• Title/Summary/Keyword: Subtraction method

Search Result 431, Processing Time 0.033 seconds

Statics corrections for shallow seismic refraction data (천부 굴절법 탄성파 탐사 자료의 정보정)

  • Palmer Derecke;Nikrouz Ramin;Spyrou Andreur
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.7-17
    • /
    • 2005
  • The determination of seismic velocities in refractors for near-surface seismic refraction investigations is an ill-posed problem. Small variations in the computed time parameters can result in quite large lateral variations in the derived velocities, which are often artefacts of the inversion algorithms. Such artefacts are usually not recognized or corrected with forward modelling. Therefore, if detailed refractor models are sought with model based inversion, then detailed starting models are required. The usual source of artefacts in seismic velocities is irregular refractors. Under most circumstances, the variable migration of the generalized reciprocal method (GRM) is able to accommodate irregular interfaces and generate detailed starting models of the refractor. However, where the very-near-surface environment of the Earth is also irregular, the efficacy of the GRM is reduced, and weathering corrections can be necessary. Standard methods for correcting for surface irregularities are usually not practical where the very-near-surface irregularities are of limited lateral extent. In such circumstances, the GRM smoothing statics method (SSM) is a simple and robust approach, which can facilitate more-accurate estimates of refractor velocities. The GRM SSM generates a smoothing 'statics' correction by subtracting an average of the time-depths computed with a range of XY values from the time-depths computed with a zero XY value (where the XY value is the separation between the receivers used to compute the time-depth). The time-depths to the deeper target refractors do not vary greatly with varying XY values, and therefore an average is much the same as the optimum value. However, the time-depths for the very-near-surface irregularities migrate laterally with increasing XY values and they are substantially reduced with the averaging process. As a result, the time-depth profile averaged over a range of XY values is effectively corrected for the near-surface irregularities. In addition, the time-depths computed with a Bero XY value are the sum of both the near-surface effects and the time-depths to the target refractor. Therefore, their subtraction generates an approximate 'statics' correction, which in turn, is subtracted from the traveltimes The GRM SSM is essentially a smoothing procedure, rather than a deterministic weathering correction approach, and it is most effective with near-surface irregularities of quite limited lateral extent. Model and case studies demonstrate that the GRM SSM substantially improves the reliability in determining detailed seismic velocities in irregular refractors.

A Study on Orchestration in "Battle for The Glory" out of the Background Music in the Animation "Dragon Quest IV" (애니메이션 "드래곤 퀘스트 IV"의 배경음악 중 "Battle for The Glory"에 나타난 관현악법 연구)

  • Jung, Kil
    • Cartoon and Animation Studies
    • /
    • s.39
    • /
    • pp.321-348
    • /
    • 2015
  • The purpose of this study was to find a system and a progression principle in orchestral piece based on the outcome after comparatively analyzing the orchestral operation technique in "Battle for The Glory" out of the background music in the animation "Dragon Quest IV" by Koichi Sugiyama(1931~), who is a leading runner of Japan's animation music, based on functional parts daccord & Instrumentation Pattern, Rhythm Pattern, Voicing Pattern, and harmonic ratio by progression section devised by the writer. As a result, first, five themes in this music have specific instrumentation pattern, respectively. In a passage that is shown exposition, reprise, and representation in theme, the unity was emphasized by maintaining the same instrumentation pattern. On the contrary to this, a passage of being suggested new theme is being used the exchange method and addition & subtraction in musical instrument in order to strengthen diversity. Second, the voicing pattern is forming the vertical contrasting relationship of "thinness-thickness" on the whole. However, the diversity is being intensified that is changed into the structure of "thickness-thinness" in the third theme and of "thinness-thickness" that has two melodies in the fourth theme. Third, the rhythm pattern is forming the vertical contrasting relationship of "big-small" on the whole. However, the fifth theme is being given diversity with being changed into the structure of "small-big." Fourth, the harmony by progression section from the horizontal perspective is shown to be high in the proportion of unity in the section of being repeated and represented the theme and to be high in the proportion of diversity in the section of being suggested new theme. In this study, the balanced orchestral operation technique through the operation technique, which was used in this work, is what extracts the relationship of diverse proportions in the horizontal progression section based on the technique of vertical perspective. In this aspect, this analytical study is desired to be positioned as a new paradigm in establishing a theoretical system and an educational method in orchestration.

