• 제목/요약/키워드: Superparamagnetic iron oxide

검색결과 46건 처리시간 0.025초

Implications of SPION and NBT Nanoparticles upon In Vitro and In Situ Biodegradation of LDPE Film

  • Kapri, Anil;Zaidi, M.G.H.;Goel, Reeta
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권6호
    • /
    • pp.1032-1041
    • /
    • 2010
  • The comparative influence of two nanoparticles [viz., superparamagnetic iron oxide nanoparticles (SPION) and nanobarium titanate (NBT)] upon the in vitro and in situ low-density polyethylene (LDPE) biodegradation efficiency of a potential polymer-degrading microbial consortium was studied. Supplementation of 0.01% concentration (w/v) of the nanoparticles in minimal broth significantly increased the bacterial growth, along with early onset of the exponential phase. Under in vitro conditions, ${\lambda}$-max shifts were quicker with nanoparticles and Fourier transform infrared spectroscopy (FTIR) illustrated significant changes in CH/$CH_2$ vibrations, along with introduction of hydroxyl residues in the polymer backbone. Moreover, simultaneous thermogravimetric-differential thermogravimetry-differential thermal analysis (TG-DTG-DTA) reported multiple-step decomposition of LDPE degraded in the presence of nanoparticles. These findings were supported by scanning electron micrographs (SEM), which revealed greater dissolution of the film surface in the presence of nanoparticles. Furthermore, progressive degradation of the film was greatly enhanced when it was incubated under soil conditions for 3 months with the nanoparticles. The study highlights the significance of bacteria-nanoparticle interactions, which can dramatically influence key metabolic processes like biodegradation. The authors also propose the exploration of nanoparticles to influence various other microbial processes for commercial viabilities.

경동맥 경화판의 고해상도 자기공명영상 (High-resolution MR Imaging of Carotid Atherosclerotic Plaques)

  • 신원선;김성목;최연현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권2호
    • /
    • pp.97-102
    • /
    • 2012
  • 고해상도 경동맥 자기공명영상(MRI)을 이용하여 경화판 특성을 파악할 수 있다. MRI는 경화판의 활동성 염증이나 경화판내 출혈을 비침습적으로 진단할 수 있는 능력이 있다. 3T MRI는 1.5T MRI에 비해 신호 대 잡음비와 대조도 대 잡음비가 높다. 동맥벽의 면적이나 표준화된 동맥벽 면적을 MRI로 측정하면 약물 치료 후 반응을 평가할 수 있다. 결론적으로 고행상도 MRI는 일과성 허혈이나 뇌졸중을 발생하기 쉬운 경화판의 진단과 치료 후 평가에 유용하다.

망간-철산화물 나노입자의 뫼스바우어 분광 연구 (Mössbauer Studies of Manganese Iron Oxide Nanoparticles)

  • 현성욱;심인보;김철성;강경수;박주식
    • 한국자기학회지
    • /
    • 제18권1호
    • /
    • pp.24-27
    • /
    • 2008
  • Polyol법을 이용하여 $MnFe_2O_4$ 나노입자를 제조하고, X-선 회절기(XRD)와 진동시료형 자화율 측정기(VSM)를 이용하여 결정학적 및 거시적인 자기적 특성을 분석하였고, 뫼스바우어($M\"{o}ssbauer$) 분광실험을 통하여 $MnFe_2O_4$ 물질의 초미세 상호작용에 대한 연구를 수행하였다. 고분해능 투과형 전자 현미경(High Resolution Transmission Electron Microscope; HRTEM)을 이용하여 입자의 크기를 분석한 결과, 대부분의 입자크기가 $6{\sim}8$ nm 정도의 분포를 가지는 매우 균일한 입자로 형성되었음을 확인할 수 있었다. X-선 회절실험의 분석 결과, $a_0=8.418{\pm}0.001{\AA}$의 격자상수를 가지는 입방정형의 스피넬 구조로써 그 공간군이 Fd3m 임을 확인하였다. 상온에서의 VSM 측정결과 강한 초상자성 거동을 보였고, 뫼스바우어 분석결과로 상온에서 초상자성 영향에 따른 요동현상이 나타남을 관측할 수 있었다. 4.2K에서는 6개의 공명흡수선이 2 set으로 존재하고 초미세 자기장 값($H_{hf}$)이 A-site의 경우 498 kOe, B-site의 경우 521 kOe 로 분석되었다.

