• Title/Summary/Keyword: Sub System

Search Result 8,079, Processing Time 0.037 seconds

The Study of PM10, PM2.5 Mass Extinction Efficiency Characteristics Using LIDAR Data (라이다 데이터를 이용한 PM10, PM2.5 질량소산효율 특성 연구)

  • Kim, TaeGyeong;Joo, Sohee;Kim, Gahyeong;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_2
    • /
    • pp.1793-1801
    • /
    • 2021
  • From 2015 to June 2020, the backscattering coefficients of 532 and 1064 nm measured using LIDAR and the depolarization ratio at 532 nm were used to separate the backscattering coefficient at 532 nm as three types as PM10, PM2.5-10, PM2.5 according to particle size. The mass extinction efficiency (MEE) of three types was calculated using the mass concentration measured on the ground. The overall mean values of the calculated MEE were 5.1 ± 2.5, 1.7 ± 3.7, and 9.3 ± 6.3 m2/g in PM10, PM2.5-10, and PM2.5, respectively. When the mass concentration of PM10 and PM2.5 was low, higher than average MEE was calculated, and it was confirmed that the MEE decreased as the mass concentration increased. When the MEE was calculated for each type according to the mixing degree of Asian dust, PM2.5-10 was twice at pollution aerosol as high as 2.1 ± 2.8 m2/g, compare to pollution-dominated mixture, dust-dominated mixture, and pure dust of 1.1 ± 1.8, 1.4 ± 3.3, 1.1 ± 1.5 m2/g, respectively. However, PM2.5 MEE showed similar values irrespective of type: 9.4 ± 6.5, 9.0 ± 5.8, 10.3 ± 7.5, and 9.1 ± 9.0 m2/g. The MEE of PM10 was 5.6 ± 2.9, 4.4 ± 2.0, 3.6 ± 2.9, and 2.8 ± 2.4 m2/g in pollution aerosol (PA), pollution-dominated mixture (PDM), dust-dominated mixture (DDM), and pure dust (PD), respectively, and increased as the dust ratio value decreased. Even if the same type according to the same mass concentration or Asian dust mixture was shown, as the PM2.5/PM10 ratio decreased, the MEE of PM2.5-10 decreased and the MEE of PM2.5 showed a tendency to increase.

Design and Its Applications of a Hypercube Grid Quorum for Distributed Pub/Sub Architectures in IoTs (사물인터넷에서 분산 발행/구독 구조를 위한 하이퍼큐브 격자 쿼럼의 설계 및 응용)

  • Bae, Ihnhan
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1075-1084
    • /
    • 2022
  • Internet of Things(IoT) has become a key available technology for efficiently implementing device to device(D2D) services in various domains such as smart home, healthcare, smart city, agriculture, energy, logistics, and transportation. A lightweight publish/subscribe(Pub/Sub) messaging protocol not only establishes data dissemination pattern but also supports connectivity between IoT devices and their applications. Also, a Pub/Sub broker is deployed to facilitate data exchange among IoT devices. A scalable edge-based publish/subscribe (Pub/Sub) broker overlay networks support latency-sensitive IoT applications. In this paper, we design a hypercube grid quorum(HGQ) for distributed Pub/Sub systems based IoT applications. In designing HGQ, the network of hypercube structures suitable for the publish/subscribe model is built in the edge layer, and the proposed HGQ is designed by embedding a mesh overlay network in the hypercube. As their applications, we propose an HGQ-based mechansim for dissemination of the data of sensors or the message/event of IoT devices in IoT environments. The performance of HGQ is evaluated by analytical models. As the results, the latency and load balancing of applications based on the distributed Pub/Sub system using HGQ are improved.

