• Title/Summary/Keyword: Sulfide

Search Result 1,551, Processing Time 0.031 seconds

Synthesis and electrochemical properties of cobalt sulfide-graphene oxide nanocomposites by hydrothermal method (수열합성법을 이용한 코발트 황화물-산화그래핀 나노복합체 제조 및 전기화학적 특성 연구)

  • Su Hwan Jeong;Joo-Hyung Kim
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.6
    • /
    • pp.203-209
    • /
    • 2023
  • Cobalt sulfide nanocomposites were synthesized through a simple hydrothermal method as anode materials for sodium ion batteries (SIBs). In this work, a cobalt sulfide nanoparticle (CoS-NF) and a cobalt sulfide nanocomposite integrated with reduced graphene oxide (CoS@G-NC) were fabricated for electrochemical energy storage performance of battery. The as-prepared CoS@G-NC electrode exhibited reversible and stable cycle performance (62 % after 30 cycles at current density of 200 mA g-1). The improved electrochemical property was attributed to the small grain growth and uniform distribution of cobalt sulfide during synthesis, which maximized the diffusion pathway for sodium ions and effectively suppressed the delamination and volume expansion of cobalt sulfide during the conversion reaction. The results provide promising anode materials for next-generation SIBs.

Semi-pilot Scaled Biofilter Treatment of Malodorous Waste Air Containing Hydrogen Sulfide and Ammonia: 2. Performance of Biofilter Packed with Media Inoculated with a Consortium of Separated Microbes (황화수소와 암모니아를 함유한 악취폐가스의 세미파일럿 규모 바이오필터 처리: 2. 분리 미생물들을 접종한 담체를 충전한 바이오필터 운전)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.240-246
    • /
    • 2014
  • A semi-pilot biofilter inoculated with the microbes consortium of Bacillus cereus DAH-1056 and Arthrobacter sp. KDE-0311 was operated under various operating conditions in order to treat malodorous waste air containing both hydrogen sulfide and ammonia. When both hydrogen sulfide and ammonia contained in malodorous waste air were treated simultaneously by semi-pilot biofilter inoculated with Thiobacillus sp. IW and return-sludge, the removal efficiencies of hydrogen sulfide and ammonia were ca. 80% and ca. 50%, respectively. On the other hand, in this study, the removal efficiencies of hydrogen sulfide and ammonia were ca. 90% and ca. 60%, respectively. Therefore, the removal efficiencies of hydrogen sulfide and ammonia were enhanced by ca. 13% and 20%, respectively, compared to the semipilot biofilter inoculated with Thiobacillus sp. IW and return-sludge. In addition, in this study, the maximum elimination capacities of hydrogen sulfide and ammonia were enhanced by ca. 15% ($8g/m^3/h$) and 10~17% ($3{\sim}5g/m^3/h$), respectively. In this study, it was observed either that in case of even a same inlet load of hydrogen sulfide, a higher concentration of hydrogen sulfide causes more difficulties in treating ammonia containing in waste air than a lower one, or that in case of even a same inlet load of ammonia, a lower concentration of ammonia results in higher removal efficienciy and elimination capacity than a higher one. Even though hydrogen sulfide and ammonia were treated simultaneously by a biofilter in this study, the maximum elimination capacity of hydrogen sulfide in this study exceeded or was similar to that in previous study of biofilter treating only hydrogen sulfide. In addition, this study showed the higher maximum elimination capacity of ammonia than other previous investigation of biofilter treating hydrogen sulfide and ammonia simultaneously.

Semi-pilot Scaled Hybrid Process Treatment of Malodorous Waste Air: Performance of Hybrid System Composed of Biofilter Packed with Media Inoculated with Thiobacillus sp. IW and Return-sludge and Photocatalytic Reactor (악취폐가스의 세미파일럿 규모 하이브리드 공정 처리: Thiobacillus sp. IW 및 반송슬러지를 접종한 담체를 충전한 바이오필터와 광촉매반응기로 구성된 하이브리드시스템의 운전)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.191-198
    • /
    • 2014
  • A semi-pilot hybrid system composed of a photocatalytic reactor and a biofilter was operated under various operating conditions in order to treat malodorous waste air containing both hydrogen sulfide and ammonia which are major air pollutants emitted from composting factories and many publicly owned treatment works (POTW). When both hydrogen sulfide and ammonia contained in malodorous waste air were treated simultaneously by a biofilter system, its performance of ammonia removal was much more poor than that by a biofilter system treating waste air containing only ammonia, unlike its performance of hydrogen sulfide removal. For semi-pilot hybrid system, the removal efficiencies of hydrogen sulfide and ammonia turned out to be ca. 83 and 65%, respectively. Therefore, for semi-pilot hybrid system, the removal efficiencies of hydrogen sulfide and ammonia was increased by ca. 4 and 30%, respectively, compared to those of semi-pilot biofilter system (control). In addition, the maximum elimination capacities of hydrogen sulfide and ammonia for semi-pilot hybrid system turned out to be ca. 60 and $37g/m^3/h$, respectively. These maximum elimination capacities of hydrogen sulfide and ammonia were estimated to be ca. 9.1% and ca. 23.3% greater than those for semi-pilot biofilter system (control), respectively. Therefore, the semi-pilot hybrid system contributed the enhancement of removal efficiency and the maximum elimination capacity of ammonia in a higher degree than that of hydrogen sulfide, compared to the semi-pilot biofilter system.

