• Title/Summary/Keyword: Subtraction Technique

Search Result 155, Processing Time 0.037 seconds

Supraceliac Aorta Bypass Surgery For Juxtarenal Aortic Occlussive Disease -2 Cases - (신장근접 대동맥 폐색증의 상복강대동맥 우회술)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.105-111
    • /
    • 1992
  • Total atherosclerotic obstruction of the juxtarenal abdominal aorta is a relatively rarely encountered form of atherosclerotic vascsular disease, accounting for less than 5% of all arterial obstrutive disease. We have encountered two patients with such lesions, both of whom were admitted for intermittent claudication of the lower extremities and symptoms of vascular ischemia. Digital subtraction angiography[DSA] was performed on both patients, the results of which revealed total obstruction of the aorta just inferior to the renal arteries without involving the latter. Operative technique involved the use of the sup-raceliac aorta as the site of proximal anastomosis of aortofemoral bypass followed by a fem-orofemoral bypass graft with Smm sized Woven Dacron[Vascutek] through a subcutaneous tunnel within the retroperitoneal space. Both patients experienced restoration of blood flow distal to the obstruction postoperatively without any complications, and OPD follow-up one month postoperatively and postoperative DSA showed evidence of continued graft patency with persistent symptomatic improvement.

  • PDF

A Symbol Synchronization Algorithm With an Adaptive Threshold Establishment Method For OFDM Systems (OFDM시스템을 위한 적응 문턱값 설정방식의 심볼동기화 알고리듬)

  • Song, Dong-Ho;Joo, Chang-Bok
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.6
    • /
    • pp.213-224
    • /
    • 2003
  • The proposed algorithm can always set up the optimal threshold value regardless of channel characteristics using an adaptive threshold establishment method that determines the threshold level according to channel noise power, and then it uses the specially designed training symbols that can make the algorithm's estimation performance be less sensitive to power delay profile variation in a multipath channel. In result, the estimation performance of the proposed technique is less affected by channel characteristic variation.

ATC: An Image-based Atmospheric Correction Software in MATLAB and SML

  • Choi, Jae-Won;Won, Joong-Sun;Lee, Sa-Ro
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.5
    • /
    • pp.417-425
    • /
    • 2008
  • An image-based atmospheric correction software ATC is implemented using MATLAB and SML (Spatial Modeler Language in ERDAS IMAGINE), and it was tested using Landsat TM/ETM+ data. This ATC has two main functional modules, which are composed of a semiautomatic type and an automatic type. The semi-automatic functional module includes the Julian day (JD), Earth-Sun distance (ESD), solar zenith angle (SZA) and path radiance (PR), which are programmed as individual small functions. For the automatic functional module, these parameters are computed by using the header file of Landsat TM/ETM+. Three atmospheric correction algorithms are included: The apparent reflectance model (AR), one-percent dark object subtraction technique (DOS), and cosine approximation model (COST). The ACT is efficient as well as easy to use in a system with MATLAB and SML.

Magnetization Transfer Contrast Angiography for Organized Thrombosed Intracranial Aneurysm in TOF MR Angiography: a Case Report

  • Kang, Dong-Hun;Lee, Hui Joong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.266-271
    • /
    • 2018
  • A 66-year-old woman was referred for treatment of incidental detection of two intracranial aneurysms. Time-of-flight MR angiography (TOF MRA) revealed two aneurysms at the M1 segment of the right middle cerebral artery, and clinoid segment of left internal carotid artery, respectively. On digital subtraction angiography, there was a saccular aneurysm on the left internal carotid artery, but the other aneurysm was not detected on the right middle cerebral artery. Based on comprehensive review of imaging findings, organized thrombosed aneurysm was judged as the most likely diagnosis. In the presented report, magnetization transfer (MT) pulse to TOF MRA was used, to differentiate aneurysm-mimicking lesion on TOF MRA. We report that MT technique could be effective in differentiating true aneurysm, from possible T1 high signal artifact on TOF MRA.

Simultaneous Addition and Subtraction of Optical Images by Using the Extended Incoherent Source (인코히런트 광원을 이용한 영상의 동기 가감)

  • Park, Hyung Rae;Jeon, Seok Hee;Park, Han Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.6
    • /
    • pp.961-967
    • /
    • 1986
  • A technique of optical image synthesis with an extended incoherent source is presented and compared with the coherent method. A holographic diffraction grating is fabricated by using Michelson interferometer, and by equalizing the 8th-order to the 2nd-order diffraction efficiency, complex amplitude addition and subtracdtion of optical images are simultaneously realized. The experiment shows that the quality of synthesized optical images in the incoherent method is improved in comparison with that of the coherent method by suppressing the coherent artifact noise.

  • PDF

Histogram Learning-based Solar Power Plant Failure Reading System (히스토그램 학습 기반 태양광발전소 고장 판독 시스템)

  • Youm, SungKwan;Shin, Kwang-Seong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.572-573
    • /
    • 2021
  • By optimizing the development of IoT-type thermal image-based photovoltaic fault detection equipment and interworking with drones using a drone with an intelligent path movement function, real-time analysis of the acquired image data facilitates fault reading of solar power plants. , design a system that can read out the failure of a solar panel using the image subtraction analysis technique and the presentation of the basic technology that can improve the power generation rate of the solar power plant and make an efficient maintenance model.

