• Title/Summary/Keyword: Subsurface settlement

Search Result 17, Processing Time 0.029 seconds

Excessive Settlement Back-Analysis of Railway Embankment on Soft Soils during Service

  • Ahn, Taebong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.13-17
    • /
    • 2019
  • This paper presents case history of railway embankment excess settlement on soft clay during service in southern region of Korea. A lot of field observations show that the measured settlements are a lot larger than settlements actually calculated in this area. Back analysis is carried out to verify the soil parameters which are intended to investigate in the subsurface exploration phase and later in a laboratory test program. Recommendations and causes for the engineering practice are suggested to review the determination of excess settlements and, consequently, to improve the settlement prediction. This enormous discrepancy is due to the passing over secondary consolidation, and the design filling did not meet to real construction filling. Immediate settlement could be subsidiary factor of excess settlement.

Elastic settlements of identical angular footings in close proximity

  • R. Sarvesha;V. Srinivasan;Anjan Patelb
    • Geomechanics and Engineering
    • /
    • v.32 no.2
    • /
    • pp.193-207
    • /
    • 2023
  • In general, the numerous classical approaches available in the literature can anticipate the settlement of shallow foundations. As long as the footings are not in close proximity to other subsurface buildings, the findings achieved using these methods are legitimate and acceptable. However, due to increased urbanisation and land scarcity, footings are frequently built close together. As a result, these footings' settlement behaviour differs from those of isolated footings. A simpler approach for assessing the settlement behaviour of two square or rectangular footings placed in close proximity is presented in this work. A Parametric study has been carried out to examine the interference effect on the settlement of these footings placed in close vicinity on the surface of a homogeneous, isotropic and elastic soil medium. The interaction factors are examined by varying the different aspect ratios (L/B), clear spacing ratio (S/B) and intensity of loading on the right footing with respect to the left footing. Further, variation of the settlement ratio (δ/B) with respect to embedment depth ratio Df/B is examined. For square and rectangular footings, the interference settlement profile is also investigated by varying the clear spacing ratio (S/B) and the degree of loading. The results were compared to 3D finite element analysis and experimental data that were available.

Determination of K values from tunnel model tests in sandy ground (터널모형실험을 통한 사질토 지반에서의 K값의 산정)

  • Lee, Yong-Joo;Ryu, Chang-Youl
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.1
    • /
    • pp.87-94
    • /
    • 2010
  • This study mainly focused on the subsurface settlement due to shallow and deep tunneling in sandy ground. In order to figure out theoretical deformation patterns in association with the ground loss during the progress of tunneling, laboratory model tests using aluminum rods and finite element analyses using the CRISP program were carried out. As a result of comparison between the model test and the finite element analysis, the similar deformation patterns were found. In addition, it was identified that the most K values obtained from both the FEA and the model tests were distributed between Dyer et al. (1996) and Moh et al. (1996) of the field observation data. Based on the model test data, the linear equation of K for the sandy soil could be obtained.

Settlement prediction for footings based on stress history from VS measurements

  • Cho, Hyung Ik;Kim, Han Saem;Sun, Chang-Guk;Kim, Dong Soo
    • Geomechanics and Engineering
    • /
    • v.20 no.5
    • /
    • pp.371-384
    • /
    • 2020
  • A settlement prediction method based on shear wave velocity measurements and soil nonlinearity was recently developed and verified by means of centrifuge tests. However, the method was only applicable to heavily overconsolidated soil deposits under enlarged yield surfaces. In this study, the settlement evaluation method was refined to consider the stress history of the sublayer, based on an overconsolidation ratio evaluation technique, and thereby incorporate irrecoverable plastic deformation in the settlement calculation. A relationship between the small-strain shear modulus and overconsolidation ratio, which can be determined from laboratory tests, was adopted to describe the stress history of the subsurface. Based on the overconsolidation ratio determined, the value of an empirical coefficient that reflects the effect of plastic deformation over the elastic region is determined by comparing the overconsolidation ratio with the stress increment transmitted by the surface design load. The refined method that incorporate this empirical coefficient was successfully validated by means of centrifuge tests, even under normally consolidated loading conditions.

A study of settlement safety for existing ground with twin tunnel progressing (쌍굴굴착으로 인한 인근지반의 침하 안전에 관한 연구)

  • 정대석
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.4
    • /
    • pp.55-61
    • /
    • 1992
  • An engineer designing a tunnel in an urban area should be to predict the magnitude and distribution of ground movements which are important to Investigate the potential damage to the existing structures around tunnel. The present study examines available theories and emprical equations, and tries to investigate quantativily ground movements around tunnel with tunnel progressing. Approcaches to the problem of ground movements associated with twin tunnel was and elasto - plastic finite element method. Typical section in Seoul Subway were selected in numerical study. The analysis and study was done with respect. to surface, subsurface and crown settlements with varying ground conditions, tunnel geommetry and construction conditions.

