• Title/Summary/Keyword: Sulfur Corrosion

Search Result 98, Processing Time 0.022 seconds

Study on the Suppression of Sulfur Trioxide in High Sulfur Boiler (고유황 보일러에서의 Sulfur Trioxide의 억제에 대한 연구)

  • Choi, Sung-Bu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.455-463
    • /
    • 2011
  • The average sulfur content of crude oil is 2.2%. Coal is about 0.3 to 4.0 percent of the sulfur gases or particles being discharged into the atmosphere through the chimney as 1 to 2% $SO_3$(Sulfur trioxide) and about 95% of the $SO_2$ is reported. $SO_3$ gas, which has many different causes of, as the combustion of sulfur containing fuel during the air due to the excess $SO_2$ gas is oxidized to $SO_3$ gas. Sulfur trioxide emitted from high sulfur heavy oil fired boiler caused white plume in stack and high temperature and cold end corrosion of facilities. So, in order to control sulfur trioxide concentration of Fuel gas in boiler, various of additives are used in other foreign. They are injected to Fuel Oil and consumed in boiler and reduce ash and the conversion rate of sulfur trioxide. In domestic, MgO compounds are used as additives but the total volume of them are made from other foreign company. In this study, MgO compounds were developed with liquid MgO compounds and field application was accomplished. The effect of newly developed chemicals and process were nearly equal to foreign products. In Consequent, the chemicals and process produced by newly developed technology can be substituted for foreign products and reduce the cost of plant operation.

Stress Corrosion Cracking of Alloys 600, 690, and 800 in a Tetrathionate Solution at $340^{\circ}C$

  • Lee, Eun-Hee;Kim, Kyung-Mo
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.587-588
    • /
    • 2006
  • The stress corrosion cracking (SCC) susceptibility of Alloy 600 MA, Alloy 600 TT, Alloy 800, and Alloy 690 TT were investigated in a deaerated 0.01 M solution of sodium tetrathionate using reverse u-bend test samples at $340^{\circ}C$. The results showed that SCC occurred in all alloys, excluding Alloy 690 TT. The SCC susceptibility decreased with an increase in the chromium content of the alloys. The results of the deposits and spectra taken from an energy dispersive X-ray system confirmed the existence of a reduced sulfur causing SCC.

  • PDF

A Study On the Corrosion Tendency of Bottom Plates and Corrosion Prevention Measures in Hazmat Tanks (위험물저장탱코밑판의 부식 성향분석 및 부식예방 방안에 관한 연구)

  • Choi, Jeong Soo;Ro, Kyung Jin
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.1
    • /
    • pp.138-152
    • /
    • 2008
  • The most important factor in the maintenance of chemical industry facilities is related with deterioration and corrosion. Leakage of hazardous materials is likely to occur because the confirmation and maintenance of bottom plates are very difficult while the bottom corrosion of the massive hazmat-storage facilities is most dangerous especially. As a result of the analysis of the corrosion locations, areas, usage condition of 287 hazmat-storage tanks on this syudy, it is concluded that the main external corrosion factors are the inflow of moisture and the materials inducing corrosion in the air such as sodium chloride and the main internal corrosion factors are corrosion react caused by stay of seawater, sulfur and moisture in hazmat for a long time without appropriate discharges. It is anticipated that the corrosion of bottom plates can be restrained effectively by establishing the proper measures for the each corrosion cause.

  • PDF

An Experimental Study on the Fundamental Properties and Durability of Sewer Type Restorative Mortar Spread with Antibiotics (항균제를 도포한 하수시설용 단면복구 모르타르의 기초물성 및 내구특성에 관한 실험적 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Kim, Jae-Hwan;Cho, Bong-Suk;Lee, Dong-Heck
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.195-202
    • /
    • 2006
  • Deterioration of sewer concrete is representative that biochemical corrosion according to the $H_2S$ has growth by inhabit sulfur-oxidzing bacteria because of special environment in sewer. But in case of domestic, fundamentally, sulfur-oxidzing bacteria could moderate development of repair material method is need because of corrosion prevent method is inconsideration with carry out to improve project. In this paper, after development of spread type antibiotic with antibio-metal, antibacterial performance about sulfur-oxidzing bacteria of antibiotic and tested to estimate fundamental properties of bonding strength, abrasion contents, contents of water absorption, contents of air permeability, carbonation depth, chloride ion penetration depth and chemical resistance of spread with antibiotic restorative mortar.

Discharge Properties of Sodium-sulfur Batteries at Room Temperature (상온용 나트륨/유황전지의 방전 특성)

  • Kim, T.B.;Ahn, H.Y.;Hur, H.Y.
    • Korean Journal of Materials Research
    • /
    • v.16 no.3
    • /
    • pp.193-197
    • /
    • 2006
  • The sodium/sulfur(Na/S) battery has many advantages such as high theoretical specific energy(760Wh/kg), and low material cost based on the abundance of electrode material in the earth. It has been reported that the electrochemical properties of sodium/sulfur cell above $300^{\circ}C$, utilized a solid ceramic electrolyte and liquid sodium and sulfur electrodes. A lot of researches have been performed in this field. Recently, Na/S battery system was applied for electricity storage system for load-leveling. One of severe problems of sodium/sulfur battery was high operating temperature above $300^{\circ}C$, which could induce the explosion and corrosion by molten sodium, sulfur and polysulfides. In order to develop sodium battery operated at low temperature, sodium ion battery has been studied using carbon anode, and sodium oxides cathodes. However, the energy densities of the sodium ion batteries were much lower than high temperature sodium/sulfur cell. In this study, the sodium/sulfur battery with 1M $NaCF_3SO_3$ is tested at room temperature. The charge-discharge mechanism was discussed based on XRD, DSC, SEM and EDS results.