  • PDF

Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode (뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.961-968
    • /
    • 2019
  • The purpose of this study was to evaluate the usefulness of cerebral angiography in each energy level by using dual energy technique in CT. Methods were performed on 15 DE images and SE images of CT angiography. For the analysis of images, mean value, standard deviation, SNR and CNR value were determined by setting ROI on MCA, brain parenchyma tissue, and back ground. As a result of concurrent visual evaluation with Likert 5 point scale, the clearest MCA image was confirmed at DE 40 keV and SE 120 kVp(p>0.05). The SNR value of the SE image was measured to be similar to the 40 keV energy level of the DE image. The low energy level image of 40 keV and 50 keV was measured with a high SNR and the contrast ratio was higher than that of the high energy image.

A study on counting number of passengers by moving object detection (이동 객체 검출을 통한 승객 인원 개수에 대한 연구)

  • Yoo, Sang-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.21 no.2
    • /
    • pp.9-18
    • /
    • 2020
  • In the field of image processing, a method of detecting and counting passengers as moving objects when getting on and off the bus has been studied. Among these technologies, one of the artificial intelligence techniques, the deep learning technique is used. As another method, a method of detecting an object using a stereo vision camera is also used. However, these techniques require expensive hardware equipment because of the computational complexity of used to detect objects. However, most video equipments have a significant decrease in computational processing power, and thus, in order to detect passengers on the bus, there is a need for an image processing technology suitable for various equipment using a relatively low computational technique. Therefore, in this paper, we propose a technique that can efficiently obtain the number of passengers on the bus by detecting the contour of the object through the background subtraction suitable for low-cost equipment. Experiments have shown that passengers were counted with approximately 70% accuracy on lower-end machines than those equipped with stereo vision camera.

Computer Simulations of Hoffman Brain Phantom:Sensitivity Measurements and Optimization of Data Analysis of 〔Tc-99m〕ECD SPECT Before and After Acftazolamide Administraton (Acetazolamide 사용전후 〔Tc-99m〕 EDC SPECT 데이타 분석 방법의 최적화 및 민감도 측정)

  • Kim, Hee-Joung;Lee, Hee-Kyung
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.71-81
    • /
    • 1995
  • Consecutive brain 〔Tc-99m〕ECD SPECT studies before and after acetazolamide (Diamox) administration have been performed with patients for the evaluation of cerebrovascular hemodynamic reserve. However, the quantitaitve potential of SPECT Diamox imaging is limited as a result of degrading fractors such as finite detector resolution, attenuation, scatter, poor counting statistics, and methods of data analysis. Making physical measurements in phantoms filled with known amounts of radioactivity can help characterize and potentially quantify the sensitivities. However, it is often very difficult to make a realistic phantom simulating patients in clinical situations. By computer simulation, we studied the sensitivities of ECD SPECT before and after Diamox administration. The sensitivity is defined as ($\Delta$N/N)/($\Delta$S/S)$\times$100%, where $\Delta$N denotes the differences in mean counts between post-and pre-Diamox in the measured data, N denotes the mean counts before Diamox in the measure data, $\Delta$S denotes the differences in mean counts between post-and pre-Diamox in the model, and S denotes the mean counts before Diamox in the model. In clinical Diamox studies, the percentage changes of radioactivity could be determined to measure changes in radioactivity concentration by Diamox after subtracting pre-from post-Diamox data. However, the optimal amount of subtraction for 100% sensitivity is not known since this requires a thorough sensitivity analysis by computer simulation. For consecutive brain SPECT imaging model before and after Diamox, when 30% increased radioactivity concentrations were assingned for Diamox effect in model, the sensitivities were measured as 51.03, 73.4, 94.00, 130.74% for 0, 100, 150, 200% subtraction, respectively. Sensitivity analysis indicated that the partial voluming effects due to finite detector resolution and statistical noise result in a significant underestimation of radioactivity measurements and the amount of underestimation depends on the. % increase of radioactivity concentration and % subtraction of pre-from post-Diamox data. The 150% subtraction appears to be optimal in clinical situations where we expect approximately 30% changes in radioactivity concentration. The computer simulation may be a powerful technique to study sensitivities of ECD SPECT before and after Diamox administration.

  • PDF

THE CURRENT STATUS OF THE AKARI MID-INFRARED ALL-SKY DIFFUSE MAPS

  • Amatsutsu, Tomoya;Ishihara, Daisuke;Kondo, Toru;Kaneda, Hidehiro;Oyabu, Shinki;Yamagishi, Mitsuyoshi;Nakamichi, Keichiro;Sano, Hidetoshi;Onaka, Takashi
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.25-27
    • /
    • 2017
  • We are creating all-sky diffuse maps from the AKARI mid-infrared survey data with the two photometric bands centered at wavelengths of 9 and $18{\mu}m$. The AKARI mid-infrared diffuse maps achieve higher spatial resolution and higher sensitivity than the IRAS maps. In particular, the $9{\mu}m$ data are unique resources as an all-sky tracer of the emission of polycyclic aromatic hydrocarbons (PAHs). However, the original data suffer many artifacts. Thus, we have been developing correction methods. Among them, we have recently improved correction methods for the non-linearity and the reset anomaly of the detector response. These corrections successfully reduce the artifact level down to $0.1MJy\;sr^{-1}$ on average, which is essential for discussion on faint extended emission (e.g., the Galactic PAH emission). We have also made progress in the subtraction of the scattered light caused in the camera optics. We plan to release the improved diffuse maps to the public within a year.