• Title/Summary/Keyword: Subsonic Flow

Search Result 220, Processing Time 0.024 seconds

Effect of the Stagnation Temperature on the Normal Shock Wave

  • Zebbiche, Toufik
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.10 no.1
    • /
    • pp.1-14
    • /
    • 2009
  • When the stagnation temperature increases, the specific heat does not remain constant and start to vary with this temperature. The gas is perfect, it's state equation remains always valid, except, it was called by gas calorically imperfect or gas at high temperatures. The purpose of this work is to develop a mathematical model for a normal shock wave normal at high temperature when the stagnation temperature is taken into account, less than the dissociation of the molecules as a generalisation model of perfect for constant heat specific. A study on the error given by the perfect gas model compared to our model is presented in order to find a limit of application of the perfect gas model. The application is for air.

Transonic/Supersonic Flutter Analysis of a Fighter Wing with Tip-Store (끝단 장착물이 있는 항공기 날개의 천음속/초음속 플러터 해석)

  • Kim, Dong-Hyun;Lee, In
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1198-1203
    • /
    • 2000
  • In this study, a nonlinear aeroelastic analysis system for the fighter wing with tip-store has been developed additionally in the transonic and supersonic flow region. The unsteady CFD code based on the transonic small disturbance theory has been incorporated to consider the numerical capability for the aerodynamic nonlinear effects. The coupled time-integration method is used to observe the detailed nonlinear aeroelastic responses for elastic wings in their flight. condition. A conservative wing-box model of a fighter wing with tip-store is modeled by MSC/PATRAN and the corresponding free vibration analysis has been performed by MSC/NASTRAN. The results of flutter analyses are presented in the subsonic, transonic and supersonic flow regime.

  • PDF

A PIV STUDY ON A DELTA WING(LEX) MODEL FLOW IN MODERN AIRCRAFT

  • LEE Young-Ho;SOHN Myoung-Hwan;LEE Hyun;KIM Jeong-Hwan;KIM Beom-Seok
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.53-61
    • /
    • 2001
  • Highly swept leading edge extensions(LEX) applied to delta wings have greatly improved the subsonic maneuverability of contemporary fighters. Fundamental approach by PIV method was adopted to study the basic flow of the vortex pair formation appearing on a delta wing model with or without LEX. Three angles of attacks$(16^{\circ},\;24^{\circ},\;28^{\circ})$ and four measuring section of chord length(LEX-on) and three section(LEX-off) were selected as experimental conditions. From the PIV analysis, maximum vorticity was found at a given chord length and maximum velocity was also detected at larger chord length where stronger vortex was generated. Furthermore, the effect of LEX was remarkable at the vortex pair distance indicating narrower distance at LEX-on case.

  • PDF

Design of Thermal Vapor Compressor by Numerical Analysis and Experimental Verification (전산해석을 통한 열증기압축기 설계와 실험적 검증)

  • Park, Il-Seouk;Park, Sang-Min;Ha, Ji-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.6 s.33
    • /
    • pp.33-39
    • /
    • 2005
  • A thermal vapor compressor in which the subsonic/supersonic flow appears simultaneously, has been accurately designed through the CFD analysis for the various shape parameters such as the primary nozzle shape, converging duct shape, mixing tube diameter, and so on. The performance of the developed thermal vapor compressor has been experimentally verified to be installed in a Multi Effect Desalination(MED) plant as an important element. In this paper, the effects of each parameter are discussed on the basis of CFD results and the experimental results for various boundary conditions(motive pressure, suction pressure, and discharge pressure) are presented in compared with CFD results. The two results show a good agreement with each other within 2 % accuracy with regard to the entrainment ratio.

A Study on the Flow Control in a Wide Angle Diffuser by Installation of a Rectangular Prism (광각디퓨저의 내부에 설치된 장방형 각주를 이용한 유동제어에 관한 연구)

  • Lee, Cheol-Jae;Cho, Dae-Hwan
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.57-62
    • /
    • 2011
  • In this study, a experimental work to investigate the influence of a turbulent wake flow on the velocity distribution of a diffuser with PIV method. The turbulent wake is generated by a rectangular prism, which is installed at the inlet of a diffuser. The results show that the velocity recovery of the subsonic diffuser is dependent on the height and location of rectangular prism. It is found that a certain height of the rectangular prism to generate the turbulent wake give a better velocity recovery, compared with no rectangular prism.

