• Title/Summary/Keyword: Sulfide recognition

Search Result 9, Processing Time 0.023 seconds

New Application of 2-(4-N-Phenyl-3-thiosemicarbazone)-8-hydroxyquinoline as a Sensor for Relay Recognition of Cu2+ and Sulfide in Aqueous Solution

  • Tang, Lijun;Zhou, Pei;Huang, Zhenlong;Zhao, Jia;Cai, Mingjun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.2905-2908
    • /
    • 2013
  • Fluorescent and colorimetric recognition properties of 2-(4-N-phenyl-3-thiosemicarbazone)-8-hydroxyquinoline (1) in buffered aqueous solution (1% DMSO, HEPES 20 mM, pH = 7.4) have been examined. Sensor 1 displays highly selective and sensitive recognition to $Cu^{2+}$ with fluorescence "ON-OFF" performance. The in situ formed 1-$Cu^{2+}$ complex exhibits an excellent selectivity toward sulfide ions with fluorescence "OFF-ON" behavior via $Cu^{2+}$ displacement approach. Thus, relay recognition of $Cu^{2+}$ and sulfide by a known molecule 1 has been achieved.

A New Quinoline-Based Acylhydrazone for Highly Selective Fluorescence Recognition of Cu(II) and Sulfide in Aqueous Solution

  • Tang, Lijun;Zhou, Pei;Qi, Zhikai;Huang, Zhenlong;Zhao, Jia;Cai, Mingjun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2256-2260
    • /
    • 2013
  • A new quinoline-based acylhydrazone (1) has been synthesized and applied as a fluorescent probe. Probe 1 exhibits high selectivity and sensitivity to $Cu^{2+}$ with fluorescence "ON-OFF" behavior in HEPES buffered (1‰ DMSO, HEPES 20 mM, pH = 7.4) solution. The on-site generated 1-$Cu^{2+}$ complex displays excellent selectivity to sulfide ions with fluorescence "OFF-ON" performance through copper displacement approach.

Measurement of Low Hydrogen Sulfide Concentrations in the Coastal Area Near the Ulsan Industrial Complex (울산 산업단지인근 해변지역에서의 저 농도 황화수소 측정)

  • Yu, Mee Seon;Yang, Sung-Bong
    • Journal of Environmental Science International
    • /
    • v.25 no.11
    • /
    • pp.1555-1562
    • /
    • 2016
  • Concentrations of hydrogen sulfide in ambient air have been measured from January 2014 to June 2016 in a coastal area near the Ulsan National Industrial Complex. The measurement sites were 1 km, 2.6 km, 5.6 km, and 20 km away from a kraft pulp mill, which is located at the most southern edge of the complex. Concentrations above 0.4 ppb were monitored every 5 min and the highest concentration of the day was determined. From a total of 775 measurement days, hydrogen sulfide concentrations > 20 ppb were recorded on 36 and 38 days at the measurement site closest to the mill and the residential area 2.6 km away from the mill, respectively. At the site farthest from the mill, the concentrations were always 20 ppb lower than the malodor regulation for the residential area but sometimes higher than the odor recognition threshold for hydrogen sulfide. Although several emission sources of hydrogen sulfide have been published in the Pollutant Release and Transfer Register of Korea, the kraft pulp mill is considered to be the biggest contributor of atmospheric hydrogen sulfide in the southern coastal area of Ulsan.

