• Title/Summary/Keyword: Summer peak time

Search Result 120, Processing Time 0.022 seconds

A Study on the Convective Heat Transfer in a Regenerative Ice Energy System by a Bundle of the Heat-pipes. (히이트파이프 다발을 이용한 냉축열시스템에서의 대류열전달에 관한 연구)

  • 권형정;김경석;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.57-66
    • /
    • 1990
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air conditioning systems are being operated during daytime in summer season, which inevitably entails the construction of an additional electric power plant. This study is aimed to carry out a basic experiment for the development of a cooling air conditioning system using the ice energy by the surplus electric power during the night-time. The experimental apparatus consists of four major parts; (1) the heating section consisting of the air duct and I.D. fan, (2) the cold section with the ice chamber, (3) the bundle of heat pipes made in a form of the staggered arrangement with ${C_y}/{d_o}$=2.0 and ${C_x}/{d_o}$=1.73, (4) the refrigerator system to cool down the ice chamber. This study involves an intensive experiment concerning the convective heat transfer of the air flow surrounding the bundle of heat pipes. This major experimental parameters are the amount of working fluid, the velocity of air and the working temperature. The major findings of the present study are as follows; (1) The optimum amount of the working fluid necessary for the horizontal heat pipes is much more than that for the vertical type. (2) The convective heat transfer coefficients of the air are coincided with the empirical equations of Grimson and ${\breve{Z}ukauskas}$. (3) The equation of the mean heat transfer coefficient obtained in the present study is ${N_um}=0.32 {Re_max^{0.63}}$.

  • PDF

A Decline of Observed Daily Peak Wind Gusts with Distinct Seasonality in Australia, 1941-2016

  • Cesar Azorin-Molina;Tim R. McVicar;Jose A. Guijarro;Blair Trewin;Andrew J. Frost;Gangfeng Zhang;Lorenzo Minola;Seok-Woo Son;Kaiqiang Deng;Deliang Chen
    • Journal of Climate Change Research
    • /
    • v.34 no.8
    • /
    • pp.3103-3127
    • /
    • 2021
  • Wind gusts represent one of the main natural hazards due to their increasing socioeconomic and environmental impacts on, for example, human safety, maritime-terrestrial-aviation activities, engineering and insurance applications, and energy production. However, the existing scientific studies focused on observed wind gusts are relatively few compared to those on mean wind speed. In Australia, previous studies found a slowdown of near-surface mean wind speed, termed "stilling," but a lack of knowledge on the multidecadal variability and trends in the magnitude (wind speed maxima) and frequency (exceeding the 90th percentile) of wind gusts exists. A new homogenized daily peak wind gusts (DPWG) dataset containing 548 time series across Australia for 1941-2016 is analyzed to determine long-term trends in wind gusts. Here we show that both the magnitude and frequency of DPWG declined across much of the continent, with a distinct seasonality: negative trends in summer-pring-autumn and weak negative or nontrending (even positive) trends in winter. We demonstrate that ocean-atmosphere oscillations such as the Indian Ocean dipole and the southern annular mode partly modulate decadal-scale variations of DPWG. The long-term declining trend of DPWG is consistent with the "stilling" phenomenon, suggesting that global warming may have reduced Australian wind gusts.

Color evolution of HBC 722 in the post-outburst phase

  • Baek, Giseon;Pak, Soojong;Green, Joel D.;Lee, Jeong-Eun;Bae, Kyoung Min;Jeon, Yiseul;Choi, Changsu;Im, Myungshin;Meschiari, Stefano
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.70.2-70.2
    • /
    • 2013
  • We present collections of optical photometry for a pre-main sequence star HBC 722. It showed large amplitude optical outburst (${\Delta}V=4.7$ mag) in 2010 and classified as a FU Orionis type object. We have been observing HBC 722 from 2011 April to 2013 May, using Camera for QUasars in EArly uNiverse (CQUEAN) attached to the 2.1 m Otto Struve telescope at the McDonald Observatory. Time-series monitoring data (minute-scale interval) were obtained in SDSS r, i and z bands to see short-scale behaviors as well as trace the long-term brightness changes after the eruption in 2010. Interestingly, it started to brighten from 2011 early summer and became brighter than the first outburst peak in our 2013 May observation. We expect that the recovering phase would result from re-increase of disk accretion rate, might attribute to distinctive short-scale color features. In this presentation, we report long- and short-timescale optical behaviors of HBC 722 in the post-outburst phase.

  • PDF

Physical and Operational Supply Margin Evaluation of KOREA Power System (우리나라 전력계통의 물리적 및 운영 측면에서의 공급 여유력 평가)

  • Kwon, Jung-Ji;Jeong, Sang-Heon;Shi, Bo;Tran, TrungTinh;Choi, Jae-Seok;Cha, Jun-Min;Yoon, Yong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.18-27
    • /
    • 2007
  • Successful operation of power system under regulated as well as deregulated electricity markets is very important. This paper presents marginal power flow evaluation of KEPCO system in view point of physical and operation mode by using Physical and Operational Margins (POM Ver.2.2), which is developed by V&R Energy System Research. This paper introduces feature and operation mode of POM Ver.2.2 and then evaluates scenarios of 6 lines contingencies of 765kv of KEPCO system at peak load time on summer in 2006 you. The case study for actual 2006 year KEPCO system shows that this POM program is applicable sufficiently to KEPCO system. Futhermore, it demonstrates that it is helpful for operator's operating the system successfully by evaluating physical and operational margins quickly for various contingencies occurred in KEPCO system. Eventually, it will assist operators to operate more reliably the KEPCO system in future.

