• Title/Summary/Keyword: Suboptimal

Search Result 449, Processing Time 0.027 seconds

Studies on health management and nutritional evaluation by milk components analysis in dairy cows III. Relationship between conception rates, and milk urea nitrogen and milk protein concentration in a large dairy herd of high yielding cows (젖소에서 유성분 분석을 통한 영양상태 평가 및 건강관리에 관한 연구 III. 고능력우 위주의 대규모 목장에서 우유중 단백질과 요소태질소 수준이 수태율에 미치는 영향)

  • Moon, Jin-san;Joo, Yi-seok;Jang, Gum-chan;Yoon, Yong-dhuk;Lee, Bo-kyeun;Park, Young-ho;Son, Chang-ho
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.2
    • /
    • pp.383-391
    • /
    • 2000
  • Milk urea nitrogen (MUN) determination is being used an indicator of the protein-energy balance in dairy herds. A faulty balance can be corrected to optimize milk production and animal health. This parameter is regarded as a potential tool to evaluate suboptimal feeding practices and reproductive disorders. Therefore, the purpose of this study was to investigate the response of milk composition by regular feeding analysis and to compared the relationship between MUN and milk protein(MP) and fertility at the insemination period in Holstein dairy cows. Total of 355 artificial insemination (AI) for 150 Holstein cows in the herd were used to examine the relationship between MUN and MP content and conception rate. The AI occured for the cows 50 to 150 day in milk, and MUN and MP concentration were determined using automated infrared procedures. The mean${\pm}$standard deviation of MUN and MP concentration in the herd were $15.6{\pm}2.1mg/dl$ and $3.23{\pm}0.38%$, respectively. MUN contents of bulk milk were increase by elevated crude protein intake. The conception rate was lower in the cows in which the level of MUN was lower than > 8.0mg/dl (10.0%) or > higher than 25mg/dl (15.4%) relative to the cows in MUN content of 12.0~17.9 mg/dl (36.7%) at the time of insemination. Also, lower MP than 3.0% or higher MP than 3.25% were associated with a lower conception rates. Consequently, MUN and MP analyses may be used serve as a monitoring tool of protein and energy nutritional balance to improve reproduction efficiency in Holstein dairy cows.

  • PDF

Effect of Some Growth Regulators on Growth Efficiency of Panax ginseng (고려인삼의 생장효율에 미치는 수종 생장조절제의 효과)

  • Park, Hoon;Yoon, Jong-Hyuk;Lee, Mee-Kyoung
    • Journal of Ginseng Research
    • /
    • v.12 no.2
    • /
    • pp.158-163
    • /
    • 1988
  • P. ginseng seedlings treated with GA,2,4-D and B-9 (N,N-dimethylsuccinamic acid) were grown under dark. Growth efficiencies ($E_1$ = St/Ro, $E_2$ = St1(Ro-Rt), $E_3$ = (Ro- Rt)/ Ro where St. Ro and Rt are shoot weight, initial root weight and root weight at time 1. respectiv$E_1$y) and other r$E_1$ated factors and their interr$E_1$ationship were investigated. $E_1$ and $E_3$ showed quadratic r$E_1$ation with temperature change while $E_2$ showed negative linear r$E_1$ation. $E_1$ depended on more $E_3$ component than $E_2$ component. The values of $E_2$ and $E_3$ are almost same. $E_2$ was greater than that reported previously suggesting large variation between roots. GA greatly increased $E_2$ and $E_3$ in supraoptimum temperature range while B-9 greatly decreased $E_3$ in all temperature range and $E_2$ in suboptimum range. Shoot weight showed highly significant positive linear corr$E_1$ation with substrate amount in most cases of PGR and temperature and with respiration loss in some cases. Respiration loss showed significant linear corr$E_1$ation positiv$E_1$y with $E_1$ and $E_3$ and negativ$E_1$y with $E_2$ only in suboptimal temperature range.

  • PDF

Total Degradation Performance Evaluation of the Time- and Frequency-Domain Clipping in OFDM Systems (OFDM 시스템에서 시간 및 주파수 영역 클리핑의 Total Degradation 성능평가)

  • Han, Chang-Sik;Seo, Man-Jung;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.17-22
    • /
    • 2007
  • OFDM (Orthogonal Frequency Division Multiplexing) is a special case of multicarrier transmission, where a single data stream is transmitted over a number of lower-rate subcarrier. One of the main reasons to use OFDM is to increase robustness against frequency-selective fading or narrowband interference. Unfortunately, an OFDM signal consists of a number of independently modulated subcarriers, which can give a large PAPR (Peak-to-Average Power Ratio) when added up coherently. In this paper, we investigate the performance of a simple PAPR reduction scheme, which requires no change of a receiver structure or no additional information transmission. The approach we employed is clipping in the time and frequency domains. The time-domain clipping is carried out with a predetermined clipping level while the frequency-domain clipping is done within EVM (Error Vector Magnitude). This approach is suboptimal with lower computational complexity compared to the optimal method. This evaluation is carried out on the OFDM system with an nonlinear amplifier. The simulation results demonstrated that the PAPR reduction algorithm is one of ways to reduce the effects of the nonlinear distortion of an HPA (High Power Amplifier).

