• Title/Summary/Keyword: Superficial Heat

Search Result 43, Processing Time 0.019 seconds

Influence of Superficial Heat and Deep Heat for Lumbo-sacral Segment on H-Reflex (흉요추부의 표재열 및 심부열 적용이 H 반사의 변화에 미치는 영향)

  • Yoon, Se-Won;Lim, Young-Eun;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.1-9
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate influence of superficial heat and deep heat for lumbo-sacral segment on H-reflex. Methods: Subjects of this research were 12 normal men and women (6 men and 6 women) and they were assigned to superficial heat group (6) and deep heat group (6). Heat treatment was applied between Th12-L2 by placing them at prone posture. superficial heat was applied for 20 min at 30 cm height with infrared lamp. Deep heat was applied for 20 mm at 5 cm height with 100 watt of microwave diathermy. H-reflex used diagnostic electromyography, active electrode was placed at muscle belly of medial gastrocnemius muscle at prone posture and electrical stimulation was given to posterior tibial nerve. Measurement was made before and after experiment and 10 min. and 20 min. after experiment. All data were analyzed with window 12.0 program, comparison of differences among measured items of groups according to repeated measurement was made with repeated measures ANOVA and significance level a was 0.05. Results: M latency at latency analysis showed little changes at two groups. H latency was reduced a little immediately after experiment and recovered to original state, there was significant difference. In analysis of amplitude, Mmax amplitude showed rise a little immediately after.

  • PDF

Changes of Pre-Auricular Cutaneous Blood Flow and Skin Temperature after Dry Heat Therapy and Moist Heat Therapy (건열요법과 습열요법 적용후 전이부 표층부 혈류량과 피부온도의 변화)

  • Hong, Yong-Jae;Kim, Cheul;Park, Moon-Soo;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.47-57
    • /
    • 2006
  • The purpose of this study was to assess the effects of the superficial heat therapy on the cutaneous blood flow and the skin temperature at pre-auricular region. Two types of the superficial heat therapy-moist hot pack & infrared lamp- were applied to 20 healthy subjects(male: 10, female: 10). For each subject, the two parameters of cutaneous blood flow and skin temperature were measured before and after heat therapy, using laser doppler flowmetry(LDF). The author analyzed the differences of the effects between the two therapies and also characteristics of responsiveness between the two parameters. The results were as follows : 1. The two parameters were significantly increased after both superficial heat therapies. 2. Skin temperature showed a maximum peak immediately after both superficial heat therapies, but cutaneous blood flow showed a maximum peak 4 minutes after both superficial heat therapies. 3. Increased cutaneous blood flow after application of moist hot pack lasted longer than infrared lamp. 4. Increased skin temperature after both superficial heat therapies lasted for 60 minutes, but increased skin temperature after infrared lamp decreased more rapidly than moist hot pack. 5. Amount of changes in cutaneous blood flow after infrared lamp was larger in female than in male, but no significant gender difference was found since 20 minutes after infrared lamp. Both moist hot pack and infrared lamp showed favorable effectiveness in raising cutaneous blood flow and skin temperature. Moist hot pack was slightly superior in maintaining this effect.

Effect of Heat Therapy to Superficial and Deep Body Temperatures according to Applying Dry and Moist Heats on Shoulder and Thigh (어깨와 대퇴부위에 건열과 습열 적용이 피부온도와 심부체온에 미치는 영향)

  • Lim, Nan-Young;Jeong, Hyeon-Cheol;Lee, Seung-Won;Kim, Woo-Jin
    • Journal of Korean Biological Nursing Science
    • /
    • v.13 no.3
    • /
    • pp.269-275
    • /
    • 2011
  • Purpose: This study was designed to help preparing the evidence-based data for the manual of heat applications by finding the differences of superficial and core temperatures after applying dry and moist heats on shoulder and thigh. Methods: Moist and dry heats were alternately applied on the 33 subjects a day apart from May 15, 2010 through June 9, 2010. The experiment was conducted with $23^{\circ}C$ to $25^{\circ}C$ room temperature and 50% to 66% of moisture from 2 to 6 p.m. After heat was applied on the shoulder of the subjects wearing shorts and gowns for 30 minutes, their superficial and core temperatures were measured. The same method was used on the thigh after two hours. Results: Both superficial and core temperatures on the shoulder and thigh increased significantly after heat therapy. There was no significant difference between the temperatures before and after intervention according to applying methods and regions. Conclusion: This study provides a theoretical basis that a dry heat is a convenient nursing intervention for hypothermic patients.

