 있는 환자보정기구를 제작하였으며, 팔의 움직임에 의한 뇌기저부의 영상결손을 줄이고 머리의 움직임으로 인한 재촬영을 줄일 수 있었다.

  • PDF