• Title/Summary/Keyword: Suitable Illuminance

Search Result 35, Processing Time 0.04 seconds

Model on the Suitable Illuminance at Urban Neighborhood Park (도시근린공원의 적정조도모형)

  • 최연철;김진선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.3
    • /
    • pp.29-37
    • /
    • 2001
  • The purpose of this study is to determine the suitable illuminance model of an urban neighborhood park. To this end, 1 dependent variable and 11 independent variables were set, and multiple regression analysis was applied to find correlation between variables and the model. The results of this study are as follows; 1) Among 11 independent variables abstracted to study suitable illuminance model of an urban neighborhood park, as a result of analysis on correlation between suitable illuminance of a dependent variable and activity space by using dummy variables, activity type and illuminance by spaces the suitable illuminance required for an urban neighborhood park was much influenced by activity type, and the fact that the activity was not limited to a specific space. 2) As a result of multiple regression analysis, independent variables influencing the suitable illuminance model of an urban neighborhood park were activity space, illuminance by spaces, seated activity, standing activity, and sporting activity. And, for relative contribution of independent variables to suitable illuminance, activity with sporting showed an importance 22 times higher than seated activity. When the central square(Sp_1) of activity spaces was set to reference category using dummy variables, it showed a contribution 52 times higher than sorting space(Sp_7) and the central square as the most important variable. 3) It was analyzed that suitable illuminance of an urban neighborhood part was most influenced by sporting activity but the relative contribution of a sporting space where activity with sporting occurs was least in view of the function of the space. Very high illuminance is required to accept high activity, and if illuminance at a certain space becomes too high, it may influence the illuminance of other spaces, and may consequently have a negative effect on the suitable illuminance of an urban neighborhood park. The results of this study were mainly for teenagers and young adults in their twenties, so further concrete studies which consider gender and a wider age range are needed in the future. Based on subsequent study, suitable illuminance by spaces shall be suggested.

  • PDF

A Study on Suitable Illuminance by Spaces in Urban Parks (도시공원의 공간별 적정조도)

  • Kim Jin-Seon;Choi Yeon-Chul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.5
    • /
    • pp.23-34
    • /
    • 2004
  • In this study, 1 dependent variable and 9 independent variables were established to examine suitable illuminance by spaces in urban parks in consideration of night users' psychological reactions and activity types. Such fixed variables were evaluated by a series of experiments of changing illuminance, and correlation among those variables was verified by correlation analysis and multiple regression analysis to suggest suitable illuminance by spaces. The results of this study are as follows: 1) The independent variables influencing suitable illuminance by spaces in urban parks were directly influenced rather by the psychological reaction of night users than the activity types by spatial functions. 2) Securing suitable illuminance by spaces commonly increased spatial availability, created certain atmosphere, and provided safety in the psychological reaction of night users. 3) Suitable illuminance by spaces in urban parks is: Central square is 31.88lx, resting space 6.30lx, exercising space 33.14lx, children's playground 14.19lx, pedestrian road 12.29lx, entry space 16.30lx, and green space 7.03lx. That is, when a place had more positive activities, spatial illuminance was increased. 4) Though comparison by spaces with the illuminance standard for urban parks as mentioned in KS A 3011-1993 can not be made, such illuminance was relatively compatible with the permissible range of illuminance in the author's opinion. It is expected that this study investigating suitable illuminance by spaces for night use in urban parks, will provide necessary knowledge for securing suitable illuminance by spaces in urban parks through classifyingin detail the illuminance standard of KS A 3011-1993. Besides, by helping make us aware of the importance of illuminance in urban parks as well as of external space in the night, this study will contribute to academic research and development in the field of landscape architecture and associated fields and be utilized in establishing legal and institutional standards.

Development of the Program Road lighting Road Surface Property Measuring Apparatus (도로조명용 프로그램과 노면특성 장치의 개발)

  • ;金紀勳
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.133-133
    • /
    • 1999
  • Average illuminance and luminance can be calculated by graphical methods to a certain extent but to calculate for a wide place a suitable software is needed. Softwares suitable for this purpose have been already developed in foreign nations, but the appropriate softwares for domestic use have not been developed. Therefore a program is developed which is executable in Hangul Windows. The softwares LAPRoad, is developed to calculate luminance and illuminance distribution of road surface, as well as average luminance and illuminance, overall uniformity, longitudinal uniformity, threshold increment veilling luminance and glare. And an apparatus that measures road surface reflection properties is developed. Because the road surface reflection properties is very important in luminance calculation, then concrete road surface reflection properties were measured.

