The domestic needs for larger capability of power sources are increasing to cope with the expanding power load which results from the industrial developments & the progressed life style. In summer, the peak load is mainly due to the non-industrial reasons such as air-conditioners and other cooling equipments. To cover the concentrated peak load in stable, the power transmission lines should be more constructed and efficiently operated. The ampacity design of the underground cable system is generally following international standards such as IEC287, IEC60853 and JCS168 which regards the shape of 100% daily full power loads. It is not so efficient to neglect the real shapes of load curves generally below 60~70% of full load. The dynamic (real time) rating system tends to be used with the measured thermal parameters which make it possible to calculate the maximum ampacity within required periods. In this paper, the CTM(Conductor Temperature Monitoring) which is the base of dynamic rating systems for tunnel environment is proposed by a design of lumped thermal network ($\pi$-type thermal model) and distribution temperature sensor attached configuration, including the estimation results of its performances by load cycle test on 345kV single phase XLPE cable.
Ice storage systems are used to shift the peak load in day time into night time in summer. This paper describes a system simulation of partial ice storage system composed of an encapsulated ice storage tank, a screw compressor chiller, a heat exchanger, and a brine pump. For the system simulation, a one-dimensional model of ice storage tank is developed and validated by comparison with the performance data from measurements of an ice storage tank installed at a building. The control strategies considered in this study are chiller priority and storage priority being used commercially. The system is simulated with design cooling load of 600 RT peak load in design day and with off-design day cooling load, and the electric energy costs of the two control strategies for the same system size are compared. As a result of calculation, the energy consumption in a week for storage priority is higher than that for chiller priority control. However due to lower cost of night electric charge rate, energy cost for storage priority control is lower than chiller priority.
To characterize organic and elemental carbon (OC and EC), and water-soluble organic carbon (WSOC) contents, daily $PM_{2.5}$ measurements were performed in August 2006 (summer) and Jan $11{\sim}Feb$ 12 2007 (winter) at an urban site of Gwangju. Daily size-segregated aerosol samples were also collected for WSOC analysis. No clear seasonal variations in EC and WSOC concentrations were observed, while seasonal differences in OC concentration, and OC/EC and WSOC/EC ratios were shown. The WSOC/OC ratio showed higher value in summer (0.56) than in winter (0.40), reflecting the greater enhancement of secondary WSOC formation at the site in summer. Secondary WSOC concentrations estimated using EC tracer method were in the range $0.0{\sim}2.1\;{\mu}g/m^3$ (average $0.42\;{\mu}g/m^3$) and $0.0{\sim}1.1\;{\mu}g/m^3\;(0.24\;{\mu}g/m^3)$, respectively, accounting for $0{\sim}51.6%$ (average 16.8%) and $0{\sim}52.5%$ (average 13.1 %) of the measured WSOC concentrations in summer and winter. Sometimes higher WSOC/OC ratio in winter than that in summer could be attributed to two reasons. One is that the stable atmospheric condition often appears in winter, and the prolonged residence time would strengthen atmospheric oxidation of volatile organic compounds. The other is that decrease of ambient temperature in winter would enhance the condensation of volatile secondary WSOC on pre-existing aerosols. In summertime, atmospheric aerosols and WSOC concentrations showed bimodal size distributions, peaking at the size ranges $0.32{\sim}0.56\;{\mu}m$ (condensation mode) and $3.2{\sim}5.6\;{\mu}m$ (coarse mode), respectively. During the wintertime, atmospheric aerosols showed a bimodal character, while WSOC concentrations showed a unimodal pattern. Size distributions of atmospheric aerosols and WSOC with a peak in the size range $0.32{\sim}0.56\;{\mu}m$ were observed for most of the measurement periods. On January 17, however, atmospheric aerosols and WOSC exhibited size distributions with modal peaks in the size range $1.0{\sim}1.8\;{\mu}m$, suggesting that the aerosol particles collected on that day could be expected to be more aged, i.e, longer residence time, than the aerosols at other sampling periods.