Change of Cerebral Blood Flow Distribution and Vascular Reserve according to Age in Koreans Measured by Tc-99m HMPAO Brain SPECT (한국 정상인에서 연령에 따른 뇌혈류분포와 혈류예비능의 변화: Tc-99m HMPAO SPECT에 의한 연구)

  • Song, Ho-Cheon;Bom, Hee-Seung;Sohn, Hye-Kyung;Jeong, Hwan-Jeong;Min, Jung-Jun;Kim, Ji-Yeul;Lee, Jae-Tae;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.247-261
    • /
    • 1999
  • Purpose: The aim of this study was to evaluate the normal values of regional cerebral blood flow (rCBF) and cerebrovascular reserve (CVR) in normal children to aged volunteers using Tc-99m HMPAO, Materials and Methods: Thirty four right-handed normal volunteers (20 males, 14 females, mean age $40.3{\pm}24.9$ years, range 4 to 82 years) were underwent rost/acetazolamide (ACZ) brain SPECT using Tc-99m HMPAO and the sequential injection and subtraction method. rCBF was estimated on the basis of a semiquantitative approach by means of right/left ratio, region/cerebellum and region to whole brain ratios in (rental, parietal, temporal, and occipital lobes, basal ganglia, thalami, and cerebellum. CVR was measured by means of % perfusion increase calculated as % mean count change compared to rest rCBF in each regions. Results: Mean values of right to left ratios range from 1.004 to 1.018, rCBF was highest in cerebellum and lowest in basal ganglia and thalami. Frontal and temporal rCBF decreased while occipital and thalamic rCBF increased according to age. No sexual difference of rCBF was noted. Mean CVR was $29.9{\pm}12.9%$. Mean CVR significantly increased to late teens, and declined thereafter. After 6th decade, CVR in both frontal lobes, left parietal lobe and right basal ganglia decreased significantly with advancing age. There was no sexual difference of CVR. Conclusion: Quantitative assessment of CVR was possible by ACZ Tc-99m HMPAO brain SPECT. It revealed that rCBF and CVR changed according to age in normal Korean volunteers. There was no sexual difference.

  • PDF

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.

Role of the Inferior Thyroid Vein after Left Brachiocephalic Vein Division During Aortic Surgery

  • Park, Hyung-Ho;Kim, Bo-Young;Oh, Bong-Suk;Yang, Ki-Wan;Seo, Hong-Joo;Lim, Young-Hyuk;Kim, Jeong-Jung
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.530-534
    • /
    • 2002
  • Background: In aortic surgery, division and ligation of the left brachiocephalic vein(LBV) may improve exposure of the aortic arch but controversy continues about the safety of this division and whether a divided vein should be reanastomosed after arch replacement was completed. The safety of LBV division and the fate of the left subclavian venous drainage after LBV division were studied. Material and Method: From November 1998 to January 2001, planned division and ligation of the LBV on the mid-line after median sternotomy was peformed in 10 patients during the aortic surgery with the consideration of local anatomy and distal aortic anastomosis. Assessment for upper extremity edema and neurologic symptoms, measurement of venous pressure in the right atrium and left internal jugular vein, and digital subtraction venography(DSV) of the left arm were made postoperatively. Result: In 10 patients there was improvement in access to the aortic arch for procedures on the ascending aorta or aortic arch. The mean age of patients was 62 years(range 24 to 70). Follow-up ranged from 3 weeks to 13 months. One patient died because of mediastinitis from methicilline-resistant staphylococcus aureus strain. All patients had edema on the left upper extremity, but resolved by the postoperative day 4. No patient had any residual edema or difficulty in using the left upper extremity during the entire follow-up period. No patient had postoperative stroke. Pressure difference between the right atrium and left internal jugular vein was peaked on the immediate postoperative period(mean peak pressure difference = 25mmHg), but gradually decreased, then plated by the postoperative day 4. In all DSV studies left subclavian vein flowed across the midline through the inferior thyroid venous plexus. Conclusion: We conclude that division of LBV is safe and reanastomosis is not necessary if inferior thyroid vein, which is developed as a main bridge connecting the left subclavian vein with right venous system, is preserved.

