• Title/Summary/Keyword: Suitable site selection

Search Result 111, Processing Time 0.029 seconds

Status of Exotic Plant Species in Gyeongju Yangdong Village (경주 양동마을의 외래식물 현황)

  • Kim, Gi Song;Shin, Hyun Tak;Yi, Myung Hun;Yoon, Jung Won;Kim, Yong Shik
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.1
    • /
    • pp.174-189
    • /
    • 2012
  • This study aims to examine the traditional living space to reflect the environment-friendly design methods and principles of reestablishment. To do so, this study carried on a related literature study and field survey. The traditional living space in terms of the environmental friendliness is reflected on site selection and space composition, and utilization of natural energy and natural materials. Focused on the Kwangajeong in Yangdong Village, this study is to identify eco-friendly techniques on the traditional living space. As a result, it shows that Kwangajeong with the side of the southeast in site selection had been considered in aspect of environmental control such as sunshine and solar radiation. Also building construction techniques had been used to minimize the variation of terrain. In aspect of environmental conservation, Kwangajeong had structurally arranged the gate, an inner yard and an inner floor to allow good ventilation. In aspect of space composition, Kwangajeong with the emphasis of scenic view had utilized the methods that attract external landscape through the control of its fences. Environment-friendly techniques and control principles in traditional space had been developed by a long experience through the long periods and the traditional techniques suitable for local climate and local environment have been developed. The technical development of these techniques to resolve the global environmental and energy issues and create a more pleasant living environment of human beings might be critical.

A Study on the Environment-friendly Planning Elements on High-Class Houses Kuangajeong in Chosun Dynasty (관가정(觀稼亭)으로 본 조선시대 상류주택의 환경친화적 계획요소 분석)

  • Heo, Jun;Lee, Shi Young;Song, Byeong Hwa
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.3
    • /
    • pp.164-177
    • /
    • 2011
  • This study aims to examine the traditional living space to reflect the environment-friendly design methods and principles of reestablishment. To do so, this study carried on a related literature study and field survey. The traditional living space in terms of the environmental friendliness is reflected on site selection and space composition, and utilization of natural energy and natural materials. Focused on the Kwangajeong in Yangdong Village, this study is to identify eco-friendly techniques on the traditional living space. As a result, it shows that Kwangajeong with the side of the southeast in site selection had been considered in aspect of environmental control such as sunshine and solar radiation. Also building construction techniques had been used to minimize the variation of terrain. In aspect of environmental conservation, Kwangajeong had structurally arranged the gate, an inner yard and an inner floor to allow good ventilation. In aspect of space composition, Kwangajeong with the emphasis of scenic view had utilized the methods that attract external landscape through the control of its fences. Environment-friendly techniques and control principles in traditional space had been developed by a long experience through the long periods and the traditional techniques suitable for local climate and local environment have been developed. The technical development of these techniques to resolve the global environmental and energy issues and create a more pleasant living environment of human beings might be critical.

Studies on the Growth Range and Optimum Site Determination of the Tree Species Using Climatological Factors in Korea (기상인자(氣象因子)에 의한 우리나라 삼림수종(森林樹種)의 생육범위(生育範圍) 및 적지적수(適地適樹)에 관한 연구(研究))

  • Noh, Eui Rae
    • Journal of Korean Society of Forest Science
    • /
    • v.62 no.1
    • /
    • pp.1-18
    • /
    • 1983
  • Sum of daily mean temperature, sum of daily mean relative humidity and sum of daily mean duration of sunshine during the growing season (March-October), and daily mean temperature, daily mean relative humidity and daily mean minimum temperature during the dormant season (November-February) were obtained respectively from the climactic data recorded at 26 different standard stations for 30 years from 1951 to 1980, to provide a method for proper selection of tree species suitable to a certain site. They were also marked on the map of Korea. The whole country was divided into 6 regions by trend of temperature variation and the regression equations for each region were produced to estimate the sum of daily mean temperature of the growing season and the sum of daily mean minimum temperature of the dormant season in a certain site where tree plantings are planned. The natural range of distribution of each species was expressed by the sum of daily mean temperature and daily mean minimum temperature on the basis of "Horizontal and vertical distribution of the Korean woody plants" reported by Chung and Lee (1965).

