• Title/Summary/Keyword: Sub-Elements

Search Result 1,188, Processing Time 0.028 seconds

ON THE DIGITS OF NUMBERS IN THE SYSTEM LOGIC B3

  • HASAN KELES
    • Journal of Applied and Pure Mathematics
    • /
    • v.6 no.1_2
    • /
    • pp.97-103
    • /
    • 2024
  • This study is about digits of numbers in system logic B3. Any real number is written as digits in the binary system, in the ternary system. The numbers in base two and base three are also written in the B3 system ternary logic. These two writing methods are transferred into the third method. The real numbers 0,1 and 0, 1, 2 are written as digits. The same real numbers are written as digits of elements of the set -1, 0, 1 in base B3. The periods here are investigated. The relationship between these digits is analysed.

PM10 Concentration and Chemical Composition in Western Area of Busan (부산 서부지역의 대기 중 PM10 농도와 화학적 조성 분석)

  • 황용식;전병일
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.627-633
    • /
    • 2003
  • The PM$_{10}$ concentration and chemical composition in an western area of Busan were surveyed between March, 2001 and February, 2002. The mean concentration was 98.2 $\mu\textrm{g}$/㎥ with a range of 18.1 to 330.6 $\mu\textrm{g}$/㎥. The magnitude of metallic elements in PM$_{10}$ is as follows in decreasing order: K>Ca>Na>Al>Fe. The mean values of crustal enrichment factors for four elements (Cd, Ni, Pb and Zn) were all higher than 10, which presumably resulted from the effect of anthropogenic origin. Moreover, the wintertime values were higher than springtime and summertime values, possibly due to emissions westerly transported from industries around this area. The contribution of soil particle to airborne particle in the study area was estimated to be 9.5%.

Ionic and Elemental Compositions of PM2.5 at the 1,100 m-Highland of Mt. Hallasan in Jeju Island (한라산 1,100 m 지역의 대기 중 PM2.5에 함유된 이온 및 원소 성분의 조성특성)

  • Lee, Ki-Ho;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.865-875
    • /
    • 2016
  • In this study, mass concentrations and chemical compositions of $PM_{2.5}$, including water-soluble ions and elements were determined at the 1,100 m-highland of Mt. Hallasan in Jeju Island across four seasons from August 2013 to August 2014. The average mass concentration of $PM_{2.5}$ was $12.5{\pm}8.41{\mu}g/m^3$ with 45.8% of the contribution from eight water-soluble ionic species. Three ionic species ($SO{_4}^{2-}$, $NH{_4}^+$, and $NO{_3}^-$) comprised 96.2% of the total concentration of ions contained in $PM_{2.5}$ and were the dominant ions, accounting for 43.5% of the $PM_{2.5}$ mass at Mt. Hallasan. On the basis of the mass concentration level, seasonal variation, enrichment factor, and relationship among elements, we can presume that Mg, K, Ca, Mn, Fe, Co, Sr, Ba, Nd, and Dy originated mainly from crust or soil and that V, Cr, Ni, Cu, Zn, As, Cd, and Pb were significantly enriched in $PM_{2.5}$ owing to the effects of the anthropogenic emissions. These results and the local distribution of emission sources and topographic characteristics near this sampling site suggest that the compositions of $PM_{2.5}$ collected at the 1100 m-highland of Mt. Hallasan were largely influenced by inflow from outside of Jeju Island.

A Study on the Requisite Elements of LCCO2 Evaluation System at Planning Stage of Building (건축물 계획단계 LCCO2 평가시스템의 필요요소에 관한 연구)

  • Baek, Cheong-Hoon;Tae, Sung-Ho;Roh, Seung-Jun;Lee, Joo-Ho;Shin, Sung-Woo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.3
    • /
    • pp.31-41
    • /
    • 2011
  • The $LCCO_2$ evaluation programs previously developed in Korea involve limitations in establishing strategies of reducing environmental loads to optimal level in a way to put in materials directly after designing. Therefore, this study has the purpose to extract and propose elements required for the establishment of highly accurate system by counteracting swiftly in a method with high energy efficiency over cost at planning stage. To that end, existing $LCCO_2$ evaluation programs in Korea and abroad were compared and analyzed, and in the planning stage, GEM-21P and Carbon-navigator intended for the establishment of building energy performance improving strategy were selected as the evaluation program for survey. On such basis, after comparison and analysis between $LCCO_2$ calculating methods and system structures of the two programs, elements required for system establishment that can evaluate life-cycle environmental loads of building in planning stage were proposed.

