• Title/Summary/Keyword: Stylus

Search Result 126, Processing Time 0.031 seconds

An Experimental Study on Selecting the Diameter of Probe Stylus of a Coordinate Measuring Machine in Measuring the Edge Profile of High Pressure Compressor (압축기 블레이드의 Edge 형상 측정시 3차원 측정기의 탐침 볼 직경 선정을 위한 실험적 연구)

  • Joung, Soo-Ho;Byun, Jai-Hyun
    • IE interfaces
    • /
    • v.15 no.4
    • /
    • pp.432-438
    • /
    • 2002
  • When the trailing edge and leading edge of an airfoil contour of high pressure compressor blades are measured, there exists a measurement error due to the size of the probe stylus ball diameter. In the paper an experimental study is provided to determine the optimum diameter of the probe stylus in inspecting the airfoil of the high pressure compressor blade. The measurement and analysis procedure suggested in this paper will be helpful to those who are involved in measuring and inspecting various types of blades.

An Error Compensation in Rough Surface Measurement by Contact Stylus Profilometer (표면미세형상측정을 위한 접촉식 형상측정기의 오차 보정)

  • 조남규
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.1
    • /
    • pp.126-134
    • /
    • 1999
  • In this paper, a new error compensating technique for form-error compensation of rough-surface profile obtained by contact stylus profilometer is proposed. By the method, the real contact points of rough-surface and diamond stylus can be estimated and the measured profile data corrected. To verify the compensation effect, the properties(Ra, RMS, Kurtosis, Skewness) of measured profile data and compensated data were compared. And, the cumulative RMS slope was proposed to assess the compensated effect of upper area of profile. The results show that the measuring error could be compensated very well in amplitude parameters and in proposed cumulative RMS slope by the developed form-error compensating technique.

  • PDF

Development of Straightness Measurement System thor Flat Workpieces (평면 공작물 진직도 측정 시스템 개발에 관한 연구)

  • Kim, Hyeon-Su;Jang, Mun-Ju;Hong, Seong-Uk;Park, Cheon-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.3
    • /
    • pp.107-113
    • /
    • 2002
  • This paper presents a straightness measurement system for flat and long workpieces. The measurement system consists of a laser, a CCD camera and processing system, a carrier system with a stylus, and some optical units. The carrier system accompanies the stylus, which displaces and retroreflector along the surface profile. The optical unit is used to optically amplify displacement of the stylus unit. The developed system is applied to a ground surface and a LM guide unit. The experimental results show that the developed system can measure the straightness of flat surface and moving systems.

A Study of Development for Contact CMM Probe using Three-Component Force Sensor (3 분력 힘 센서를 이용한 CMM 용 접촉식 프로브의 개발에 관한 연구)

  • 송광석;권기환;박재준;조남규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.101-107
    • /
    • 2003
  • A new mechanical probe for 3-D feature measurement on coordinate measuring machines (CMMs) is presented. The probe is composed of the contact stylus and the three-component force sensor. With the stylus mounted on the force sensor, the probe can not only measure 3-D features, but also detect contact force acting on the stylus tip. Furthermore, the probing direction and the actual contact position can be determined by the relationship among three components of contact force to be detected. In this paper, transformation matrix representing the relationship between the external force acting on the stylus tip and the output voltages of measurement gauges is derived and calibrated. The prototype of probe is developed and its availability is investigated through the experimental setup for calibration test of the probe. A series of experimental results show that the proposed probe can be an effective means of improving the accuracy of touch probing on CMM.

Measurement of Saw-Teeth Wear by TALYSURF (TALYSURF에 의한 톱니의 마모량측정)

  • Hyun, Jung-Ihn;Klamecki, Barney E.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.22-27
    • /
    • 1980
  • Quantitative assessment of edge blunting of saw-teeth was carried out by TALYSURF. 1. Using the following equation, the real shape of a saw-tooth can be traced on the graph of TALYSURF. ${\frac{{\Delta}h}{h}}={\frac{V{\Delta}_x}{V_x}}$ {${\Delta}h$: vertical distance of stylus h: vertical distance in chart $V{\Delta}_x$: Velocity of stylus $V_x$: velocity of chart} 2. As shown on Fig 2, the error from stylus itself can be calculated by following equation. i) 13.8${\mu}{\leqq}$x<20.4${\mu}$ y=-0.2246x+4.59${\mu}$ ii) 0${\leqq}$x<13.8${\mu}$ y=${\sqrt{(-18{\mu})^2-x^2}}-1.42x+32.7{\mu}}$ 3. The relationship between profile of saw-tooth and error from stylus itself can be calculated by following equation. $E(%)=\frac{f(r){\times}{\frac{4}{18{\mu}}}}{f(R){\times}{\frac{R}{18.5{\mu}}}-f(r){\times}{\frac{r}{18{\mu}}}}{\times}100$ {E(%)${\frac{error\;of\;stylus}{dullness\;of\;saw\;tooth}}{\times}100$ r: radius of stylus tip R: radius of tip which is drawn in graph of talysurf f(r) : error of stylus f(R) : dullness of tip which is drawn in graph of talysurf} 4. The graph of maximum error and profile of saw-tooth was parabola.