Heat transfer analysis in sub-channels of rod bundle geometry with supercritical water

  • Shitsi, Edward;Debrah, Seth Kofi;Chabi, Silas;Arthur, Emmanuel Maurice;Baidoo, Isaac Kwasi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.842-848
    • /
    • 2022
  • Parametric studies of heat transfer and fluid flow are very important research of interest because the design and operation of fluid flow and heat transfer systems are guided by these parametric studies. The safety of the system operation and system optimization can be determined by decreasing or increasing particular fluid flow and heat transfer parameter while keeping other parameters constant. The parameters that can be varied in order to determine safe and optimized system include system pressure, mass flow rate, heat flux and coolant inlet temperature among other parameters. The fluid flow and heat transfer systems can also be enhanced by the presence of or without the presence of particular effects including gravity effect among others. The advanced Generation IV reactors to be deployed for large electricity production, have proven to be more thermally efficient (approximately 45% thermal efficiency) than the current light water reactors with a thermal efficiency of approximately 33 ℃. SCWR is one of the Generation IV reactors intended for electricity generation. High Performance Light Water Reactor (HPLWR) is a SCWR type which is under consideration in this study. One-eighth of a proposed fuel assembly design for HPLWR consisting of 7 fuel/rod bundles with 9 coolant sub-channels was the geometry considered in this study to examine the effects of system pressure and mass flow rate on wall and fluid temperatures. Gravity effect on wall and fluid temperatures were also examined on this one-eighth fuel assembly geometry. Computational Fluid Dynamics (CFD) code, STAR-CCM+, was used to obtain the results of the numerical simulations. Based on the parametric analysis carried out, sub-channel 4 performed better in terms of heat transfer because temperatures predicted in sub-channel 9 (corner subchannel) were higher than the ones obtained in sub-channel 4 (central sub-channel). The influence of system mass flow rate, pressure and gravity seem similar in both sub-channels 4 and 9 with temperature distributions higher in sub-channel 9 than in sub-channel 4. In most of the cases considered, temperature distributions (for both fluid and wall) obtained at 25 MPa are higher than those obtained at 23 MPa, temperature distributions obtained at 601.2 kg/h are higher than those obtained at 561.2 kg/h, and temperature distributions obtained without gravity effect are higher than those obtained with gravity effect. The results show that effects of system pressure, mass flowrate and gravity on fluid flow and heat transfer are significant and therefore parametric studies need to be performed to determine safe and optimum operating conditions of fluid flow and heat transfer systems.

Characterization of NOx Reduction on Filter Bag Support System at Low Temperature using Powder Type MnOx and V2O2/TiO2 Catalysts (분말형 MnOx와 V2O2/TiO2 촉매를 이용한 저온영역의 백필터 공정에서 질소산화물 제거 특성)

  • Kim, Byung-Hwan;Kim, Jeong-Heon;Kang, Pil-Sun;Yoo, Seung-Kwan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • In this study, the selective catalytic reduction of $NO_x$ with ammonia was carried out in a filter bag support reactor. The experiments were performed by powder type $MnO_x$ and $V_2O_5$/$TiO_2$ catalyst at low temperature between 130 and $250^{\circ}C$. Also, the effect of $SO_2$ and $H_2O$ on the NO conversion was investigated under our test conditions. The powder type catalysts were analyzed by X-ray photoelectron spectrum (XPS), X-ray diffraction(XRD), scanning electron microscopy (SEM) and thermal gravimetric analysis (TGA). It was observed that NO removal efficiency of the powder type $V_2O_5$/$TiO_2$ catalyst was 85% at low temperature($200^{\circ}C$) under presence of oxygen and that of $MnO_x$ was 50% at the same condition. The powder type $V_2O_5$/$TiO_2$ catalyst, in conclusion, was found to be available for SCR reaction in a filter bag support system.

A Fundamental Study of Structure-Property Relationships in $Eu^{3+}$ Luminescence ($Eu^{3+}$ 이온의 발광성에 대한 구조와 성질의 기본적인 연구)

