• 제목/요약/키워드: Superconducting Motor

검색결과 103건 처리시간 0.037초

수냉식 1MW 고온초전도 동기모터의 설계 (Design of Water-cooled 1MW HTS Synchronous Motor)

  • 백승규;손명환;이언용;권영길;문태선;박희주;김영춘
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.21-28
    • /
    • 2005
  • Superconducting synchronous motors and generators have the field coil composed of superconductor with almost zero resistance at superconducting state. Therefore, copper loss at the conventional field coil is eliminated and the superconducting machine gets higher efficiency. The armature coil of the superconducting machine is composed of copper wire and supported by non-magnetic material such as FRP (Fiber Reinforced Plastic) This paper contains the design Procedure of a 1MW superconducting synchronous motor using high-temperature superconductor only for the field coil. Especially, the armature coil is designed by water-cooling in order to dissipate Joule heat easily. Moreover, 3-dimensional electromagnetic design is conducted to get a proper design result and reduce design errors from 2-dimensional approach.

Analysis of mechanical characteristics of superconducting field coil for 17 MW class high temperature superconducting synchronous motor

  • Kim, J.H.;Park, S.I.;Im, S.H.;Kim, H.M.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.13-19
    • /
    • 2013
  • Superconducting field coils using a high-temperature superconducting (HTS) wires with high current density generate high magnetic field of 2 to 5 [T] and electromagnetic force (Lorentz force) acting on the superconducting field coils also become a very strong from the point of view of a mechanical characteristics. Because mechanical stress caused by these powerful electromagnetic force is one of the factors which worsens the critical current performance and structural characteristics of HTS wire, the mechanical stress analysis should be performed when designing the superconducting field coils. In this paper, as part of structural design of superconducting field coils for 17 MW class superconducting ship propulsion motor, mechanical stress acting on the superconducting field coils was analyzed and structural safety was also determined by the coupling analysis system that is consists of commercial electromagnetic field analysis program and structural analysis program.

고온초전도동기모터의 교류손실에 따른 ?치 해석에 관한 연구 (A Study on the Quench characteristics Analysis considering Ac-Losses of High-Tc Superconducting Synchronous Motor)

  • 윤용수;송명곤;문창욱;홍계원;이상진;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.93-96
    • /
    • 1999
  • This paper deals with the quench characteristic analysis in high-Tc superconducting synchronous motor of five to six hundred watts capacity. First, the magnetic field distribution and ac losses of high-Tc superconducting motor with the additive flux damper circuit was derived and computer simulation was performed with the equivalent model using FEM. The simulation results show that the quench state lasts for about 0.3 seconds.

  • PDF

1MW 고온초전도 동기모터의 개념설계 고찰 (Conceptual Design Considerations of 1MW Class HTS Synchronous Motor)

  • 백승규;손명환;이언용;권영길;문태선;박희주;김영춘
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권3호
    • /
    • pp.38-43
    • /
    • 2004
  • 1MW class superconducting synchronous motor is designed considering several conditions such as superconducting wire length, machine efficiency and size. As the machine is larger and larger, the superconducting machine shows the advantages more and more over the conventional machines. Although the advantages at 1MW rating are not so great, the design approach to get an appropriate result would be very helpful for larger superconducting synchronous machine design. Major design concerns are focused on reducing expensive Bi-2223 HTS(High Temperature Superconducting) wire which is used for superconducting field coil carrying the rating current around 30K(-243$^{\circ}C$) while the machine efficiency is higher than conventional motors or generators with the same rating. Furthermore, some iron cored structure is considered to reduce the HTS wire requirement without bad effect on machine performances such as sinusoidal armature voltage waveform, synchronous reactance and so on.

유한요소법을 이용한 고온초전도 동기모터 특성해석 (Performance evaluation of Superconducting synchronous motor via Finite element method)

  • 백승규;김석환;손명환;조영식;서무교;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.720-722
    • /
    • 2002
  • Superconducting synchronous motor using HTS(high-temperature superconducting) field windings has a lot of advantages over LTS(Jow-temperature superconducting) synchronous machine. A recently developed 5000[hp] HTS motor represents 1/2 reduction in weight and volume compared to an induction type conventional machine. Furthermore. 40% machine loss is reduced compared to the industry average. Based on a conceptual design, a 100[hp] HTS synchronous motor is modeled by F.E.M(Finite Element Method) and the performance is predicted in this paper

  • PDF

레일방식 초고속열차 추진용 축소 초전도 LSM 설계 연구 (Design of a Small-scaled Superconducting LSM for the Very High Speed Railway Vehicle)

  • 박찬배;김재희;이병송
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1602-1607
    • /
    • 2014
  • This paper deals with the design and property analysis of 7kW-class small-scaled superconducting Linear Synchronous Motor (LSM) and testing equipment for a number of performance pre-tests prior to the development of coreless-type superconducting LSM suitable for 600km/h very high speed train. First, the basic design and property analysis are conducted before developing a small-scaled superconducting LSM model with 2-pole superconducting electromagnets, and additionally the cost-down design of the superconducting electromagnets is conducted to use less high-Tc superconducting wire. Finally, the superconducting magnet coil span is selected at 120mm, and input ground armature current of 670Aturns is required to produce 44.7N of thrust based on research findings.