Observations of Oxygen Administration Effects on Visuospatial Cognitive Performance using Time Course Data Analysis of fMRI (뇌기능 자기공명영상의 시계열 신호 분석에 의한 공간인지과제 수행시 산소 공급의 효과 관찰)

  • Sohn Jin-Hun;You Ji-Hye;Eom Jin-Sup;Lee Soo-Yeol;Chung Soon-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.9-15
    • /
    • 2005
  • Purpose : This study attempted to investigate the effects of supply of highly concentrated $(30\%)$ oxygen on human ability of visuospatial cognition using time course data analysis of functional Magnetic Resonance Imaging (fMRI). Materials and Methods : To select an item set in the visuospatial performance test, two questionnaires with similar difficulty were developed through group testing. A group test was administered to 263 college students. Two types of questionnaire containing 20 questions were developed to measure the ability of visuospatial cognition. Eight college students (right-handed male, average age of 23.5 yrs) were examined for fMRI study. The experiment consisted of two runs of the visuospatial cognition testing, one with $21\%$ level of oxygen and the other with $30\%$ oxygen level. Each run consisted of 4 blocks, each containing control and visuospatial items. Functional brain images were taken from 37 MRI using the single-shot EPI method. Using the subtraction procedure, activated areas in the brain during visuospatial tasks were color-coded by t-score. To investigate the time course data in each activated area from brain images, 4 typical regions (cerebellum, occipital lobe, parietal lobe, and frontal lobe) were selected. Results : The average accuracy was $50.63{\pm}8.63$ and $62.50{\pm}9.64$ for $21\%\;and\;30\%$ oxygen respectively, and a statistically significant difference was found in the accuracy between the two types of oxygen (p<0.05). There were more activation areas observed at the cerebellum, occipital lobe, parietal lobe and frontal lobe with $30\%$ oxygen administration. The rate of increase in the cerebellum, occipital lobe and parietal lobe was $17\%$ and that of the frontal lobe, $50\%$. Especially, there were increase of intensity of BOLD signal at the parietal lobe with $30\%$ oxygen administration. The increase rate of the left parietal lobe was $1.4\%$ and that of the right parietal lobe, $1.7\%$. Conclusion : It is concluded that while performing visuospatial tasks, high concentrations of oxygen administration make oxygen administration sufficient, thus making neural network activate more, and the ability to perform visuospatial tasks increase.

  • PDF

Effect of Acupuncture on Regional Cerebral Blood Flow at Acupoints GV 20, GV. 26, LI. 4, ST. 36, SP. 6 Evaluated by Tc-99m ECD Brain SPECT (Tc-99m ECD 뇌혈류 SPECT를 이용한 백회, 인중, 합곡, 족삼리, 삼음교에서 체침의 뇌혈류에 대한 효과)

  • Song, Ho-Chun;Bom, Hee-Seung;Kang, Hwa-Jeong;Ahn, Soo-Gi;Kim, Seong-Min;Jeong, Hwan-Jeong;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.456-464
    • /
    • 2000
  • Purpose: To evaluate the effect of acupuncture on regional cerebral blood flow (rCBF) at acupoints suggested by oriental medicine to be related to the treatment of cerebrovascular diseases. Materials and Methods: Rest/acupuncture-stimulation Tc-99m ECD brain SPECT using a same-dose subtraction method was performed on 54 normal volunteers (34 males, 20 females, age range from 18 to 62 years) using six paradigms: acupuncture at acupoints GV. 20, GV. 26, LI. 4, ST. 36 and SP. 6. In the control study, needle location was chosen on a non-meridian focus 1 cm posterior to the right fibular head. All images were spatially normalized, and the differences between rest and acupuncture stimulation were statistically analyzed using SPM$^{(R)}$ for Windows$^{(R)}$. Results: Acupuncture applied at acupoint GV. 20 increased rCBF in both the anterior frontal lobes, the right frontotemporal lobes, and the left anterior temporal lobe and the left cerebellar hemisphere. Acupuncture at GV 26 increased rCBF in the left prefrontal cortex. Acupuncture at LI. 4 increased rCBF in the left prefrontal and both the inferior frontal lobes, and the left anterior temporal lobe and the left cerebellar hemisphere. Acupuncture at ST. 36 increased rCBF in the left anterior temporal lobe, the right inferior frontal lobes, and the left cerebellum. Acupuncture at SP. 6 increased rCBF in the left inferior frontal and anterior temporal lobes. In the control stimulation, no significant rCBF increase was observed. Conclusion: The results demonstrated a correlation between stimulation at each acupoint with increase in rCBF to the corresponding brain areas.