Abrief study on the corrosion of bronze roofing tile (납(Pb)도금(동개와)의 부식 연구)

  • Kim, Sa-Dug
    • 보존과학연구
    • /
    • s.15
    • /
    • pp.52-58
    • /
    • 1994
  • To protect corrosion of bronze roofing tile for Choson Royal Historic Museum, lead coating on tile was performed by electroplating method with thickness of $35\mum$. Lead coated tile samples were inverstigated what corrosion products were formed with color changes on them by testing Accelerated Weathering. No sulfides were formed on samples contacting with 300ppm sulfur dioxide and any color changes were not found. In Accelerated Weathering test, White hydrocerussite, basic lead carbonate($2PbCO_3Pb(OH)_2$) having protective structure made of compact adhering crystals.

  • PDF

A Study on Grooving Corrosion at the Weld of a Low Carbon Steel Pipe Made by Electrical Resistance Welding (탄소강관의 ERW 용접부 홈부식 손상에 관한 연구)

  • Kim Yong;Lee Bo-Young
    • Journal of Welding and Joining
    • /
    • v.22 no.5
    • /
    • pp.58-64
    • /
    • 2004
  • Although leakage at a low carbon steel pipe made by electrical resistance welding (ERW) was reported due to grooving corrosion, the cause for the corrosion has not yet been cleared. In order to clarify the main cause, failure analysis on the leaked pipe was carried out, followed by metallographic investigation and corrosion test for the various ERW pipe made with different welding heat input. The microstructure, particularly inclusion content, of the weldment is dependant on the welding heat input applied. For an improper low heat input, the amount of inclusion at the weld was high. High inclusion content accelerated grooving corrosion at the weld. It is therefore that welding heat input should be controlled based on the carbon content of the pipe in order to improve the corrosion resistance of the ERW pipe.

Corrosion Behavior of Galvanized Steels with Outdoor Exposure Test in Korea for 36 Months (36개월간 국내 옥외폭로시험에 따른 아연도강의 부식거동)

  • Kim, K.T.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.231-241
    • /
    • 2018
  • Atmospheric corrosion is generally an electrochemical degradation process of metal. It can be caused by various corrosion factors of atmospheric component, weather, and air pollutants. Moisture, particles of sea salts, and sulfur dioxide are major factors in atmospheric corrosion. Galvanizing coating is one of the most efficient ways to protect iron from corrosion by zinc plating on the surface of the iron. Galvanized steels are being widely used in automobiles, building structures, roofing, and other industrial structures due to their high corrosion resistance compared to bare iron. Atmospheric corrosion of galvanized steel has shown complex corrosion behavior depending on coating process, coating thickness, atmospheric environment, and air pollutants. In addition, different types and kinds of corrosion products can be produced depending on the environment. Lifespan of galvanized steels is also affected by the environment. Therefore, the objective of this study was to determine the corrosion behavior of galvanized steel under atmospheric corrosion at six locations in Korea. When the exposure time was increased, content of zinc from GA surface decreased while contents of iron and oxygen tended to increase. On the other hand, content of iron was constant even after 36 months of exposure of GI.

Accelerated Prediction Methodologies to Predict the Outdoor Exposure Lifespan of Galvannealed Steel

  • Kim, Ki Tae;Yoo, Young Ran;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.86-91
    • /
    • 2019
  • Generally, atmospheric corrosion is the electrochemical degradation of metal that can be caused by various corrosion factors of atmospheric components and weather, as well as air pollutants. Specifically, moisture and particles of sea salt and sulfur dioxide are major factors in atmospheric corrosion. Using galvanized steel is one of the most efficient ways to protect iron from corrosion by zinc plating on the surface of the iron. Galvanized steel is widely used in automobiles, building structures, roofing, and other industrial structures due to their high corrosion resistance relative to iron. The atmospheric corrosion of galvanized steel shows complex corrosion behavior, depending on the plating, coating thickness, atmospheric environment, and air pollutants. In addition, corrosion products are produced in different types of environments. The lifespans of galvanized steels may vary depending on the use environment. Therefore, this study investigated the corrosion behavior of galvannealed steel under atmospheric corrosion in two locations in Korea, and the lifespan prediction of galvannealed steel in rural and coastal environments was conducted by means of the potentiostatic dissolution test and the chemical cyclic corrosion test.

An Experimental Study on Durability of Concrete Covered with Antibiotics (항균제를 도포한 콘크리트의 내구특성에 관한 실험적 연구)

  • Lee Eui-Bae;Lee Dong-Heck;Moon Hyung-Jae;Kim Jae-Hwan;Kim Gyu-Yong;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.97-100
    • /
    • 2005
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent the growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, durability such as resistance to carbonation, salt damage and chemical attack of concrete covered with inorganic and complex antibiotics were investigated. As a result of this study, it was proved that the antimicrobial performance of antibiotics was available. Also resistance to carbonation, salt damage and chemical attack of concrete covered with inorganic antibiotics was little improved but, in case of complex antibiotics, was remarkably improved. Moisture content of concrete, as a application condition of antibiotics in whole case, have little effect on performance but covering times of antibiotics have effect on performance only in case of complex antibiotics.

  • PDF