• Title/Summary/Keyword: Suk-Mun

Search Result 771, Processing Time 0.025 seconds

The Study on Properties and Application of Enhanced Dynamic Wedge Factor (향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰)

  • Kim, Dae-Sup;Ban, Tae-Joon;Yeom, Mi-Suk;Yoo, Soon-Mi;Lee, Woo-Seok;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • Purpose: We try to calculate EDW-factor easily with the formula applies essential data of EDW-factor and evaluate the validity through a measurement. Materials and Methods: We used the given value of GSTT (Golden Segmented Treatment Table) for the calculation of the EDW-factor. As to the experimental device, 0.6 cc farmer-type ion-chamber, an electrometer and water- phantom were used. A measurement was made at the maximum dose depth of the photon beam energy 6 MV and 15 MV under the condition that SSD (Source to Surface Distance) was 100 cm. The angle of the EDW (Enhanced Dynamic Wedge) which we use in an experiment was 60 degree, 30 degree, 20 degree in the Y1-OUT direction. We used Eclipse planning system (Varian, USA) as RTP system and the EDW-factor was calculated about all fields and EDW direction. In order to show the EDW-factor feature, a measurement was made at the selected field that verify the influence of the dependability about X, Y jaw and off-axis field. Results: When we change the Y1 field, it influence on the EDW-Factor and measured value. But the error between measured values and calculated values was less than 1%. The experimental result indicated the tendency that the error of the result of calculation and measured value becomes smaller as the EDW angle become smaller whether the calculation point (measurement point) and iso-center are same or not. The influence of the field size and energy did not show up. We simulated with the same condition using the RTP system. And we found that it makes no difference between the MU which is calculated manually by applying the EDW-Factor obtained from the commercial program and the value which is calculated by using RTP system. Conclusion: We excluded fitting value from well-known EDW-Factor formula and calculated EDW-factor with the formula applies essential data of EDW-factor only. As a result, there are no significant difference between the measured value and calculated value and it showed errors less than 1%. Also, we implemented the commercial program to calculate EDW-Factor conveniently without measure a factor on each field.

  • PDF

Evaluation of Uncertainty of IMRT QA Using 2Dimensional Array Detector for Head & Neck Patients (두경부암에서 2차원 배열 검출기를 이용한 IMRT QA의 불확실성에 대한 연구)

  • Ban, Tae-Joon;Lee, Woo-Suk;Kim, Dae-Sup;Baek, Geum-Mun;Kwak, Jung-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.97-102
    • /
    • 2011
  • Purpose: IMRT QA using 2Dimensional array detector is carried out with condition for discrete dose distribution clinically. And it can affect uncertainty of evaluation using gamma method. We analyze gamma index variation according to grid size and suggest validate range of grid size for IMRT QA in Hospital. Materials and Methods: We performed QA using OniPro I'mRT system software version 1.7b on 10 patients (head and neck) for IMRT. The reference dose plane (grid size, 0.1 cm; location, [0, 0, 0]) from RTP was compared with the dose plane that has different grid size (0.1 cm, 0.5 cm, 1.0 cm, 2.0 cm, 4.0 cm) and different location (along Y-axis 0 cm, 0.2 cm, 0.5 cm, 1.0 cm). The gamma index variation was evaluated by observing the level of changes in Gamma pass rate, Average signal, Standard deviation for each case. Results: The average signal for each grid size showed difference levels of 0%, -0.19%, -0.04%, -0.46%, -8.32% and the standard deviation for each grid size showed difference levels of 0%, -0.30%, 1.24%, -0.70%, -7.99%. The gamma pass rate for each grid size showed difference levels of 0%, 0.27%, -1.43%, 5.32%, 5.60%. The gamma evaluation results according to distance in grid size range of 0.1 cm to 1.0 cm showed good agreement with reference condition (grid size 0.1 cm) within 1.5% and over 5% in case of the grid size was greater than 2.0 cm. Conclusion: We recognize that the grid size of gamma evaluation can make errors of IMRT QA. So we have to consider uncertainty of gamma evaluation according to the grid size and apply smaller than 2 cm grid size to reduce error and increase accuracy clinically.