Effects of High-Frequency Treatment using Radiofrequency on Autonomic Nervous System and Pain in Women with Dysmenorrhea

  • Sungeon Park;Seungwon Lee;Inok Kim
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.493-501
    • /
    • 2022
  • Objective: The purpose of this study is to present basic data for appropriate therapeutic intervention by confirming changes in the autonomic nervous system and pain by applying high-frequency deep diathermy to the lower abdomen in patients with primary dysmenorrhea. Design: A randomized controlled clinical trial. Methods: Thirty-eight women aged 18-50 years who complained of regular menstrual cycles (24-32 days) and primary dysmenorrhea symptoms were randomly assigned to a high-frequency therapy group (5, 7, or 9 mins) and a superficial heat therapy group (20 min). High frequency treatment group: The subject was in a supine position, and radio frequency was applied to the lower abdomen below the umbilicus. The radio frequency therapy device used in this study uses a 300 kHz capacitive electrode and a 500 kHz resistive electric transfer to deliver deep heat. Superficial heat treatment Group: Subjects applied a hot pack to the lower abdomen for 20 minutes while lying on their back. Evaluations were made of Heart rate variability and Visual Analogue Scale. Results: In subjects with menstrual pain, there was a significant difference in pain between the high-frequency therapy group and the superficial heat therapy group (p=0.026). However, there was no significant difference between the autonomic nervous system and the stress resistance (p>0.05). Conclusions: As a result of this study, high-frequencytreatment using radiofrequency was effective in relieving pain because it can penetrate deeper tissues than conventional hot packs using superficial heat. In particular, it was found that the optimum effect was obtained when high frequency was applied forfive-seven minutes.

A literature study on change of surperficial temperature (체표 온도 변화에 대한 문헌 고찰)

  • Kim, Sang-Rok;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.4 no.1
    • /
    • pp.54-60
    • /
    • 2005
  • Object: A study on the changes of superficial temperature as the ambient temperature varies. Method: After performing research on the physiologic mechanism of heat loss from skin, heat transfer to skin and heat productions of body, the conclusions would be drawn from experiments on temperature changes in every parts of the body as ambient temperature varies . Result and conclusion: Superficial temperature is in equilibrium with ambient temperature after a certain period. Part of the body with big change in superficial temperature tends to have slower temperature change and longer time for adaptation than the part with small change in superficial temperature. The temperature difference between left and right side of the body needs no attention. If adequate adaptation time, a short-period living supervision prior to measurements and appropriate indoor environment management are provided, meaningful conclusion would be attained for infrared thermal diagnosis.

  • PDF

Two-Phase Flow Characteristics in an Adiabatic Horizontal Tube (단열 수평관내 이상류의 유동특성)

  • Choi, B.H.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.36-40
    • /
    • 2004
  • Two-phase loop systems using the latent heat capacity of their working fluids can meet the increasing power requirements and are well suited to thermal management systems of future large applications, due to its abilities to handle large heat loads and to provide them at uniform temperatures regardless of the changes in the heat loads. Therefore some experiments on the effect of the gas and liquid superficial velocities, $j_G,\;j_L$ on flow pattern transition, void fraction and frictional pressure loss were performed on a co-current air-water flow in an adiabatic horizontal tube. The flow patterns were depended on the superficial velocity of each phase. It snowed that the increasing $j_L$, resulted in a significant increase in the frictional pressure loss for all flow patterns, at a constant $j_G$. The experimental results were also evaluated with some of existing models and correlations.

  • PDF

Effects of Sequential Application of Superficial Cold and Heat on Pain, Patient Satisfaction with Pain Control, Comfort Level and Subjective Response after Spine Surgery (순차적 냉·온 요법이 척추 수술 후 통증과 통증 조절 만족도, 안위, 주관적 반응에 미치는 효과)

  • Kim, Jeoung Hee;Lhim, Seung Chul;Roh, Sung Woo;Lee, Sun Jin;Ko, Young Mi;Kim, Yeo Ok;Shin, Yong Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.23 no.2
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: The aims of the current study were to evaluate the effects of superficial cold and heat after spine surgery on pain, satisfaction with pain control and comfort level, and to identify subjective responses and adverse effects. Methods: A prospective, single-blind, randomized controlled trial was utilized. The intervention group (n=36) received superficial cooling until the wound drain was removed and thereafter followed by superficial heating until discharge, while the control group (n=34) received only superficial cooling until wound drain was removed. Data were collected from August 4 to November 11 2014. Results: There was significant difference in pain according to time within groups (F=71.87, p<.001). However, we found no difference in pain between groups. The intervention group reported higher patient satisfaction with pain control (4 vs 3, z=-2.83, p=.005) and higher comfort level (5 vs 4, z=-4.12, p<.001) than the control group. Conclusion: Results indicate that sequential application of superficial cold and heat is a useful method in clinical practice for management of pain after spine surgery.