Empirical Results and Operational Cost Analysis of Geothermal Heat Pump System using Thermal Energy Storage in Cooling Season (축열식 지열원 히트펌프 시스템의 냉방기간 실증운전 결과 및 운영비용 분석)

  • Kim, Deukwon;Lee, Dongwon;Heo, Jaehyeok;Kim, Minhwi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.167-174
    • /
    • 2018
  • The geothermal heat pump systems were installed for heating and cooling of public buildings in Jincheon Eco-friendly Energy town. The heat pump system was operated at night to save on operational costs, and the cold heat was stored in thermal energy storage (TES). In this study, the performance of geothermal heat pump systems with the TES during the summer season was analyzed, and the operational costs with and without the TES were compared. The electric chiller model was used to simulate a heat pump applied without the TES system. Electric rates of each system were measured to calculate operational costs. When the TES is used in the air conditioning system, the electric load (30.4 MWh) calculated in the daytime can move to off-peak load time, and the operational cost is reduced by 36~54%.

Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung (창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Han, Wook;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF

The Watershed Imperviousness Impact for the characteristic of stormwater runoff (유역의 불투수성에 따른 강우유출특성 비교)

  • Ham, Kwang-Jun;Kim, Joon-Hyun;Huh, Beom-Nyung;Choi, Ji-Yong;Kim, Yeong-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.157-163
    • /
    • 2006
  • The purpose of this study is to understand imperviousness impact for the characteristics of stormwater runoff and water temperature. The land-use map was used to estimate the watershed imperviousness(percent of impermeable area) and the RMS(Remote Monitoring System) was used to evaluate the stormwater runoff of watershed. This study was investigated for two streams(Jiam and Gongji) in Chunchon City. The detailed results of these studies are as follows; The imperviousness(%) of two watersheds(Jiam and Gongji) estimated by spatial analysis which is main function of GIS were 0.24% and 24.16%. So, Gongji watershed as urban area was about 100 times than jiam watershed as forest area. In case of rainfall of low intensity, stormwater runoff flowrate in higher imperviousness area(Gongji) was more than it in forest area(jiam). Also, The time to peak flowrate(Tp) was short in Gongji stream and the water temperature difference between Gongji and Jiam stream was about $4.4^{\circ}C$ in summer.

Temporal and spatial fluctuation characteristics of sea surface temperature in Yeosu Bay, Korea (여수해만 수온의 시공간적 변동특성)

  • CHOO, Hyo-Sang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.4
    • /
    • pp.322-339
    • /
    • 2020
  • Temporal and spatial fluctuations of surface water temperature in Yeosu Bay for the period from 2010 to 2011 were studied using the data from temperature monitoring buoys deployed at 32 stations in the south coast of Korea. Temperatures in the northern part of the bay are higher in summer and lower in winter than in the southern part of the bay. The lowest and highest temperature of the annual mean are found at the eastern coast of POSCO and at the west of Dae Island, respectively. Cold water masses appear at estuarine area when the discharge of Sumjin river is affluent. Amplitude of temperature fluctuation whose period is less than semi-diurnal is largest at Hadong coast and around Dae Island. Spectral analysis of surface water temperature shows a significant peak at a periodic fluctuation of 0.5 to 24 days and about 15-day period of predominant fluctuation is most frequent in Yeosu Bay. From the cross-correlation analysis of temperature fluctuations, Yeosu Bay can be classified into six areas; the south area affected by South Sea of Korea, the mixed area in the center of the bay, the estuarine area affected by river discharge at the north of the bay, the hot waste water area near Hadong coast, the area around Dae Island and the area near Noryang Channel affected by the water in Jinju Bay, respectively.

Seasonal Occurrence and Monitoring of Gypsy Moth, Lymantria dispar L. (Lepidoptera: Lymantriidae) by Sex Pheromone Trap in Mt. Namsan, Seoul. (남산 매미나방의 계절적 발생소장과 성페로몬에 의한 예찰)

  • 이해풍;이현민
    • The Korean Journal of Ecology
    • /
    • v.22 no.5
    • /
    • pp.299-303
    • /
    • 1999
  • Studies were conducted in Mt. Namsan, Seoul, during the summer of 1997 and 1998 using racemic disparlure to determine seasonal occurrence and circadian activity in male gypsy moth, and size of egg mass and wing length of male moth. Male gypsy moths occurred from middle part of July until middle part of August and peaked in late part of July. Circadian activity of male moths initiated from 12: 00h and continued until 21: 00h, and the peak time was between 14: 00h and 17: 00h. Mean number of moths captured per trap in 1997 was larger than that in 1998, however, eggs per mass, egg size and wing length were not significantly different between the two years, 1997 and 1998.

  • PDF

Multi-level UnderVoltage Load Shedding Scheme Considering Rate of Change of Voltage for Voltage Stability (전압 변동률을 고려한 수도권 전압 안정화 다단계 부하차단 적용 방안)

  • Lee, Yun-Hwan;Kim, Tae-Gyun;Kim, Ji-Hun;Lee, Byong-Jun;Kang, Bu-Il;Cho, Jong-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2335-2341
    • /
    • 2009
  • High technique growth of modem times and high industrial facility in consequence of buildings demand for electric power of an extensive scale with stability supply and maintenance of high quality. But, power system always have risk of network contingency. When power system break out disturbance, it circumstantially happen like uncontrolled loss of load developing from of cascading. Severely which would be raised wide area blackout, plan to prevent, which make stability through a little of load shedding and multi-level UnderVoltageLoadShdding should work. This paper presents target, sensitivity of bus voltage have choose appropriating load shedding location and load shedding decision making logic with considering rate of change of voltage have studied multi-level under voltage load shedding scheme. Calculation of rate of change of voltage applied method of least square. As a result, we are studied an dynamic analysis of 2008 summer peak data. We have been known that network analysis is a little development and developing UnderVoltageLoadShedding scheme.