  • PDF

Study on Computerized Treatment Plan of Field-in-Field Intensity Modulated Radiation Therapy and Conventional Radiation Therapy according to PBC Algorithm and AAA on Breast Cancer Tangential Beam (유방암 접선조사에서 PBC 알고리즘과 AAA에 따른 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy 전산화 치료계획에 대한 고찰)

  • Yeom, Mi-Suk;Bae, Seong-Soo;Kim, Dae-Sup;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.11-14
    • /
    • 2012
  • Purpose: Anisotropic Analytical Algorithm (AAA) provides more accurate dose calculation regarding impact on scatter and tissue inhomogeneity in comparison to Pencil Beam Convolution (PBC) algorithm. This study tries to analyze the difference of dose distribution according to PBC algorithm and dose calculation algorithm of AAA on breast cancer tangential plan. Materials and Methods: Computerized medical care plan using Eclipse treatment planning system (version 8.9, VARIAN, USA) has been established for the 10 breast cancer patients using 6 MV energy of Linac (CL-6EX, VARIAN, USA). After treatment plan of Conventional Radiation Therapy plan (Conventional plan) and Field-in-Field Intensity Modulated Radiation Therapy plan (FiF plan) using PBC algorithm has been established, MU has been fixed, implemented dose calculation after changing it to AAA, and compared and analyzed treatment plan using Dose Volume Histogram (DVH). Results: Firstly, as a result of evaluating PBC algorithm of Conventional plan and the difference according to AAA, the average difference of CI value on target volume has been highly estimated by 0.295 on PBC algorithm and as a result of evaluating dose of lung, $V_{47Gy}$ and $V_{45Gy}$ has been highly evaluated by 5.83% and 4.04% each, Mean dose, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$ has been highly evaluated 0.6%, 0.29%, 6.35%, 10.23% each on AAA. Secondly, in case of FiF plan, the average difference of CI value on target volume has been highly evaluated on PBC algorithm by 0.165, and dose on ipsilateral lung, $V_{47Gy}$, $V_{45Gy}$, Mean dose has been highly evaluated 6.17%, 3.80%, 0.15% each on PBC algorithm, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$ has been highly evaluated 0.14%, 4.07%, 4.35% each on AAA. Conclusion: When calculating with AAA on breast cancer tangential plan, compared to PBC algorithm, Conformity on target volume of Conventional plan, FiF plan has been less evaluated by 0.295, 0.165 each. For the reason that dose of high dose region of ipsilateral lung has been showed little amount, and dose of low dose region has been showed much amount, features according to dose calculation algorithm need to be considered when we evaluate dose for the lungs.

  • PDF

A Study on the Effectiveness of the Manufacture of Compensator and Setup Position for Total Body Irradiation Using Computed Tomography-simulator's Images (전산화 단층 모의치료기(Computed Tomography Simulator)의 영상을 이용한 TBI(Total Body Irradiation) 자세 잡이 및 보상체 제작의 유용성에 관한 고찰)

  • Lee Woo-Suk;Park Seong-Ho;Yun In-Ha;Back Geum-Mun;Kim Jeong-Man;Kim Dae-Sup
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.147-153
    • /
    • 2005
  • Purpose : We should use a computed tomography-simulator for the body measure and compensator manufacture process was practiced with TBI's positioning in process and to estimate the availability.,Materials and Methods : Patient took position that lied down. and got picture through computed tomography-simulator. This picture transmitted to Somavision and measured about body measure point on the picture. Measurement was done with skin, and used the image to use measure the image about lungs. We decided thickness of compensator through value that was measured by the image. Also, We decided and confirmed position of compensator through image. Finally, We measured dosage with TLD in the treatment department.,Results : About thickness at body measure point. we could find difference of $1{\sim}2$ cm relationship general measure and image measure. General measure and image measure of body length was seen difference of $3{\sim}4$ cm. Also, we could paint first drawing of compensator through the image. The value of dose measurement used TLD on head, neck, axilla, chest(lungs inclusion), knee region were measured by $92{\sim}98%$ and abdomen, pelvis, inquinal region, feet region were measured by $102{\sim}109%$.,Conclusion : It was useful for TBI's positioning to use an image of computed tomography-simulator in the process. There was not that is difference of body thickness measure point, but measure about length was achieved definitely. Like this, manufacture of various compensator that consider body density if use image is available. Positioning of compensator could be done exactly. and produce easily without shape of compensator is courted Positioning in the treatment department could shortened overall $15\{sim}20$ minute time. and reduce compensator manufacture time about 15 minutes.

