• Title/Summary/Keyword: Suction Pump

Search Result 209, Processing Time 0.024 seconds

Numerical Analysis on the Effect of Flow Rate Variation in Double-Suction Centrifugal Pump (양흡입 원심펌프에 있어서 유량변화의 영향에 관한 수치해석적 연구)

  • An, Young-Joon;Shin, Byeong-Rog
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.51-56
    • /
    • 2010
  • A numerical simulation is carried out to investigate the effect of flow rate variation and performance characteristics of double-suction centrifugal pump. Two types of pump which have different impeller inlet breadth and curvature of the shroud line consist of six blades impeller and shroud ring. Finite-volume method with structured mesh and $k-\omega$ Shear Stress Transport turbulence model was used to guaranty more accurate prediction of turbulent flow in the pump impeller. Total head, power and overall efficiency were calculated to obtain performance characteristics of two types of pump according to the variation of flow rate. From the results, impeller having smooth curve along the shroud line obtained good performance. The lower flow rate, the more circulation region, flow unsteadiness and complicate flow pattern are observed. Complicated internal flow phenomena through impellers such as flow separation, pressure loss, flow unsteadiness and performance are investigated and discussed.

Investigation on the Flow Field Upstream of a Centrifugal Pump Impeller

  • Zhang, Yao;Luo, Xianwu;Yi, Yunchi;Zhuang, Baotang;Xu, Hongyuan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.209-216
    • /
    • 2011
  • The flow upstream of a centrifugal pump impeller has been investigated by both experimental test and numerical simulation. For experimental study, the flow field at four sections in the pump suction is measured by using PIV method. For calculation, the three dimensional turbulent flow for the full flow passage of the pump is simulated based on RANS equations combined with RNG k-$\varepsilon$ turbulence model. From those results, it is noted that at both design lo ad and quarter load condition, the pre-swirl flow whose direction is the same as the impeller rotation exists at all four sections in suction pipe of the pump, and at each section, the pre-swirl velocity becomes obviously larger at higher rotational speed. It is also indicated that at quarter load condition, the low pressure region at suction surface of the vane is large because of the unfavorable flow upstream of the pump impeller.

Flow Characteristics of a Jet Pump by the Angle Variation of a Suction Pipe (분사펌프의 흡입관 각도 변화에 따른 유동특성)

  • Kim, Noh Hyeong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.61-67
    • /
    • 2016
  • In this study, STAR-CD-based CFD techniques was used to analyze velocity distribution and pressure distribution according to the variation of angels at $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$ a suction pipe when inlet velocity condition is 1 m/s. SIMPLE maritime law used for analytical algorithm and the results of CFD analysis evaluated by particle image velocimetry (PIV). The results of CFD analysis in this study have revealed that the optimal angle of a suction pipe for a jet pump is $90^{\circ}$ and the PIV test has showed the same results. Therefore, it is thought that when CFD is used to analyze the flow characteristics of a jet pump it would be possible to produce optimal designs of its devices.

A study on the flow characteristics around a suction pipe of circulation water pump in thermal power plant (화력발전소 순환수펌프 흡입관 주위에서의 유동특성에 관한 연구)

  • Choi, Sung-Tyong;Ahn, Jung-Hyeon;Moon, Seung-Jae;Lee, Jae-Heon;Yoo, Ho-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.201-204
    • /
    • 2008
  • Vortex and swirl occurring in a pump suction intake sump normally reduce the performance and disturb the safe operation of the circulation water pump in thermal power plants. This paper presents a case study of one particular intake sump design via a CFD analysis and a hydraulic model testing. The physical experiments and numerical analysis were performed under two flow and three level variation conditions. The vortex patterns around the pump suction pipe have been predicted by a commercial CFD code with the k-${\varepsilon}$ model. The model tests were conducted on a 1/10 model for a practical intake sump. The location, number and general pattern of the free surface vortex and submerged vortex predicted by CFD simulation were found to be a good agreement with those observed in the model testing.

  • PDF

Hydraulic design of fuel pump in turbo-pump system and performance evaluation using CFD (터보펌프용 연료펌프의 설계와 CFD를 이용한 성능 평가)

  • Lee, Kyoung-Hoon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.408-416
    • /
    • 2002
  • Hydraulic performance of the pump with an inducer was predicted by 3-D Navier-stokes calculation. The evaluated pump was the single-stage centrifugal pump with a separated inducer to pressurize fuel (LCH4) in Turbo-pump system with a specific speed (Ns) of approximately 0.3[rad/s, m3/s, J/kg] and a suction specific speed(s) of 15[rad/s, m3/s, J/kg]. That conventional pump was designed with the combination of 1-D theory and empirical correlation. In this study, preliminary design to select key parameters such as inlet flow coefficient was reviewed by investigating sets of the known design methods to achieve appropriate suction performance, and the performance of newly designed inducer and impeller was compared with the old one, using CFD method. The numerical results showed that the hydraulic efficiency of the new pump was predicted $5.5\%$ higher than that of the conventional one, through design parameter re-selection, configuration improvement and blade loading control

  • PDF

Effects of inlet shape on the performance of a submerged cargo pump (입구부 형상이 수중 카고 펌프의 성능에 미치는 영향)

  • Kim, Joon-Hyung;Choi, Young-Seok;Lee, Kyoung-Yong;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.44-49
    • /
    • 2007
  • In this paper, effects of inlet shape on the performance of a submerged cargo pump were numerically studied using a commercial CFD code CFX. The inlet shape, especially the gap between pump and suction well, is an important parameter in a point of view of performances of submerged cargo pump due to its effects on the residual and also hydraulic performance of the pump, respectively. To know the optimized gap, the overall performance degradations were calculated with the gap. In addition to that, the flow field through the gap was investigated to explain the effect of velocity non-uniformity on the performance of the pump impeller.

