• Title/Summary/Keyword: Summer peak time

Search Result 120, Processing Time 0.023 seconds

Characteristics of Concentration Distribution of Coastal Urban Air Pollutants (연안 도시 대기오염 물질의 농도분포 특성)

  • 박종길;석경하;김지형;차주완
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1243-1252
    • /
    • 2002
  • This paper aims to find the characteristics of concentration distribution of coastal urban air pollutants. For this purpose, It was used the daily meteorological data and the hourly concentration data for $O_3$and NO$_2$ in Busan metropolitan city from 1994 to 1996. It was investigated the annual and monthly distribution of ozone and nitrogen dioxide concentration at each site in Busan, and also investigated the characteristics of concentration change of air pollutants with time under the sea breeze. As a results, the concentration of nitrogen dioxide and ozone tend to be increased every year and nitrogen dioxide concentration is higher than ozone concentration at all sites in Busan. The concentration of ozone is high in summer season and low in winter season, but the concentration of nitrogen dioxide have a reversed trend. The monthly peak concentration of ozone occurred in April and September, while the monthly minimum concentration of nitrogen dioxide occurred in August. Their trend were identified by sites near the coastline than sites stands apart from the coastline. The sea breeze occurred annual mean 81 day in Busan from 1994 to 1996. The main wind direction of sea breeze was classified into southwesterly and southeasterly. In case of southwesterly, It was pronounced the south wind and southwest wind. In case of southeasterly, the occurrence frequency of east wind was high. Especially, the concentrations of urban air pollutants, such as ozone and nitrogen dioxide, were high on time which the sea breeze flow, and the areas that ozone concentration was high moved from outside part to central part of city with time. In costal urban such as Busan, the wind direction of sea breeze is influenced the change of ozone and nitrogen dioxide concentration on time which the sea breeze flow at each site and also influenced the change of air pollutants concentration of sites on the pathway of sea breeze.

Public Evacuation Time Estimates within EPZ of Ulchin Site (울진원전 방사선비상계획구역 내의 주민 소개시간 예측)

  • Chung Yang-Geun;Lee Gab-Bock;Bang Sun-Young;Kim Sung-Min;Lee Eun-Mi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.359-372
    • /
    • 2005
  • The strong protection method of radiation emergency preparedness is the evacuation when a great deal of radionuclide material is released to environment. Required factors for evacuation time estimate of Ulchin nuclear power plant site were investigated. The traffic capacity and the traffic volume by season were investigated for the traffic analysis and simulation within EPZ of Ulchin site. As a result, the background traffic volume by season were established. The NETSIM code was applied to simulate for 12 scenarios in the event of normal traffic/summer peak traffic/winter peak traffic, daytime/night, and normal weather/adverse weather conditions. The results showed that the evacuation time required for total vehicles to move out from EPZ took generally $210\~315$ minutes. The evacuation time took longer about 45 minutes at night than in the daytime, and 45 minutes in adverse weather than normal condition.

  • PDF

Characteristics of PM10 concentration at seashore and inland according to land-use in Busan (부산지역 지역용도별 해안과 내륙의 PM10 농도 특성)

  • Jeon, Byung-Il
    • Journal of Wetlands Research
    • /
    • v.11 no.2
    • /
    • pp.47-54
    • /
    • 2009
  • This study was conducted to consider the characteristics of PM10(particulate matter with aerodynamic diameters less than 10 ${\mu}m$) concentration according to land-use in Busan coastal area. Fine particle is affected by emissions, geographical conditions and meteorological factors. In case industrial area, Gamjeondong(inland) PM10 concentration was higher than Noksandong(seashore) at all season except for Summer. Primary peak at Gamjeondong cleared than Noksandong in Fall and Winter. In case green area, Daejeodong(inland) PM10 concentration was higher than Dongsamdong(seashore) at all seasons. In case commercial area, primary peak occurrence time at Jeonpodong lagged one hour according to season and diurnal change of PM10 concentration at Gwangbokdong was higher than Jeonpodong in Spring. In case residential area, high PM10 concentration(80~90 ${\mu}g/m^3$) lasted for six hours during the daytime in Spring at Deogcheondong and Yongsuri(inland).