  • PDF

Study for Selection of Replica Stone of the Stele for Buddhist Monk Wonjong at Yeoju Godalsa Temple Site using Magnetic Susceptibility (전암대자율을 이용한 여주 고달사지 원종대사탑비 비신의 복제용 석재 선정 연구)

  • Lee, Myeong Seong;Chun, Yu Gun;Kim, Jiyoung
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.299-310
    • /
    • 2016
  • The Stele for Buddhist Monk Wonjong at Godalsa Temple Site was destroyed a long time ago. Only the tortoise-shaped pedestal and the ornamental capstone in the form of a hornless dragon remain at the site and the broken stele body is stored at the National Museum of Korea today. The stele is made of two kinds of rocks that are coarse-grained biotite granite for the pedestal and the capstone, and fine-grained biotite granite including hornblende assemblages and feldspar phenocrysts for the stele body. The coarse-grained biotite granite of the pedestal and capstone showed same magnetic susceptibility and lithological characteristics with biotite granite outcrops in Yeoju area, whereas the fine-grained granite of the stele body did not. To find a provenance of the stele body stone, we investigated Korean granites in terms of magnetic susceptibility, lithology and old recordings about construction process of the stele. As a result, Haeju granite is the most likely to be a cognate rock of the stele body stone as it has same texture and lithological characteristics like color, hornblende assemblages, mineral composition and magnetic susceptibility. It is imported from Haeju (North Korea) to South Korea via China commercially, and the most suitable for a replica stone of the stele body.

Comparison of Two Methods for Estimating the Appearance Probability of Seawater Temperature Difference for the Development of Ocean Thermal Energy (해양온도차에너지 개발을 위한 해수온도차 출현확률 산정 방법 비교)

  • Yoon, Dong-Young;Choi, Hyun-Woo;Lee, Kwang-Soo;Park, Jin-Soon;Kim, Kye-Hyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.2
    • /
    • pp.94-106
    • /
    • 2010
  • Understanding of the amount of energy resources and site selection are required prior to develop Ocean Thermal Energy (OTE). It is necessary to calculate the appearance probability of difference of seawater temperature(${\Delta}T$) between sea surface layer and underwater layers. This research mainly aimed to calculate the appearance probability of ${\Delta}T$ using frequency analysis(FA) and harmonic analysis(HA), and compare the advantages and weaknesses of those methods which has used in the South Sea of Korea. Spatial scale for comparison of two methods was divided into local and global scales related to the estimation of energy resources amount and site selection. In global scale, the Probability Differences(PD) of calculated ${\Delta}T$ from using both methods were created as spatial distribution maps, and compared areas of PD. In local scale, both methods were compared with not only the results of PD at the region of highest probability but also bimonthly probabilities in the regions of highest and lowest PD. Basically, the strong relationship(pearson r=0.96, ${\alpha}$=0.05) between probabilities of two methods showed the usefulness of both methods. In global scale, the area of PD more than 10% was less than 5% of the whole area, which means both methods can be applied to estimate the amount of OTE resources. However, in practice, HA method was considered as a more pragmatic method due to its capability of calculating under various ${\Delta}T$ conditions. In local scale, there was no significant difference between the high probability areas by both methods, showing difference under 5%. However, while FA could detect the whole range of probability, HA had a disadvantage of inability of detecting probability less than 10%. Therefore it was analyzed that the HA is more suitable to estimate the amount of energy resources, and FA is more suitable to select the site for OTE development.

A Study on the Selection Method of Foundation Type in the Underground Parking Lot of Apartments (공동주택 지하 주차장 기초형식 선정방법에 관한 연구)

  • Im, Nam-Gi;Lee, Yeong-Do;Bae, Yong-Hwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.109-116
    • /
    • 2004
  • Normally easy task of plat in urban architecture is that using underground full of activities for increase building site efficiency. Especially for using underground space for the parking lot. Also utilize underground is more increase for fulfill requirement in modern society considered with environmental friendly architecture. The primary objective of this study is to apply analyzed formal foundation type for selecting the optimum type of parking lots considered with structural stability, economical efficiency, construction efficiency, construction duration. This study aim to on criteria decided through the questionaries for the selection considered with in the scale of second stories parking lots underground, parking volume is 80 and reinforced concrete structure. The bearing capacity is 6~8m and downward from surface, healthy ground bearing capacity is 40 t/m2. This study comparative analysis and discuss economical efficiency, construction efficiency, construction duration based constructivist stability which applied Single foundation, Mat foundation, Drop Mat foundation. The result of this study is as follows: First, the result of economical efficiency is that on the basis of single foundation, Drop Mat foundation is 1.88, Mat foundation 2.04 as a comparative analysis on the basis of total construction cost included material cost, labor coast and machinery cost. Second, the result of construction efficiency order is single foundation, Drop Mat foundation, Mat foundation as a comparative analysis on the based connected characteristics. Third, the result of construction duration is that on the basis of Mat Foundation, Drop Mat foundation is 1.33, single foundation is 1.87 as a comparative analysis Critical Path. Forth, Each foundational type characteristics order through the matrix method is that overall each formal type of foundation contraries at economical efficiency and construction efficiency, construction duration. Also expect contradiction between engineers and owners due to engineer pursuit construction duration and ewer to begin with economical efficiency. Fifth, The selection of suitable foundation formal type needs that based consider project characteristic and field condition as according to above result of a comparative analysis. As a result, a comparative analysis economical efficiency, construction efficiency, construction duration of Mat foundation, Drop Mat foundation, single foundation with 3Bay reinforced structure underground parking lots on the healthy ground.

