Performance Evaluation of Bench-Scale Sulfur-Oxidizing Autotrophic Denitrificaiton Process Using Different Packing Material and Position in Reactor (담체의 종류와 배열에 따른 회분식 황 산화 탈질공정의 고농도 질산성질소를 함유한 인공폐수의 탈질효율 평가)

  • Sim, Dong-Min;Ahn, Ju-Hyeon;Kim, Seoung-Hyun;Gwon, Eun-Mi;Chung, Wook-Jin;Jin, Chang-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.231-239
    • /
    • 2006
  • In this study, we evaluated the efficiency of using sulfur-$CaCO_3$ complex pellet in the sulfur oxidizing autotrophic denitrification process for synthetic wastewater with high $CaCO_3$ concentration. The sulfur-$CaCO_3$ complex pellet was packed in reactor(R4). Influent ${NO_3}^--N$ loading rate was from 200 to $1,000g/m^3{\cdot}day$. During the operation, average denitrification efficiency of R4 was above 95%. Particularly, the denitrififation rate at $1,000g/m^3{\cdot}day$ loading was 98.96% for R4. High ${NO_3}^--N$ removal efficiency was determined in R4 compared with other reactors. Through $Ca^{2+}$ and alkalinity analyses, we calculated the supplied alkalinity from the packed $CaCO_3$ in the reactor. Sulfur-$CaCO_3$ complex pellet more effectively supplied alkalinity through the dissociation of $CaCO_3$ as compared with other media. Based on these results, sulfur-$CaCO_3$ complex pellet increased the pH buffering capacity while also providing the carbon source to the denitrifying bacteria. Denitrification efficiency of R4 was also higher than other reactors. ESEM pictures of sulfur-$CaCO_3$ complex pellet show higher porosity than that of the granular sulfur. Hence, more denitrifying bacteria attached on the sulfur-$CaCO_3$ complex pellet than on granular sulfur. It can be concluded that the sulfur-$CaCO_3$ complex pellet is a more suitable media for a sulfur oxidizing autotrophic denitrification process as it provides high denitrification efficiency.

Removal of Nitrogen Using by SOD Process in the Industrial Wastewater Containing Fluoride and Nitrogen from the Zirconium Aolly Tubing Production Factory of the Nuclear Industry (원자력산업 지르코늄합금 튜브 생산공장에서 배출되는 불소.질소 함유 폐수의 황산화탈질을 이용한 질소처리)

  • Cho, Nam-Chan;Moon, Jong-Han;Ku, Sang-Hyun;Noh, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.855-859
    • /
    • 2011
  • The main pollutants from zirconium alloy tubing manufacturing process in nuclear industry are nitrate ($NO_3-N$) and fluoride (F-)Nitric acid, and hydrofluoric acid is used for acid pickling. The process for the removal of nitrate and fluoride is composed of 1st chemical coagulation, SOD (Sulfur Oxidation Denitrification) process using sulfur-oxidizing denitrification, and 2nd chemical coagulation. The characteristic of the wastewater treatment is an application of SOD process. The SOD Process is highly received attention because it is significantly different from existing processes for sulfur denitrification. A JSC (JeonTech-Sulfur- Calcium) Pellet is unification of sulfur and alkalinity material. According to result of SOD process in wastewater treatment plant, the removal efficiency of T-N was over 91% and the average concentration of T-N from influent was 147.55 mg T-N/L and that from effluent was 12.72 mg T-N/L. Therefore, SOD process is a useful to remove nitrogen from inorganic industrial wastewater and a new development of microbial activator was shown to be stable for activation of autotrophic bacteria.

A Study on the Removal of Nitrogen and Phosphorus by Addition of Coagulant in the Sulfur Denitrification Process Coupled to the Membrane Bioreactor (MBR과 황탈질 공정에서 응집제 주입에 따른 질소.인 제거에 관한 연구)

  • Lee, Young-Ho;Yoo, Soung-Jong;Oh, Dae-Min;Lee, Young-Sin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.949-956
    • /
    • 2010
  • A method for simultaneous removal of nitrogen and phosphate from sewage by elemental sulfur denitrification with membrane bioreactor was proposed, and capacity $10\;m^3$/day of pilot plant was operated for 350 days. This study was investigated to have the effect of denitrification rate and T-P removal with the addition of Alum in Sulfur denitrification Reactor (SDR). The addition of Alum and alkalinity ($NaHCO_3$) in the effluent of MBR was tried to remove simultaneous phosphate and nitrogen in SDR. Characteristics of total nitrogen (T-N) and total phosphate (T-P) removal was compared without and with the addition of Alum as a coagulant. T-N removal without and with the addition of Alum was 92.1% and 87.8%, respectively. And denitrification efficiency was 93.8% and 87.1%, respectively. T-P removal rate was increased to 75.6% in SDR by addition of Alum (2.6~4 mg/L as Al), but T-P removal rate was about 26.7% without the addition of Alum. Therefore, denitrification rate was 6.7% of reduction but T-P removal rate was increased by addition of Alum.