  • PDF

P53 Overexpression and Outcome of Radiation Therapy in Head & Neck Cancers (두경부종양 환자에서 p53의 과발현과 방사선치료결과)

  • Kim In Ah;Choi Ihl Bhong;Kang Ki Mun;Jang Ji Young;Kim Kyung Mi;Park Kyung Shin;Young Shin Kim;Kang Chang Suk;Cho Seung Ho;Kim Hyung Tae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • Purpose : Experimental studies have implicated the wild type p53 In cellular response to radiation. Whether altered p53 function can lead to changes in clinical radiocurability remains an area of ongoing study. This study was performed to investigate whether any correlation between change of p53 and outcome of curative radiation therapy in patients with head and neck cancels. Methods : Immunohistochemical analysis with a mouse monoclonal antibody (DO-7) specific for human p53 was used to detect to overexpression of protein in formalin fixed, paraffin-embedded tumor sample from 55 head and neck cancer patients treated with curative radiation therapy (median dose of 7020 cGy) from February 1988 to March 1996 at 51. Mary's Hospital. Overexpression of p53 was correlated with locoregional control and survival using Kaplan-Meier method. A Cox regression multi-variate analysis was peformed that included all clinical variables and status of p53 expression. Results : Thirty-seven (67.2$\%$) patients showed overexpression of p53 by immunohistochemical staining in their tumor. One hundred percent of oral cavity, 70$\%$ of laryngeal, 66.7$\%$ of oropharyngeal, 66.7$\%$ of hypopharyngeal cancer showed p53 overexpression (P=0.05). The status of p53 had significant relationship with stage of disease (P=0.03) and history of smoking (P=0.001). The overexpression of p53 was not predictive of response rate to radiation therapy. The locoregional control was not significantly affected by p53 status. Overexpression of p53 didn't have any prognostic implication for disease free survival and overall survival. Primary site and stage of disease were significant prognostic factors for survival. Conclusions : The p53 overexpression as detected by immunohistochemical staining had significant correlation with stage, primary site of disease and smoking habit of patients. The p53 overexpression didn't have any predictive value for outcome of curative radiation therapy in a group of head and neck cancers.

  • PDF

Competitive ELISA for the Measurement of Glycoprotein Purified from Acanthopanx senticosus (가시오가피로부터 분리한 단백 다당물질의 경쟁적 ELISA법에 의한 분석)

  • Ha, Eun-Suk;Hwang, Soo-Hyun;Shin, Kwang-Soon;Yu, Kwang-Won;Lee, Keyung-Ho;Choi, Joo-Sun;Park, Woo-Mun;Yoon, Taek-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1209-1215
    • /
    • 2003
  • This study was carried out to establish a quantitative analysis method of separating immuno-activating substance (EN-SP) from Acanthopanax senticosus (A. senticosus) by competitive direct ELISA. Mouse antiserum (anti-EN-SP) against EN-SP was generated by immunization (s.c.) of EN-SP purified from A. senticosus as an immunogen. The titer of anti-EN-SP was about 1 : 400, and the optimal dilution of EN-SP-HRP conjugate was 1 : 1,000. When the standard curve was constructed by ELISA, its sensitivity was about $0.2{\mu}g/mL$. The coefficient variation of intra- and inter-assay were $6.13{\sim}8.81%$ and $6.73{\sim}8.60%$, respectively. According to the standard curve, the concentration of EN-SP in various senticosus extracts was found to be only $59.85\;{\mu}g$ in 10mg of extract from the bark of A. senticosus. Similarly, the immunostimulating activity to produce $TNF-{\alpha}$ or IL-12 among the various extracts of Acanthopanax was shown to be correlated with the content of EN-SP. These results demonstrated that competitive ELISA was a convenient, fast, reproducible, and accurate method for the determination of EN-SP as an immunologically active standard substance in extract of A. senticosus.

Analysis on Subjective Image Quality Assessments for 4K-UHD Video Viewing Environments (4K-UHD 비디오 시청환경 특성분석을 위한 주관적 화질평가 분석)

  • Park, In-Kyung;Ha, Kwang-Sung;Kim, Mun-Churl;Cho, Suk-Hee;Cho, Jin-Soo
    • Journal of Broadcast Engineering
    • /
    • v.15 no.4
    • /
    • pp.563-581
    • /
    • 2010
  • In this paper, we perform subjective visual quality assessments on UHD video for UHD TV services and analyze the assessment results. Demands for video services have been increased with availabilities of DTV, Internet and personal media equipments. With this trend, the demands for high definition video have also been increasing. Currently, 2K-HD ($1920{\times}1080$) video have been widely consumed over DTV, DVD, digital camcoders, security cameras and other multimedia terminals in various types, and recently digital cinema contents of 4K-UHD($3840{\times}2160$) have been popularly produced and the cameras, beam projects, display panels that support for 4K-UHD video start to come out into multimedia markets. Also it is expected that 4K-UHD service will appear soon in broadcasting and telecommunications environments. Therefore, in this paper, subjective assessments of visual quality on resolutions, color formats, frame rates and compression rates have been carried to provide basis information for standardization of signal specification of UHD video and viewing environments for future UHDTV. As the analysis on the assessments, UHD video exhibits better subjective visual quality than HD by the evaluators. Also, the 4K-UHD test sequences in YUV444 shows better subjective visual quality than the 4K-UHD test sequences in YUV422 and YUV420, but there is little perceptual difference on 4K-UHD test sequences between YUV422 and YUV420 formats. For the comparison between different frame rates, 4K-UHD test sequences of 60fps gives better subjective visual quality than those of 30fps. For bit-depth comparison, HD test sequences in 10-bit depth were little differentiated from those in 8-bit depth in subject visual quality assessment. Lastly, the larger the PSNR values of the reconstructed 4K-UHD test sequences are, the higher the subjective visual quality is. Against the viewing distances, the differences among encoded 4K-UHD test sequences were less distinguished in longer distances from the display.