Analysis of halitosis components following by subjective cognition of halitosis and oral state (주관적인 구취인식도와 구강환경에 따른 구취성분과의 관계 분석)

  • Shin, Kyoung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.2
    • /
    • pp.263-275
    • /
    • 2011
  • Objectives : This study was performed analysis of Halitosis components following by subjective cognition of halitosis and Oral State in order to provide basic data for halitosis prevention and establish a device to efficiently eliminate halitosis and analyze the factors that affect the halitosis. Methods : 80 adults were participated who visited at the Dental Clinic in Kyoung-gi do, on the period of the March to September in 2010. The obtained results, through the oral examination, halitosis check and interview, Individually, were as followings. Results : According to the ammonia level was a high relationship between sex, CPI, Tongue plaque, DMFT index which were statistically significant (p<0.05). Total oral gas level was a relationship between VAS, tongue plaque, DMFT index(p<0.05). The Correlation coefficient between the Hydrogen sulfide level and Methyl mercaptan was estimated as r=0.534(p<0.01). As for the multiple regression analysis result, there have been selected dimethyl sulfide and Tongue plaque, Gingival index as factors affecting Bridge, Methyl mercaptan level is as factors affecting Hydrogen sulfide level. Conclusions : There was relationship between the periodontal disease and Ammonia gas component, hydrogen sulfide, dimethyl sulfide, methyl mercaptan. Which were statistically significant total oral gas level and oral variables. Such dental caries as the prevention or early treatment of periodontal disease.

Synthesis of conducting and magnetic nanocomposite of cross-linked aniline sulfide resin

  • Hosseini, Seyed Hossein
    • Advances in materials Research
    • /
    • v.3 no.4
    • /
    • pp.233-242
    • /
    • 2014
  • Magnetic and conducting aniline sulfide resin cross-linked (ASC-Fe3O4) nanocomposite has been prepared in the presence of aniline sulfide resin (ASR), aniline, $Fe_3O_4$ coated by polyethylene glycol (PEG) and initiator. The magnetic properties of the resulting composites showed ferromagnetic behavior, such as high-saturated magnetization (Ms= 41 emu/g), and coercive force (Hc=1.5 Oe). The saturated magnetization was increased by increasing of $Fe_3O_4$ content and decreased by increasing aniline ratio. The transmission electron micrograph (TEM) and X-ray diffraction proved that nanometer-sized about 20-30 nm $Fe_3O_4$ in the composite. The average size of ASC-$Fe_3O_4$ nanocomposite with core-shell structure was about 50-60 nm, and polydisperse. This approach may also be extended to the synthesis and modification of other polymers. Electrical conductivity of aniline sulfide resin cross-linked (ASC) nanocomposite has been studied by four-point probe method and produced $3.3{\times}10^{-4}S/cm$ conductivity for it. The conductivity of the composites at room temperature depended on the $Fe_3O_4$, aniline ratio and doping degree. The thermogravimetry analysis (TGA) results showed that this resin is thermal resistance near of $500^{\circ}C$. So, It can be used for resistance thermal coating for military applications. $Fe_3O_4$-PASC nanocomposite has been flexible structure with electrical and magnetic properties.

Electrical Characteristic of AI/AIN/GaAs MIS capacitor Fabricated by Reactive Sputtering Method for the (NH4)2S Treatment (반응성 스퍼터링법으로 AI/AIN/GaAs 커패시터 제조시 (NH4)2S 처리에 따른 전기적 특성)

  • Chu, Soon-Nam;Kwon, Jung-Youl;Park, Jung-Cheul;Lee, Heon-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.8-13
    • /
    • 2007
  • In MIS capacitor structure, we have studied the electrical properties in Ammonium Sulfide solution treatment while AIN thin film as a insulator is being formed by reactive sputtering method. The deposition process conditions of AIN thin film we temperature $250^{\circ}C$, DC Power 150 W, pressure 5 mTorr and 8 sccm(Ar : 4 sccm, $N_{2}$ : 4 sccm). The surface of GaAs was treated with Ammonium Sulfide solution, it was shown the leakage current was less than $10^{-8}\;A/cm^{2}$. The deep depletion phenomena of inverse area with treating Ammonium Sulfide solution in C-V analysis was improved as compared the condition of without Ammonium Sulfide solution and hysteresis property as well.

