• 제목/요약/키워드: Subway particle

검색결과 65건 처리시간 0.022초

지하철 객실 적용을 위한 황칠 추출물 소독제의 항균특성 및 안전성 평가 (Anti-bacterial properties and safety evaluation of disinfectant using Dendropanax morbifera (Hwangchil) extract for passenger cabin in the subway)

  • 부이칵호앙부;박재석;이영철
    • 한국입자에어로졸학회지
    • /
    • 제18권2호
    • /
    • pp.37-50
    • /
    • 2022
  • Due to the syndrome coronavirus 2 (SARS-CoV-2) pandemic, the subway passenger cabin should be continuously sterilized. However, a disinfectant such as chlorine is toxic and can lead to different issues to human health. In this paper, we introduced a novel disinfectant based on natural product (Dendropanax morbifera extract). Via ultra-high performance liquid chromatography - mass spectrometer (UHPLC-MS), different compounds from Dendropanax morbifera extract showed antivirus potentials. Antimicrobial experiments confirmed that the air-disinfectant containing Dendropanax morbifera can eliminate harmful microorganisms including Gram (-), Gram (+), and yeast within 5 mins. The as-prepared air-disinfectant also showed high antivirus activity against H1N1, HRV, and EV71. Deodorization test also indicates that the as-prepared air-disinfectant can lower the harmful gas such as ammonia and trimethylamine in the atmosphere. To evaluate the potential of air-disinfectant containing Dendropanax morbifera in practical applications, different safety tests including acute oral toxicity, acute skin irritation, and eye irritation were conducted. Results showed that the as-prepared disinfectant did not negatively affect tested animals during these safety investigations.

공기조화기 장착용 축상유입식 싸이클론의 압력손실에 대한 수치해석 및 실험적 연구 (Numerical and experimental study on the pressure dorp of axial-flow cyclone in the air handling unit)

  • 권순박;박덕신;조영민;김세영;김명준;김호중;김태성
    • 한국입자에어로졸학회지
    • /
    • 제5권2호
    • /
    • pp.37-43
    • /
    • 2009
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator are used in the air handling unit (AHU) of subway stations. However, those systems are prone to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts might malfunction due to the high load of particulates unless the filter medium is periodically replaced. In this study, the use of axial-flow cyclone was proposed for particulate filter unit in the AHU for its low operation and maintenance cost. Novel shape of axial-flow cyclone was designed by using computational fluid dynamics (CFD). The shape of vortex vane was optimized in terms of pressure drop and tangential velocity. In addition, CFD analysis was validated experimentally through the pressure drop measurement of mock-up model. We found that pressure drop and tangential velocity of fluid through the axia-flow cyclone was significantly affected by the rotating degree of vortex vane and the numerical prediction of pressure drop agreed well with experimental measurement.

  • PDF

지하역사 승강장 공조 시스템 필터용 항바이러스 코팅 성능 및 재생 성능 평가 (Development of Optimal Antiviral Coating Method for the Air Filtration System of Subway Station)

  • 박대훈;황정호;신동호;김영훈;이건희;박인용;김상복;홍기정;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.9-21
    • /
    • 2022
  • In this study, a novel antiviral coating method for the air filtration system of subway station was investigated. Using dry aerosol coating process, we developed a high-performance antiviral air filter with spark discharger and carbon brush type ionizer. Silver nanoparticles were produced by a spark discharge generation system with ion injection system and were used as antiviral agents coated onto a medium grade air filter. The pressure drop, filtration efficiency, and antiviral ability of the filter against aerosolized MS2 virus particles as a surrogate of SARS-CoV-2 virus were tested with dust contamination. Dust contamination caused the increase of the filtration efficiency and pressure drop, while the antiviral agents (in this study, silver nanoparticles) coating did not have any significant effect on the filtration efficiency and pressure drop. Using these properties, we suggested a novel method to maximize the antiviral performance of the antiviral air filter that was contaminated by dust particles. Moreover theoretical analysis of antiviral ability with dust contamination and re-coated antiviral agents was carried out using a mathematical model to calculate the time-dependent antiviral effect of the filter under actual conditions of subway station. Our model can be used to apply on antiviral air filtration system of subway station for prevention of pandemic diffusion, and predict the life cycle of an antiviral filter.

The Effect of Platform Screen Doors on PM10 Levels in a Subway Station and a Trial to Reduce PM10 in Tunnels

  • Son, Youn-Suk;Salama, Amgad;Jeong, Hye-Seon;Kim, Suhyang;Jeong, Jin-Ho;Lee, Jaihyo;SunWoo, Young;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권1호
    • /
    • pp.38-47
    • /
    • 2013
  • $PM_{10}$ concentrations were measured at four monitoring sites at the Daechaung station of the Seoul subway. The four locations included two tunnels, a platform, and a waiting room. The outside site of the subway was also monitored for comparison purposes. In addition, the effect of the platform screen doors (PSDs) recently installed to isolate the $PM_{10}$ in a platform from a tunnel were evaluated, and a comparison between $PM_{10}$ levels during rush and non-rush hours was performed. It was observed that $PM_{10}$ levels in the tunnels were generally higher than those in the other locations. This might be associated with the generation of $PM_{10}$ within the tunnel due to the train braking and wear of the subway lines with the motion of the trains, which promotes the mixing and suspension of particulate matter. During this tunnel study, it was observed that the particle size of $PM_{10}$ ranged from 1.8 to 5.6 ${\mu}m$. It was revealed that the $PM_{10}$ levels in the tunnels were significantly increased by the PSDs, while those in the platform and waiting room decreased. As a result, in order to estimate the effect of ventilation system on $PM_{10}$ levels in the tunnels, fans with inverters were operated. It was found that the concentration of $PM_{10}$ was below 150 ${\mu}g/m^3$ when the air flow rate into a tunnel was approximately 210,000-216,000 CMH.

