• Title/Summary/Keyword: Subjective wearing comfort

Search Result 82, Processing Time 0.022 seconds

Physiological Response & Comfort according to Backpack Type and Weight for Girl Middle School Students (여중생 책가방의 형태와 무게에 따른 생리적 반응과 쾌적감)

  • Park, Hae-Young;Lee, Kyung-A;Na, Young-Joo
    • Fashion & Textile Research Journal
    • /
    • v.12 no.3
    • /
    • pp.364-371
    • /
    • 2010
  • The purpose of this study is to weigh the students' backpacks of middle school in daily use and to analyse their physiological responses and subjective senses when carrying backpack in order to promote healthy and comfort school life of girl middle school students. Two female students were subjects who answered the questionnaires on two types of backpack and their metabolism, perspiration and the changes of skin temperature were measured in constant environment chamber, $25{\pm}1$ and $49{\pm}10$% RH. They walked on the treadmill carrying the backpack with the increment of backpack weight, 2 kg, 4 kg to 6 kg. When the backpack increases to 6 kg, the discomfort parameters and responses increases rapidly. Comparing with general type, improved type of backpack showed good results in physiological responses, but not in subjective senses, such as the ease of movement, pain, or total preference, specially in 2 kg and 4 kg. The girl students prefer the general type of backpack which is of fashion and small, when it weighs light such as 2 kg or 4 kg, while they prefer the improved bag which is functional when it is heavy as 6 kg. The longer wearing time of the medium weight, for example, 4 kg without feeling or recognition of any discomfort due to fashion style, might cause the students' posture and health weaker or more vulnerable to the problems.

Assessment of Subjective Sensation and Purchasing Preferences for Casual Shirt Fabrics (캐주얼 셔츠소재에 대한 주관적 감각과 구매 선호도 평가)

  • Choi, Jong-Myoung;Kweon, Soo-Ae
    • Korean Journal of Human Ecology
    • /
    • v.15 no.3
    • /
    • pp.397-404
    • /
    • 2006
  • The purpose of this study is to analyze the subjective sensations and preference for spring/fall casual cotton shirt fabrics, and to assist in developing shirt fabrics that offer maximum comfort in wearing sensation. The subjects of this study were male and female college students who assessed the tactile sensation of seven types of spring/fall shirt fabrics available on the market: plain weave and rib weave made of cotton and that of cotton mixed fabrics. The subjects were university students between the ages of 20 to 23, who were residing in the city of Cheongju, Korea. The questionnaires related to the fabrics hand were evaluated using a nine point bi-polar scale of 9 descriptive terms. Mean, t-test, F-test and $X^2$ were used for data analysis. The fabric hand evaluation on the seven types of shirts showed a significant difference in all of the 9 descriptive terms. There were partially significant differences in the subjective sensations according to fabric characteristics regarding shirt fabrics. As regards the difference in fabric hand according to gender, female students responded with more receptiveness and sensitivity than male students in the category of woven fabric evaluation. In particular, female students responded with more sensitivity to the sensation of dense and wrinkle sensations. There were significant differences in the purchase preference according to gender regarding casual shirt fabrics. Plain weave fabrics made of cotton was most preferred among male students, whereas rib weave fabrics made of cotton/polyester was most preferred among female students.

  • PDF

The Physiological Responses of Material-improved Working Clothes for Construction Site Worker (건설현장 작업복의 소재 기능성 향상에 따른 생리반응)

  • Kim, Seong-Suk;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.752-758
    • /
    • 2011
  • In this paper, experiments to develop working clothes and evaluated, including the current and material-improved working clothes in relation to physiological functionality measurement. Experiments were conducted on subjects after wearing working clothes in an climate chamber, and the thermo-physiological response, such as human body temperature, micro-climate within the clothes, blood pressure, heart rate were measured. In this manner, the physiological functionality of improved working clothes was compared with that of current working clothes and evaluated. The summary of obtained results is as follows: For physiological functionality evaluation through material-improved working clothes, P working clothes showed significantly lower rectal temperature than C working clothes. For mean skin temperature, P's skin temperature was significantly higher than C's in the second half of the experiment. P working clothes's temperature around the thighs in Micro climate was significantly lower than that of the C working clothes. Also, humidity within the clothes showed similar trends. During the exercise period, C working clothes showed higher blood pressure than P, but P showed higher heart rates than C. Also, the oxygen uptake amount was higher in C than P during the exercise period, it explains that the energy consumption amount of P working clothes was smaller than that of C working clothes. Of the subjective evaluation, for temperature sensation, workers wearing P working clothes felt cooler. For humidity, C working clothes showed more humidity. For comfort, P working clothes were better, and for sense of fatigue, workers felt less tired wearing P working clothes. From results above, we can see that physiological functionality improved in the material-improved working clothes in the working clothes for construction site workers. The improvement of working clothes through functionality improvements not only will provide personal pleasantness to constriction site workers, but will also generate efficiency and productivity improvements at construction sites. All in all, the continuous study of functionality improvements in working clothes taking into consideration the human body's physiological responses is required.