원자력발전소 사고 시 방사성물질이 발전소외 지역으로 유출이 되거나 예상될 때 주민을 안전하게 보호하기 위한 조치의 일환으로 주민소개가 고려된다. 소개시간 산정에 필요한 인자를 도출하고, 각각의 인자에 대해 원전 주변의 현장자료를 토대로 부지주변의 교통환경 여건을 반영하여 월성원전의 방사선 비상계획구역 내의 주민전체를 소개시키는데 소요되는 시간을 예측하였다. 월성원전 방사선비상계획구역 내 주요 간선도로와 교차로에서 교통량을 조사하였고, 소개시작시간 분포를 추정하기 위해 상주거주자와 일시거주자를 대상으로 사회행동특성에 대한 설문조사를 실시하였다. 평시와 관광객이 많이 유입되어 차량정체가 예상되는 여름철을 대상으로 주간 및 야간, 평상기상 및 악기상의 경우로 나누어 주민소개시간을 예측하였다. 주민 소개시간 예측을 위한 교통분석은 TSIS 패키지 프로그램이 이용되었다. 비상계획구역 경계 남단과 북단에서 모든 소개차량(인구)이 비상계획구역을 벗어나는 데 걸리는 시간은 전체적으로는 $118{\sim}150$분 정도로 예측되었다. 여름 첨두교통량 유입시, 소개 시간은 낮이 밤보다 최대 17분 정도 더 소요되는 것으로 예측되었다.
Jo, Eunbyeol;Kim, Yong Ha;Moon, Suin;Kwak, Young-Sil
Journal of Astronomy and Space Sciences
/
제36권2호
/
pp.61-68
/
2019
We have investigated the variations of sporadic E (Es) layer using the measurements of digisondes at Icheon ($37.14^{\circ}N$, $127.54^{\circ}E$, IC) and Jeju ($33.4^{\circ}N$, $126.30^{\circ}E$, JJ) in 2011-2018. The Es occurrence rate and its critical frequency (foEs) have peak values in summer at both IC and JJ in consistent with their known seasonal variations at mid-latitudes. The virtual height of the Es layer (h'Es) during equinox months is greater than that in other months. It may be related to the similar variation of meteor peak heights. The h'Es shows the semidiurnal variations with two peaks at early in the morning and late in the afternoon during equinoxes and summer. However, the semi-diurnal variation is not obvious in winter. The semi-diurnal variation is generally thought to be caused by the semi-diurnal tidal variation in the neutral wind shear, whose measurements, however, are rare and not available in the region of interest. To investigate the formation mechanism of Es, we have derived the vertical ion drift velocity using the Horizontal Wind Model (HWM) 14, International Geomagnetic Reference Field, and Naval Research Laboratory Mass Spectrometer and Incoherent Scatter Radar-00 models. Our results show that h'Es preferentially occur at the altitudes where the direction of the vertical ion velocity changes. This result indicates the significant role of ion convergence in the creation of Es.
PVC 파판에서 초기전복치패의 먹이생물인 저서미소조류의 변화를 추정하기 위해 1984년 1월부터 12월까지 France Bourneuf만의 굴 양성지에 파판을 수하하여 파판에 부착 발생된 저소미소조류의 엽록소 a와 갈색소를 분석하였다. 저서미소조류의 생체량을 엽록소의 양으로 추정하고, 생리상태를 갈색소의 백분율로 나타낼때 생체량은 제절에따라 겨울에는 파판의 수하시간에 따라 비례하여 증가하였으나, 고수온기인 여름에는 저서미소조류의 군집이 빠르게 노쇠되어 매 2주마다 최대치를 나타내는 양상을 보였다. 갈색소의 백분율은 봄과 가을에 낮은 비율을 나타내었으나, 여름 고수온기에는 군집의 빠른 노쇠로 인하여 백분율은 최대치를 나타내어 군집의 활성이 저하되었으며, 생체량과 갈색소의 백분율을 고려할 때 5, 6월과 9, 10월에 전복의 산란이 이루어지는 것은 저서미소조류를 먹이로 하는 초기부착치패에게 영양적으로 종은 균형을 이루게 한다.
The dynamics of water quality with the storm events were analyzed in a small reservoir for irrigation, Lake Wangkung. Water quality of the inflowing stream fluctuated seasonally with the variation of flow rate. Thermal stratification was consistent from April to October below 2 m depths and anoxic layer was developed below 2 m depth in summer. The unique feature of temperature showed that thermal stratification was disrupted by a heavy rain event during monsoon, but hypolimnetic hypoxia were reestablished after a few days. Phosphorus and nitrogen increased immediately following storm events. The marked increase may be due to the input of P-rich storm runoff from the watershed. Internal phosphorus loading can be one of the explanations for TP increases in summer. When there was a storm, total populations of phytoplankton and zooplankton was reduced immediately following the storm, indicating possible flushing of algae and zooplankton. After a lag period of low-density the plankton population bloomed to a peak again within five days after the storm. Turbid water in lake became clear again which coincided with the time of the phytoplankton buildup. The results demonstrate that water quality is regulated greatly by rainfall intensity in Lake Wangkung.