MATHEMATICAL MODEL OF SULFUR UTILIZING AUTOTROPHIC DENITRIFICATION IN AN UP-FLOW PACKED-BED REACTOR BASED ON BIOMASS DISTRIBUTION

  • Park, Woo-Shin;Ahn, Yoeng-Hee;Jung, Kyung-Ja;Tatavarty, Rameshwar;Kim, In-S.
    • Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.191-198
    • /
    • 2005
  • A novel technology for the removal of nitrogen from wastewater, an autotrophic denitrification process with sulfur particles, has been developed. A respirometer was employed to monitor the nitrogen gas produced in the reactor, while 4',6-diamidino-2-phenylindole staining was employed to investigate the biomass distribution in terms of cell number according to the reactor height. From the respirometric monitoring, the denitrification reaction was defined as a first order reaction. The reactor was divided into 7 sections and biomass was analyzed in each section where cell number was ranged from $4.8\;{\times}\;10^6\;to\;8.7\;{\times}\;10^7$ cells/g dry weight of sulfur. Cells placed mostly in the lower layer ( < 10 cm of height). A function for biomass distribution was obtained with non-linear regression. Then a mathematical model has been developed by combining a plug-flow model with the biomass distribution function. The model could make a vertical profile of the up-flow packed-bed reactor resulting in a reasonable comparison with measured nitrate concentration with 5% of error range.

Development of High-rate Nitrogen Removal Process Using Submerged MBR Packed with Granular Sulfur of Pilot Scale Plant (Pilot Scale Plant의 황 충진 MBR을 이용한 고효율의 질소제거 공법 개발)

  • Mun, Jin-Yeong;Hwang, Yong-U;Jo, Hyeon-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.383-390
    • /
    • 2011
  • In this study, a process combined biofiltration with sulfur-utilizing autotrophic denitrification and membrane separation was proposed to examine the efficiency of nitrogen removal. As an experimental device, hollow-fiber module was installed in the center of reactor to generate the flux forward sulfur layer in the cylinder packed with granular sulfur. In addition, a simple module was installed in activated sludge aeration tank which inside and outside of sulfur-using denitrification module was covered with microfilter and the module was considered as an alternative of clarifier. The experiment for developing new MBR process was carried out for three years totally. As the results of first two-year experiment, successful nitrogen removal performance was revealed with lab-scale test and pliot scale plant using artificial wastewater and actual plating wastewater. In this year, pilot scale test using actual domestic wastewater was performed to prove field applicability. As the results, high-rate nitrogen removal performance was confirmed with about 0.19 kg ${NO_3}^--N/m^3$ day of rate. Also significant fouling and pressure increase were not found during the experiment. And, the production ratio of sulfate and the consumption ratio of alkalinity showed a slightly higher value about 311 mg ${SO_4}^{2-}/L$ and 369 mg $CaCO_3$/L, respectively. In conclusion, the developed MBR process can be utilized as an alternative for retrofiting existing wastewater plants as well as new construction of advanced sewage wastewater treatment plants, with cost-effective merit.

A Study by Proposal of Efficiency Increase for a Full-scale Wastewater Reclamation Facility using a Biofilter Packed with Granular Sulfur (하수처리수 재이용을 위한 실규모 입상황 생물막여과 시설의 효율증대 방안에 관한 연구)

  • Moon, Jin-Young;Hwang, Yong-Woo;Baek, Seung-Ryun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.73-83
    • /
    • 2010
  • This study was performed to increase the removal efficiency of the biofilter packed with granular sulfur in municipal wastewater reclamation facility. Constituent units were influent water tank, denitrification tank, BOD reduction tank and outlet. And, the major operation factor is a biofilter packed with submerged granular sulfur. Actual wastewater and synthetic wastewater were used as influent wastewater. Experimental condition was divided into two phases according to the amount of a phosphorus coagulant. Total phosphorus removal efficiency was insignificant at mode I that phosphorus coagulant was not injected. The average influent and effluent total phosphorus concentrations at mode II were 0.5 ~ 1.0 mg/L and 0.27 mg/L, respectively. As for COD and BOD effluent concentrations, COD was 3.0 mg/L and BOD was 1.0 mg/L. Additionally, nitrogen removal rates were high at low influent DO concentration. In conclusion, a new process, biofilter packed with granular sulfur is expected to treat high-rate nitrogen wastewater and expected to be utilized as an alternative of technological innovation for the nitrogen treatment.