A Bioreactor for the Effective Removal of the Hydrogen Sulfide from Biogas (바이오가스에 포함된 고농도 황화수소의 효율적 제거를 위한 미생물반응기)

  • Namgung, Hyeong-Kyu;Yoon, Chang No;Song, JiHyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.811-817
    • /
    • 2013
  • A two-stage bioreactor system using sulfur-oxidizing bacteria was studied to abate high strength hydrogen sulfide ($H_2S$) from biogas. The two-stage bioreactor consisted of a $H_2S$ absorption column (0.5 L) and a microbial oxidation column (1 L) in series, and the liquid medium was continuously recirculated through the columns. The objectives of this study were to determine the feasibility of the bioreactor for biogas desulfurization and to investigate the effect of the medium circulation rate on the system performance. An averaged concentration of $H_2S$ introduced to the bioreactor was 530 ppm, corresponding to an overall loading rate of $44.4g/m^3/hr$. During the initial 20 days period at the medium recirculation rate of 8 reactor volumes per hour (12 L/hr), the dissolved oxygen (DO) concentration in the oxidation column was 6 mg/L, while the DO in the absorption column was 0.5 mg/L showing that the oxygen contents of the biogas stream was not altered. Because of the biological oxidation of $H_2S$ in the oxidation column, the sulfate concentration increased from 200 mg/L to 5,600 mg/L in the liquid medium. The removal efficiency of $H_2S$ was greater than 99% in the initial operation period. After the initial period, the medium recirculation rate between the two columns was stepwise changed eight times from 1.0 to 40 vol/hr (1.5~60 L/hr). At the recirculation rate of faster than 4 vol/hr, the $H_2S$ removal efficiencies were found to be high, but the efficiency declined at the lower recirculation rates than the threshold.

Research study on the grade of subjective symptom and recognition of oral malodor of women's college students or co-eds (여대생의 구취자각정도와 인지에 관한 조사 연구)

  • Kim, Sun-Sook;Lee, Eun-Sook;So, Mi-Hyun;Woo, Hee-Sun;Jun, Soo-Gyeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • I investigated the situation of self-realization for oral malodor and real occurrence of it and researched the situation of coincidence by self-administrated questionnaire and real oral malodor of dental hygiene students in Kyeonggi province and Kyeongbuk province to use as a reference data on prevention and treatment of oral malodor. The obtained results were as follows: 1. Concerning the grade of the subjective symptom of oral odor, a little bit oral malodor was the highest by reaching 77.6%, and no oral malodor was 20%. 2. The time when one feels the oral malodor highest was revealed immediately after awakening from the sleep by running up to 88.2%. 3. Concerning the extent of aversion during the occurrence of oral malodor from other people, 57.6% expressed as unpleasant, and 3.5% showed no aversion. 4. Concerning the intention to participate in the prevention program against the oral malodor, 51.8% had intention of it. 5. Hydrogen sulfide 7.61V19.30, methyl mercaptan 9.53V67.90, dimethyl sulfide 58.31V121.37(pF0.05) marked as causing factors in the 132 respondents who answered that they had a little bit oral malodor in comparison with the grade of subjective symptom and the measurement of actual oral malodor. As the above-mentioned results were obtained by limited subjects, the more diversified and precise comparative study is considered to be needed through the classification of various levels of research subjects.

  • PDF

Molecular cloning and expression analysis of a C-type lectin in the rock bream, Oplegnathus fasciatus

  • Kwon, Mun-Gyeong;Kim, Ju-Won;Park, Myoung-Ae;Hwang, Jee-Youn;Park, Hyung-Jun;Park, Chan-Il
    • Journal of fish pathology
    • /
    • v.25 no.1
    • /
    • pp.11-20
    • /
    • 2012
  • C-type lectins are crucial for pathogen recognition, innate immunity, and cell-cell interactions. In this study, a C-type lectin gene was cloned from the rock bream. The full-length RbCTL cDNA was 729 bp with a 429 bp ORF encoding a 164-residue protein. The deduced amino acid sequence of RbCTL had all of the conserved features crucial for its fundamental structure, including the four cysteine residues involved in sulfide bridge formation and potential $Ca^2+$/carbohydrate-binding sites. RbCTL contains a signal peptide one single carbohydrate recognition domain. It showed 29.4% similarity to the C-type lectin of rainbow trout. RbCTL mRNA was predominately expressed in gill and head-kidney tissue and expressed less in peripheral blood leukocytes, trunk-kidney, spleen, liver, intestine and muscle. Expression of RbCTL was differentially upregulated in rock bream stimulated with LPS, Con A/PMA and poly I:C.