Utilization of biofilter/photo-catalytic reactor system for the simultaneous treatment of hydrogen sulfide and toluene from waste-air

  • Lim, Kwang-Hee;Ping, Wang Zhi;Lim, Dong-Joon;Lee, Eun-Ju
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.287-292
    • /
    • 2005
  • Transient behavior of biofilter/photo-catalytic reactor system was observed to eliminate both hydrogen sulfide and toluene from waste air at its four sampling ports. The biofilter was packed with a equivolume mixture of granular activated carbon(GAC) and compost as packing media on which Thiobacillus sp. IW and Burkholderia cepacia G4 were inoculated and were fixed. The biofilter/photo-catalytic reactor system was run for eight stages of operation under various operating conditions. As a result the removal efficiencies of hydrogen sulfide and toluene began to decrease from 100% after the inlet loads of hydrogen sulfide and toluene surpassed ca. 100 $S-g/m^{3}/h$ and $161g/m^{3}/h$, respectively, and were rapidly decreased to 60% after the inlet loads of hydrogen sulfide and toluene were increased to 200 $S-g/m^{3}/h$ and $644g/m^{3}/h$, respectively.

  • PDF

By the GNC Solution, Removal Effect Offensive Odorous Compounds Generated from Food (GNC용액을 이용한 음식물 쓰레기처리장에서 발생되는 악취 규제물질 제거 효과에 관한 연구)

  • Hong, Jong-Soon;Kim, Jae-Woo
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.2
    • /
    • pp.35-40
    • /
    • 2007
  • It disposes positively in the air pollution damage which is serious, in order help period the place where it improves the quality of existence and life of the local residents. It removed the offensive odor regulation material and the technique it will be able to prevent to sleep it researched it did. After scattering the GNC solution which develops the offensive odor regulation material which occurs from the food and trash treatment plant which is located to the S from the H, company after scattering the GNC solution which it develops collection it did a control criminal record control kind air and it analyzed. In this study, we investigated the emission concentrations of offensive odorous compounds of hydrogen sulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide, trimethylamine, formaldehyde, acetaldehyde, propionaldehyde, buthylaldehyde, iso-valeric aldehyde, n-valeric aldehyde, ammonia. The concentrations of odorous compounds are determined by gas chromatography, HPLC and uv-vis spectroscopy. Hydrogen sulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide were not detected at any point examined.

A study of the sulfide stress corrosion cracking characteristic of A106 Gr B steep pipe weldment (황화수소환경에서 A106 Gr-B 강 용접부의 응력부식균열 특성 평가)

  • Lee, Gyu-Young;Park, Kwang-Jin;Bae, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.114-119
    • /
    • 2007
  • Sulfide stress cracking (SSC) of materials exposed to oilfield environment containing hydrogen sulfide $(H_{2}S)$ has been recognized as a materials failure problem. Laboratory data and field experience have demonstrated that extremely low concentration of $H_{2}S$ may be sufficient to lead to SSC failure of susceptible materials. In some cases, $(H_{2}S)$ can act synergistically with chlorides to produce corrosion and cracking failures. SSC is a form of hydrogen embrittlement that occurs in high strength steels and in localized hard zones in weldment of susceptible materials. In the heat-affected zones adjacent to welds, there are often very narrow hard zones combined with regions of high residual stress that may become embrittled to such an extent by dissolved atomic hydrogen. On the base of understanding on sulfide stress cracking and its mechanism, SSC resistance for the several materials, those are ASTM A106 Gr B using in the oil industries, are evaluated.

  • PDF

Ex-situ Reductive Dechlorination of Carbon Tetrachloride by Iron Sulfide in Batch Reactor

  • Choi, Kyung-Hoon;Lee, Woo-Jin
    • Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.177-183
    • /
    • 2008
  • Ex-situ reductive dechlorination of carbon tetrachloride (CT) by iron sulfide in a batch reactor was characterized in this study. Reactor scaled-up by 3.5 L was used to investigate the effect of reductant concentration on removal efficiency and process optimization for ex-situ degradation. The experiment was conducted by using both liquid-phase and gas-phase volume at pH 8.5 in anaerobic condition. For 1 mM of initial CT concentration, the removal of the target compound was 98.9% at 6.0 g/L iron sulfide. Process optimization for ex-situ treatment was performed by checking the effect of transition metal and mixing time on synthesizing iron sulfide solution, and by determining of the regeneration time. The effect of Co(II) as transition metal was shown that the reaction rate was slightly improved but the improvement was not that outstanding. The result of determination on the regeneration time indicated that regenerating reductant capacity after $1^{st}$ treatment of target compound was needed. Due to the high removal rates of CT, ex-situ reductive dechlorination in batch reactor can be used for basic treatment for the chlorinated compounds.