Studies on the Selection of Standard Revegetation Measures on the Highway Cut-slopes (고속도로(高速道路) 절개(切開)비탈면에서 녹화공법(綠化工法) 선정기준(選定基準) 설정(設定)에 관(關)한 연구(硏究))

  • Woo, Bo-Myeong;Kim, Kyung-Hoon
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.4
    • /
    • pp.476-488
    • /
    • 1997
  • The purpose of this study was to figure out the suitable field standards for revegetation measures on cut-slopes in consideration of the environmental factors. The field survey was conducted from 1995 to 1996 on highway cut-slopes. The results obtained could be summarized as follows; The major revegetation measures surveyed were 5 major measures as a whole in descending order of seed-spraying measures, block-sod pitching measures, latticed block pitching measures, hydro-seeding measures with seed-fertilizer-soil materials, and several netting measures on highway cut-slopes. According to the analysis of the environmental factors, the plant coverage was affected several major environmental factors which were soil factors(soil hardness, soil texture, soil and rock condition), and site factors(slope gradient, slope length). From a viewpoint of optimum selection, the major 3 factors(soil factors, slope gradient factors, slope length factors) should be considered for selection of revegetation measures on highway cut-slopes.

  • PDF

Experimental Study on Development for Separation and Reinforcement Geotextiles with Horizontal Wicking Drain Property (수평방향의 위킹 배수 특성을 지닌 분리·보강용 지오텍스타일 개발을 위한 실험적 연구)

  • Kim, Hong-Kwan;Ahn, Min-Soo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.215-224
    • /
    • 2019
  • According to the recent civil engineering construction work site which is a complex process, development of multi-functional geotextiles is required. In this study, the characteristics of five different modified cross-section fiber yarns for the selection of wicking yarns were analyzed and yarns that can achieve target properties were selected. Experimental prototype geotextiles suitable for horizontal wicking drain property and reinforcement was developed and its tensile strength, 2% secant modulus, vertical water permeability, AOS, friction characteristics by the direct shear method, and vertical/horizontal wicking test were analyzed. These tests are conducted to verify the performance of the geotextiles with horizontal wick drain property, separation and reinforcement developed in this study. As a results of the indoor soil box test, it was confirmed that the geotextiles using the wicking yarn sufficiently exhibited the function of discharging excess pore water in the horizontal direction.

Analysis on Siting Strategy for Offshore Wind Farm Based on National Wind Map and GIS (국가바람지도 및 지리정보시스템 기반의 해상풍력단지 입지전략 연구)

  • Kim, Hyun-Goo;Song, Kyu-Bong;Hwang, Sun-Young;Yun, Jin-Ho;Hwang, Hyo-Jeong
    • Journal of Environmental Science International
    • /
    • v.18 no.8
    • /
    • pp.877-883
    • /
    • 2009
  • This study has analyzed the scale, location, resource potential and feasibility of offshore wind farm scientifically and systematically based on the national wind map and GIS. For long-term wind power development, this study pursues siting strategy building, selection of target area and deciding development priority as well as the presenting a basis for assessment that are necessary for policy decision making by making theme layers under GIS environment. According to the analysis after organizing technological development by stages, even if only the most suitable sites are developed among the area of offshore wind farm candidates that can be developed under the current technological standard, it has been evaluated as being able to develop about 3 times of the wind power dissemination target until 2012. It is expected that about 5% of territorial water area can be developed in a short-term future while the southern offshore area possessing relatively favorable wind resource than the western offshore has been identified as the most feasible site. While about 23% of territorial water area has been classified as potential area for offshore wind farm development in a long-term future, even Jeju Island and offshore of Ulsan possessing excellent wind resource have been analyzed as feasible sites. The feasibility assessment of offshore wind lam development established by this study is expected to assist national strategy building for accomplishing the wind power dissemination target.

Development of modernizing Old Small-Hydropower system with custom-built at Overseas (해외 노후 수력발전시스템 수용가 맞춤형 현대화 기술개발 및 실증)

  • Kim, Woonhak;Kang, Seokwon;Shin, Giseok
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.174-181
    • /
    • 2018
  • Purpose: The purpose of this study is to develop and demonstrate the customized modernization technology of the old aged hydropower generation system in operation Method: The modernization design was carried out based on the daily, weekly, monthly, and yearly information of the power plant in operation at the site. Results: In this paper, a safety diagnosis of existing facilities located in the Philippiness was carried out in accordance with the Special Act on the Safety Management of Domestic Facilities, and a method for reinforcing the facilities was selected. Conclusion: The selection of wheel suitable for the local environment and the maintenance of the old facilities were designed by domestic repair/reinforcement technology.