• 제목/요약/키워드: Sub-Control unit

검색결과 185건 처리시간 0.03초

Genetic Characteristics and Immunogenicity of Pandemic H1N1 Influenza Virus Isolate from Pig in Korea

  • Hyoung Joon Moon;Jin Sik Oh;Woonsung Na;Minjoo Yeom;Sang Yoon Han;Sung Jae Kim;Bong Kyun Park;Dae Sub Song;Bo Kyu Kang
    • IMMUNE NETWORK
    • /
    • 제16권5호
    • /
    • pp.311-315
    • /
    • 2016
  • A pandemic influenza A (H1N1) virus strain was isolated from a pig farm in Korea in December 2009. The strain was propagated in and isolated from both the Madin-Darby canine kidney cell line and embryonated eggs. The partial and complete sequences of the strain were identical to those of A/California/04/2009, with >99% sequence similarity in the HA, NA, M, NS, NP, PA, PB1, and PB2 genes. The isolated strain was inactivated and used to prepare a swine influenza vaccine. This trial vaccine, containing the new isolate that has high sequence similarity with the pandemic influenza A (H1N1) virus, resulted in seroconversion in Guinea pigs and piglets. This strain could therefore be a potential vaccine candidate for swine influenza control in commercial farms.

매립가스의 에너지 회수 및 표면발산을 고려한 매립장 온실가스 배출 평가 (Assessment of Greenhouse Gas Emissions from Landfills Based on Energy Recovery and Surface Emissions of Landfill Gas)

  • 이용현;권용재;천승규
    • 신재생에너지
    • /
    • 제16권3호
    • /
    • pp.27-34
    • /
    • 2020
  • This study involved a total budget analysis on the greenhouse gas (GHGs) emissions of landfills, focusing on surface emissions and the effect on emissions reductions of generating landfill gas (LFG) electricity from March 7, 2007 to December 31, 2018. The GHGs reduction effect from the electricity generation using 536.6 × 103 tCO2 of CH4 was only 5.8% of the GHGs from surface emissions of 9,191 × 103 tCO2. In the total budget, the collection ratio should be over 95% if the reduction effect is greater than the surface emissions. The correlation coefficient for the relationship between the LFG collection ratio and GHGs reduction was -0.89. An additional effect of lowering CH4 content may occur if the surface emitting flux of LFG decreased with an increase in the collection ratio. The unit reduction effect of GHGs by suppressing surface emissions was 4174 tCO2/TJ. This was far greater than that of LFG power generated (54.3 tCO2/TJ), demonstrating that surface emission control is the most important measure by which to mitigate GHGs emission.

Effects of Fully Filling Deep Electron/Hole Traps in Optically Stimulated Luminescence Dosimeters in the Kilovoltage Energy Range

  • Chun, Minsoo;Jin, Hyeongmin;Lee, Sung Young;Kwon, Ohyun;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.134-142
    • /
    • 2022
  • Background: This study investigated the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps in the kV energy ranges. Materials and Methods: The experimental group consisted of InLight nanoDots, whose deep electron/hole traps were fully filled with 5 kGy pre-irradiation (OSLDexp), whereas the non-pre-irradiated OSLDs were arranged as a control group (OSLDcont). Absorbed doses for 75, 80, 85, 90, 95, 100, and 105 kVp with 200 mA and 40 ms were measured and defined as the unit doses for each energy value. A bleaching device equipped with a 520-nm long-pass filter was used, and the strong beam mode was used to read out signal counts. The characteristics were investigated in terms of fading, dose sensitivities according to the accumulated doses, and dose linearity. Results and Discussion: In OSLDexp, the average normalized counts (sensitivities) were 12.7%, 14.0%, 15.0%, 10.2%, 18.0%, 17.9%, and 17.3% higher compared with those in OSLDcont for 75, 80, 90, 95, 100, and 105 kVp, respectively. The dose accumulation and bleaching time did not significantly alter the sensitivity, regardless of the filling of deep traps for all radiation qualities. Both OSLDexp and OSLDcont exhibited good linearity, by showing coefficients determination (R2) > 0.99. The OSL sensitivities can be increased by filling of deep electron/hole traps in the energy ranges between 75 and 105 kVp, and they exhibited no significant variations according to the bleaching time.