  • PDF

The Radiative Characteristics of EUV-B over the Korean Peninsula and Exposure Time for Synthesizing Adequate Vitamin D (한반도 EUV-B 복사의 특성분석 및 적정 비타민D 합성을 위한 노출시간 산출)

  • Kwak, Min Kyoung;Kim, Jae Hwan
    • Atmosphere
    • /
    • v.21 no.1
    • /
    • pp.123-130
    • /
    • 2011
  • In this study, we have analyzed the radiative characteristics of erythemal ultraviolet-B (EUV-B from 1999 to 2005) over the Korean Peninsula. EUV-B measured at Gangneung, Anmyondo, Mokpo, and Gosan represents the measurements from clean areas and that at Seoul represents from a polluted area. The magnitudes of EUV-B increase in proportion to the latitudinal decrease. Monthly mean variation of EUV-B at noon shows the maximum value of $158.5mWm^{-2}$ in August and the minimum value of $36.4mWm^{-2}$ in December in the clean areas. Seasonal mean diurnal variation of EUV-B shows a peak around noon (12:00 ~ 13:00 hr) and its intensity varies along with a season in order of summer > spring > fall > winter. The maximum value of $56.4mWm^{-2}$ in summer is three times higher than that in winter ($14.3mWm^{-2}$). The value of EUV-B in the polluted area is lower than that in the clean areas, resulting from the effects of the blocking, reflection, and scattering of EUV-B due to high concentrations of PM10. UV-B is an essential element to synthesize vitamin D in human body. 200 IU(International Unite) of vitamin D can be formed by an exposure of 6-10% of body surface area to 0.5 MED(Minimal Erythemal Dose). In order to form vitamin D, the calculated exposure times to EUV-B are 15 min. in spring, 12 min. in summer, 18 min. in fall, and 37 min. in winter for the clean areas and 16, 16, 24, and 37 min. for the polluted area.

Variation of the Hemispheric Asymmetry of the Equatorial Ionization Anomaly with Solar Cycle

  • Kwak, Young-Sil;Kil, Hyosub;Lee, Woo Kyoung;Yang, Tae-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.3
    • /
    • pp.159-168
    • /
    • 2019
  • In solstices during the solar minimum, the hemispheric difference of the equatorial ionization anomaly (EIA) intensity (hereafter hemispheric asymmetry) is understood as being opposite in the morning and afternoon. This phenomenon is explained by the temporal variation of the combined effects of the fountain process and interhemispheric wind. However, the mechanism applied to the observations during the solar minimum has not yet been validated with observations made during other periods of the solar cycle. We investigate the variability of the hemispheric asymmetry with local time (LT), altitude, season, and solar cycle using the electron density taken by the CHAllenging Minisatellite Payload satellite and the global total electron content (TEC) maps acquired during 2001-2008. The electron density profiles provided by the Constellation Observing System for Meteorology, Ionosphere, and Climate satellites during 2007-2008 are also used to investigate the variation of the hemispheric asymmetry with altitude during the solar minimum. During the solar minimum, the location of a stronger EIA moves from the winter hemisphere to the summer hemisphere around 1200-1400 LT. The reversal of the hemispheric asymmetry is more clearly visible in the F-peak density than in TEC or in topside plasma density. During the solar maximum, the EIA in the winter hemisphere is stronger than that in the summer hemisphere in both the morning and afternoon. When the location of a stronger EIA in the afternoon is viewed as a function of the year, the transition from the winter hemisphere to the summer hemisphere occurs near 2004 (yearly average F10.7 index = 106). We discuss the mechanisms that cause the variation of the hemispheric asymmetry with LT and solar cycle.

Changes in the Occurrence Pattern of the Striped Rice Borer, Chilo suppressalis Walker, in Korea (이화명나방의 발생양상 변동에 관한 연구)

