Heating Performance Characteristics of a Heat Pump with a Variable Speed Injection Scroll Compressor (인젝션형 가변속 스크롤 압축기를 적용한 히트펌프의 난방성능 특성에 관한 연구)

  • Ko, Suk-Bin;Heo, Jae-Hyeok;Cho, Il-Yong;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.377-384
    • /
    • 2012
  • Vapor injection technique has been applied to prevent performance degrdation of a heat pump at low ambient temperatures. In this study, the heating performance of a heat pump with a variable speed injection scroll compressor using R-410A was investigated by applying sub-cooler vapor injection(SCVI) and flash tank vapor injection(FTVI). The heating performance of the heat pump was measured by varying compressor frequency and outdoor temperature. The heating capacity of the FTVI system was 8~10% higher than that of the SCVI system at all operating conditions. On the other hand, the heating performance improvement with the increase in the compressor frequency was more prominent in the SCVI system than in the FTVI system.

The Search for Binaries in Post-Asymptotic Giant Branch Stars: Do Binary Companions Shape the Nebulae?

  • Hrivnak, Bruce J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Binary companions are often invoked to explain the axial and point symmetry seen in the majority of planetary nebulae and proto-planetary nebulae (PPNs). To explore this hypothesis, we have undertaken a long-term (20 year) study of light and velocity variations in PPNs. From the photometric study of 24 PPNs, we find that all vary in brightness, and from a subset of 12 carbon-rich PPNs of F-G spectral type we find periods of 35-155 days, with the cooler having the longer periods. The variations are seen to be due to pulsation; no photometric evidence for binarity is seen. A radial velocity study of a sub-sample of seven of the brightest of these shows that they all vary with the pulsation periods. Only one shows evidence of a longer-term variation that we tentatively identify as being due to a binary companion. We conclude that the present evidence for the binary nature of these PPNs is meager and that any undetected companions of these PPNs must be of low mass (< 0.25 $M_{\odot}$) or long period (> 30 years).

Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop (하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석)

  • Park, Young-Chul;Lee, Yong-Sub;Chi, Dae-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.7-12
    • /
    • 2009
  • A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

Prediction of Adiabatic Capillary Tube Length of Heat Pump Using Carbon Dioxide (CO2 히트펌프용 단열 모세관 길이 예측에 관한 연구)

  • Oh, Hoo-Kyu;Choi, Kwang-Hwan;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.576-581
    • /
    • 2011
  • In this paper, the prediction of adiabatic capillary tube of heat pump using carbon dioxide is investigated theoretically and experimentally to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include evaporation temperature, cooling pressure of gas cooler, mass flowrate, and the length and diameter of capillary tube. Based on study results of several researchers, the correlation predicting the length of capillary tube of $CO_2$ heat pump was proposed. And the experimental results of evaporation temperature, mass flowrate and cooling pressure in adiabatic capillary tube have an good agreement to those calculated from Eq. (3) within 0.63~10.9%. Therefore, the prediction calculating the length of adiabatic capillary tube of $CO_2$ heat pump was proposed at the given conditions such as cooling pressure, evaporation temperature and capillary tube diameter.

Current status and prospects for in-feed antibiotics in the different stages of pork production - A review

  • Li, Junyou
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.12
    • /
    • pp.1667-1673
    • /
    • 2017
  • Antibiotics have long been of great benefit for people, both in the medical treatment of human disease and in animal food where they improve the growth performance and feed utilization during animal production. Antibiotics as in-feed supplements affect all stages of pork production, including the gestation, nursing, growing, and finishing stages, although the effects show stage-dependent differences. However, the use of antibiotics in animal feed has become a worldwide concern. This review describes why sub-therapeutic levels of antibiotic additives in animal feed have become an integral part of animal feeding programs for more than 70 years, particularly in pork production. It also discusses the threat of the long-term use of sub-therapeutic levels of antibiotics in pork production. In recent years, the effectiveness of in-feed antibiotics has tended to decrease. This review analyzes this change from various perspectives. First, the equipment used at pig farms has improved dramatically and is more sanitary. Worldwide, more pig farms use pig farrowing crates, gestation crates, piglet nursery crates, flooring devices, piggery ventilation and cooler systems, automatic pig feeders, piggery heating equipment, and artificial insemination systems. In addition, scientists have replaced the use of antibiotics with organic acids, fermented mash, probiotics, prebiotics, minerals, oligosaccharides, enzymes, herbs/flavors, and protein/amino acids, and have improved management and husbandry techniques. In addition, animal welfare legislation has been aimed at improving the quality of the floors and living space, ensuring that animals have permanent access to fresh water, and setting a minimum weaning age. Finally, the prospects and the possibility of replacing antibiotics in pork production are described, in line with recent research results.