An Experimental Study on the Performance Characteristics of a Heat Pump System in the Heating Operation Mode with the Hot Gas Bypass (열펌프의 난방운전시 핫가스 바이패스에 따른 성능 특성에 관한 실험적 연구)

  • Ahn, Jae-Hwan;Joo, Young-Ju;Cho, Il-Yong;Kang, Hoon;Kim, Yong-Chan;Choi, Jong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.539-543
    • /
    • 2009
  • When the suction pressure of compressor decreases under its limit, the compression ratio is increased causing the malfunctions of compressor. As the method to decrease the compression ratio, hot gas bypass system is usually adopted in heat pump system. In the hot gas bypass system, the discharged gas from the compressor is bypassed into the compressor suction, which causes the increase of suction pressure and the decrease of compression ratio. In this study, the characteristics and performances of the hot gas bypass system in heat pump was investigated experimentally with a variation of the bypass flow rate ratio. With the increase of the bypass rate ratio, the compressor suction pressure was increased, even though the total capacity and COP was decreased. From the analysis of the experimental results, the optimum pressure control algorithm was suggested in this study.

  • PDF

THE PERFORMANCE ANALYSIS OF A CIRCULATING WATER PUMP FOR A NUCLEAR POWER PLANT (원자력 발전소용 순환수 펌프의 성능해석)

  • Lee, M.S.;Han, B.Y.;Hwang, D.Y.;Yoo, S.S.;Park, H.K.
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.69-75
    • /
    • 2009
  • The objective of this study is to investigate the suitable design for a domestic Circulating water pump(CWP), which is used in cooling-water intakes for the unit 3 and 4 of Yeonggwang nuclear power plant. All the simulations are performed, using CFD method with a commercial code STAR-CCM+ version 3.02. After modeling a present design of the pump, the flow around the rotating blade was calculated by using quasi-static method and sliding mesh method with the almost same condition as an actual state. Based on fundamental simulations with various depth of sea water, the reference pressure for the boundary condition of the present study was decided. To verify the reliability of the calculation results, the suction flow rate of the data was compared with that of the experimental data. As a result of this comparison, it is confirmed that two results are fairly consistent. For the improvement of the suction flow rate, computational analysis was done by changing a flow channel and blade shapes. It is shown that the suction flow rate of the new pump was improved.

Structural Controls on Crustal Fluid Redistribution and Hydrothermal Gold Deposits: A Review on the Suction Pump and Fault Valve Models (지각 내 열수 재분배와 금광상 형성의 구조적 제어: 석션 펌프 및 단층 밸브 모델에 대한 리뷰)

  • Kwak, Yujung;Park, Seung-Ik;Park, Changyun
    • Economic and Environmental Geology
    • /
    • v.55 no.2
    • /
    • pp.183-195
    • /
    • 2022
  • Hydrothermal gold deposits are evidence of intensive fluid flow through fault zones, and the resultant vein structures and textures reflect the fluid redistribution mechanism. This review introduces the suction pump and fault valve models as fluid circulation mechanisms causing hydrothermal gold deposits in the frameworks of the concepts of fault mechanics. The suction pump and fault valve models describe faulting-driven heterogeneous fluid flow and related vein formation mechanisms, accompanied by the cycles of (1) stress accumulation and fluid pressure build-up and (2) seismic rupture and stress/fluid pressure release. The models are available under different geological environments (stress conditions), and the vein structures and textures representing the mechanisms have similarities and differences. The suction pump and fault valve models must help better to interpret the origins of hydrothermal gold deposits in Korea and improve the efficiency of further exploration.

Numerical Analysis on Cavitation of Centrifugal Pump (원심펌프의 캐비테이션에 대한 수치해석)

  • Kim, Myung-Jin;Jin, Hyun-Bae;Son, Chang-Ho;Chung, Wui-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.2
    • /
    • pp.27-34
    • /
    • 2013
  • As the operating range of centrifugal pump is expanded recently, the various suction conditions are demanded. The most important problem in the suction conditions is cavitation. In this study, to analyze the characteristics for such the cavitation, first the validity of the numerical analysis was certified through comparison with the experimental result of performance curve according to flow rate for the industrial centrifugal pump. At this time, the transient numerical analysis for the full type model of the centrifugal pump was performed to get more accurate results. The numerical analysis on the cavitation of centrifugal pump were conducted on the two-phase flow as the same method of one-phased flow.