부산지역 지하역사의 최근 3년간(2015~2017년) CO, CO2, NO2 농도의 특성 (Characteristics of CO, CO2, and NO2 Concentrations at Subway Stations in Busan for 3 Years (2015~2017))

  • 전병일
    • 한국환경과학회지
    • /
    • 제28권7호
    • /
    • pp.595-606
    • /
    • 2019
  • This research investigated the characteristics of CO, $CO_2$, and $NO_2$ concentrations at main subway stations in Busan. The annual mean CO concentrations at the Suyeong and Nampo stations were 0.75 ppm and 0.48 ppm, respectively. Annual $CO_2$ concentration at the Seomyeon 1- platform was 649 ppm. The $NO_2$ concentrations at the Seomyeon 2- waiting room and the Yeonsan station were 0.048 ppm and 0.037 ppm, respectively. CO concentration was highest at two times of the day, and was proportional to the number of passengers commuting to and from work. The CO and $CO_2$ concentrations were highest in winter, but $NO_2$ concentration was highest in spring. CO and $CO_2$ concentrations were highest on Saturday and lowest on Sunday. The correlation of CO and $NO_2$ concentrations measured at the subway stations with those at the ambient air quality station were highest at the Seomyeon 1 and 2- waiting room and Jeonpodong. The correlation was lowest at the Yeonsan and Yeonsandong station. The number of days when $CO_2$ concentration exceeded 700 ppm over the last three years at the Seomyeon 1- platform was 174. The findings of this research are expected to deepen understanding of the fine particle characteristics at subway stations in Busan and be useful for developing a strategy for controlling urban indoor air quality.

지하역사 기본 모델에 대한 여객 유동 특성 해석 (Analysis of Pedestrian Flow Characteristics in Subway Station)

  • 남성원
    • 한국철도학회논문집
    • /
    • 제9권3호
    • /
    • pp.271-276
    • /
    • 2006
  • Insight into behaviour of pedestrians as welt as tools to assess passenger flow condition is important in such instances as planning and geometric design of railway station under regular and safety-critical circumstances. Algorithm for passenger flow analysis based on DEM (Discrete Element Method) is newly developed. There are lots of similarity between particle-laden two phase flow and passenger flow. The velocity component of 1st phase corresponds to the unit vector of calculation cell, each particle to passenger, volume fraction to population density and the particle velocity to the walking velocity, etc. And, the walking velocity of passenger is also represented by the function of population density. Key algorithms are developed to determine the position of passenger, population density and numbering to each passenger. To verify the effectiveness of new algorithm, passenger flow analysis for the basic models of railway station is conducted.

서울지역 지하철역의 라돈농도 분포 특성 (Distribution of $^{222}Rn$ Concentration in Seoul Subway Stations)

  • 전재식;김덕찬
    • 대한환경공학회지
    • /
    • 제28권6호
    • /
    • pp.588-595
    • /
    • 2006
  • 본 연구는 서울지역 지하철역 실내 공기 중 라돈분포를 조사하여 그 발생원을 추적 확인하기 위하여 수행되었다. 1998년부터 2004년까지 232개 역사를 대상으로 알파비적검출기를 사용하여 실내 공기 중 장기라돈을 측정하였으며 지하수중 라돈농도는 알파입자계수법에 의하여 측정하였다. 라돈의 주 발생원을 추적하기 위하여 8개 역사를 선정하여 각 역사의 승강장과 인접터널에 대한 공기 중 라돈농도를 조사하였다. 전체역사에 대한 라돈농도 분석결과 기하평균 및 산술평균은 각각 $1.40{\pm}1.94pCi/L,\;1.65{\pm}1.07$였으며, 승강장과 매표소의 기하평균은 각각 $1.54{\pm}1.96pCi/L,\;1.23{\pm}1.88pCi/L$로 승강장에서의 라돈농도가 매표소의 농도보다 더 높게 나타났다. 지질구조와 지하역사의 라돈분포는 밀접한 상관성을 보였으며 터널내부와 지하수중의 라돈농도는 역사 승강장의 라돈농도에 크게 영향을 미치고 있었다. 또한 역사의 승강장이 위치하고 있는 깊이 정도에 따라 라돈농도의 차이를 보였다(p<0.05).

바이브로 해머 및 RCD 공법 적용시 기존터널에 미치는 진동영향해석 (A study on the effect of ground vibration induced by vibrohammer and RCD on adjacent subway tunnel)

  • 허영;남기천;김태형;방진호;곽창원
    • 한국터널지하공간학회 논문집
    • /
    • 제5권2호
    • /
    • pp.135-146
    • /
    • 2003
  • 본 논문에서는 교량 기초를 위한 널말뚝 압입과 RCD 말뚝 시공시에 발생하는 진동에 대한 기존 지하철 구조물의 안정성을 유한차분법에 의한 동적수치해석을 이용하여 고찰하였다. 먼저 진동에 의한 구조물의 안정성 평가 기준을 국내외 사례를 토대로 제안하고 바이브로 해머의 제원과 하중제안식을 바탕으로 수치해석을 수행하여 널말뚝 압입시 발생하는 최대입자속도를 산정하였다. 아울러 RCD 말뚝 시공시 비트진동에 의한 토체의 진동속도를 실측치와 경험식을 이용하여 산정하고 그 결과를 허용진동기준과 비교하였다. 진동하중 하에서 시간에 따라 터널 천단, 어깨부 및 측벽부에서의 응답과 구조물 부재의 축응력, 전단응력 및 최대 휨압축응력이력을 제안된 기준과 비교하여 터널의 안정성을 검토하였다.

  • PDF