  • PDF

The Variation of Density and Settlement for Contaminated Sediments During Electrokinetic Sedimentation and Remediation Processes (오염퇴적토에 대한 동전기적 침전 및 정화 공정에서의 시료 밀도 및 침하 변화 특성)

  • Chung, Ha-Ik
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.9
    • /
    • pp.5-14
    • /
    • 2006
  • Generally, the sediments contain significant water, clay, colloidal fraction and contaminants, and can result in soft strata with high initial void, and its potential hazards in subsurface environments exist. Electrokinetic technique has been used in sedimentation for volume reduction of slurry tailing wastes and in remediation for extraction of contaminants from contaminated soils. In this research, the coupled effects of sedimentation and remediation of contaminated sediments are focused using electrokinetic sedimentation and remediation techniques from experimental aspects. A series of laboratory experiments including variable conditions such as initial solid content of the specimen, concentration level of the contaminant, and magnitude of applied voltage are performed with the contaminated sediment specimens mixed with ethylene glycol. Commercially available high specification Kaolin was used to simulate slurried sediment. From the test results, the settlement of specimen increases with increasing of applied voltage and decreasing of solid content and contamination level. The density of specimen increases due to settlement of specimen in the process of electrokinetic sedimentation and decreases due to extraction of organic contaminant in the process of electrokinetic remediation.

Field Measurements of Ground Movements Around Tunnel (현장계측에 의한 터널주변지반의 변위연구)

  • 홍성완;배규진
    • Geotechnical Engineering
    • /
    • v.1 no.2
    • /
    • pp.41-54
    • /
    • 1985
  • Generally, ground settlements and lateral displacements are accompanied by underground excavation associated with open-cut or tunnling. These ground movements cause a harmful influence upon nearby super.structures and sub-structures. Occasionally, the ground movements may pose serious problems as the function of the nearby structures may be disrupted. Therefore, prior to the subway construction in an urban area, it is necessary to identify the causes of ground settlements and estimating the extent St the magnitude of ground movements since any potential damage to the nearby structures such as gas lines, water mains, high buildings and cultural assets must be assessed. The research was performed mainly on ground movements such as surface settlements, lateral displacements, subsurface settlements and crown settlements to predict the maximum settlement and settlement zone, and to identify the causes of ground settlements in NATM sections of Busan subway. As a result, it was found that lateral distribution of settlements could be approximated reasonably by a Gaussian normal probability curve and longitudinal distribution of settlements by a cumulative Gaussian probability curve, and that the early closure of temporary invert was very important to minimize ground settlements.

  • PDF

Application of Electrical Resistivity Survey For Contaminant Evaluation at Uncontrolled Landfills

  • Lee Seong-Soon;Yoon Hee-Sung;Lee Kang-Kun;Lee Jin-Young;Kim Chang-Gyun;Yu Young-Chul
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.432-435
    • /
    • 2006
  • To evaluate geology and extent of leachate migration around the landfills, electrical resistivity survey were conducted in area of uncontrolled landfills in Cheonan and Wonju. The Cheonan landfill is located above the paddy fields and the resistivity survey lines were crossed to confirm possible pollution of the paddy fields by leakage of the landfill leachate. In Wonju, the landfill and the downgradient paddy fields are divided by a concrete barrier wall. At the bottom of the landfill, there is a leachate settlement system but has not been in operation. And a total of 4 survey line installed (1 parallel and 3 perpendicular to mean groundwater flow direction). According to the resistivity survey results, the landfill leachate in Cheonan appeared to be restricted only within the interior of the landfill, not to migrate into the subsurface of the paddy fields. These results are well consistent with electrical conductivity values of groundwaters obtained from a periodic analysis of water qualities. In Wonju, however, it was inferred that the leachate emanating from the landfill migrated beneath the abandoned leachate settlement system and it would reach the downgradient paddy field.

  • PDF

Soil Contamination Analysis and its Treatment for Landfilled Area (폐기물 매립지반 오염도 분석 및 처리방안에 대한 연구)

  • Shin, Eun-Chul;Kang, Jeong-Ku;Jang, Woo-Lam
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • When some structures are constructed over the sanitary landfill, the waste should be treated by means of replacement and other ways. Otherwise, various problems like a ground contamination, settlement, reduction of bearing capacity and others may be generated. To find out the optimal method of treatment, the properties of the ground have to be inspected. In this study, the preliminary investigation was conducted to find out the characteristic of this site which is considered as insanitary waste landfill. Furthermore, the shape and the amount of the waste was investigated by subsurface investigation like a boring and sampling methods. In addition, the degree of ground contamination and disposal method of refuse was examined.

  • PDF

The Effects of Sand Compaction by Watering through Field Compaction Test and Numerical Analysis (현장 및 수치해석을 통한 모래 물다짐지반의 다짐효과 연구)

  • Chun, Byungsik;Jang, Younsoo;Kim, Kwanggyu;Park, Dukhyum;Sung, Hwadon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.13-19
    • /
    • 2007
  • This study examines a cause for damage of synthetic resins straight pipe occurred after pipe construction of underground electric power duct pipelines of ${\bigcirc}$ section work, ${\bigcirc}$ line, ${\bigcirc}{\bigcirc}$ city railroad. For this, we analyzed a parameter used for plan and structural analysis through a literature review. And the site condition was analyzed in detail, and test construction of the pipe line that simulated the site pipe line and test on compaction by watering were performed. In addition, an examination on subsurface settlement influence of foundation ground through a structural safety and a numerical analysis of power transmission pipe line was performed. As a result of the performance, relative density gained by compaction by watering was more than average and relative degree of compaction according to technical specification standard showed the result of about 90% in the case of good compaction by watering.

  • PDF