• Title/Summary/Keyword: Studs

Search Result 230, Processing Time 0.029 seconds

Evaluation of the Joint Design in Composite Truss Bridges (복부 트러스 복합교량 접합구조의 실험적 연구)

  • Shim, Chang-Su;Park, Jae-Sik;Kim, Kwang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.325-328
    • /
    • 2006
  • Joint structures of composite truss bridges can have the same details for the connection between diagonal members and upper concrete slab as the connection between diagonal members and lower concrete slab. Adequate connection details should be decided according to design codes, constructibility, and economical evaluation. It is necessary to clarify the design check items and load transferring mechanism because combined external loads on composite truss bridges are concentrated at the joints. Joints with gusset plates and stud connectors are applied and complicated joint details may arise some problems in construction. This paper deals with experimental evaluation of the joints in composite truss bridges and proper design provisions were investigated to enhance the details. Push-out test specimens with group studs were fabricated and the effects of grouping and bent studs were studied.

  • PDF

Reliability Evaluations for Shear Strength of Resistance Welded Ball Stud according to Different Cooling Methods

  • Park, In-Duck;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.22 no.6
    • /
    • pp.44-50
    • /
    • 2018
  • As a type of bolt with a spherical head, the ball stud is widely used as a part of a ball joint in steering or suspension systems in automobiles. Balls and studs are subjected to heat treatment suitable for each material; in particular, the shear strength of the ball stud must meet the specifications of the production company. This study evaluated the shear strength of joints according to the cooling method of ball studs subject to resistance welding. The shear stress of water cooling was higher than that of air cooling (as-received material). Note, however, th at oil cooling showed lower stress than that of as-received. When judged by standard deviation, mean, and coefficient of variation according to the arithmetic statistics and shape parameter as well as scale parameter, oil cooling is suitable.

Experimental analysis on steel and lightweight concrete composite beams

  • Valente, Isabel B.;Cruz, Paulo J.S.
    • Steel and Composite Structures
    • /
    • v.10 no.2
    • /
    • pp.169-185
    • /
    • 2010
  • The present work describes the experimental tests on steel and lightweight concrete composite beams performed at University of Minho, Portugal. The study involves tests on simply supported composite beams of 4.5 m span, with the same geometrical disposition, supports and materials. The geometrical configuration for the cross section and supports is identical for every beam, varying the shear connectors' distribution and the loading conditions. Headed studs are used to provide the connection between the steel profile and the concrete slab. The parameters in study are the stud disposition and the load distribution. The main objective is to describe the composite beams behaviour, focused on its connection, and to analyse the contribution of the different components to the beams load and deformation capacity. All the tests explored the beams maximum load and deformation capacity and different types of failure were observed.

Structural Load Bearing Capacity of Wall System Framed by Studs and Runners using Square Steel Tubes (각형강관을 이용한 스터드-런너 골조형 벽체시스템의 구조내력 성능평가)

  • Kim, Ho Soo;Hong, Seok Il;Lim, Young Do
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.253-262
    • /
    • 2005
  • Because the framed wall system using steel studs and runners with square steel tubes as structural elements is reinforced by the horizontal members called runners, it has more strength and load bearing capacity than the steel house wall system. Also, this system improves adiabatic and sound insulation performance by filling up the autoclaved lightweight concrete. We need to evaluate load bearing capacity according to the axial load and lateral load in case this system is applied in the housing system with 3~5 stories through variations in intervals for the runners under the placement effect of autoclaved lightweight concrete. Therefore, this study seeks to analyze axial and shear behavior of the framed wall system according to the placement effect of autoclaved lightweight concrete, and to secure safety for the vertical and lateral loads.

Analytical Study for Performance Improvement of Studs for Steel Plate Concrete(SC) Walls subjected to Combined Loads (조합하중을 받는 강판 콘크리트(SC) 벽체에서 스터드의 성능개선을 위한 해석적 연구)

  • Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.108-116
    • /
    • 2015
  • This study analytically reviewed the behavior of Steel Plate Concrete(SC) walls subjected to combined loads of axial force, flexural moment, and shear force to investigate the effects of shape and arrangement spacing of studs on the behavior of SC walls. To perform it, 9 cases of finite element analyses considering the different shape and spacing of studs in SC wall were carried out. The results showed that, for SC walls combined steel plate and concrete according to the Design Code, the compressive strength is higher than the tensile strength. Compared results from the finite element analyses of SC walls subjected to combined loads with Design Code showed that all cases were higher than the design strength. For KEPIC SNG, the moment and shear force were not influenced by the axial force of 0.1 to 0.2 times axial strength, however, from the analyses, it was found that the values were decreased as the axial force is increased.

