• 제목/요약/키워드: Superheat control

검색결과 63건 처리시간 0.04초

R134a를 이용한 냉동장치의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristics of Refrigeration System Using R134a Refrigerating System)

  • 김진현;김종길;김성배;하옥남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2188-2193
    • /
    • 2007
  • Since the use of CFCs and HCFCs refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the R134a gas to study the performance characteristic from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1.5 MPa to 1.6 MPa by 0.05 MPa and for superheat temperature from 0$^{\circ}C$ to 5$^{\circ}C$ by 1$^{\circ}C$ at each condensing pressure. As a result of experiment, when the superheat temperature is 1$^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

  • PDF

고밀도 열교환기를 이용한 $NH_3$냉동장치의 성능 특성 연구 (The Study on Performance Characteristics of NH3 Refrigeration System Using Optimum Heat Exchanger)

  • 이승재;전상신;권일욱;이종인;하옥남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1276-1281
    • /
    • 2004
  • Nowadays CFCs and HCFCs refrigerants are restricted because it cause depletion of ozone layer. Accordingly, this experiment apply the ammonia gas and not CFCs and HCFCs for refrigerant to study the performance characteristic from the superheat control and improve the energy efficiency from the high performance. The condensing pressure of refrigeration system is increased from 15.0bar to 16bar by 0.5bar and superheat temperature is increased from $0^{\circ}C$ to $10^{\circ}C$ by $1^{\circ}C$ at each condensing pressure. As the result of experiment, when the superheat temperature is $0^{\circ}C$ at each condensing pressure, the refrigeration system has the high performance.

  • PDF

$NH_3$ 냉동장치의 과열도 변화에 의한 성능 특성 연구 (The Study on Performance Characteristics of Superheating the Suction Vapor in $NH_3$ Refrigeration System)

  • 권일욱;하옥남
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.756-761
    • /
    • 2004
  • Since the use of CFC and HCFC refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the NH$_3$ gas to study the performance characteristics from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 14.5 bar to 16.0 bar by 0.5 bar and for superheat temperature from $0^{\circ}C$ to 1$0^{\circ}C$ by 1$^{\circ}C$ at each condensing pressure. As a result of experiment, when the superheat temperature is 1$^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

멀티형 공조/냉동시스템의 증발기 과열도 제어 (Evaporator Superheat Control of a Multi-type Air-conditioning/Refrigeration System)

  • 김태섭;홍금식;손현철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.712-717
    • /
    • 2001
  • This paper investigates the control problem of evaporator superheat, i.e., the difference between the temperature of the refrigerant at the entrance region of an evaporator and that at the exit region, for multi-type air-conditioning/refrigeration systems. Mathematical equations describing the characteristics of compressor, condenser, evaporator, and electronic expansion valve are first derived. Then, the transfer functions from the current input of the electronic expansion valve to wall temperatures of evaporator tube at two-phase region and superheated region, respectively, are derived. The stability and performance of the closed loop system with a PI controller are analyzed by Nyquist stability criterion. Simulation results are provided.

  • PDF

전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성 (Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree)

  • 백승문;문춘근;김현우;정석권;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.282-288
    • /
    • 2010
  • 본 연구는 전자팽창밸브의 개도변화에 따른 가변속 수냉각기의 용량제어 특성에 관한 논문이다. 인버터에 의한 가변속 압축기를 사용한 냉각기를 최적으로 제어하기 위한 선행 연구이며 압축기 회전수별로 제어대상인 전자팽창밸브를 조절하여 증발기 출구의 과열도를 일정한 값으로 제어함으로써 최적의 냉각능력을 얻을 수 있는 과열도 값을 찾는 것을 목표로 하였다. 본 실험의 결과 압축기 회전속도가 일정할 때 팽창 밸브의 개도변화에 따라서 냉각능력이 최대가 되는 지점의 개도량을 실험을 통해서 파악할 수 있었다.

현대제어 이론을 이용한 냉동공조기의 정밀 온도제어 (Precise temperature control by modern control method on the refrigerator and air conditioner)

  • 한정만;유휘룡;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1213-1216
    • /
    • 1996
  • This paper describes a precise temperature control method for refrigerating and air conditioning systems. The control technique is based on the optimal servo control design method and the control algorithm is implemented on a personal computer. To control the precise temperature, two actuators such as an inverter for the compressor speed control and a stepping motor for regulating the expansion valve are used. The superheat and evaporator temperatures are chosen as the system output. So a multivariable system which has two inputs and two outputs to be controlled. The complicative model is identified by using an ARX(Auto Regressive eXogenous) model and the controller is designed by using the Matlab software.

  • PDF

텐덤형 냉방시스템의 안전운전을 고려한 압축기와 전자팽창밸브 제어 (Control of Compressors and Electronic Expansion Valve considering the Safe Operation of a Tandem-type Air-conditioning system)

  • 한도영;김재현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.675-680
    • /
    • 2006
  • Capacities of a tandem-type air-conditioner may be modulated by turning on and off of multiple compressors, and adjusting the position of a electronic expansion valve. In this study, control algorithms for compressors and a electronic expansion valve were developed by using fuzzy logics. The pressure control algorithm was also developed for the safe operation of compressors. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature,

  • PDF

텐덤형 냉방시스템의 압축기와 전자팽창밸브 제어 (Control of Compressor and Electronic Expansion Valve for a Tandom-type Air-conditioner)

  • 정남철;한도영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.469-473
    • /
    • 2005
  • Capacities of a tandom-type air-conditioner may be modulated by turning on/off multiple compressors and adjusting positions of a electronic expansion valve. In this study. control algorithms for compressors and a electronic expansion valve were developed by using fuzzy’ logics. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature.

  • PDF

The Study on the Performance Characteristics due to the Degree of Superheat in $NH_3$ Refrigeration System III - The Comparison of Heat Exchanger Types -

  • Hong Suck-Ju;Ha Ok-Nam;Lee Kyu-Tae;Ha Kyung-Soo;Jeong Song-Tae;Hong Seong-In;Yun Kab-Sig;Kim Yang-Hyun;Kwon Il-Wook;Lee Jong-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권1호
    • /
    • pp.7-13
    • /
    • 2006
  • Because the usage of CFC and HCFC based refrigerants are restricted due to the depletion of ozone layer, the $NH_3$ gas, in the experiment is evaluated to the performance characteristics for the superheat control to improve the energy efficiency. The experiment is carried out about the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa through the degree of superheat from 0 to $10^{\circ}C$ at each condensing pressure. As a result, in the case of shell and tube type of heat exchanger, the COP is more efficient than other cases at the degree of superheat $1^{\circ}C$ at each condensing pressure. In the case of shell and disk type of heat exchanger, the COP is the most efficient at the degree of superheat 0.

오일쿨러의 고정밀 온도 제어를 위한 PI 및 피드포워드 제어기 설계 (Design of PI and Feedforward Controller for Precise Temperature Control of Oil Cooler System)

  • 변종영;정석권
    • 동력기계공학회지
    • /
    • 제14권6호
    • /
    • pp.89-95
    • /
    • 2010
  • This paper deals with design method of proportional-integral(PI) and feedforward controller for obtaining precise temperature and high energy efficiency of oil cooler system in machine tools. The compressor's speed and opening angle of an electronic expansion valve are controlled to keep reference value of temperature at oil outlet and superheat of an evaporator. Especially, the feedforward controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.l^{\circ}C$ and maximum overshoot $0.2^{\circ}C$ under abrupt disturbances.