The Effect of Cross-flow on Liquid Atomization (횡단유동이 액체 미립화에 미치는 영향)

  • Kim, Jong-Hyun;Cho, Woo-Jin;Lee, In-Chul;Lee, Bong-Soo;Koo, Ja-Ye
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.87-92
    • /
    • 2008
  • The breakup processes and spray plume characteristics of liquid jets injected in subsonic air cross-flows were experimentally studied. The behaviors of column, penetration, breakup of plain liquid jet and droplet sizes, velocities have been studied in non-swirling cross-flow of air. Nozzle has a 1.0 mm diameter and Lid ratio=5. Experimental results indicate that the breakup point is delayed by increasing air momentum, the penetration decreases by increasing Weber number and the split angle is increased by increasing air velocity or decreasing injection velocity. SMD increases according as increasing height or decreases in accordance with increasing air velocity. This phenomenon is related to the momentum exchange between column waves and cross-flow stream. Droplet vector velocities were varied from 11.5 to 33 m/s. A higher-velocity region can be identified in down edge region at Z/d=40, 70 and 100. Lower-velocity region were observed on bottom position of the spray plume.

Experimental Study on Turbulent Structure of Flow around KRISO 3600TEU Container Double-deck Model (KRISO 3600TEU 콘테이너 모형선 주위 유동의 난류구조에 관한 실험적 연구)

  • Hak-Rok Kim;Sang-Joon Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.3
    • /
    • pp.8-14
    • /
    • 1999
  • The flor characteristics around the KRISO 3600TEU container ship model have been experimentally investigated in a subsonic wind tunnel. The mean velocity and turbulence characteristics in the stern and wake regions were measured using an x-type hot-wire probe. The flow characteristics in the stern and near wake regions revealed a complicated three-dimensional flow pattern. The measured results showed clearly the formation of longitudinal vortices and their effect on the flow pattern in the wake region. The shear layer developed along the ship model expands showly to the downward direction. The turbulence statistics measured can be used as comparative data of numerical simulations and provide insights into development of accurate turbulence models for the ship design.

  • PDF

Compressibility correction of the Panel Method in Flow Analysis of a High Subsonic Turbine Cascade (고 아음속 터빈 캐스케이드 유동 해석을 위한 패널법의 압축성 보정)

  • Kim, Hark-Bong;Kim, Jin-Kon;Kwak, Jae-Su;Kang, Jeong-Seek
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.49-54
    • /
    • 2007
  • Flow analysis in a turbine cascade by Euler or Navier-Stokes equation gives relatively accurate solution, however, those method require large computer memory or computing time. on contrast, the panel method, which is applied to incompressible and inviscid flow, provides fast and reasonal solution but the compressibility correction is required for a high air velocity case. In this paper, the compressibility corrected panel method was applied in order to find velocity distribution on turbine blades. Results showed that the calculated velocity in a turbine cascade by the compressibility corrected panel method gave good agreement with experimental results or the solution by finite volume method for compressible flow.

  • PDF

Effect of Gas-liquid Ratio on Characterization of Two-Phase Spray Injected into a Cross-flow (횡단유동에 분사된 이유체 분무의 기체 액체비가 분무특성에 미치는 영향)

  • Cho, Woo-Jin;Lee, In-Chul;Lee, Bong-Su;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • The effect of two-phase spray injected into subsonic cross-flow was studied experimentally. External-mixing of two-phase spray from orifice nozzle with L/d of 3 was tested with various air-liquid ratio that ranges from 0 to 59.4%. Trajectory of spray and breakup phenomena were investigated by shadowgraph photography. Detailed spray structure was characterized in terms of SMD, droplet velocity, and volume flux using PDPA. Experimental results indicate that penetration length was increased and collision point of liquid jets approached to nozzle exit and distributions of mist-like spray were obtained by increasing air-liquid ratio.

Compressibility correction of the Panel Method in Flow Analysis of a High Subsonic Turbine Cascade (고 아음속 터빈 캐스케이드 유동 해석을 위한 패널법의 압출성 보정)

  • Kim, Hark-Bong;Kim, Jin-Kon;Kwak, Jae-Su;Kang, Jeong-Seek
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.23-28
    • /
    • 2008
  • Flow analysis in a turbine cascade by Euler or Navier-Stokes equation gives relatively accurate solution, however, those method require large computer memory or computing time. On contrast, the panel method, which is applied to incompressible and inviscid flow, provides fast and reasonal solution but the compressibility correction is required for a high air velocity case. In this paper, the compressibility corrected panel method was applied in order to find velocity distribution on turbine blades. Results showed that the calculated velocity in a turbine cascade by the compressibility corrected panel method gave good agreement with the solution by finite volume method for compressible flow.