  • 이승찬;박해준
    • Korean journal of applied entomology
    • /
    • v.30 no.4
    • /
    • pp.249-257
    • /
    • 1991
  • Chronological changes in the occurrence pattern of the striped rice borer(SRB), Chilo suppressalis Walker, were investigated by analyzing the data collected by 33 light traps of the countrywide monitoring units during the period of 1968-1989. And also relation of incidences between larval and adult populations, emergence time and percent emergence of overwintered larvae were observed in relation to the time of different rice transplantations. Spring moths of SRB in 1985-'89 generally emerged earlier than in 1968-'72 : 30 days earlier at Kwangju, 20 -25 days earlier at Sangju and Naju, 10-15 days earlier at Uljin, Jinju, Goyang, Milyang, Kimhae, etc., 5 days earlier at Suweon, Jinchun, Daejeon, Namweon, Haenam, etc. There was no change in the time of spring moth emergance at Weonseong, Chungju, Seosan, Yongju, and Nonsan. Summer moths of SRB in 1985- '89 also emerged earlier than 1968- '72: 20 days earlier at Uljin, 15 days earlier at Chungju, Yeongdug, and Habchun, 5-10 days earlier at the other areas except Yeongju. There was an overall countrywide decrease in the population of the 1st generation of SRB during the last two decades. The population of the 2nd generation also decreased in 19 areas during the same period, but increased in 14 areas including over 3-fold increases in Kwangju, Naju and Daegu, and double increase in Jinju, Milyang and Gongju. The higher larval population density of 1st genration was taken place in the earlier transplanted fields, whereas the population of 2nd generation were higher at mid-season transplanted (May 30), followed by May 15, June 15, and April 30. The peak of larval population appeared generally 15 days after moth peak in 1st generation, and 10 days after moth-peak in 2nd generation. The earlier transplanted fields were the higher percent damage due to 1st off-springs of spring moths, whereas the fields transplanted in mid-season were higher damage due to 2nd off-springs of summer moths. Average body weights of SRB larvae before overwintering were 65.6 mg, 61.2 mg, and 55.5 mg in early, mid-season, and late transplantations, respectively. In field cage experiments, emergence rate of the overwintered larvae ranged from 28.3-39.8%. In other words, body weights of overwintering larvae were heavier in fields by earlier transplantation, and heavier larvae showed higher percentage of adult emergence. The period from overwintered larvae to adult emergence was longer in the fields of the later transplantations; namely, 44, 49, and 51 days for early, mid-season, and late transplantations, respectively.

  • PDF

Temperature Effects on the Industrial Electricity Usage (산업별 전력수요의 기온효과 분석)

  • Kim, In-Moo;Lee, Yong-Ju;Lee, Sungro;Kim, Daeyong
    • Environmental and Resource Economics Review
    • /
    • v.25 no.2
    • /
    • pp.141-178
    • /
    • 2016
  • This paper, using AMR (Automatic Meter Reading) electricity data accurately measured in real time, analyses the characteristics and patterns of temperature effect on the industrial electricity usage. For this goal, the paper constructs and estimates a model which captures the properties of AMR time series including long-term trends, mid-term temperature effects, and short-term special day effects. Based on the estimated temperature response function and the temperature effect, we categorize the whole industry into two groups: one group with sharp temperature effect and the other with weak temperature effect. Furthermore, the industry group with sharp temperature effect is classified into a summer peak industry group and a winter peak industry group, based on the estimates of the temperature response function. These empirical results carry practical policy implications on the real time electricity demand management.

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Experimental Study on Cooling Load Forecast Using Neural Networks (신경회로망을 이용한 일일 냉방부하 예측에 관한 실험적 연구)

  • Shin, Kwan-Woo;Lee, Youn-Seop;Kim, Yong-Tae;Choi, Byoung-Youn
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.61-64
    • /
    • 2001
  • The electric power load during the peak time in summer is strongly affected by cooling load. which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system etc are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested. And also the method of forecasting the cooling load using neural network is suggested. For the simulation, the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated. As a result of the simulation, the forecasted data approached to the actual data.

  • PDF

On the Characteristics of the SO$_2$ Concentration Variation in Pusan, Korea (부산 지역의 SO$_2$ 농도 변화 특성에 관한 고찰)

  • 전병일;김유근;이화운
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.245-251
    • /
    • 1994
  • We considered that characteristics of SO$_2$, concentration level and relations of the meteorological parameters and high pollution concentration from the data measured 7 air quality continuous monitoring stations during 4 years, from 1990 to 1993 in Pusan. The SO$_2$ concentration level showed decreasing trend yearly, it was maximum in Winter, minimum in Summer. The time of SO$_2$ peak concentration lagged from seashore to land because of break-down of the nocturnal inversion layer and seabreeze. Ihe correlations of daily SO$_2$, value between various air quality continuous monitoring stations were highest between Beomcheondong and Meongryundong, lowest between Daeyeondong and Sinpyeongdong because of difference of air Pollution emission sources characteristic. The meteorological parameters affecting SO$_2$ concentration level were minimum temperature, relative humidity, wind speed and air pressure. The SO$_2$ high pollution($\geq$95ppb) occurred almost in Winter, particulaly in such day showing lower wind speed and higher air pressure. Elementary SO$_2$ high Pollution Predictor were high pressure system and stability of lower atmosphere.

  • PDF