  • Chang, Ki-Seog
    • Korean Journal of Crystallography
    • /
    • v.13 no.1
    • /
    • pp.25-30
    • /
    • 2002
  • The M/sub 1-x/Na/sub 2x/Al₂(BO₃)₂O (M = Ca and Sr) solid solution systems have been shown interstitial solid solutions and continuous substitutional solid solutions. The symmetry around the Eu site of yEu/sup 3+/ : M/sub 1-x/Na/sub 2x/Al/sub 2-y/Mg/sub /(BO₃)₂O (M = Ca and Sr) changes the intensities and the chromaticities of transitions. The Eu/sup 3+/ion can be very bright and efficient and have the desired emission wave-length depending on the site symmetry of the Eu/sup 3+/ion site. As the amount of Na in the Eu/sup 3+/ion doped Ca/sub 1-x/Na/sub 2x/Al₂(BO₃)₂O system increases, the Eu site symmetry is going to be a noncentrosymmetric site. With increasing x, the decreased intensity in the /sup 5/D/sub 0/→/sup 7/F₁(590 nm) transition relates to the low symmetry of the Eus/up 3+/-doped Ca/sub 1-x/Na/sub 2x/Al₂(BO₃)₂O system, because of the Ca-centered octahedron in the CaAl₂(BO₃)₂O compound. The SrAl₂(BO₃)₂O compound also provides an improved chromaticity due to the lower site symmetry of Eu/sup 3+/ion.

Preparation of Photocurable Slurry for DLP 3D Printing Process using Synthesized Yttrium Oxyfluoride Powder (합성 불산화 이트륨 분말을 이용한 DLP 3D 프린팅용 광경화성 슬러리 제조)

  • Kim, Eunsung;Han, Kyusung;Choi, Junghoon;Kim, Jinho;Kim, Ungsoo
    • Korean Journal of Materials Research
    • /
    • v.31 no.9
    • /
    • pp.532-538
    • /
    • 2021
  • In this study, a spray dryer is used to make granules of Y2O3 and YF3, and then Y5O4F7 is synthesized following heat treatment of them under Ar gas atmosphere at 600 ℃. Single and binary monomer mixtures are compared and analyzed to optimize photocurable monomer system for DLP 3D printing. The mixture of HEA and TMPTA at 8:2 ratio exhibits the highest photocuring properties and low viscosity with shear thinning behavior. The optimized photocurable monomer and synthesized Y5O4F7 are therefore mixed and applied to printing process at variable solid contents (60, 70, 80, & 85 wt.%) and light exposure times. Under optimal light exposure conditions (initial exposure time: 1.2 s, basic exposure time: 5 s), YOF composites at 60, 70 & 80 wt.% solid contents are successfully printed. As a result of measuring the size of the printed samples compared to the dimensions of the designed bar type specimen, the deviation is found to increase as the YOF solid content increases. This shows that it is necessary to maximize the photocuring activity of the monomer system and to optimize the exposure time when printing using a high-solids ceramic slurry.

Effect of Microstructure on Piezoelectric Properties and TCC Behavior in PZT-PZN Ceramics (PZT-PZN 세라믹의 미세구조가 압전 특성 및 TCC 거동에 미치는 영향)

  • Seo, Intae;Choi, Yongsu;Cho, Yuri;Kang, Hyung-Won;Kim, Kang San;Cheon, Chae Il;Han, Seung Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.445-451
    • /
    • 2022
  • Ultrasonic sensor is suitable as a next-generation autonomous driving assist device because its lower price compared to that of other sensors and its sensing stability in the external environment. Although Pb(Zr, Ti)O3 (PZT)-relaxor ferroelectric system has excellent piezoelectric properties, the change in capacitance is large in the daily operating temperature range due to the low phase transition temperature. Recently, many studies have been conducted to improve the temperature stability of ferroelectric ceramics by controlling the grain size and crystal structure, so it is necessary to study the effect of the grain size on the piezoelectric properties and the temperature stability of PZT-relaxor ferroelectric system. In this study, the piezoelectric properties, phase transition temperature, and temperature coefficient of capacitance (TCC) of 0.9 Pb(Zr1-xTix)O3-0.1 Pb(Zn1/3Nb2/3)O3 (PZTx-PZN) ceramics with various grain sizes were investigated. PZTx-PZN ceramics with larger grain size showed higher piezoelectric properties and temperature stability, and are expected to be suitable for ultrasonic devices in the future.