A Study on the ECU and Control Algorithm of ABS for a Commercial Vehicle

  • Lee, Ki-Chang;Kim, Mun-Sub;Jeon, Jeong-Woo;Hwang, Don-Ha;Park, Doh-Young;Kim, Yong-Joo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.166.1-166
    • /
    • 2001
  • Anti-lock Braking System(ABS) is a device which prevents the wheels form locked up under emergency braking of a vehicle. So it helps the vehicle to maintain the steerability and shortens the braking distance by maintaining optimal frictional force during braking since the tire road slip is controlled in acceptable range. Recently, ABS is accepted as a standard equipment in vehicles, especially in commercial vehicles(bus and trucks). Commercial vehicles don´t use hydraulic lines but use pneumatic lines for braking system mostly. In this paper, ECU(Electronic Control Unit) for the anti-lock braking system of a commercial vehicle which is equipped with a full-air brake system and its control algorithms are presented. In this algorithm wheel speed acceleration flags and wheel slip flags are defined ...

  • PDF

최대전력 분석시뮬레이터 개발 및 조명설비 제어 시뮬레이션 (Maximum Power Analysis Simulator Development & Lighting Installation Control Simulation)

  • 장홍순;한영섭;서상현
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.95-99
    • /
    • 2013
  • The maximum power analysis simulator took advantage of the facilities and power consumption reduction simulator test scenario development and testing of improvement in the scenario. As a maximum demand power controller, Maximum power analysis simulator performs control and disperasion of maximum demand power by calculating base power, load forecast, and present power which are based on signal of watt-hour meter to keep the electricity under the target. In addition, various algorithms to select appropriate control methode on each of the light installations through the peak demand power is configured to management. The simulation shows the success of control power for the specified target controlled by five sequential lighting installations.

Distribution of the Population at Risk of Cholangiocarcinoma in Bua Yai District, Nakhon Ratchasima of Thailand Using Google Map

  • Kaewpitoon, Soraya J;Rujirakul, Ratana;Sangkudloa, Amnat;Kaewthani, Sarochinee;Khemplila, Kritsakorn;Cherdjirapong, Karuna;Kujapun, Jirawoot;Norkaew, Jun;Chavengkun, Wasugree;Ponphimai, Sukanya;Polsripradist, Poowadol;Padchasuwan, Natnapa;Joosiri, Apinya;Wakkhuwattapong, Parichart;Loyd, Ryan A;Matrakool, Likit;Tongtawee, Taweesak;Panpimanmas, Sukij;Kaewpitoon, Natthawut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권3호
    • /
    • pp.1433-1436
    • /
    • 2016
  • Background: Cholangiocarcinoma (CCA), a major problem of health in Thailand, particularly in Northeastern and Northern regions, is generally incurable and rapidly lethal because of presentation in stage 3 or 4. Early diagnosis of stage 1 and 2 could allow better survival. Therefore, this study aimed to provide a distribution map of populations at risk for CCA in BuaYai district of Nakhon Ratchasima province, Northeast Thailand. Materials and Methods: A cross-sectional survey was carried out in 10 sub-districts and 122 villages, during June and November 2015. The populations at risk for CCA were screened using the Korat CCA verbal screening test (KCVST) and then risk areas were displayed by using Google map (GM). Results: A total of 11,435 individuals from a 26,198 population completed the KCVST. The majority had a low score of risk for CCA (1-4 points; 93.3%). High scores with 6, 7 and 8 points accounted for 1.20%, 0.13% and 0.02%. The population at risk was found frequently in sub-district municipalities, followed by sub-district administrative organization and town municipalities, (F=396.220, P-value=0.000). Distribution mapping comprised 11 layers: 1, district; 2, local administrative organization; 3, hospital; 4, KCVST opisthorchiasis; 5, KCVST praziquantel used; 6, KCVST cholelithiasis; 7, KCVST raw fish consumption; 8, KCVST alcohol consumption; 9, KCVST pesticide used; 10, KCVST relative family with CCA; and 11, KCVST naive northeastern people. Geovisual display is now available online. Conclusions: This study indicated that the population at high risk of CCA in Bua Yai district is low, therefore setting a zero model project is possible. Key success factors for disease prevention and control need further study. GM production is suitable for further CCA surveillance and monitoring of the population with a high risk score in this area.