Impact of Dust Transported from China on Air Quality in Korea -Characteristics of PM2.5 Concentrations and Metallic Elements in Asan and Seoul, Korea

  • Yang, Won-Ho;Son, Bu-Soon;Breysse, Patrick;Chung, Tae-Woong
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.6
    • /
    • pp.479-487
    • /
    • 2007
  • [ $PM_{2.5}$ ], particulate matter less than 2.5 um in a diameter, can penetrate deeply into the lungs. Exposure to $PM_{2.5}$ has been associated with increased hospital visits for respiratory aliments as well as increase mortality. $PM_{2.5}$ is a byproduct of combustion processes and as such has a complex composition including a variety of metallic elements, inorganic and organic compounds as well as biogenic materials (microorganisms, proteins, etc). In this study, the average concentrations of fine particulates $PM_{2.5}$ have been measured simultaneously in Asan and Seoul, Korea, by using particulate matter portable sampler from September 2001 to August 2002. Sample collection filters were analyzed by ICP-OES to determine the concentrations of metallic elements (As, Ni, Fe, Cr, Cd, Cu, Pb, Zn, Si). Annual mean $PM_{2.5}$ concentrations in Asan and Seoul were 37.70 and $45.83\;{\mu}g/m^3$, respectively. The highest concentrations of $PM_{2.5}$ were found in spring season in both cities and the concentrations of measured metallic elements except As in Asan were higher than those in Seoul, suggesting that yellow dust in spring could affect $PM_{2.5}$ concentrations in Asan rather than Seoul. The correlation coefficients of Pb and Zn were 0.343 for Asan and 0.813 for Seoul during non-yellow dust condition, suggesting that Pb and Zn were influenced with the same sources. The correlation coefficients between Si and Fe in the fine particulate mode were 0.999 (Asan) and 0.998 (Seoul) during yellow dust condition. It was suggested that these two elements were impacted by soil-related transport from China during the yellow dust storm condition.

Assessments of Dissolved Rare Earth Elements and Anthropogenic Gadolinium Concentrations in Different Processes of Wastewater Treatment Plant in Busan, Korea (부산 하수처리장에서 공정별 용존 희토류 원소의 농도 및 인위적 기원 가돌리늄의 배출량 평가)

  • Lim, Ijin;Ryu, Jong-Sik;Lee, Joonyeob;Lee, Jun-Ho;Cho, Hyung-Mi;Kim, Taejin
    • Journal of the Korean earth science society
    • /
    • v.43 no.2
    • /
    • pp.303-311
    • /
    • 2022
  • Gadolinium, commonly used as a contrast agent for magnetic resonance imaging (MRI), is discharged into aquatic environments without removal after treatment in wastewater treatment plants (WWTPs) because of its high stability. In this study, we collected water samples from Suyeong WWTP, Busan, to investigate the dissolved rare earth element (REE) removal capacity of each wastewater treatment process and to evaluate the discharge of anthropogenic Gd (Gdanth) from effluents. As wastewater passed through each stage of treatment, the concentrations of light REEs (La-Eu) decreased, whereas those of heavy REEs (Tb-Lu) were relatively consistent. Negative Sm anomalies (<1) were observed in several samples, indicating that Sm can be removed by adsorption onto particles or phosphate during the biological removal process. Positive Gd anomalies (149±50, n=9) were observed in all samples. The ratios of Gdanth concentrations to measured Gd concentrations in all wastewater treatment processes were higher than 97%. This indicates that Gdanth was discharged to the Suyeong River without removal during the wastewater treatment process. Considering the daily treatment capacity in each process, the total flux of Gdanth was estimated to be 259 mmol/day. Our results suggest that mid- and/or long-term monitoring of Gd is needed because Gdanth is continuously discharged into Suyeong Bay through WWTPs.

Synthesis and Characterization of the Ag-doped TiO2

  • Lee, Eun Kyoung;Han, Sun Young
    • Elastomers and Composites
    • /
    • v.57 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • In this study, the photo-deposition method was used to introduce Ag onto the surface of TiO2 to synthesize an Ag-TiO2 composite. The effects of the varying amounts of AgNO3 precursor and annealing time periods on the Ag content in the composites, as well as their antibacterial characteristics under visible light conditions were studied. SEM analysis revealed the spherical morphology of the Ag-TiO2 composite. Compared with TiO2, the Ag particles were too small to be observed. An XPS analysis of the Ag-TiO2 surface confirmed the Ag content and showed the peak intensities for elements such as Ag, Ti, O, C, and Si. The highest Ag content was observed when 33.3 wt.% of AgNO3 and an annealing time of 6 h were employed; this was the optimum annealing time for Ti-Ag-O bonding, in that the lowest number of O bonds and the highest number of Ag bonds were confirmed by XPS analysis. Superior antibacterial properties against Bacillus and Escherichia coli, in addition to the widest inhibition zones were exhibited by the Ag-TiO2 composite with an increased Ag content in a disk diffusion test, the bacterial reduction rate against Staphylococcus aureus and Escherichia coli being 99.9%.