Diagnostic Effectiveness of USPIO versus Gadolinium Based MRI for Axillary Metastasis in Breast Cancer: A Meta-analysis

  • Kim, Yoonseok;Jae, Eunae;Park, Junggu
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권1호
    • /
    • pp.37-46
    • /
    • 2015
  • Purpose: This report compared the diagnostic effectiveness between ultrasmall superparamagnetic iron oxide (USPIO) and gadolinium (Gd) based magnetic resonance imaging (MRI) for differentiation of axillary status in breast cancer patients. Materials and Methods: The present authors performed a meta-analysis of previous studies that compared USPIO or Gd based MRI with histological diagnosis after surgery or biopsy. We searched PubMed, EMBASE, Cochrane Library, ScienceDirect, SpringerLink, Ovid databases and references of articles to identify studies reporting data until December 2013. Pooled sensitivity and specificity were calculated for every study; summary receiver operating characteristic and subgroup analysis was done. Analyses of study quality and heterogeneity were also assessed. Results: There were 14 publications that met the criteria for inclusion in our meta-analysis. USPIO based MRI showed 0.83 (95% CI: 0.75-0.89) and 0.97 (95% CI: 0.94-0.98) for pooled sensitivity and specificity, respectively. Gd based MRI represented pooled sensitivity and specificity of 0.61 (95% CI: 0.55-0.67) and 0.90 (95% CI: 0.87-0.92) for each. Overall weighted area under the curve for USPIO and Gd based MRI were 0.9563 and 0.9051, respectively. Conclusion: USPIO based MRI had a tendency toward high pooled sensitivity and specificity in detection of axillary metastases for breast cancer. This result may mean that USPIO based MRI could be used as complementary modality to differentiate axillary status more precisely, and assist in the decision-making process regarding possible invasive procedures, such as sentinel node biopsy.

간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review (Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

간의 3T 자기공명영상에서 초상자성산화철 조영증강 급속호흡정지영상기법들간의 양적 및 질적 비교평가 (Ferucarbotran-Enhanced Hepatic MRI at 3T Unit: Quantitative and Qualitative Comparison of Fast Breath-hold Imaging Sequences)

  • 조경은;유정식;정재준;김주희;김기황
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권1호
    • /
    • pp.31-40
    • /
    • 2010
  • 목적: 간의 국소병변에 대한 3T 자기공명영상에서 초상자성산화철 조영증강영상을 얻기 위한 여러 급속호흡정지대열들의 상대적 가치를 평가하고자 하였다. 대상 및 방법: 간의 자기공명영상을 시행하였던 환자들 중 한 개 이상의 악성 고형병소를 가진 102명의 연속으로 모은 환자들을 대상으로 초상자성산화철 조영제의 정맥주사 후 촬영한 3종류의 각각 다른 에코시간(2.4 msec [GRE_2.4], 5.8 msec [GRE_5.8], and 10 msec [GRE_10])을 갖는 $T2^*$ 강조 경사에코영상들과 하나의 T2 강조 고속스핀에코영상(TSE)을 비교하였다. 두 명의 관찰자가 독립적으로 간의 윤곽, 혈관지표, 인공물, 병변의 명확도에 대해 각각 4점 스케일로 질적분석을 시행하였다. 양적분석을 위해 1 cm 이상의 크기를 갖는 170개의 병변들(간세포암 107개, 담도암 9개, 간전이암 54개)에 대하여 대조도잡음비를 측정하였다. 결과: GRE_5.8은 간윤곽, 혈관지표, 인공물에 대해 질적으로 가장 높은 점수를 받았으며(p<.001) 간 병변의 명확도는 GRE_5.8과 GRE_10간에 유의한 차이가 없었다(p=.414). 전체적으로 평균 대조도잡음비는 GRE_10($24.4{\pm}14.5$), GRE_5.8($14.8{\pm}9.4$), FSE($9.7{\pm}6.3$), GRE_2.4($7.9{\pm}6.4$)의 순으로 높았으며(p<.001), 영상기법에 상관없이 담관암과 전이암의 평균 대조도잡음비가 간세포암에 비해 높았다(p<0.05). 결론: 3T 기기에서 악성 고형 간 병변의 진단을 위한 초상자성산화철 조영증강 급속 호흡정지기법들 중 5.8 msec의 중등도의 에코시간을 갖는 경사에코영상은 10 msec의 에코시간에 비해 대조도잡음비가 낮지만 전체적인 양적 및 질적 평가를 종합하여 볼 때 가장 우수한 영상을 제공할 수 있다.