• Title/Summary/Keyword: Suction well

Search Result 186, Processing Time 0.026 seconds

Computational Performance Prediction of Main Coolant Pump for the Integral Reactor SMART (일체형원자로 SMART 냉각재 순환펌프의 전산성능예측)

  • Kim M. H;Lee J. S;Park J. S;Kim J. I;Kim K. K
    • Journal of computational fluids engineering
    • /
    • v.8 no.3
    • /
    • pp.32-40
    • /
    • 2003
  • CFD analyses of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump including suction and discharge parts are presented and compared with experimental data. The purpose of the current study is to validate the CFD method for the performance analysis of the main coolant pump for SMART and to investigate the effect of suction and discharge shapes on the pump performance. To generate a performance curve, not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicts the experimental head value. In the range of the higher flow rates, the results are also in very good agreement with the experimental data, in magnitude but also in terms of slope of variation. For lower flow rates, the results shows that the analysis considering the suction and discharge well describe the typical S-shape performance curve of the axial pump.

The Effects of Suction Care Self Video-based Debriefing-assisted Learning in the Fundamentals of Nursing Practice (자가동영상을 활용한 디브리핑 학습의 효과: 흡인간호 실습교육을 중심으로)

  • Kim, Hyun-Ju
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.22 no.1
    • /
    • pp.88-97
    • /
    • 2015
  • Purpose: This study was conducted to identify the effects of a suction care self video-based debriefing-assisted learning in the fundamentals of nursing practice for nursing students on clinical performance, self-efficacy and problem-solving process. Methods: A nonequivalent control group non-synchronized design study was used and included 97 junior nursing students at P University as participants, 48 of whom were assigned to the experimental group, and 49 of whom were assigned to the control group. The outcome measurements were clinical performance for suction care, self-efficacy, and the problem-solving process. Results: The scores of clinical performance were 23.75 in the experimental group who used the materials and 21.55 in the control group, and the difference was statistically significant (p<.000). Self-efficacy was 4.30 in the experimental group and 4.18 in the control group, which was a statistically significant difference (p=.000), and the pre-to-post differences of self-efficacy was statistically significant as well (p<.001). However, there were no significant differences in the pre-to-post differences of the problem-solving process (p<.802). Conclusions: Self video-based debriefing-assisted learning may be more effective in enhancing clinical performance and self-efficacy than that of conventional practice. Whether self-efficacy will contribute to enhanced learning motivation for nursing students needs further examination.

Safety Evaluation of the Combined Load for Offshore Wind Turbine Suction Foundation Installed on Sandy Soil (사질토 지반에 위치한 해상풍력발전기 석션기초의 복합하중에 대한 안전성 평가)

  • Park, Jeong Seon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.33 no.5
    • /
    • pp.195-202
    • /
    • 2021
  • Offshore wind turbine (OWT) receive a combined vertical-horizontal- moment load by wind, waves, and the structure's own weight. In this study, the bearing capacity for the combined load of the suction foundation of OWT installed on the sandy soil was calculated by finite element analysis. In addition, the stress state of the soil around the suction foundation was analyzed in detail under the condition that a combined load was applied. Based on the results of the analyses, new equations are proposed to calculate the horizontal and moment bearing capacities as well as to define the capacity envelopes under general combined loads.

Design for Installation of Suction Piles in Sand Deposits for Mooring of Floating Offshore Structures (부유식 해상구조물의 계류를 위한 사질토 지반의 석션파일 설계)

  • Park, Chul-Soo;Lee, Ju-Hyung;Baek, Du-Hyun;Do, Jin-Ung
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.10
    • /
    • pp.33-44
    • /
    • 2014
  • The preliminary design of suction pile as the supporting system for concrete floating structures was performed for the pilot project of the southwest coast area in Korea. Prior to starting design work, site conditions of the area including ground and hydraulic conditions, and a 100-year return period external force were throughly evaluated. The suction pile for mooring of the offshore floating structures has to satisfy the lateral resistance against external force as well as the penetration ability according to the soil conditions such as soil types, shear strengths, effective stresses, and seepage forces. In the design, the required penetration depths, which were stable for lateral resistance, were evaluated with the diameters of cylindrical suction pile as the final installing ones. And the design suction pressures at each penetrating depths, at which sand boiling did not occur, were assessed through the comparison of penetration and penetrationresistance forces. As a result, it was impossible for suction piles with the diameter range of 3.0~5.0 m to penetrate into required penetration depths. On the other hand, suction piles with the diameter range of 6.0 m and 7.0 m satisfied both the horizontal stability and the penetration ability by design suction pressures at the required penetration depths of 8.5 m and 8.0 m, respectively.

A Study on the Contamination of Solution with Suction used in Tracheostomy Patients (기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구)

  • Lim Yun-Hee;Yu Kwang Soo
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF

Effects of inlet shape on the performance of a submerged cargo pump (입구부 형상이 수중 카고 펌프의 성능에 미치는 영향)

  • Kim, Joon-Hyung;Choi, Young-Seok;Lee, Kyoung-Yong;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.44-49
    • /
    • 2007
  • In this paper, effects of inlet shape on the performance of a submerged cargo pump were numerically studied using a commercial CFD code CFX. The inlet shape, especially the gap between pump and suction well, is an important parameter in a point of view of performances of submerged cargo pump due to its effects on the residual and also hydraulic performance of the pump, respectively. To know the optimized gap, the overall performance degradations were calculated with the gap. In addition to that, the flow field through the gap was investigated to explain the effect of velocity non-uniformity on the performance of the pump impeller.