Development of piezoelectric immunosensor for the rapid detection of marine derived pathogenic bacteria, Vibrio vulnificus

  • Hong, Suhee;Jeong, Hyun-Do
    • Journal of fish pathology
    • /
    • v.27 no.2
    • /
    • pp.99-105
    • /
    • 2014
  • Biosensors consist of biochemical recognition agents like antibodies immobilized on the surfaces of transducers that change the recognition into a measurable electronic signal. Here we report a piezoelectric immunosensor made to detect Vibrio vulnificus. A 9MHz AT-cut piezoelectric wafer attached with two gold electrodes of 5mm diameter was used as the transducer of the QCM biosensor with a reproducibility of ${\pm}0.1Hz$ in frequency response. We have tried different approaches to immobilize antibody on the sensor chip. Concerning the orientation of antibody for the best antigen binding capacity, the antibody was immobilized by specific binding to protein G or by cross-linking through hydrazine. In addition, protein G was cross-linked on glutaraldehyde activated immine layer (PEI) or EDC/NHS activated sulfide monolayer (MPA). PEI was found to be more effective to immobilize protein G following glutaraldehyde activation than MPA. However, hydrazine chip showed a better capability to immobilize more IgG than protein G chip and a higher sensitivity. The sensor system was able to detect V. vulnificus in dose dependent manner and was able to detect bacterial cells within 5 minutes by monitoring frequency shifts in real time. The detection limit can be improved by preincubation to enrich the bacterial cell number.

Development of Gas Measurement System for the Harmful Gases at Livestock Barn (축산생육환경 유해가스 모니터링을 위한 무선가스측정시스템 개발)

  • Kim, Young Wung;Paik, Seung Hyun;Park, Hong Bae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.314-321
    • /
    • 2012
  • Harmful gases which are generated from various rout at growth environment of livestock ban have a direct and indirect bad influence to the livestock and farmers, and also step-up breeding density and long-term exposure to the sealed environment of winter can be fatal. In this paper, we propose a gas measurement system for monitoring gases of ammonia, hydrogen sulfide, volatile organic compounds, etc. which arise from the muck. The measurement system consist of both wireless gas sensor node and gas recognition software using a Fuzzy Min-Max neural network. To evaluate the performance of suggested system, gas measurement experiments are performed in laboratory environment by using the designed wireless gas sensor node. And we show the performance through classification test for the target gases by the designed gas recognition software.

Recent Developments in Metal Oxide Gas Sensors for Breath Analysis (산화물 반도체를 이용한 최신 호기센서 기술 동향)

  • Yoon, Ji-Wook;Lee, Jong-Heun
    • Ceramist
    • /
    • v.22 no.1
    • /
    • pp.70-81
    • /
    • 2019
  • Breath analysis is rapidly evolving as a non-invasive disease recognition and diagnosis method. Metal oxide gas sensors are one of the most ideal platforms for realizing portable, hand-held breath analysis devices in the near future. This paper reviewed the recent developments in metal oxide gas sensors detecting exhaled biomarker gases such as nitric oxides, acetone, ammonia, hydrogen sulfide, and hydrocarbons. Emphasis was placed on strategies to tailor sensing materials/films capable of highly selective and sensitive detection of biomarker gases with negligible cross-response to ethanol, the major interfering breath gas. Specific examples were given to highlight the validity of the strategies, which include optimization of sensing temperature, doping additives, utilizing acid-base interaction, loading catalysts, and controlling gas reforming reaction. In addition, we briefly discussed the design and optimization method of gas sensor arrays for implementing the simultaneous assessment of multiple diseases. Breath analysis using high-performance metal oxide gas sensors/arrays will open new roads for point-of-care diagnosis of diseases such as asthma, diabetes, kidney dysfunction, halitosis, and lung cancer.