Experimental and Analytical studies on Failure Behavior of Stud Shear Connectors in CFT Structures (CFT 구조에 적용된 스터드 전단연결재의 파괴 거동에 대한 실험 및 해석적 연구)

  • Lee, Sangyoon
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.400-412
    • /
    • 2013
  • For the composite behavior of steel tube and inner concrete, the shear connectors should be applied to the CFT structures. However, the present design codes don't provide the design criteria that can be applied on shear connectors in the CFT structures typically filled with plain concrete. This study has been carried out to propose design criteria (shear strength and resistance factor) for the stud shear connectors in CFT structures. Experimental tests using the push-out specimens with the plain concrete blocks and finite element analysis were conducted for the purpose of verifying the main failure mode to propose the shear strength of studs in CFT structures. From the results of this study, the main failure mode of studs in CFT structures is splitting crack of concrete and this failure mode reduces shear strength of studs in CFT structures relatively to those embedded in RC blocks.

Analytical Study for Design of Shape and Arrangement Spacing of Studs in Steel Plate Concrete(SC) Wall subjected to Shear and Axial Forces (전단력과 축하중을 받는 강판 콘크리트(SC) 벽체에서 스터드의 형상과 배치간격의 설계를 위한 해석적 연구)

  • Cho, Sung-Gook;Lim, Jin-Sun;Jeong, Young-Do;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.67-76
    • /
    • 2014
  • In this study, the behavior of Steel Plate Concrete (SC) walls subjected to shear and axial forces to investigate the effects of shape and arrangement spacing of studs on the design of SC walls was analytically reviewed. For this purpose, 9 cases of finite element analyses considering the different shape and spacing of studs in SC wall were performed. The results showed that the steel plate was yielded at the lower load than the second yielding shear force of the design skeleton curve when the spacing of stud is excessively far from each other. It is also found that the shape of the stud did not affect the shear behavior of SC wall but, the spacing influenced to its composite action. In this study, it was also proven that the inclined shaped stud resists more effectively to the bucking load than the general shaped stud in SC wall.

A Design of the Cat's Eye System with Low Power Consumption Using Solar Energy (태양광을 이용한 저전력의 LED 표지병 설계)

  • Kim, Keun-Sik;Kim, Jong-Hoon
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.181-187
    • /
    • 2016
  • Typical Retro-reflectors installed on road have problems such as limiting a driver's visibility at night when it is foggy or rainy. On the other hand, LED illuminated studs, called cat's eye system, extends a driver's visibility under these conditions. In this paper, we present a design of the LED cat's eye system using solar energy that can sustain vehicles with about 30-ton weight and is compliant with the IP68 code for water proof as IEC standard 60529. In addition, we propose a scheme of designing a LED driving circuit consuming low power to take into accounts cold weather or rainy season with limited sunlight. This LED cat's eye studs is currently installed and used on expressway and bike route nationally as well as overseas.

Analysis of the Load Carrying Behavior of Shear Connection at the Interface of Encased Composite Beams (매입형 합성보의 전단합성거동에 대한 비교분석)

  • Shin, Hyun Seop;Heo, Byung Wook;Bae, Kyu Woong;Kim, Keung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.67-79
    • /
    • 2008
  • In this study, a bending test with three encased composite beams were carried out and analyzed using FEM in order to find how chemical adhesion, interface interlock, friction and composite action by shear studs contribute to stiffness, strength and composite action in the interface of encased compo site beams. The test and results of the FEM analysis showed that the difference in the ultimate moment capacity of the composite beams with and without studs is under 10%. The reason is that the effect of chemical adhesion, interface interlock, and friction in the interface on the composite action is so high that the encased beams have a moment capacity above some defined magnitude. Also, the increment of moment capacity up to plastic moment is not large and the increase of linearly proportioned.