• Title/Summary/Keyword: Suction well

Search Result 186, Processing Time 0.026 seconds

Design of an Axial-flow Pump Using a Genetic Optimization Technique (유전적 최적화 기법을 이용한 축류 펌프의 설계)

  • Song, Jae-Wook;Oh, Jae-Min;Chung, Myung-Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.795-804
    • /
    • 2002
  • The optimal design code of an axial flow pump has been developed to determine geometric and fluid dynamic variables under hydrodynamic as well as mechanical design constraints. The design code includes the optimization of the complete radial distribution of the geometry by determining the coefficients of 2$^{nd}$ order polynomials to represent the three-dimensional geometry. The optimization problem has been formulated with a nonlinear multivariable objective function, maximizing the efficiency and stall margin, while minimizing the net positive suction head required. Calculation of the objective function is based on the mean streamline analysis and through-flow analysis using the present state-of-the-art model. The optimal solution is calculated using the penalty function method in which the genetic optimizer is employed. The optimized efficiency and design variables are presented in this paper as a function of non-dimensional specific speed in the range, 2$\leq$ $n_{s}$ $\leq$10. The results can be used in preliminary design of axial flow pumps.

Primary Esophageal Repair of Long-gap Esophageal Atresia - Report of One Case - (원간격결손 식도폐쇄증의 일차적 식도복원)

  • Lee, Myung-Duk
    • Advances in pediatric surgery
    • /
    • v.1 no.1
    • /
    • pp.53-58
    • /
    • 1995
  • A delayed primary esophago-esophagostomy of a case of long-gap esophageal atresia without tracheoesophageal fistula was performed in success with three months' intermittent periodic bougienage of the upper pouch via mouth as well as the lower esophagus through Janeway gastrostomy. Meanwhile, an effective continuous sump suction from the upper pouch seemed to be a critical part of the patient management. The extra length of esophagus for primary anastomosis could be achieved by a circular myotomy. Stricture at the myotomy site, found 4 months later, was treated with periodic pneumatic baloon dilations only with temporary symptomatic reliefs. After 4 months' trials, operative esophagoplasty was performed successfully. A careful follow-up schedule for the myotomy site would be required for early detection of stricture. The previous neonatal patient is currently 8 years old, healthy school-boy, and has a normal barium swallow without stricture or gastroesophageal reflux.

  • PDF

Numerical Simulation of Locally-Forced Turbulent Boundary Layer (국소교란에 의한 난류 경계층 유동의 수치해석)

  • Ri, Gwang-Hun;Seong, Hyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.96-107
    • /
    • 2001
  • An unsteady numerical simulation was performed to analyze flow structures behind a local suction/blowing in a flat-plate turbulent boundary layer. The local forcing was given to the boundary layer flow by means of sinusoidally oscillating jet. A version of the unsteady $\kappa$-$\xi$-f(sub)u model (Rhee and Sung 2000) was employed. The Reynolds number based on the momentum thickness was about Re(sub)$\theta$=1700. The forcing frequency was varied in the range 0.011$\leq$f(sup)+$\leq$0.044 with a fixed forcing amplitude A(sub)o=0.4. The predicted results were compared and validated with the experimental data. It was shown that the unsteady locally-forced boundary layer flow is predicted well by the $\kappa$-$\xi$-f(sub)u model. The effect of the pitch angle of local forcing on the reduction of skin friction was also examined.

A Study on the Flow Characteristics of Desktop Personal Computer by In-Out Fan (흡.배기 팬에 의한 Desktop Personal Computer 내부의 유동특성에 관한 연구)

  • Lee, Haeng-Nam;Park, Gil-Moon;Jung, Han-Byul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.665-671
    • /
    • 2007
  • The purpose of this study is to find out a flow characteristics required by the design of a computer case and to provide information about the preliminary data of cooling efficiency of CPU and a flow inside of a case. We examined a flow characteristic-suction a tracing particle occurred from a surge tand installed at an inlet into a computer case and moving it to a exit duct-experimentally by using PIV. The experimental device was consists of a fan inflowing and discharging the air into the computer case and a slot installed with a CPU cooling ran add-on, and analyzed the data of Re-stress distribution, velocity distribution, and kinetic energy distribution. This research will make a great contribution to improvement of the efficiency and performance of notebook, workstation, server, and all the design of electronic devices using large scale integrated(LSI) as well as usual computers.

Shape Optimization of a Stator Blade in a Single-Stage Transonic Axial Compressor (단단 천음속 축류압축기의 정익형상 최적설계)

  • Kim Kwang Yong;Jang Choon Man
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.625-632
    • /
    • 2005
  • This paper describes the shape optimization of a stator blade in a single-stage transonic axial compressor. The blade optimization has been performed using response surface method and three-dimensional Navier-Stokes analysis. Two shape variables of the stator blade, which are used to define a stacking line, are introduced to increase an adiabatic efficiency. Data points for response evaluations have been selected by D-optimal design, and linear programming method has been used for an optimization on a response surface. Throughout the shape optimization of a stator blade, the adiabatic efficiency is increased to 5.8 percent compared to that of the reference shape of the stator. The increase of the efficiency is mainly caused by the pressure enhancement in the stator blade. Flow separation on the blade suction surface of the stator is also improved by optimizing the stator blade. It is noted that the optimization of the stator blade is also useful method to increase the adiabatic efficiency in the axial compressor as well as the optimization of a rotor blade, which is widely used now.