본 논문에서는 전력시장에서 원가 이하로 규제되고 있는 소매요금제도의 문제점을 분석하기 위해 규제된 소매요금 대신 시간별 도매시장가격의 변동을 반영하는 실시간 요금제를 도입할 경우 사회후생에 미치는 영항과 이와 같은 소매요금제도의 변화가 한국전력의 손실 규모를 어느 정도 보전할 수 있는지를 추정한다. 전력거래소의 전력통계정보시스템(EPSIS)과 에너지경제연구원 국가에너지통계종합정보시스템(KESIS), 통계청, 한국은행, 기상청의 2008~2010년 통계자료에 기초하여 실질소매가격, 온도, 가구수, 습도 실질 GDP, 그리고 요일 및 공휴일 더미 등을 설명변수로 이용하여 상대적으로 수요가 많은 여름(6~8월)과 겨울(12~2월)의 최대 부하시간대와 최저 부하시간대의 수요패턴을 분석하였다. 회귀분석을 통해 추정된 선형수요함수와 발전기별 한계비용에 기초하여 산정된 계단식 공급함수를 이용하여 규제된 소매요금이 시장균형가격인 실시간 요금으로 전환될 경우의 사회후생 변화를 살펴본 결과, 여름기간(6~8월)에는 사회후생이 약 674억 원 증가하는 것으로 나타났다. 또한 한전손실 총액 중 7,055억 원은 소비자잉여의 이전으로, 나머지 674억 원은 시중손실의 감소로 충당될 수 있음을 확인하였다. 겨울에는 사회후생 증대가 약 2,251억 원에 이르고, 한전의 손실 중 1조 1,743억 원이 소비자잉여의 전가로 보전될 수 있는 것으로 나타나 소매요금의 규제가 사중손실의 발생을 통해 전체 사회후생을 감소시키고, 한전에게 막대한 손실을 초래하고 있다는 결과를 도출하였다.
본 연구에서는 완도 해역에서 단기적인 수온의 변화에 영향을 주는 요인을 파악하기 위하여 시계열 분석을 실시하였다. Power spectrum 결과에서 기온은 약 24 hr에서 peak를 보였으나 수온과 조위는 약 12 hr 및 24 hr에서 peak가 나타났다. 수온과 조위의 상관성을 파악하기 위해 coherence 분석을 실시한 결과, 두 변수는 반일주기에서 0.92로 높은 상관성을 보였다. 또한 수온의 시 공간적인 분포를 파악하기 위하여 수치실험을 실시하였다. 대조기에는 최강 낙조와 최강 창조 시의 평균 수온차가 $0.3^{\circ}C$인 반면, 소조기에는 평균 수온차가 $0.13^{\circ}C$로 작았다. 대조기의 수온차가 큰 이유는 비교적 수온이 낮은 외해수가 강한 조류에 의해 창조 시 유입되고 낙조 시 빠져나가기 때문인 것으로 판단된다. 전반적으로 수온은 외해보다 연안에서 높게 나타났다. 외해보다 연안은 수심이 얕기 때문에 일사량에 의해 수온이 빠르게 증가하기 때문인 것으로 사료된다.
본 논문에서는 신재생 에너지 활용을 위한 그늘막 형태의 연계 계통형 태양광 발전 시스템을 제안한다. 제안하는 발전 시스템은 성하기에 해수욕장을 찾는 피서객들에게 상용전원과 연계 계통하여 최대 전력 수요를 충족시킬 뿐 만 아니라 그늘막으로서의 기능을 갖도록 설계하였다. 태양전지에서 생성된 전기를 낮 시간 동안 축전지에 충전하면 이를 야간에 전등이나 선풍기등에 이용할 수 있다. 축전지를 충전할 때 축전지의 성능을 유지하려면 충방전컨트롤러가 필요하다. 제안하는 축전지 충방전 컨트롤러는 고성능 마이크로프로세서를 사용하여 정확하고 안정된 동작을 하도록 설계하였고 사용자의 편의를 위해 디지털 표시기 및 축전지 교체시기 경보장치등을 갖추고 있다. 제안하는 발전 시스템을 영동 지역 해수욕장에 설치하고 실험을 통하여 전력 생산능력과 발전 성능을 확인하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.