Heat Transfer in Bubble Columns with High Viscous and Low Surface Tension Media (고점성 낮은표면장력 매체 기포탑에서 열전달)

  • Kim, Wan Tae;Lim, Dae Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.516-521
    • /
    • 2014
  • Axial and overall heat transfer coefficients were investigated in a bubble column with relatively high viscous and low surface tension media. Effects of superficial gas velocity (0.02~0.1 m/s), liquid viscosity ($0.1{\sim}0.3Pa{\cdot}s$) and surface tension ($66.1{\sim}72.9{\times}10^{-3}N/m$) on the local and overall heat transfer coefficients were examined. The heat transfer field was composed of the immersed heater and the bubble column; a vertical heater was installed at the center of the column coaxially. The heat transfer coefficient was determined by measuring the temperature differences continuously between the heater surface and the column which was bubbling in a given operating condition, with the knowledge of heat supply to the heater. The local heat transfer coefficient increased with increasing superficial gas velocity but decreased with increasing axial distance from the gas distributor and liquid surface tension. The overall heat transfer coefficient increased with increasing superficial gas velocity but decreased with increasing liquid viscosity or surface tension. The overall heat transfer coefficient was well correlated in terms of operating variables such as superficial gas velocity, liquid surface tension and liquid viscosity with a correlation coefficient of 0.91, and in terms of dimensionless groups such as Nusselt, Reynolds, Prandtl and Weber numbers with a correlation of 0.92; $$h=2502U^{0.236}_{G}{\mu}^{-0.250}_{L}{\sigma}^{-0.028}_L$$ $$Nu=325Re^{0.180}Pr^{-0.067}We^{0.028}$$.

Circularly Rotated Array for Dual Polarized Applicator in Superficial Hyperthermia System

  • Kim, Ki Joon;Choi, Woo Cheol;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.1
    • /
    • pp.20-25
    • /
    • 2015
  • A circularly rotated array for a dual polarized applicator in a superficial hyperthermia system is proposed. The applicator has a wider effective treatment area due to the $180^{\circ}$ phase shift. The dual polarized circularly rotated array (DPCRA) suppresses overheating at the center of the array and helps evenly distribute the heat. This array provides a more effective treatment area than a lattice array when a $2{\times}2$ dual polarized array is fitted to the treatment area. The treatment area is 71.5% of the aperture, whereas the effective treatment areas of the $2{\times}2$ dual polarized lattice array (DPLA) and the single polarized array (SPA) are 57.2% and 38.6% of the same aperture, respectively. The measurement matches the simulation results without blood circulation effects. In a $2{\times}2$ array applicator, the proposed DPCRA has more heat uniformity than the DLA and the SPA.

Two phase convective heat transfer augmentation in swirl flow with non-boiling (비비등 선회유동에서의 2상 대류열전달 증가)

  • ;;Kim, J. G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2586-2594
    • /
    • 1995
  • Two phase flow phenomena are observed in many industrial facilities and make much importance of optimum design for nuclear power plant and various heat exchangers. This experimental study has been investigated the classification of the flow pattern, the local void distribution and convective heat transfer in swirl and non-swirl two phase flow under the isothermal and nonisothermal conditions. The convective heat transfer coefficients in the single phase water flow were measured and compared with the calculated results from the Sieder-Tate correlation. These coefficients were used for comparisons with the two-phase heat transfer coefficients in the flow orientations. The experimental results indicate, that the void probe signal and probability density function of void distribution can used into classify the flow patterns, no significant difference in voidage distribution was observed between isothermal and non-isothermal condition in non-swirl flow, the values of two phase heat transfer coefficients increase when superficial air velocities increase, and the enhancement of the values is observed to be most pronounced at the highest superficial water velocity in non-swirl flow. Also two phase heat transfer coefficients in swirl flow are increased when the twist ratios are decreased.