Performance analysis of a hermetic reciprocating compressor using the alternative refrigerants, HFC134a and HC600a (대체냉매(HFC134a, HC600a)용 밀폐형 왕복동 압축기의 성능해석에 관한 연구)

  • Kim, Jeong-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.7
    • /
    • pp.966-979
    • /
    • 1998
  • Thermodynamic and dynamic analysis has been conducted to investigate performance variations induced by substitution of alternative refrigerants, HFC134a or HC600a for CFC12 in hermetic reciprocating compressors. For the thermodynamic analysis, mass and energy conservation laws are applied to the cylinder volume and Helmholtz resonator modeling method is adopted to describe gas pulsations at suction and discharge system. The modeling of the dynamics of the compressor mechanism has been performed with lumped mass method to analyse the bearing loads and friction losses at each bearing. To verify the correctness of this analysis, results of the performance simulation have been compared to those of calorimetric measurrements of compressor operating with CFC12. Analysis of the various losses, noise and reliability as well as performance has been conducted to present the design guideline for the compressor development with alternative refrigerants. It is found that compressors with alternative refrigerants, HFC 134a or HC600a give better COPs than those with CFC12 under the same operating conditions and especially, compressors with HC600a show better reliability and noise characteristics also.

Extensive Tension Pneumocephalus Caused by Spinal Tapping in a Patient with Basal Skull Fracture and Pneumothorax

  • Lee, Seung-Hwan;Koh, Jun-Seok;Bang, Jae-Seung;Kim, Myung-Chun
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.5
    • /
    • pp.318-321
    • /
    • 2009
  • Tension pneumocephalus may follow a cerebrospinal fluid(CSF) leak communicating with extensive extradural air. However, it rarely occurs after diagnostic lumbar puncture, and its treatment and pathophysiology are uncertain. Tension pneumocephalus can develop even after diagnostic lumbar puncture in a special condition. This extremely rare condition and underlying pathophysiology will be presented and discussed. The authors report the case of a 44-year-old man with a basal skull fracture accompanied by pneumothorax necessitating chest tube suction drainage, who underwent an uneventful lumbar tapping that was complicated by postprocedural tension pneumocephalus resulting in an altered mental status. The patient was managed by burr hole trephination and saline infusion following chest tube disengagement. He recovered well with no neurologic deficits after the operation, and a follow-up computed tomography (CT) scan demonstrated that the pneumocephalus had completely resolved. Tension pneumocephalus is a rare but serious complication of lumbar puncture in patients with basal skull fractures accompanied by pneumothorax, which requires continuous chest tube drainage. Thus, when there is a need for lumbar tapping in these patients, it should be performed after the negative pressure is disengaged.

Design and performance analysis of a gerotor expander for power generation from waste heat (폐열회수 발전을 위한 지로터 팽창기 설계 및 성능해석)

  • Park, Keun-Tae;Kim, Yong-Hee;Kim, Hyun-Jin
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.17-25
    • /
    • 2016
  • In this paper, the feasibility study on a gerotor type expander as a power converting device in a small scale power generation ORC system was made by performance analysis of the gerotor expander. Design of a 1kW-class gerotor expander was carried out and its performance was numerically simulated. For a R134a Rankine system with about 20 kW solar heat source, the gerotor expander efficiency was calculated to be 35~75% for the operating conditions of $Te=80{\sim}100^{\circ}C$ and $Tc=30{\sim}60^{\circ}C$. Maximum expander efficiency was obtained at an expansion ratio somewhat higher than the design expansion ratio due to pre-expansion during suction process inside the outer and inner rotor mate. If the operating expansion ratio is not far from the design expansion ratio, the gerotor expander performance can be well compared to that of a scroll type.

The built-in sensor bearing to measure shaft behavior of compressor for air-conditioning (공조용 압축기 축 거동 측정용 베어링 내장형 센서)

  • 김지운;안형준;김지영;한동철;윤정호;황인수
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.230-236
    • /
    • 2001
  • We developed a built-in sensor bearing to measure the rotor motion of a rolling piston type compressor for the air conditioner. Because of needs for the high efficiency and long life span of compressor, and the usage of alternative refrigerants, the operating condition of the compressor becomes more severe. The accurate measurement of the rotor motion of the compressor can contribute greatly to the design and analysis of the hydrodynamic bearing. However, it is difficult to measure accurately the shaft behavior of small compressor because of the small space for the sensor mount, high temperature and pressure of compressor, oil mixed with refrigerant, and electromagnetic noise of the motor. To overcome these difficulties, we develop the cylindrical capacitive sensor that is built in the hydrodynamic bearing and calibrate the built-in sensor bearing indirectly through measuring the oil relative permittivity. We measured the rotor motion as well as suction and discharge pressures in various conditions. The several experimental results show that the developed built-in sensor bearing can measure the rotor motion not only in steady state but also in transient state.

  • PDF

Effects of Air Drain and Confined Conditions to Infiltration Rate in Unsaturated Soils (불포화 토양에서 공기의 배출/제한이 침투속도에 미치는 영향)

  • Kim, Sangrae;Ki, Jaehong;Kim, Youngjin;Han, Mooyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.681-687
    • /
    • 2008
  • It is well known that the water infiltration rate depends on soil properties such as soil water content, water head, capillary suction, density, hydraulic conductivity, and porosity. However, most of proposed infiltration models assume that the air phase is continuous and in equilibrium with the atmosphere or air compression and air entrapment on infiltration was not considered. This study presents experimental results on unsaturated water infiltration to relate air entrapment and hydraulic conductivity function based on soil air properties. The objectives of this study were to measure change of soil air pressure ahead of wetting front under air drain and air confined condition to find the confined air effect on infiltration rate, to reduce the entrapped air volume related with soil air pressure to increase the soil permeability, and to make a basis of infiltration process model for the purpose of improvement of infiltration rate in the homogeneous soil column. The results of the work show that soil air pressure increases according to increasement of the saturated soil depth rather than the wetting front depth during infiltration process.