The Improvement and Evaluation of the Flight Suit Pattern to Enhance Movement (동작성 향상을 위한 비행복의 패턴개선 및 평가)

  • Jeon, Eun-Jin;Park, Sei-Kwon;You, Hee-Cheon;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.12 no.5
    • /
    • pp.633-641
    • /
    • 2010
  • The purpose of this study is to evaluate a new flight suit in bilateral ways; subjectively and objectively in the improvements of comfort and mobility. Seven healthy males at the age of twenties volunteered in this wearing test. They were over 177 cm in height and 92-95 cm in chest circumference, which satisfies the M95 Special' size described in the Korean Military Specifications and Standards. The subjective satisfaction was evaluated according to the criteria of ease of donning and doffing, fitness of wear, mobility, space between cloth and body, convenience in using restroom. Subjective satisfaction evaluation says that the best improvement of movement are neck circumference, chest breadth, armscye circumference, waist back length, crotch length, crotch height and body rise. According to the evaluation, improvements of mobility were conspicuous especially in parts of body like neck, breast, waist, back, and arms. When evaluating objective satisfaction, we measured a angle difference in a prescribed standard-grid on a photograph that picked up while the subject performed each motion in front of 10 cm-interval grid. As a result, the motion that had angle difference above 5 degrees were arm stretching and standing on single leg holding at forward or at his side. Bending necks and waist, crouching also had angle difference of over 5 degrees. The improvements are discussed from the viewpoint that the increased ease in parts of armscye circumference and crotch in new flight suit pattern.

The Physiological Responses and Subjective Sensation in the Subjects Wearing Dust-free Garment for Semiconductor Industrial Environments (방진복 착용에 따른 인체의 온열생리적 특성 및 주관적 감각)

  • 권오경;이창미
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.255-263
    • /
    • 1998
  • Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.

  • PDF

Subjective Symptoms according to Fitting Test in Soft Contact Lens Wearers (소프트콘택트렌즈 착용자의 피팅 상태 확인 유무에 따른 자각적 증상)

  • Kim, Jung-Hee;An, Youngju
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.431-442
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate subjective symptoms according to the wearing, purchase and fitting status of soft contact lens wearers, and consumer perception of base curve. Methods : A survey was conducted for those who visited optical shops and lens shops in Seoul from June to August 2018. A total of 98 answer sheets they submitted were used for the analysis. The chi-square test and Fisher's exact test were used to compare subjective symptoms (dryness, glare, uncomfortable fitting, and decreased vision) according to whether fitting condition is screened (case history and push-up test, ect relevant to wearing sensation), and the odds ratio (OR) was obtained by the logistic regression analysis. Results : When the contact lenses were purchased, the rate of which the visual acuity test was performed was 86.6% at optical shop and 64.7% at lens shop. When purchasing contact lens and the contact lens was not tested for fitting, they more experienced dryness (OR 4.41, 95% CI 1.25-15.62) and uncomfortable fitting (OR 2.68, 95% CI 1.08-6.64) than testing for fitting. In addition, it was investigated that 87.8% of contact lens wearers did not know about the term base curve, 92.9% did not listen to an explanation related to the base curve when purchasing contact lenses, and 96.9% did not experience with base curve test. Conclusion : It would be thought that satisfaction of the contact lens fitting of existing consumers should be improved by changing a proper base curve by confirming the fitting condition when prescribing soft contact lens.

Applying QFD in the Development of Sensible Brassiere for Middle Aged Women (QFD(품질 기능 전개도)를 이용한 중년 여성의 감성 Brassiere 개발)

  • Kim Jeong-hwa;Hong Kyung-hi;Scheurell Diane M.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.12 s.138
    • /
    • pp.1596-1604
    • /
    • 2004
  • Quality Function Deployment(QFD) is a product development tool which ensures that the voice of the customer needs is heard and translated into products. To develop a sensible brassiere for middle-aged women QFD was adopted. In this study the applicability and usefulness of QFD was examined through the engineering design process for a sensible brassiere for middle-aged women. The customer needs for the wear comfort of brassiere was made by one-on-one survey of 100 women who aged 30-40. The customer competitive assessment was generated by wearing tests of 10 commercial brassieres. The subjective assessment was conducted in the enviornmental chamber that was controlled at $28{\pm}1^{\circ}C,\;65{\pm}3\%RH.$ As a results, we developed twenty-one customer needs and corresponding HOWs for the wear comfort of brassiere. The Customer Competitive Assessment was generated by wearing tests of commercial brassiere. The subjective measurement scale and dimension for the evaluation of sensible brassiere were extracted from factor analysis. Four factors were fitting, aesthetic property, pressure sensation, displacement of brassiere due to movement. The most critical design parameter was wire-related property and second one was stretchability of main material of brassiere. Also, wearing comfort of brassiere was affected by the interaction of initial stretchability of wing and support of strap. Engineering design process, QFD was applicable to the development of technical and aesthetic brassieres.