COMPUTATION OF TOTAL CHROMATIC NUMBER FOR CERTAIN CONVEX POLYTOPE GRAPHS

  • A. PUNITHA;G. JAYARAMAN
    • Journal of applied mathematics & informatics
    • /
    • v.42 no.3
    • /
    • pp.567-582
    • /
    • 2024
  • A total coloring of a graph G is an assignment of colors to the elements of a graphs G such that no adjacent vertices and edges receive the same color. The total chromatic number of a graph G , denoted by χ''(G), is the minimum number of colors that suffice in a total coloring. In this paper, we proved the Behzad and Vizing conjecture for certain convex polytope graphs Dpn, Qpn, Rpn, En, Sn, Gn, Tn, Un, Cn,respectively. This significant result in a graph G contributes to the advancement of graph theory and combinatorics by further confirming the conjecture's applicability to specific classes of graphs. The presented proof of the Behzad and Vizing conjecture for certain convex polytope graphs not only provides theoretical insights into the structural properties of graphs but also has practical implications. Overall, this paper contributes to the advancement of graph theory and combinatorics by confirming the validity of the Behzad and Vizing conjecture in a graph G and establishing its relevance to applied problems in sciences and engineering.

Source Apportionment Study and Chemical Composition of PM10 and PM2.5 in the Industrial Complex of Busan City, Korea (SEM-EDX 분석법에 의한 부산 S공업단지의 PM10과 PM2.5의 화학적 조성 및 발생원 추정)

  • Kim, Yong-Seog;Choi, Kum-Chan;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.26 no.11
    • /
    • pp.1297-1306
    • /
    • 2017
  • This study identified physical characteristics and aerosol particle sources of $PM_{10}$ and $PM_{2.5}$ in the industrial complex of Busan Metropolitan City, Korea. Samples of $PM_{10}$, $PM_{2.5}$ and also soil, were collected in several areas during the year of 2012 to investigate elemental composition. A URG cyclone sampler was used for collection. The samples were collected according to each experimental condition, and the analysis method of SEM-EDX was used to determine the concentration of each metallic element. The comparative analysis indicated that their mass concentration ranged from 1% to 3%. The elements in the industrial region that were above 10% were Si, Al, Fe, and Ca. Those below 5% were Na, Mg, and S. The remaining elements (1% of total mass) consisted of elements such as Ni, Co, Br and Pb. Finally, a statistical tool was applied to the elemental results to identify each source for the industrial region. From a principal components analysis (SPSS, Ver 20.0) performed to analyze the possible sources of $PM_{10}$ in the industrial region, five main factors were determined. Factor 1 (Si, Al), which accounted for 15.8% of the total variance, was mostly affected by soil and dust from manufacturing facilities nearby, Factors 2 (Cu, Ni), 3 (Zn, Pb), and 4 (Mn, Fe), which also accounted for some of variance, were mainly related to iron, non-ferrous metals, and other industrial manufacturing sources. Also, five factors determined to access possible sources of $PM_{2.5}$, Factor 1 (Na, S), accounted for 13.5% of the total variance and was affected by sea-salt particles and fuel incineration sources, and Factors 2 (Ti, Mn), 3 (Pb, Cl), 4 (K, Al) also explained significant proportions of the variance. Theses factors mean that the $PM_{2.5}$ emission sources may be considered as sources of incineration, and metals, and non-ferrous manufacturing industries.

Chemical Properties of the Metallic Elements and the Mass Concentration of PM10 and PM2.5 Observed in Busan, Korea in Springtime of 2006-2008 (2006-2008년 봄철 부산 지역 PM10과 PM2.5의 질량농도 및 금속성분의 화학적 특성)

  • Jeon, Byung-Il;Hwang, Yong-Sik
    • Journal of the Korean earth science society
    • /
    • v.31 no.3
    • /
    • pp.234-245
    • /
    • 2010
  • Twenty-four hour integrated $PM_{10}$ and $PM_{2.5}$ samples were measured during springtime (March, April, and May) in Busan for three years from 2006 to 2008, and mass concentrations and metallic elements of measurement were analyzed to investigate temporal, spatial, chemical characteristics of the mass concentration and metallic elements in association with meteorological conditions including Asian Dust (AD) vs. non Asian Dust (NAD) seasons, and other air mass transport patterns. The result showed that $PM_{10}$, $PM_{2.5}$ and $PM_{10-2.5}$ concentrations were on average of $126.2{\pm}89.8$, $85.5{\pm}41.6$, and $40.7{\pm}54.9{\mu}g/m^3$, respectively, and the $PM_{2.5}/PM_{10}$ and $PM_{10-2.5}/PM_{2.5}$ ratios were 0.70 and 0.48, respectively. The highest concentrations of PM were observed when air parcels were originated from both northwest sector covering Beijing and west sector including Shanghai areas.