• Title/Summary/Keyword: Sulfur oxide ($SO_x$)

Search Result 10, Processing Time 0.028 seconds

Nitrogen oxide (NOX) and Sulfur Oxide (SOX) Removal Capacities of Textile FabricsCoated with Nano-pore Materials (나노 공극소재로 코팅된 모헤어의 질소산화물(NOX) 및 황산화물(SOX) 제거 성능평가)

  • Lee, Jae-Uk;Yang, Keun-Hyeok;Mun, Ju-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.157-158
    • /
    • 2020
  • The present study examined the effectiveness of textile fabrics coated with nano-pore materials on removing the nitrogen oxide (NOX) and sulfur oxide (SOX) in the atmospheric environment. The tested approach is favorable for absorbing NOX and SOX, even under the washing condition.

  • PDF

Corrosion Behavior of Carbon Steel in Diluted Sulfuric Acid based on Seawater

  • Kim, Mun Su;Jeong, Jin-A
    • Corrosion Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.78-85
    • /
    • 2019
  • The International Maritime Organization (IMO) will administer a new 0.5% global sulfur cap on fuel content from 1 January 2020, lowering from the present 3.5% limit. Seawater $SO_x$ (sulfur oxide) scrubbing is especially spray scrubbing and a promising alternative to complying with the IMO regulation. However, the ionization of $SO_2$ (sulfur dioxide) and the $H_2SO_4$ (sulfuric acid) formed from $SO_3$ (sulfur trioxide) is proposed to accelerate corrosion of the internal seawater pipe. Apparently, the corrosion of the scrubber seawater piping system occurs in a severe and frequent manner. Hence, in this study, electrochemical measurement and weight loss of carbon steel (used as seawater pipe in most of the ships) in diluted sulfuric acid solution were investigated to determine corrosion rate, corrosion current density, corrosion potential, electrochemical behavior, and impressed-current density. Accordingly, the corrosion rate of carbon steel sheet in various diluted sulfuric acid solutions was observed to be greater than that in natural seawater, thus suggesting the fundamental data to deal with corrosion problems in scrubber seawater pipe.

Simultaneous Removal of NO and SO2 using Microbubble and Reducing Agent (마이크로버블과 환원제를 이용한 습식 NO 및 SO2의 동시제거)

  • Song, Dong Hun;Kang, Jo Hong;Park, Hyun Sic;Song, Hojun;Chung, Yongchul G.
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.341-349
    • /
    • 2021
  • In combustion facilities, the nitrogen and sulfur in fossil fuels react with oxygen to generate air pollutants such as nitrogen oxides (NOX) and sulfur oxides (SOX), which are harmful to the human body and cause environmental pollution. There are regulations worldwide to reduce NOX and SOX, and various technologies are being applied to meet these regulations. There are commercialized methods to reduce NOX and SOX emissions such as selective catalytic reduction (SCR), selective non-catalytic reduction (SNCR) and wet flue gas desulfurization (WFGD), but due to the disadvantages of these methods, many studies have been conducted to simultaneously remove NOX and SOX. However, even in the NOX and SOX simultaneous removal methods, there are problems with wastewater generation due to oxidants and absorbents, costs incurred due to the use of catalysts and electrolysis to activate specific oxidants, and the harmfulness of gas oxidants themselves. Therefore, in this research, microbubbles generated in a high-pressure disperser and reducing agents were used to reduce costs and facilitate wastewater treatment in order to compensate for the shortcomings of the NOX, SOX simultaneous treatment method. It was confirmed through image processing and ESR (electron spin resonance) analysis that the disperser generates real microbubbles. NOX and SOX removal tests according to temperature were also conducted using only microbubbles. In addition, the removal efficiencies of NOX and SOX are about 75% and 99% using a reducing agent and microbubbles to reduce wastewater. When a small amount of oxidizing agent was added to this microbubble system, both NOX and SOX removal rates achieved 99% or more. Based on these findings, it is expected that this suggested method will contribute to solving the cost and environmental problems associated with the wet oxidation removal method.