High-Rate Biological Nitrogen Removal from Plating Wastewater using Submerged MBR Packed with Granular Sulfur (황 충진 MBR을 이용한 도금폐수의 고효율 생물학적 질소 제거)

  • Kim, Dae-young;Moon, Jin-young;Baek, Jin-uk;Hwang, Yong-woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.200-208
    • /
    • 2005
  • In this study, a new submerged membrane bioreactor process packed with granular sulfur (MBR-GS) was operated to identify the biological nitrogen removal behaviors with plating wastewater containing high-strength $NO_3{^-}$ concentration. The continuous denitrification was carried out at $20^{\circ}C$ with various nitrogen loading rates using synthetic wastewater, which composed of $NO_3{^-}$ and $HCO_3{^-}$, but also actual plating wastewater, which was collected from the effluent of the H metal plating company. As a result, high-rate denitrification in the range of $0.8kg\;NO_3{^-}-N/m^3\;day$ was accomplished at nitrogen loading rate of $0.9kg\;NO_3{^-}-N/m^3\;day$ using synthetic wastewater. Also, higher-rate denitrification with actual plating wastewater was achieved up to $0.91kg\;NO_3{^-}-N/m^3\;day$ at the loading rate of $1.11kg\;NO_3{^-}-N/m^3\;day$. Additionally, continuous filtration was possible during up to 30 days without chemical cleaning in the range of 20 cmHg of transmembrane pressure. On the basis of the proposed stoichiometry, ${SO_4}^{2-}$ production could be estimated efficiently, while observed alkalinity consumption was somewhat lower than theoretical value. Consequently, a new process, MBR-GS is capable of high-rate autotrophic denitrification by compulsive flux and expected to be utilized as an alternative of renovation techniques for nitrogen removal from not only plating wastewater but also municipal wastewater with low C/N ratio.

A Study on Denitrification by Sulfur-Oxidizing Bacteria for the Industrial Wastewater Contain Fluoride and Nitrogen (불소.질소 함유 폐수의 황산화탈질에 관한 연구)

  • Cho, Nam-Chan;Moon, Jong-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.774-781
    • /
    • 2011
  • Nitric acid and hydrofluoric acid are used for acid pickling in zirconium alloy tubing manufacturing process. Nitrate and fluoride in the wastewater were treated by chemical coagulation and SOD (Sulfur Oxidation Denitrification) process. This study is investigated the effect of fluoride concentration and the optimal condition for SOD process. The limited fluoride concentration for SOD process was below 20 mg F-/L. The adjusted pH and alkalinity by NaOH and $NaHCO_3$ was shown to be more effective for removal of nitrate compared with using NaOH. Furthermore, the microbial activator mixed trace elements and ingredient for alkalinity did not only supplement with alkalinity but also enhance the growth and proliferation for sulfur-oxidizing bacteria. As a result, the inorganic industrial wastewater was successfully treated by the microbial activator in SOD process without continuous addition of seed sludge. Finally, SOD process was shown to remove nitrate in industrial wastewater and to contribute the microbial activator for activation of sulfur-oxidizing bacteria.

Evaluation of Denitrification Efficiency by Sulfur Denitrification Process according to Injection Type (유입방식 변화에 따른 황 탈질조의 탈질효율 평가)

  • Yoo, Tae-Kyoung;Choi, Yong-Bum;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.262-269
    • /
    • 2016
  • This study examined the influent of a sulfur denitrification reactor using nitrified effluent from a batch type reactor. The denitrification efficiency was compared according to the injection type. The nitrogen removal effects were compared with the changes in the EBCT and nitrogen concentration of the influent to determine the optimal operation conditions with the selected injection type. A denitrification efficiency evaluation of a reactor according to the change in injection type and up-flow was performed using a lower organic concentration of the effluent than the down-flow because of the re-precipitation of desorbed microbes and spilled solids. In the up-flow type, organics were controlled by the low concentration than the down-flow type because of solid re-precipitation. The T-N removal efficiency of the up-flow type was 73.3~90.2%, which was more that 10% higher that down-flow type. This means that the up-flow type has a great advantage in removing T-N and organics. The T-N removal efficiency by EBCT at 1hr was 47.3%, and was 88.1% and 90.5% by EBCT 3hr and 5hr, respectively. Therefore, the optimal operation conditions to remove nitrogen was considered to be EBCT for 3hr. After careful consideration of rule of law and T-N removal effects, the T-N load factor in the reactor should remain below $0.443kgT-N/m^3{\cdot}day$ to maintain the legal total nitrogen concentration for discharge, which is 20mg/L.