New Decision Rules for UWB Synchronization (UWB 동기화를 위한 새로운 결정 법칙들)

  • Chong, Da-Hae;Lee, Young-Yoon;Ahn, Sang-Ho;Lee, Eui-Hyoung;Yoo, Seung-Hwan;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2C
    • /
    • pp.192-199
    • /
    • 2008
  • In ultra-wideband (UWB) systems, conventionally, the synchronization is to align time phases of a locally generated template and any of multipath components to within an allowable range. However, the synchronization with a low-power multipath component could incur significant performance degradation in receiver operation (e.g., detection) after the synchronization. On the other hand, the synchronization with a high-power multipath component can improve the performance in receiver operation after the synchronization. Generally, the first one among multipath components has the largest power. Thus, the synchronization with the first path component can make better performance than that with low-power component in receiver operation after the synchronization, Based on which, we first propose an optimal decision rule based on a maximum likelihood (ML) approach, and then, develope a simpler suboptimal decision rule for selecting the first path component. Simulation results show that the system has good demodulation performance, which uses new synchronization definition and the proposed decision rules have better performance than that of the conventional decision rule in UWB multipath channels. Between macroblocks in the previous and the current frame. On video samples with high motion and scene change cases, experimental results show that (1) the proposed algorithm adapts the encoded bitstream to limited channel capacity, while existing algorithms abruptly excess the limit bit rate; (2) the proposed algorithm improves picture quality with $0.4{\sim}0.9$dB in average.

Effect of Glycyrrhizae Radix on the Immune Responses(II) - Immuno-regulatory Action of Glycyrrhizin and Glycyrrhetinic Acid - (감초가 면역반응에 미치는 영향(II) - Glycyrrhizin 및 Glycyrrhetinic acid의 면역조절작용 -)

  • 한종현;오찬호;은재순
    • YAKHAK HOEJI
    • /
    • v.35 no.3
    • /
    • pp.174-181
    • /
    • 1991
  • These experiments were conducted to investigate the effects of glycyrrhizin(GL) and glycyrrhetinic acid(GA) on histamine synthesis, lymphocyte blastogenesis in C57BL/6J mice splenocytes, IL-1 production, $Ca^{2+}$ uptake by macrophage-like P388D$_{1}$ cells and plaque forming cell assay against SRBC. Histamine contents, lymphocyte blastogenesis, IL-1 activity, $Ca^{2+}$ uptake and plaque forming cell were determined by enzyme isotope method, [sup 3/H]-thymidine incorporation, C3H/HeJ mouse thymocytes proliferation, the addition of 5 $\mu$Ci/ml $^{45}$Ca$^{2+}$ to P388D$_{1}$, cell suspension and assay to sheep red blood cell, respectively. Cytotoxicity, which was expressed as 50% mortality, was occurred by the addition of GL(10$^{-3}$M) and GA(10$^{-4}$M). Histamine production in mouse spleen cell culture was significantly increased by the addition of 0.25 $\mu\textrm{g}$/ml of Con A, after 48 hour incubation. Con A dependent T-lymphocyte proliferation was also enhanced by the addition of 0.25 .mu.g/ml of Con A. The effects of GL on histamine contents and T-lymphocyte proliferation were significantly decreased at high dose (10$^{-5}$M), while IL-1 activity was remarkably suppressed by 10$^{-8}$~10$^{-4}$M of GL. $Ca^{2+}$ uptake was not changed, but antibody production was increased by GL(10 mg/kg). GA inhibited histamine contents at 10$^{-9}$~10$^{-7}$ and depressed Con A (0.25 $\mu\textrm{g}$/ml) dependent T-lymphocyte proliferation at 10$^{-7}$~10$^{-5}$M of GA, but increased suboptimal dose (Con A 0.1 $\mu\textrm{g}$/ml) at 10$^{-9}$~10$^{-7}$M of GA. IL-1 activity was suppressed by 10$^{-8}$~10$^{-4}$M of GA and $Ca^{2+}$ uptake was enhanced by 10$^{-9}$~10$^{-6}$ of GA, but antibody production was not changed by GA. From the above results, it is suggested that GL and GA have immuno-regulatory action. GL decreased cell-mediated immune response, and increased humoral immune response at high dose. On the other hand, low dose of GA enhanced cell-mediated immune response, while high doses of GA decreased humoral immune reaction.