Application of Gas to Particle Conversion Reaction to increase the DeSOx/DeNOx Efficiency under Pulsed Corona Discharge (DeSOx/DeNOx 효율 개선을 위한 펄스 코로나 방전하에서 기체미립자 전환반응의 적용)

  • Choi, Yu-ri;Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.249-258
    • /
    • 1998
  • In this paper, we investigated the post-combustion removal of nitrogen oxide($NO_x$) and sulfur oxide($SO_x$) which is based on the gas to particle conversion process by the pulsed corona discharge. Under normal pressure, the pulsed corona discharge produces the energetic free electrons which dissociate gas molecules to form the active radicals. These radicals cause the chemical reactions that convert $SO_x$ and $NO_x$ into acid mists and these mists react with $NH_3$ to form solid particles. Those particles can be removed from the gas stream by conventional devices such as electrostatic precipitator or bag filter. The reactor geometry was coaxial with an inner wire discharge electrode and an outer ground electrode wrapped on a glass tube. The simulated flue gas with $SO_x$ and $NO_x$ was used in the experiment. The corona discharge reactor was more efficient in removing $SO_x$ and $NO_x$ by adding $NH_3$ and $H_2O$ in the gas stream. We also measured the removal efficiency of $SO_x$ and $NO_x$ in a cylinder type corona discharge reactor and obtained more than 90 % of removal efficiency in these experimental conditions. The effects of process variables such as the inlet concentrations of $SO_x$, $NH_3$ and $H_2O$, residence time, pulse frequencies and applied voltages were investigated.

  • PDF

The Simultaneous absorption of SOX-NOX using aqueous ammonia solution (암모니아수용액을 이용한 SOX-NOX 동시 흡수에 관한 연구)

  • Kim, Jae-Gang;Lee, Ju-Yeol;Park, Byung-Hyun;Choi, Jin-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.372-376
    • /
    • 2015
  • The experiment was performed using the cleaning precipitator To investigate the absorption efficiency of the $SO_X/NO_X$ of the aqueous ammonia solution. Concentration of the cleaning liquid is 0.1, 0.5, and 1.0% with increasing absorption efficiency has improved. However, the reaction shown only a difference in time. Absorption efficiency has improved in accordance with the gas residence time. When the direction of the same gas and the cleaning liquid is determined that there is the effect of increasing the residence time. The relative impact of $SO_X$ and $NO_X$ is this likely to react slower than $SO_X/NO_X$. The yield is determined to require adjustment of the cleaning dust collector according to the concentration of the next gas.

Experimental Study on Reduction of Particulate Matter and Sulfur Dioxide Using Wet Electrostatic Precipitator (습식전기집진기를 활용한 입자상 물질 및 황산화물 저감 성능에 관한 실험적 연구)

  • Kim, Jong-Lib;Oh, Won-Chul;Lee, Won-Ju;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.898-904
    • /
    • 2021
  • This experimental study aims to investigate the use of a wet electrostatic precipitator as a post-treatment device to satisfy the strict emission regulations for sulfur oxides and particulate matter (PM). The inlet/outlet of a wet electrostatic precipitator was installed in a funnel using a marine four-stroke diesel engine (STX-MAN B&W) consuming marine heavy fuel oil (HFO) with a sulfur content of about 2.1%. Measurements were then obtained at the outlet of the wet electrostatic precipitator; an optical measuring instrument (OPA-102), and the weight concentration measurement method (Method 5 Isokinetic Train) were used for the PM measurements and the Fourier transform infrared (FT-IR; DX-4000) approach was used for the sulfur oxide measurements. The experimenst were conducted by varying the engine load from 50%, to 75% and 100%; it was noted that the PM reduction efficiency was a high at about 94 to 98% under all load conditions. Additionally, during the process of lowering the exhaust gas temperature in the quenching zone of the wet electrostatic precipitator, the sulfur dioxide (SO2) values reduced because of the cleaning water, and the reduction rate was confirmed to be 55% to 81% depending on the engine load.

Removal of SO2 over Binary Nb/Fe Mixed Oxide Catalysts (이성분계 Nb/Fe 혼합산화물 촉매에 의한 아황산가스의 제거)

  • Chung, Jong Kook;Lee, Seok Hee;Park, Dae Won;Woo, Hee Chul
    • Clean Technology
    • /
    • v.12 no.2
    • /
    • pp.87-94
    • /
    • 2006
  • The reduction of $SO_2$ to elemental sulfur by CO over a series of iron niobate with nominal Nb/Fe atomic ratios of 1/0, 10/1, 5/1, 1/1, 1/5, 1/10 and 0/1 was studied with a flow fixed-bed reactor. Strong synergistic phenomena in catalytic activity and selectivity were observed for the iron niobate catalysts, and the best catalytic performance was observed for the catalyst with Fe/Nb atomic ratio of 1/1. The active phase of the activated iron niobate catalysts was identified to be $FeS_2$ using XRD and XPS. Selective reduction of $SO_2$ by CO was followed by the COS intermediate mechanism.