  • PDF

Improved Activity Estimation using Combined Scatter and Attenuation Correction in SPECT (단일광자방출단층촬영 영상에서 산란 및 감쇠 보정에 위한 절대방사능 측정)

  • Lee, Jeong-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.382-390
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the accuracy of radioactivity quantitation in Tc-99m SPECT by using combined scatter and attenuation correction. Materials and Methods: A cylindrical phantom which simulates tumors (T) and normal tissue (B) was filled with varying activity ratios of Tc-99m. We acquired emission scans of the phantom using a three-headed SPECT system (Trionix, Inc.) with two energy windows (photopeak window: $126{\sim}154keV$ and scatter window: $101{\sim}123keV$). We performed the scatter correction with dual-energy window subtraction method (k=0.4) and Chang attenuation correction. Three sets of SPECT images were reconstructed using combined scatter and attenuation correction (SC+AC), attenuation correction (AC) and without any correction (NONE). We compared T/B ratio, image contrast [(T-B)/(T+B)] and absolute radioactivity with true values. Results: SC+AC images had the highest mean values of T/B ratios. Image contrast was 0.92 in SC+AC, which was close to the true value of 1, and higher than AC (0.77) or NONE (0.80). Errors of true activity by SPECT images ranged from 1 to 11% for SC+AC, $22{\sim}47%$ for AC, and $2{\sim}16%$ for NONE in a phantom which was located 2.4cm from the phantom surface. In a phantom located 10.0cm from the surface, SC+AC underestimated by 24%, NONE 40%. However, AC overestimated by 10%. Conclusion: We conclude that accurate SPECT activity quantitation of Tc-99m distribution can be achieved by dual window scatter correction combind with attenuation correction.

  • PDF

$^{99m}Tc-MAG_3$ Elimination Index on Normal Functioning Transplanted Kidney ($^{99m}Tc-MAG_3$ 제거지수를 이용한 이식신장의 기능평가)

  • Jeon, Woo-Jin;Kim, Ju-Heon;Park, Mi-Ok;Lee, Hee-Jung;Hyun, Jung-Ae;Zeon, Seok-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.79-83
    • /
    • 1995
  • Purpose : We analysed $^{99m}Tc-MAG_3$ renal scans to evaluate renal function of transplanted kidney and to detect various renal transplant complications, measuring the ratio of renal radioactivity at three minutes to that at 20 minutes(elimination index). Material and Methods : The fifty seven renal transplantation recipients were studied. There were 50 normal functioning transplanted kidneys as group I and 7 abnormal function-ing transplanted kidney, including 5 cases of acute renal rejection, 2 cases of acute tubular necrosis as group IIl. The protocol consisted of: (1) $^{99m}Tc-MAG_3$ 740MBq injection intravenously : (2) sequential imaging for 2min(60two-second images) followed by 30min(30 sixty-second images) : (3) drawing of region of interest(ROI) on renal imaging; (4) time-activity corves were generated from renal ROI after background subtraction, and time of maximum activity($T_{max}$) and half time of maximal peak radioactivity($T_{1/2}$) were produced in the renogram curve. (5) EI through Bischof-Delaloye method as determined on the renogram curve. Results : Normal group( I ) shows mean EI of 2.21(95.0% Confidence limit of 2.01-2.87), $T_{max}$ of 154 sec, $T_{1/2}$ of 1,139 sec. Abnormal group(II) shows mean EI of 0.74, $T_{max}$ of 1,466 sec, $T_{1/2}$ of 19,224 sec. The EI, $T_{max}$, $T_{1/2}$, BUN and serum creatinine values are significantly different between normal group(I) and abnormal group(II) (p<0.0001). Conclusion : By measuring EI with $^{99m}Tc-MAG_3$, renal function of transplanted kidney could be easily evaluated and various complications could be detected early.

  • PDF

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.