Inferring Pedestrians' Emotional States through Physiological Responses to Measure Subjective Walkability Indices

  • Kim, Taeeun;Lee, Meesung;Hwang, Sungjoo
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1245-1246
    • /
    • 2022
  • Walkability is an indicator of how much pedestrians are willing to walk and how well a walking environment is created. As walking can promote pedestrians' mental and physical health, there has been increasing focus on improving walkability in different ways. Thus, plenty of research has been undertaken to measure walkability. When measuring walkability, there are many objective and subjective variables. Subjective variables include a feeling of safety, pleasure, or comfort, which can significantly affect perceived walkability. However, these subjective factors are difficult to measure by making the walkability index more reliant on objective and physical factors. Because many subjective variables are associated with human emotional states, understanding pedestrians' emotional states provides an opportunity to measure the subjective walkability variables more quantitatively. Pedestrians' emotions can be examined through surveys, but there are social and economic difficulties involved when conducting surveys. Recently, an increasing number of studies have employed physiological data to measure pedestrians' stress responses when navigating unpleasant environmental barriers on their walking paths. However, studies investigating the emotional states of pedestrians in the walking environment, including assessing their positive emotions felt, such as pleasure, have rarely been conducted. Using wearable devices, this study examined the various emotional states of pedestrians affected by the walking environment. Specifically, this study aimed to demonstrate the feasibility of monitoring biometric data, such as electrodermal activity (EDA) and heart rate variability (HRV), using wearable devices as an indicator of pedestrians' emotional states-both pleasant-unpleasant and aroused-relaxed states. To this end, various walking environments with different characteristics were set up to collect and analyze the pedestrians' biometric data. Subsequently, the subjects wearing the wearable devices were allowed to walk on the experimental paths as usual. After the experiment, the valence (i.e., pleasant or unpleasant) and arousal (i.e., activated or relaxed) scale of the pedestrians was identified through a bipolar dimension survey. The survey results were compared with many potentially relevant EDA and HRV signal features. The research results revealed the potential for physiological responses to indicate the pedestrians' emotional states, but further investigation is warranted. The research results were expected to provide a method to measure the subjective factors of walkability by measuring emotions and monitoring pedestrians' positive or negative feelings when walking to improve the walking environment. However, due to the lack of samples and other internal and external factors influencing emotions (which need to be studied further), it cannot be comprehensively concluded that the pedestrians' emotional states were affected by the walking environment.

  • PDF

Evaluation of Physiological Responses and Comfort of Protective Clothing Using Charcoal Printing (숯 날염가공한 방호복의 인체생리반응 및 쾌적성 평가)

  • Chung Myung-Hee;Park Soon-Ja;Shin Jung-Sook;Koshiba Tomoko;Tamura Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.6 s.154
    • /
    • pp.981-991
    • /
    • 2006
  • The purpose of this study was to determine the practicability of an experimental protective clothing by identifying the human body's physiological responses to it as well as the human body's comfort level when wearing it, particularly with the use of a processed charcoal material. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric; and one whose inner side made use of a non-woven fabric processed with charcoal with a 10% density. Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climatic chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively, and were measured within a period of 60min, consisting of a 20-min rest period, a 20-min exercise period, and a 20-min recovery period. Based on the results of this study, the efficiency of the processed charcoal material was reviewed, and a database requiring the production of more functional and comfortable protective clothing materials was established.

Evaluation of Wearing Comfort and Ease of Working Pants for Improved Mobility (동작가동성이 향상된 작업복 하의 개발을 위한 시판 제품의 착용감 및 여유량 평가)

  • Lee, Hyojeong;Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.4
    • /
    • pp.752-770
    • /
    • 2017
  • This study provides a size specification and ease for the development of pants for working clothes in the construction industry according to season. We collected and measured the size specification of 4 types of Spring/Fall pants, 4 types of winter brushed bonding pants, and 4 types of winter padded pants. Subjective comfort evaluation and analysis of ease sensation were performed for all products on 12 subjects. The average size specifications for the pants according to seasons were as follows. Spring/Fall pants had 74.0/80.0cm waist size (relaxed/maximum stretched) and 104.0cm hip size. Winter brushed bonding pants had 76.0/83.4cm for waist size and 106.0cm for hip size. Winter padded pants had 71.5/84.0cm for waist size and 112.8cm for hip size. When designing a pattern by comparing product size specification and subject body size, the recommended ease is 0.2/7.2cm for waist size (relaxed, maximum stretched) and 13.6cm for hip size for Spring/Fall pants, and 0.2/6.2cm for waist size and 11.6cm for hip size of winter brushed bonding pants, and -5.3/7.2cm for waist size and 19.4cm for the hip size of winter padded pants.