외상에 의한 마비성 토안(兎眼)의 외과적 치험례 (A CASE REPORT OF SURGICAL CORRECTION OF POSTTRAUMATIC LAGOPHTHALMOS)

  • 이태영;정봉준;김명섭
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권2호
    • /
    • pp.55-61
    • /
    • 1990
  • Patients with facial paralysis, in whom nerve damage is irreparable or in whom the innervation of the paralyzed musculature cannot be restored by nerve suture, grafting, or cross-face nerve transplantation, should be offered some form of reconstructive static and dynamic aid. Temporalis muscle-fascia unit used as a circumorbital sling and motor unit is a dynamic controlled reconstructive procedure, but it has several disadvantages such as wide surgical exposure, bulky-looking at lateral canthal area, insufficient voluntary control. This is a case report of facial palsy of posttraumatic lagophthalmos of 41-year-old male, which was corrected by temporalis muscle-tendon transfer with plantaris tendon transplantation.

  • PDF

소형 평면공구를 이용한 형상수정 폴리싱에 관한 연구 (A Study on Corrective Polishing Using a Small Flat Type Polisher)

  • 김의중;신근하
    • 한국정밀공학회지
    • /
    • 제19권1호
    • /
    • pp.99-106
    • /
    • 2002
  • For the development of a ultra-precision CNC polishing system including on-machine measurement system, we study a corrective polishing algorithm. We calculated unit removal profiles for various flat type polishing tools and polishing tool positions. Using these results we simulate the corrective polishing process based on dwell time control. We calculate dwell time distributions and residual error of the polishing simulation method and the FFT calculation method. We test corrective polishing algorithm with an optical glass. The target removal shape is a sine wave that has amplitude 0.3 micro meters. We find this polishing process has a machining resolution of nanometer order and is effective for sub-micrometer order machining. This result will be used for the software development of the CNC polishing system.

Clinical assessment of the efficacy of supraglottic airway devices compared with endotracheal tubes in cats during volume-controlled ventilation

  • Niyatiwatchanchai, Nutawan;Thengchaisri, Naris
    • Journal of Veterinary Science
    • /
    • 제21권2호
    • /
    • pp.27.1-27.10
    • /
    • 2020
  • The efficacies of a supraglottic airway device (SGAD) and an endotracheal tube (ETT) in cats under general anesthesia with volume-controlled ventilation (VCV) were compared. Thirty healthy cats were randomly allocated for airway control using either an SGAD or an ETT. Five tidal volumes (6, 8, 10, 12, and 14 mL/kg) were randomly tested, and respiratory rates were adjusted to achieve a minute ventilation of 100 mL/kg/min. The dose of propofol necessary to insert the SGAD or ETT, the static respiratory pressure, leakage during VCV, and end tidal CO2 (ETCO2) were recorded. Dosages of propofol and static respiratory measurements for the SGAD and ETT groups were compared using a t-test. The distribution of leakages and hypercapnia (ETCO2 > 45 mmHg) were compared using Fisher's exact test. A significance level of p < 0.05 was established. No significant difference in dose of propofol was observed between the SGAD and ETT groups (7.1 ± 1.0, 7.3 ± 1.7 mg/kg; p = 0.55). Static resistance pressure of the SGAD (22.0 ± 8.1 cmH2O/L/sec) was significantly lower than that of the ETT (36.6 ± 12.9 cmH2O/L/sec; p < 0.01). Of the 75 trials, leakage was more frequent when using an SGAD (8 events) than when using an ETT (1 event; p = 0.03). Hypercapnia occurred more frequently with SGAD (18 events) than with ETT (3 events; p < 0.01). Although intubation with an ETT is the gold standard in small animal anesthesia, the use of an SGAD can reduce airway resistance and the work of breathing. Nonetheless, SGAD had more dead space and the tidal volume for VCV needs adjustment.

지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구 (A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer)

  • 권영철;박진철
    • KIEAE Journal
    • /
    • 제8권4호
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.