고온초전도동기모터의 부하변동에 따른 계자권선의 교류손실 해석에 관한 연구 (A Study on the Analysis for Ac-losses of the Field Winding considering Load Changes of High-Tc Superconducting Synchronous Motor)

  • 윤용수;송명곤;장원갑;장인배;홍계원;이상진;고태국
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권4호
    • /
    • pp.167-173
    • /
    • 1999
  • The use of high-Tc superconducting synchronous motor in power machinery has many advantages such as reduced power dissipation, size and weight. This paper presents the ac loss simulation in the rotor having an high-Tc superconducting field winding using Ag sheathed Bi-2223. The analysis was conducted with an equivalent model of the high-Tc superconducting motor with flux damper under transition condition during which the load varies from 0 watt to 250watts and from 250watts to 500watts. The simulation results show that the transient state lasts for about 3 seconds, and the ac losses decreased exponentially from the initial value above 20mW.

  • PDF

전초전도 호모폴라 모터의 3차원 자계해석 및 회로상수 추출 (3D Field Analysis And Circuit Parameter Calculation of Superconducting Homopolar Synchronous Motor)

  • 조영한;성탄일;김영선;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.700_701
    • /
    • 2009
  • In comparison with conventional motors, Superconducting Homopolar Synchronous Motors (SHSMs) have advantages that it generates high magnetic field by superconducting winding. Therefore, superconducting coil used in SHSM can reduce the motor size and enhance the motor efficiency for high torque applications under the space constraints for propulsion system. During the design process of SHSM, it is required to evaluate the performance of initial design model, that is accurately analyzed using 3D magnetic field modeling large air-gap and flux distribution of axial direction is properly taken into account. In this paper, we analyze magnetic field of a homopolar motor with a 4-pole homopolar rotor and a stator of 3 phase windings. The field analysis is done using 3D finite element analysis which can reflect the end effect and overhang winding. And we extract mutual inductances between a rotor wind and the 3 stator windings. The extracted inductances are used for evaluation of overall motor performances that are calculated with generalized circuit theory of electrical machines.

  • PDF

Basic Study of IPMSM with High-Temperature Superconducting Wire Rod

  • Okada, Kazuya;Morimoto, Shigeo;Sanada, Masayuki;Inoue, Yukinori
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.148-153
    • /
    • 2013
  • It is important to improve the efficiencies of motors to overcome problems such as decreasing energy reserves and environmental pollution. Superconductors are promising for developing high-efficiency motors. However, superconducting wires must be kept in critical conditions and the AC loss needs to be minimized. In this paper, a design of a superconducting interior permanent magnet synchronous motor (IPMSM) is proposed that reduces the AC loss. The characteristics of superconducting and normal-conducting IPMSMs are compared. The proposed superconducting IPMSM has a low AC loss and a very high efficiency at low speeds.

5 MW 고온초전도 모터 설계 (Conceptual Design of a 5 MW HTS Motor)

  • 백승규;권영길;김호민;이재득;김영춘;박희주;권운식;박관수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권3호
    • /
    • pp.36-42
    • /
    • 2008
  • The superconducting motor shows several advantages such as smaller size and higher efficiency against conventional motor especially utilized in ship propulsion application. However, this size reduction merit appears in large capacity more than several MW. We are going to develop a 5MW class synchronous motor with rotating High-Temperature Superconducting (HTS) coil. that is aimed to be utilized for ship propulsion so it has very low-speed, The ship propulsion motor must generate very high electromagnetic torque instead of low-speed. Therefore. the rotor (field) coils need very large magnetic flux that results in large amount of expensive HTS conductor for the field coil. In this paper a 5MW HTS motor for ship propulsion is considered to be designed with construction cost reduced via HTS field coil cost reduction because HTS conductor cost is critical factor in the construction cost of HTS motor. In order to reduce the HTS conductor amount. iron-cored rotor types are considered. so several cases with iron-core are compared one another and with an air-core case.