  • PDF

Development of Diaphragm-type Stylus Probe for Ultra-precision On-machine Measurement Application (초정밀 기상측정용 다이아프램 타입 접촉식 프로브의 개발)

  • Lee, Jung-Hoon;Lee, Chan-Hee;Choi, Joon-Myeong;Kim, Ho-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.845-852
    • /
    • 2012
  • The diaphragm-type stylus probe was developed for ultra-precision on-machine measurement (OMM) application. This probe is equipped with two diaphragms which are parallel and one capacitive sensor is used for detecting the vertical motion of end tip in the stylus when it is contacted to the optical freeform surface. For better performance of proposed probes, several design parameters such as axial stiffness and the lateral deformations were investigated with finite element analysis techniques. To verify the feasibility, the profiles of the master sphere ball were measured on the ultra-precision milling machine. The measurement results show that the proposed probe can calculate the radius of the circle within the accuracy of 0.1 ${\mu}m$ for the ultraprecision optical surface.

Dependence of electron and photon emission during abrasion by surface condition of magnesium oxide crystal

  • Hwang, Do-Jin;Kim, Jong-Min;Park, Eun-Hee;Kim, Myoung-Won
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • We measured the simultaneous, time-resolved spectra of photon emission, electron emission, and frictional force during the abrasion single crystal MgO with a diamond stylus in vacuum. phE and EE signal can be detected with millisecond resolution during the wear of a single crystal MgO substrate with a diamond stylus. The emissions and wear behavior are strong function of surface condition, load and stylus velocity. Measurement on annealed vs as-received material show that the luminescence is primarily due to deformation, and the electron emission is primarily due to fracture. These emissions provide insight into the processes responsible for catastrophic failure of ceramics in wear applications.

  • PDF

Development of a Compact Tactile Display Module and Its Application to a Haptic Stylus (소형 질감제시 모듈 개발 및 펜형 촉감 인터페이스)

  • Kyung, Ki-Uk;Park, Jun-Seok
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.25-31
    • /
    • 2007
  • 본 논문에서는 질감제시장치와 진동모터를 내장한 펜형 햅틱(haptic) 인터페이스에 대해서 기술한다. 본 연구의 목적은 다양한 장치에 적용할 수 있는 소형 질감제시 모듈을 제안하고, 개발된 모듈을 펜과 같은 모양의 인터페이스에 내장하여 그 성능을 검증하는데 있다. 본 연구의 수행을 위해 핀배열을 내장하고 있으며, 저전력, 저소음으로 동작하며, 수직방향으로 1mm이상의 변위를 일으키는 소형 질감제시 모듈을 개발하였다. 그리고 개발된 모듈은 PDA나 Tablet PC등에서 흔히 사용되는 스타일러스(Stylus)와 같은 펜모양의 인터페이스에 내장되었다. 펜형 인터페이스의 헤드부분에는 팬케익 모터를 내장하여 사용자에게 진동 촉감을 제공할 수 있도록 하였다. 개발된 펜형 인터페이스의 성능을 검증하기 위하여Mobile Tablet PC상에서 내장된 질감제시 모듈이 점자정보를 촉감으로 전달할 수 있는지에 관한 실험을 수행하였으며, 모든 실험은 그래픽 사용자 인터페이스(GUI)상에서 이루어졌다. 또한 모든 버튼 조작시 '클릭'하는 느낌을 재현하였다. 실험은 동시에 다양한 자극의 주파수와 시간의 변화 조건에서 시행되어 의도하는 촉감을 가장 잘 전달하는 자극방법에 관한 연구를 동시에 수행하였다. 또한 개발된 펜형 인터페이스를 이용하여 이미지와 함께 데이터 베이스화 되어있는 질감을 재현할 수 있는 방법에 관한 기초 연구를 수행하였다.

  • PDF

Coordinate Measurement in Wired Tablet Using a Electromagnetic Induction System (전자기유도기술을 이용한 유선 태블릿 좌표 측정)

  • Hong, Dong-Goo;Ryu, Young-Kee
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1099-1100
    • /
    • 2008
  • In this paper, we would like to introduce a simple and low cost wired pointing device by using a electromagnetic induction. A number of patents of Wacom describe electronic drawing devices or styluses. The movement of the stylus over a tablet is traced electronically and used applied to a resonant circuit in the stylus. Electromagnetic radiation emitted by the resonant circuit is detected by a sensing mechanism and location processing is used to locate the stylus. In this research, difference coil principle is used to detect the emitted radiation of the resonant circuit in the pen. This detection device shows good performance to detect the location of the pen on the tablet.

  • PDF

Development of straightness measurement system for flat workpiece (평면 공작물의 진직도 측정 시스템 개발)

  • 김현수;조명동;장문주;홍성욱;박천홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.203-206
    • /
    • 2001
  • This paper presents a straightness measurement system for flat and long workpieces. The measurement system consists of a laser optical unit, a CCD camera and processing system, and a carrier system with a stylus. The carrier system accompanies the stylus, which displaces a retroreflector along the surface profile. The optical unit is used to optically amplify the displacement of retroreflector. The CCD camera and processing system finally identifies the vertical displacement of the stylus unit. The developed system is applied to two surfaces: ground surface and LM guide surface. The experimental results show that the developed system can measure the straightness of flat surfaces within sub-micron error.

  • PDF