  • PDF

Design of an Optimal Adaptive Filter for the Cancellation of M-wave in the EMG Controlled Functional Electrical Stimulation for Paralyzed Individuals (마비환자의 근전도제에기능적전기자극을 위한 M-wave 제거용 최적적응필터 설계)

  • Yeom Hojoon;Park Youngcheol;Lee Younghee;Yoon Youngro;Shin Taemin;Yoon Hyoungro
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.479-487
    • /
    • 2004
  • Biopotential signals have been used as command in systems using electrical stimulation of motor nerves to restore movement after an injury to the central nervous system (CNS). In order to use the voluntary EMG (electromyography) among the biopotentials as a control signal for the electrical stimulation of the same muscle for CNS injury patients, it is necessary to remove M-wave of having high magnitude from raw data. We designed an optimal filter for removing the M-wave and preserving the voluntary EMG and showed that the optimal filter is eigen filter. We also proved that the previous method using the prediction error filter(PEF) is a suboptimal filtering in the sense of preserving the voluntary EMG. On basis of the data obtained from a model for M-wave and voluntary EMG and from actual CNS injury patients, with false-positive rate analysis, the proposed adaptive filter showed a very promising performance in comparison with previous method.

Incidence of Paresthesia Related to the Insertion Length of Catheter during the Epidural Catheterization (경막외강 카테터 삽입 시 삽입 길이와 감각이상의 빈도)

  • Lim, Jun Goo;Kim, Young Jae;Cho, Jae Heung;Lee, Sang Eun;Kim, Young Hwan;Lim, Se Hoon;Lee, Jeong Han;Lee, Kun Moo;Cheong, Soon Ho;Choi, Young Kyun;Shin, Chee Mahn
    • The Korean Journal of Pain
    • /
    • v.20 no.1
    • /
    • pp.50-53
    • /
    • 2007
  • Background: Continuous epidural catheterization is a popular and effective procedure for postoperative analgesia. However, continuous epidural catheterization has associated complications such as venous puncture, dural puncture, subarachnoid cannulation, suboptimal catheter placement, and paresthesia because the tip of the epidural catheter touches thenerves of the dura in the epidural space. In this study, we compared the incidence of paresthesia in two different lengths of epidural catheter insertion. Methods: One hundred women undergoing gynecologic or orthopedic surgery were enrolled in this prospective, double-blinded, randomized study. All patients were randomly divided into two groups based on the insertion length of the epidural catheter 2 cm (group A) or 4 cm (group B). A Tuohy needle was inserted in the lumbarspinal region with a bevel directed cephalad by use of the median approach, and then the epidural space was confirmed by the loss of resistance technique with air. While the practitioner inserted an epidural catheter into the epidural space, a blind observer checked for paresthesia or withdrawal movement. Results: In 97 included patients, 30.6% of the patients in group A (n = 49) had paresthesia, versus 31.3% in group B (n = 48). Withdrawal movements were represented in 2% and 6% of the patients in group A and group B, respectively. There was no difference in the incidence of paresthesia and withdrawal movement between the two groups. Conclusions: There is no clear relationship for the incidence of catheter-related paresthesia according to the catheter length inserted into the epidural space for epidural analgesia.

A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province (조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 -)

  • Yang, Jeong-Hwa;Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.63-69
    • /
    • 2006
  • In diagnostic ultrasound, the quality of image affect to diagnose. To maintain suboptimal imaging uniformly, Quality Assurance of Ultrasound equipment should take periodically. This is article about examination the quality of image in diagnostic ultrasound to understand conditions of probes in hospitals. There is comparative study of convex and linear probes on ultrasound using tissue-mimicking phantom included simulated cysts, echogenic structures. The ultrasonic attenuation coefficient versus frequency of 0.5 dB is representative of normal liver and 0.7 dB is representative of fatty liver condition in ultrasound phantom. There are results of convex probe, 0.5 dB, vertical group, cystic masses, high contrast masses are mostly shown but 0.7 dB, mid level in vertical group, cystic masses and high contrast masses are nearly visible. In linear probe, 0.5 dB, mid level in vertical group, two or four of them are shown in cystic masses and high contrast masses but there are not visible in 11 of cases. 0.7 dB, there are mostly appear under 6 in vertical group, two or four of them show in cystic masses and high contrast masses and there are not shown in 40 of cases, besides. Linear probes in fatty liver condition of ultrasound instrument are not good in the quality of image practically. So there needs to be replace and fix of probes. Actually management of ultrasound probes is inadequate in hospitals. So if there are program of evaluation to check probes periodically in hospitals from establishment of the ultrasound equipment, there will get better image and have a suitable condition of instruments further more.