Vibration characteristics of an ultrasonic waveguide for cooling (냉각용 초음파 웨이브가이드의 진동 특성)

  • Kim, Hyunse;Lim, Euisu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.6
    • /
    • pp.568-575
    • /
    • 2020
  • Ultrasound has been widely used in various industrial fields. One of challenging application areas is cooling microelectronics. Ultrasonic cooling systems can work with air, argon (Ar) and nitrogen (N2) instead of conventional refrigerant such as freon gas, which can cause global warming. Furthermore, ultrasonic systems do not have moving parts, thus high durability can be obtained. So it is necessary to develop ultrasonic cooling systems due to environmental issues and durability points. In this paper, the design and fabrication processes are explained. When designing the system, a feasibility test was performed with a prototype cooler. Based on the result, finite element analysis with ANSYS software was performed. The predicted anti-resonance frequency for a piezoelectric actuator was 34.8 kHz, which was in good agreement with the experimental result of 34.6 kHz with 0.6% error. In addition, the predicted anti-resonance frequency for the ultrasonic waveguide was 39.4 kHz, which also agreed well with the experimental value of 39.8 kHz with 1.0% error. Based on these results, the developed ultrasonic waveguide might be applicable in microchip cooling.

Occurrence and Geochemistry of Argyrodite, a Germanium-Bearing Mineral(Ag8GeS6), from the Weolyu Ag-Au Hydrothermal Vein Deposits (월류(月留) 은(銀)-금(金) 열수광상(熱水鑛床)에서 산출된 함(含) Ge 광물(鑛物)인 Argyrodite의 산상(産狀)과 지구화학(地球化學))

  • So, Chil-Sup;Yun, Seong-Taek;Choi, Seon-Gyu
    • Economic and Environmental Geology
    • /
    • v.26 no.2
    • /
    • pp.117-127
    • /
    • 1993
  • Ag-Au vein ores from the Weolyu mine, Youngdong district, contain significant germanium (up to 145g/t, average 34.9g/t), in the form of argyrodite ($Ag_8GeS_6$). Mineral chemistries of argyrodite and its associated minerals were determined by electron probe microanalysis. Twenty eight elements in thirteen ore samples were analyzed using an ICP mass spectrometer. Argyrodite occurs in the paragenetically later mineral assemblage consisting of carbonates+quartz+native silver+argentite+Ag-sulfosalts, indicating that the germanium mineralization represents the culmination of a complex mineral sequence which includes early gold and late silver deposition. The mean formula of the argyrodite is $Ag_{7.90}\;(Ge_{0.76}Sn_{0.04})S_6$, with minor amounts of Cu, Fe, Sb, As, Sn, and Zn. The Weolyu argyrodite shows systematic substitutions of Ag by Cu, and of Ge by Sb. Chemical analyses of vein ores indicate that metals were precipitated in the order of $Fe{\rightarrow}Pb$, $Zn{\rightarrow}Cu{\rightarrow}Ag$, Sb, As, Ge. Germanium has a strong geochemical affmity with As and Sb, and Cu, Pb, Zn, Mo, and Sr show weak positive correlations with Ge. Germanium deposition at Weolyu was mainly a result of cooling of hydrothermal fluids (down to $175^{\circ}C{\sim}210^{\circ}C$, due to increasing involvement of cooler meteoric waters in the epithermal system.

  • PDF

Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application (배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발)

  • Park, Dong-Keun;Seok, Bok-Yeol;Ko, Tae-Kuk;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

Report on Forests Damaged Due to Cutting Trees Infected by Pine Wilt Disease (소나무재선충 고사목 제거에 따른 산림훼손 보고)

  • Hong, Suk-Hwan;Lee, Soo-Dong
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.4
    • /
    • pp.590-598
    • /
    • 2015
  • Despite various control methods for pine wilt disease, the disease has been increasing at an alarming rate every year in Korea. Still there is a lack of research on the problems of the current methods used to curb the disease. One main method to control pine wilt disease is fumigation for eliminating the larva of the pine sawyer beetle (Monochamus alternatus) which is known as the vector insect for pine wilt disease. We surveyed and analyzed the amount of destroyed uninfected trees in the fumigated area by studying 32 survey plots ($100m^2$) in Miryang city. The destroyed trees' crown area was estimated by induced regression between root collar area and crown area of the remaining trees (coniferous tree: $R^2=57.4$, deciduous broad-leaved tree: $R^2=63.8$). According to the analysis results, the infected trees (cut trees) were 18.7% and cut trees which were not infected were 35.5% of the total tree population of the study area on the basis of total crown area. In case of pine trees, 8.4% of uninfected trees were cut off but 62% of uninfected deciduous broad-leaved trees including Quercus spp. were affected and damaged during the fumigation process. Since these broad-leaved trees dominate the sub-canopy layer of the forest, this indiscriminate interruption of broad-leaved trees has the adverse effect of depriving the public benefits such as shadow, a cooler weather, controlling humidity, etc.