  • PDF

A Study on Reduction of Nitrogen Oxide (NOx) and Stability of Incineration Facility by the Food Wastewater Incineration (음식물류 폐수 소각처리에 따른 질소산화물 저감 및 소각설비의 안정성 평가에 관한 연구)

  • Hwang, Seung-Min;Chung, Jin-Do;Song, Jang-Heon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.901-908
    • /
    • 2009
  • We examine the processing method of the food wastewater to direct spray at living waste incinerator. The demoscale stoker system is used as a incineration facility. The results show that it brings effect on the reduction of nitrogen oxide ($NO_x$) concentration as well as the ammonia ($NH_3$) amount in SNCR (selective non-catalytic reduction) by the incineration of food wastewater which is containing a plentiful ammoniac nitrogen ($NH_3$-N). Furthermore, the stability of incineration facility and the extension of operation period is actualized as a improvement of clogging phenomenon on outer wall of water pipe as the 870~$950^{\circ}C$ maintain of exit temperature in a second combustor by spray of the food wastewater. The 26 items of air pollution matter of nitrogen oxide ($NO_x$), sulfur oxide ($SO_x$) and dioxin etc. are measured. The results show that it is under the value of allowable exhaust standard.

Air Pollutants Control Technique Trends for Transportation Sources in Korea (우리나라 이동오염원의 제어기술의 동향과 발전방안)

  • Kim, Jeong-Soo;Eom, Myung-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.477-485
    • /
    • 2013
  • The major source of harmful air pollutants in Korea have been shifted as economy grows. Particulate matter(PM) and Sulfur dioxide ($SO_2$) emitted from industries and coal-fired domestic sectors were important pollutants in 1970's and later industrializing period of Korea. Then the characteristic of pollution was changed into so-called "developed country type pollution". Vehicles have been responsible for significant amount of Nitric oxide ($NO_x$) pollution and consequent Ozone formation in urban area since 1990's. Variety of control measures have been introduced to deal with the vehicle emissions in Seoul Metropolitan Area (SMA). Emission control technologies have successfully reduced pollutants from vehicles. Three-way catalyst for vehicles fueled by gasoline and liquefied petroleum gas (LPG), for example, has achieved large amount of pollutants. Compressed natural gas (CNG) urban bus have penetrated existing diesel bus market and reduces PM and $NO_x$ emissions in many Korean cities. However, diesel vehicles are still reaming as a critical emission source of urban area. Diesel vehicles gain more popularity than ever because of their better fuel efficiency and driving power. Unfortunately, it is widely known that the pollutant emissions of diesel vehicles are much larger than those of gasoline and LPG vehicles. In this note, we briefly introduce the trends of emission control strategies which are accomplished by automotive industries for about last ten years. Emission regulation, cleaner fuel, diesel particulate filter (DPF) and other measures are discussed from technical as well as legislative perspectives.

Hot Corrosion Properties of Heat Resistant Chrome Steels (내열강의 고온부식특성에 대한 크롬함량의 영향)

  • Lee, Han-sang;Jung, Jine-sung;Yoo, Keun-bong;Kim, Eui-hyun
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.4
    • /
    • pp.277-288
    • /
    • 2010
  • The hot corrosion properties of heat-resistant steels were investigated in an oxidation atmosphere including artificial ash and sulfur dioxide. The heat-resistant steels of T22, T92, T122, T347HFG, Super304H and HR3C were evaluated at 620, 670 and $720^{\circ}C$ for 400 hours. The relationship between the corrosion rate and the temperature followed a bell-shaped curve with a peak rate at around $670^{\circ}C$. The corrosion rates showed a decreasing tendency as the chrome contents of these steels increased from 2.15 wt.% to 24.5 wt.%, and austenitic steels had a lower corrosion rate than ferritic steels. Sulfidation by $SO_2$ as well as molten salt corrosion also had an effect on the total corrosion rate, especially showing an increase in the corrosion rate in ferritic steels. Regardless of the chrome content in the steels and irrespective of the test temperature, the corrosion scale was composed of an outer oxide and an artificial ash mixed layer, a middle oxide layer and inner sulfide, and a mixed oxide layer. As the chrome content increased, the proportion of chrome oxide in the corrosion scale increased. Before spalling of the corrosion scale, voids and cracks were initiated in the sulfide and the mixed oxide layer or at the interface with the substrate.