  • PDF

Study on the Evaluation of Ecological Health by using Fish Communities in the Wonju Stream, Korea (원주천의 어류군집을 이용한 생태적 건강성 평가 연구)

  • Park, Hyun Kyung;Choi, Jun Kil;Won, Kyung Ho;Lee, Hwang Goo
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.684-693
    • /
    • 2017
  • The purpose of this study was to analyze fish communities in the Wonju stream located in Wonju-si in Gangwon-do, and to evaluate the health of the stream through past and present changes. We performed investigations four times from May 2015 to September 2016. In the survey, 5,201 individuals which belonged to 27 species and 9 families were collected. Zacco platypus was the dominant species and Pungtungia herziwas the subdominant species. Eight Korean endemic species (Acanthorhodeus gracilis, Zacco koreanus, Coreoleuciscus splendidus, Squalidus gracilis majimae, Microphysogobio yaluensis, Iksookimia koreensis, Koreocobitis rotundicaudata, Coreoperca herzi) were observed and showed a ratio of 16.54%. The fish community of dominance ($0.72{\pm}0.10$), diversity ($1.37{\pm}0.32$), evenness ($0.61{\pm}0.13$), and richness ($1.70{\pm}0.23$) were evaluated. According to our analysis of tolerance guilds, the total individual number of intermediate species was higher than the sensitive and tolerant species. As a result of the trophic guild analysis,the omnivore and insectivore species were relatively high. The value of the qualitative habitat evaluation index (QHEI) in the wonju stream was averaged 121.2 (${\pm}23.4$), indicating a suboptimal condition. Stream health showed that the fish assessment index (FAI) value was an A to C grade in the Wonju stream. A correlation coefficient analysis with FAI and various factors was analysed statistically, and had a high correlation in QHEI, with the omnivore species, insectivore species, intermediate species, sensitive species, dominance, diversity, evenness, and richness.

Adjustable Ghajar Guide Technique for Accurate Placement of Ventricular Catheters : A Pilot Study

  • Yoon, Sang-Youl;Kwak, Youngseok;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.604-609
    • /
    • 2017
  • Objective : An adjustable Ghajar guide is presented to improve the accuracy of the original Ghajar guide technique. The accuracy of the adjustable Ghajar guide technique is also investigated. Methods : The coronal adjustment angle from the orthogonal catheter trajectory at Kocher's point is determined based on coronal head images using an electronic picture archiving and communication system. For the adjustable Ghajar guide, a protractor is mounted on a C-shaped basal plate that is placed in contact with the margin of a burrhole, keeping the central $0^{\circ}$ line of the protractor orthogonal to the calvarial surface. A catheter guide, which is moved along the protractor and fixed at the pre-determined adjustment angle, is then used to guide the ventricular catheter into the frontal horn adjacent to the foramen of Monro. The adjustable Ghajar guide technique was applied to 20 patients, while a freehand technique based on the surface anatomy of the head was applied to another 47 patients. The accuracy of the ventricular catheter placement was then evaluated using postoperative computed tomography scans. Results : For the adjustable Ghajar guide technique (AGT) patients, the bicaudate index ranged from 0.23 to 0.33 ($mean{\pm}standard$ deviation [SD] : $0.27{\pm}0.03$) and the adjustment angle ranged from $0^{\circ}$ to $10^{\circ}$ ($mean{\pm}SD:5.2^{\circ}{\pm}3.2^{\circ}$). All the AGT patients experienced successful cerebrospinal fluid diversion with only one pass of the catheter. Optimal placement of the ventricular catheter in the ipsilateral frontal horn approximating the foramen of Monro (grade 1) was achieved in 19 patients (95.0%), while a suboptimal trajectory into a lateral corner of the frontal horn passing along a lateral wall of the frontal horn (grade 3) occurred in 1 patient (5.0%). Thus, the AGT patients experienced a significantly higher incidence of optimal catheter placement than the freehand catheterized patients (95.0% vs. 68.3%, p=0.024). Moreover, none of the AGT patients experienced any tract hemorrhages along the catheter or procedure-related complications. Conclusion : The proposed adjustable Ghajar guide technique, using angular adjustment in the coronal plane from the orthogonal trajectory at Kocher's point, facilitates accurate freehand placement of a ventricular catheter for hydrocephalic patients.