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities (정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가)

  • Choi, Su-Hyun;Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

Daylighting Performance of Lightpipe under Different Sky Conditions (천공상태에 따른 수직형 광파이프 시스템의 채광성능 평가)

  • Kong, Hyo Joo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.101-106
    • /
    • 2008
  • The use of daylighting has been increased recently due to energy and visual comfort. The aims of interior daylighting are to adequately illuminate visual tasks, to create an attractive visual environment, and to save electrical energy. Lightpipe can improve the distribution of light to interior spaces. This study aims to evaluate the comparative daylighting performance of lightpipe under different sky conditions with mock-up model, sized $6m{\times}6m{\times}4m$ ($w{\times}d{\times}h$). For the purpose, perpendicular lightpipe system was designed as 650 diameter, with an aspect ratio of 2. Totally 49 measuring points of and two of outdoor illuminance on the horizontal plane were monitored from 09:00 to 18:30 on April 29 and May 15 2008. Agilent data logger and photometric sensor were used. Light factor were used to analyse daylight performance under different sky condition. Under overcast sky condition and clear sky condition, the lightpipe system is suitable for KS recommendation level of illuminance.

A Study on the Comparison of the Illuminance Values from Lighting Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (조명시뮬레이션의 적절한 사용을 위한 Mock-up 실험 측정값과 주광 시뮬레이션 결과값 비교에 관한 연구)

  • Lim, Ji-Sun;Jun, Byung-Kuk;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.17-20
    • /
    • 2009
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architecture design has need of daylight prediction for reflection efficiently daylight. But it is difficult to predict the illuminance values in daylight system. Using various lighting simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, RELUX 2007, RADIANCE 3.9) and Mock-up experiment with the same space and parameter of daylight (location of space and window, date, time and sky condition).

  • PDF

The Actual State and Evaluation of Artificial Lighting on Coffee Houses Using Study Place around University (학습공간으로 이용되는 대학주변 커피전문점의 조명 실태 및 평가)

  • Choe, Sol-ji;Choi, Yoon-Jung
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.53-62
    • /
    • 2011
  • This study aimed at suggesting improvement of lighting environment of the coffee house using study place. To this end, a series of field investigation was conducted in four possible target coffee houses around university. The field measurement included measurement of general illuminance and tabletop illuminance, observing illumination condition, and status of artificial lighting. Also, on-site questionnaire survey was administrated to 80 users of field measurement targets about using characteristics of coffee house and user's subjective response on light environment. The results are summarized as follows: (1) According to questionnaire survey, most of users checked 'learning (study and reading)' in 'purpose of coffee house using', and 'slightly dark' was checked most in each subjective response (brightness on general space and on tabletop at daytime/night); (2) as results of measurements on general illuminance and on tabletop illuminance during daytime, only one coffee house was suitable for standard; (3) as results of measurements on illuminance during night, all target coffee houses were not met the standard; (4) as results of uniformity ratios, almost uniformities of general illuminance were not met the standard except one case. The common problems of lighting environment of coffee house were analyzed as lack of daylight illumination e.g. having low amount of sunshine from skylight, un-uniformity of insolation by floor plan and absence of window blind, and un-uniformity of artificial luminous intensity e.g. lack of the number or brightness of artificial lighting, using the indirect lighting, using only local lighting, and non-uniform arrangement of artificial lighting.

Visual Performance Evaluation Study of a Scaled Light-Shelf Model (축소모형을 이용한 광선반의 시환경 특성 평가 연구)

  • Cho, Yil-Sik;Kim, Byoung-Soo;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

A Study on the Comparison of the Illuminance Values from Daylight Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (적합한 조명시뮬레이션 사용을 위한 주광 시뮬레이션과 Mock-up 실험 비교에 관한 연구)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2010
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architectural design has a need for daylight prediction. But it is difficult to predict the illuminance values in daylight system. Using various Daylight simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, Relux 2007, Radiance 3.9) and Mock-up experiment with a same space and parameter of daylight (location of space and window, date, time and sky condition).

The Effect of Illuminance and Color Temperature of LED Lighting on Occupants' Perception and HRV

  • Seo, Han Suk;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose: It is crucially important that indoor luminous conditions of built environments be carefully studied so as to promote comfort and occupants' well-being. Method: The current study therefore focuses on the lit aspect of an enclosed space considered to be a resting room ($4.5m{\times}6.32m{\times}2.5m$). Particularly, on the effect that light levels and light color temperatures have on the physiological and psychological responses of resting occupants. To do so, a questionnaire survey was carried out on 50 subjects. The independent variables for the experiment included 9 different luminous environment conditions setup using 3 different levels of illuminance (50 lx, 150 lx, 300 lx) and 3 different color temperatures (2000 K, 3800 K, 5600 K). A questionnaire was utilized in determining which conditions were preferred by occupants. Result: As it turns out, indoor luminous environment designed for relaxation purposes should display luminance levels of at least 150 lx and 3800 K of color temperature in order to provide a visually comfortable environment suitable for the occupant's relaxation while at the same time promoting the psychological and HRV well-being of resting occupants.