Concentration Rise of Fine Particle according to Resuspended Dust from Paved Roads after Sudden Heavy Rain in Busan (부산 도심지역 기습 폭우 후 형성된 도로면 토사의 재비산에 의한 미세먼지 농도 상승)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.25 no.5
    • /
    • pp.705-713
    • /
    • 2016
  • This study investigates the concentration sudden rise in fine particle according to resuspended dust from paved roads after sudden heavy rain in Busan on August 25, 2015. The localized torrential rainfall in Busan area occurred as tropical airmass flow from the south and polar airmass flow from north merged. Orographic effect of Mt. Geumjeong enforced rainfall and it amounted to maximum 80 mm/hr at Dongrae and Geumjeong region in Busan. This heavy rain induced flood and landslide in Busan and the nearby areas. The sudden heavy rain moved soil and gravel from mountainous region, which deposited on paved roads and near roadside. These matters on road suspended by an automobile transit, and increased fine particle concentration of air. In addition outdoor fine particle of high concentration flowed in indoor by shoes, cloths and air circulation.

Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump (펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰)

  • Heo, Min Woong;Min, Ji Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.1
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

Internal pressure in a low-rise building with existing envelope openings and sudden breaching

  • Tecle, Amanuel S.;Bitsuamlak, Girma T.;Aly, Aly Mousaad
    • Wind and Structures
    • /
    • v.16 no.1
    • /
    • pp.25-46
    • /
    • 2013
  • This paper presents a boundary-layer wind tunnel (BLWT) study on the effect of variable dominant openings on steady and transient responses of wind-induced internal pressure in a low-rise building. The paper presents a parametric study focusing on differences and similarities between transient and steady-state responses, the effects of size and locations of dominant openings and vent openings, and the effects of wind angle of attack. In addition, the necessity of internal volume correction during sudden breaching, i.e., a transient response experiment was investigated. A comparison of the BLWT data with ASCE 7-2010, as well as with limited large-scale data obtained at a 'Wall of Wind' facility, is presented.

램제트 연소기의 보염기 장착에 따른 연소기 특성 변화에 대한 수치적 연구

  • Kim, Seong-Don;Jeong, In-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.455-456
    • /
    • 2008
  • A numerical study was conducted on the effect of flame holder which could be added to the inlet duct of Integral Rocket-Ramjet. Two different types of flame holder installations, flame holder without sudden expansion region and flame holder with small sudden expansion region, were compared and showed different flame shapes and pressure rise in the combustor.

  • PDF

Effect of rapid rise in suffering rescue activity on cortisol and human symptom (수난 구조 활동에서의 급상승이 코르티솔 및 인체증상에 미치는 영향)

  • Jeon, Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.99-104
    • /
    • 2022
  • This study was to analyze the effects of sudden rise in cortisol and human symptoms in the situation of rescue at river, The experimental results are as follows. The subjects were A, B, C, and the values of cortisol elevation before and after diving were 6.30ug/dl, 6.50ug/dl, and 6.57ug/dl, respectively. However, in the subject D, the elevation of cortisol before and after diving was significantly elevated to 11.00ug/dl. The reason for this is thought to be the depletion of physical strength through weighty due to the inferiority of the underwater view and tense during the sudden rise. The subjects E showed significantly lower cortisol elevation before and after diving, as 4.28ug/dl, because the age of E was the youngest of the subjects and the anxiety was low due to abundant experience of deep sea diving. Fatigue is 7 to 8, anxiety is 7 to 9, Both showed high values. Psychological strain increased fatigue in underwater search, and poor visual field seemed to increase anxiety. The research results will be provided as empirical data on the safe underwater search activities of rescuers.

Numerical Study on the Coaxial Ramjet Combustor with a Flame Holder (램제트 연소기의 보염기 장착에 따른 연소기 특성 변화에 대한 수치적 연구)

  • Kim, Sung-Don;Jeung, In-Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.114-117
    • /
    • 2007
  • In IRR(Integral Rocket-Ramjet), the booster is integrated into the ramjet combustor. Such combustors do not contain combustor liners or flame holders within the combustor due to the limited volume and flame stabilization depends on the recirculation zones formed by the sudden expansion region between the inlet duct and the combustor. A numerical study was conducted on the effect of flame holder which could be added to the inlet duct of IRR. Two different types of flame holder installations, flame holder without sudden expansion region and flame holder with small sudden expansion region, were compared and showed different flame shapes and pressure rise in the combustor.

  • PDF

Design of Energy Absorption Device Using the Axial Crushing Behavior of Truncated Cone Type Cylinder (콘 형상 실린더의 축 방향 압축변형을 이용한 충격흡수장치 설계)

  • 김지철;이학렬;김일수;심우전;박동화
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.259-267
    • /
    • 2003
  • A brake device for the high-speed impacting object is designed using an axial crushing of thin-walled metal cylinder. Thickness of the cylinder is increased smoothly from the impacting end to the fixed end, resulting in the truncated cone shape. Truncated cone shape minimizes the imperfection-sensitivity of the structure and ensures that plastic hinges are formed sequentially from impacting end. This prevents the undesirable sudden rise in the first peak-crushing load. Several specimens with different conic angles, mean thickness of the wall, and materials were designed and quasi-static compression tests were performed on them. Results indicate that adoption of appropriate conic angle prevents simultaneous wrinkles generation and sudden rise of crushing load and that appropriate conic angle differs in each case, depending on the geometry and material property of the cylinder. Finite element analysis was performed for static compression of the cylinder and its accuracy was checked for the future application.

Sudden rise of fine particle concentration after Typhoon USAGI and NARI passage in Busan (태풍 우사기와 나리 통과 후 부산지역 미세먼지 농도의 급상승에 관한 연구)

  • Jeon, Byung-Il
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.557-564
    • /
    • 2011
  • This study was conducted to investigate the sudden rise of fine particle concentration after the passage of typhoon USAGI and NARI in Busan. Nocturnal inversion layer was formed at atmospheric boundary layer and wind direction changed from southerly wind to northeasterly wind after USAGI passed through Busan. Fine particle concentration in Busan rapidly increased by subsidence of air pollutants released from sources and dust transported from in the vicinity of industrial regions. Wind direction changed from northeasterly wind to southeasterly wind, wind velocity increased and lower atmosphere became extremely unstable after NARI passed through Busan. $PM_{10}$ concentration of Busan increased sharply because of surface dust dispersed by strong wind. Fine particle concentration generally decreases by precipitation and wind after typhoon passes through. However, the concentration can also go up not only by subsidence and transportation in nocturnal inversion layer but also by surface dust which temporarily occurs by strong wind.

Implementation of Occupant Density and Walking Pattern Measurement for Emergency Evacuation and Safety in High-Rise Multi-Purpose Facilities

  • Lee, Myung Sik
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.409-415
    • /
    • 2018
  • Recently, many countries around the world began to show interest in safety against terrorism, fire, and natural disasters. This study aimed to propose a quantitative measurement system for emergency evacuation and safety for various kinds of terrorism and fire within high-rise multi-purpose facilities, which can measure the pedestrians' ordinary walking patterns in the concourse with the highest pedestrian volume out of all the spaces within multi-story buildings, predict pedestrians' evacuation walking lines when a sudden disaster breaks out, and analyze the gait coefficient, occupant density, and evacuation behavior time.