• 제목/요약/키워드: Sulphur hexafluoride

검색결과 12건 처리시간 0.015초

Quantitative Analysis of Microperfusion in Contrast-Induced Nephropathy Using Contrast-Enhanced Ultrasound: An Animal Study

  • Nieun Seo;Hyewon Oh;Hyung Jung Oh;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.801-810
    • /
    • 2021
  • Objective: To investigate imaging biomarkers of microperfusion in contrast-induced nephropathy (CIN) using contrast-enhanced ultrasound (CEUS). Materials and Methods: The CIN model was fabricated by administering indomethacin (10 mg/kg), L-NAME (15 mg/kg), and iopamidol (10 mL/kg) to Sprague-Dawley rats. After 24 hours, CEUS was performed on CIN (n = 6) and control (n = 6) rats with sulphur hexafluoride microbubbles (SonoVue). From time-intensity curves obtained from the kidney arriving time (AT), acceleration time (AC), time to peak (TTP), and peak enhancement (PE) were measured and compared between the groups. After CEUS, the rats were sacrificed, and cell apoptosis markers were evaluated to confirm the development of CIN. Results: Among CEUS parameters, AT (7.8 ± 1.6 vs. 4.2 ± 0.5 s, p = 0.002), AC (4.7 ± 1.4 vs. 2.0 ± 0.4 s, p = 0.002), and TTP (12.5 ± 2.9 vs. 6.2 ± 0.6 s, p = 0.002) were significantly prolonged in the CIN group compared to controls. PE was significantly higher in the control group than in the CIN group (17.1 ± 1.9 vs. 12.2 ± 2.0 dB, p = 0.004). In kidney tissue, mRNA and protein levels of the apoptotic makers were significantly higher in the CIN group than in the control group (p = 0.003 and p = 0.002). Conclusion: CEUS parameters can be used as imaging biomarkers for microperfusion in CIN. In rats with CIN, AT, AC, and TTP were significantly prolonged, while PE was significantly lower compared to controls.

고분자 분리막 재질 변화에 따른 $O_2$, $CF_4$, $SF_6$ 투과도 및 투과선택도 특성 변화에 대한 연구 (Permeation and Permselectivity variation of $O_2$, $CF_4$ and $SF_6$ through Polymeric Hollow Fiber Membranes)

  • 이현정;이민우;이현경;이상협
    • 멤브레인
    • /
    • 제20권3호
    • /
    • pp.249-258
    • /
    • 2010
  • IPCC (Intergonvernmental Pane1 of Climate Change)에서 $CO_2$의 23,900배에 해당하는 지구온난화지수를 가진 $SF_6$ (Sulphur hexafluoride) 가스와 중전기 산업에서 아크 발생에 의해 생긴 $SF_6$의 주요 분해 부산물 중 하나이며 $CO_2$의 6,300배에 해당하는 지구온난화지수를 가진 $CF_4$ (Tetrafluoromethane) 가스의 배출에 대한 규제가 적극 검토되고 있다. 본 연구는 $O_2$, $CF_4$에 대한 $SF_6$의 분리 회수의 기초 연구로써, 상용화된 PSF (polysulfone), PC (tetra-bromo polycarbonate)와 PI (polyimide) 고분자 분리막을 사용하여 $O_2$, $CF_4$$SF_6$ 가스의 압력과 온도 변화에 따른 투과도 및 투과선택도 연구를 수행하였다. 압력 변화에 따른 $O_2$의 투과도는 PSF 중공사 분리막에서 압력 1.1 MPa일 때, 37.5 GPU로 가장 높게 나타났고, $SF_6$$CF_4$의 경우 압력 1.1 MPa에서 PC 중공사 분리막이 각각 2.7 GPU와 2.5 GPU로 가장 높은 투과플럭스를 나타냈다. 온도 변화에 따른 $O_2$의 투과플럭스는 막의 온도가 $45^{\circ}C$일 때 PSF 중공사 분리막이 41.2 GPU로 가장 높게 나타났고, $SF_6$$CF_4$는 막의 온도가 $25^{\circ}C$일 때, PC 중공사 분리막이 각각 2.4 GPU와 2.3 GPU로 가장 높은 투과플럭스를 나타냈다. 압력과 온도 변화에 따른 $O_2/SF_6$$CF_4/SF_6$의 투과선택도 결과, 높은 단일 기체 투과플럭스를 보인 PSF와 PC 중공사 분리막이 가장 낮은 투과선택도를 나타내고, 가장 낮은 투과플럭스를 보인 PI 중공사 분리막이 가장 높은 투과선택도를 나타냄을 확인할 수 있다.