The Study of Blister Caused by Cupping Therapy (부항 시술에 의해 형성된 수포에 관한 고찰)

  • Yun, Hye-Yeon;Kwon, Sun-Oh;Kim, Seung-Tae;Park, Hi-Joon;Hahm, Dae-Hyun;Lee, Hye-Jung
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.141-150
    • /
    • 2011
  • Objectives : The aims of this study were to evaluate a blister caused by cupping. Methods : We searched relevant case reports, survey, and review articles using databases of online bibliography. Results : 1. The fluid in the blister caused by cupping therapy is normal substance by laboratory analysis. The fluid has no signs of infection in the culture, Gram stain, or tissue biopsy 2. In histological finding, the blister caused by cupping therapy is made by dermo-epidermal seperation at subcellular level. Suction blistering was neither inflammatory nor autolysis activation of lysosomal hydrolases. 3. Blistering times directly, related to suction pressure. Suction blister formation time is accelerated in older subjects compared with younger individuals and higher temperature was more susceptable to the blister compared with lower temperature. The flexor aspect of forearm is a easy site for suction blister formation compared with leg and abdominal site. 4. Blister caused by cupping therapy is treated by regular and judicious changes of sterile dressing over several weeks. The vesicles healed well and left no visible scar. Conclusions : Blister caused by cupping therapy is artificially controlled by doctor's therapeutic purpose. Blister is not histologically injurious to health and the blister is a natural concomitant after cupping therapy.

High-precision modeling of uplift capacity of suction caissons using a hybrid computational method

  • Alavi, Amir Hossein;Gandomi, Amir Hossein;Mousavi, Mehdi;Mollahasani, Ali
    • Geomechanics and Engineering
    • /
    • v.2 no.4
    • /
    • pp.253-280
    • /
    • 2010
  • A new prediction model is derived for the uplift capacity of suction caissons using a hybrid method coupling genetic programming (GP) and simulated annealing (SA), called GP/SA. The predictor variables included in the analysis are the aspect ratio of caisson, shear strength of clayey soil, load point of application, load inclination angle, soil permeability, and loading rate. The proposed model is developed based on well established and widely dispersed experimental results gathered from the literature. To verify the applicability of the proposed model, it is employed to estimate the uplift capacity of parts of the test results that are not included in the modeling process. Traditional GP and multiple regression analyses are performed to benchmark the derived model. The external validation of the GP/SA and GP models was further verified using several statistical criteria recommended by researchers. Contributions of the parameters affecting the uplift capacity are evaluated through a sensitivity analysis. A subsequent parametric analysis is carried out and the obtained trends are confirmed with some previous studies. Based on the results, the GP/SA-based solution is effectively capable of estimating the horizontal, vertical and inclined uplift capacity of suction caissons. Furthermore, the GP/SA model provides a better prediction performance than the GP, regression and different models found in the literature. The proposed simplified formulation can reliably be employed for the pre-design of suction caissons. It may be also used as a quick check on solutions developed by more time consuming and in-depth deterministic analyses.

Effect of a Suction Care Education Program on Undergraduate Nursing Students (간호대학생에게 적용한 흡인간호 교육프로그램의 효과)

  • Kim, Hyun-Ju;Kang, So-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1197-1206
    • /
    • 2013
  • The purpose of this study was to develop a suction care education program and to evaluate the effects on clinical performance, self-efficacy, and problem-solving process regarding suction practice. The participants were 96 in second-year nursing students at P university in Pusan, Korea. The data was collected from Oct. 6th toward Oct. 19th, 2011, and analyzed by ${\chi}^2$, t-test, ANCOVA test using SPSS 18.0. The scores of clinical performance were 23.72 in the experimental group who learned this program and 22.16 in the control group, and were statistically significant(p<.001). Self-efficacy were 7.58 in the experimental group and 7.08 in the control group, which was statistically significant(p=.03), and the pre-to-post difference of self-efficacy was statistically significant as well(p<.001). However, there were no significant differences in the problem-solving process(p=.06) and the pre-to-post difference related to this(p=.011). This study showed that clinical performance and self-efficacy were improved by suction care education program.

Measurements of Soil Water Characteristics for Different Unsaturated Soils (불포화토의 함수특성 측정)

  • Kim, Sang-Gyu;Ryu, Ji-Hyeop;Song, Jin-Gyu
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.139-152
    • /
    • 1996
  • In order to treat flow problems for unsaturated soils, it is necessary to obtain the soil-water characteristic curves which show nonlinear relationship between metric suction and volumetric water content. With two different pleasuring devices, measurements of the matric suction were taken for Jumoonjin sand, Hangang sand, and weathered granite soils with different fined. Experimental parameters which can describe experimental formulas for the soil-water characteristics were determined by using the data obtained from the experiment. Among experimental formulas of previous researchers, that of van Genuchten(1980) agreed well with the results of experiments. For weathered granite soils, the parameters increased with the increase of fine contents, Therefore, the soil-water characteristic for a weathered soil can be estimated by using Parameters corresponding to its fine contents.

  • PDF