A comparative study to measure the sagittal condylar inclination using mechanical articulator, virtual articulator and jaw tracking device

  • Liya Ma;Fei Liu;Jiansong Mei;Jiarui Chao;Zhenyu Wang;Jiefei Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2023
  • PURPOSE. To compare the sagittal condylar inclination (SCI) in dentate individuals measured by the different methods with mechanical articulator (MA), virtual articulator (VA), and a jaw tracking device (JTD) system. MATERIALS AND METHODS. A total of 22 healthy dentate participants were enrolled in this study. For MA workflow, the SCI was obtained by a semi-adjustable articulator with protrusive interocclusal records. The SCI was also set on a VA by aligning intraoral scan (IOS) with cone beam computed tomography (CBCT) and facial scan (FS), respectively. These virtual workflows were conducted in a dental design software, namely VAIOS-CBCT and VAIOS-FS. Meanwhile, a JTD system was also utilized to perform the measurement. Intraclass correlation was used to assess the repeatability within workflows. The bilateral SCI values were compared by Wilcoxon matched-pairs signed rank test for each workflow, and Kruskal-Wallis test and post hoc p-value Bonferroni correction were used to compare the differences among four workflows. The agreement of VAIOS-CBCT, VAIOS-FS, and JTD compared with MA was evaluated by Bland-Altman analysis. RESULTS. Intraclass correlation of the SCI revealed a high degree of repeatability for each workflow. There were no significant differences between the left and right sides (P > .05), except for VAIOS-CBCT (P = .028). Significant differences were not found between MA and VAIOS-FS (P > .05). Bland-Altman plots indicated VAIOS-CBCT, VAIOS-FS, and JTD were considered to substitute MA with high 95% limits of agreement. CONCLUSION. The workflow of VAIOS-FS provided an alternative approach to measure the SCI compared with MA.

Experimental Study of Showcase Using Cold Storage System (축냉 시스템을 적용한 쇼케이스 운전에 대한 실험적 연구)

  • Lee, Eun-Ji;Lee, Dong-Won;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1111-1116
    • /
    • 2008
  • The purpose of this study is to maintain high efficiency and reasonable use of cold-heat storage systems operated the showcase. An experimental study is carried out to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that at the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling.

  • PDF

선형가속기를 이용한 뇌정위 방사선수술시 Isocentric sub system의 기하학적 오차

  • 이석춘;오종영;김남석
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.45-53
    • /
    • 1995
  • 목적 : 뇌정위 방사선수술은 AVM(ateriovenous malformation)이나 작은 크기의 종양에 1회에 고선량의 방사선을 조사하는 기술이다. 선형가속기를 이용한 방사선 수술을 하기 위하여 최근 본원에 설치한 Philips SL 75-5 선형가속기와 isocentric sub system(ISS)에 의한 뇌정위 방사선 수술에 있어서 표적의 위치선정과, gantry와 couch의 회전시 기하학적 오차가 중요시 되는데 isocentric sub system의 오차를 분석 하였다. 대상 및 방법 : 방사선원으로는 Philips SL 75-5 선형가속기의 5MV 광자선을 사용하였고, 원형의 작은 광자선속을 위하여 isocenter에서의 직경이 26mm인 secondary cone을 gimbal baaring에 삽입하여 사용하였다. 표적의 크기와 좌표를 정하기 위하여 CT나 angio localizer를 이용하고, 표적좌표 선정을 위하여 BRW phantom base와 target pointer를 이용하여 임의의 BRW-coordinator를 바꾸어 가면서 gantry angle와 ISS head 각도를 임의로 바꾸어 가면서 film에 방사선을 조사하였다. 흑화된 film을 view box 위에 놓고 광학판독기구로 film 가장자리의 오차를 scale 확대경으로 측정하여 오차를 분석하였다. 결과 : 표적좌표 선정의 정확도를 확인하기 위하여 임의의 표적좌표에 gantry의 10개각도 ISShead의 10개각도에서 각각 광자선을 조사시켜 film을 이용하여 오차를 측정한 결과 collimator cone의 직경이 26mm일때 전체 평균오차가 0.219+-0.03mm이었다. 결론 : Isocentric sub system은 gantry head와 ISS arm 사이에 gimbal bearing이 있어서 이 부위를 flexible하게 연결함으로 gantry의 회전에 무관하게 정확한 isocenter를 유지시켜 주고 ISS head는 couch와 독립되어 움직이므로 isocentric sub system isocenter의 오차를 최대한 줄일수 있음을 알았다.

  • PDF