Sargassum sp. Attenuates Oxidative Stress and Suppresses Lipid Accumulation in vitro (모자반추출물의 항산화활성 및 지방세포 생성억제 효과)

  • Kim, Jung-Ae;Karadeniz, Fatih;Ahn, Byul-Nim;Kwon, Myeong Sook;Mun, Ok-Ju;Kim, Mihyang;Lee, Sang-Hyeon;Yu, Ki Hwan;Kim, Yuck Yong;Kong, Chang-Suk
    • Journal of Life Science
    • /
    • v.24 no.3
    • /
    • pp.274-283
    • /
    • 2014
  • Oxidative stress causes tissue damage and facilitates the progression of metabolic diseases, including diabetes, cardiovascular heart diseases, and obesity. Lipid accumulation and obesity-related complications have been observed in the presence of extensive oxidative stress. As part of an ongoing study to develop therapeutic supplements, Sargassum sp. were tested for their ability to scavenge free radicals and intracellular reactive oxygen species (ROS), as well as to suppress lipid accumulation. Three species, S. hemiphyllum, S. thunbergii, and Sargassum horneri, were shown to scavenge free radicals in a di(phenyl)-(2,4,6-trinitrophenyl)iminoazanium (DPPH) assay. In addition, Sargassum sp. was shown to scavenge intracellular ROS and to decrease nitric oxide (NO) production in $H_2O_2$ and lipopolysaccharide (LPS)-induced in RAW264.7 mouse macrophages, respectively. Taken together, the results suggest that Sargassum sp. possess huge potential to relieve oxidative stress and related complications, as well as lipid-induced oxidation. They indicate that S. hemiphyllum, S. thunbergii, and S. horneri are potent functional supplements that can produce beneficial health effects through antioxidant and antiobesity activities, with S. hemiphyllum being the most potent among the Sargassum sp. tested. A potential mechanism for the effect of Sargassum sp. on the suppression of lipid accumulation in differentiating 3T3-L1 mouse preadipocytes through deactivation of the peroxisome proliferator-activated receptor ${\gamma}$ (PPAR ${\gamma}$) is presented.

Operating Characteristics of 1 $Nm^3/h$ Scale Synthetic Natural Gas(SNG) Synthetic Systems (1 $Nm^3/h$ 규모 합성천연가스(SNG) 합성 시스템의 운전 특성)

  • Kim, Jin-Ho;Kang, Suk-Hwan;Ryu, Jae-Hong;Lee, Sun-Ki;Kim, Su-Hyun;Kim, Mun-Hyun;Lee, Do-Yeon;Yoo, Yong-Don;Byun, Chang-Dae;Lim, Hyo-Jun
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.491-497
    • /
    • 2011
  • In this work, we proposed the three different reactor systems for evaluating of synthetic natural gas(SNG) processes using the synthesis gas consisting of CO and $H_2$ and reactor systems to be considered are series adiabatic reaction system, series adiabatic reaction system with the recirculation and cooling wall type reaction system. The maximum temperature of the first adiabatic reactor in series adiabatic reaction system raised to 800. From the these results, carbon dioxide in product gas as compared to other systems was increased more than that expected due to water gas shift reaction(WGSR) and the maximum $CH_4$ concentration in SNG was 90.1%. In series adiabatic reaction system with the recirculation as a way to decrease the temperature in catalyst bed, the maximum $CH_4$ concentration in SNG was 96.3%. In cooling wall type reaction system, the reaction heat is absorbed by boiling water in the shell and the reaction temperature is controlled by controlling the amount of flow rate and pressure of feed water. The maximum $CH_4$ concentration in SNG for cooling wall type reaction system was 97.9%. The main advantage of the cooling wall type reaction system over adiabatic systems is that potentially it can be achieve almost complete methanation in one reactor.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF