• Title/Summary/Keyword: Stud design

Search Result 165, Processing Time 0.023 seconds

Analysis of Impact load for the container loaded trailer (컨테이너가 상차될 때 트레일러가 받는 충격하중 해석)

  • 김재헌;홍도관;김중완;전언찬;안찬우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.277-281
    • /
    • 1997
  • Reliab~l~ty englneerlng IS regarded as the major and important roll for all Industry And advanced nianufactur~ng systems w~th h~gh speed and lntell~gent ha\\ulcorner been dcvelop~ng for betterment of lnachln~ng db~l~ty In th~study, Me have rystem~~ed c\, ~luat~on c r f relidb~litl for nldchlntry system We proposed the rel~ab~l~ty asvxmcnt and dci~yned and manufactured r~ildb~llty tcst-bed to eualuate rcl~dbil~ty In ddd~t~on we acquired relldb~l~ty data uslng test-bed sydem and mde database to handle relrab~l~t) data And also he not only use rel~ab~l~ty data by andlyzlng rel~ab~l~ty, but also apply design revlew method usmg analycing crltlcal unlt5 of machlnery system From th~s stud), he u ~ l l expect to gu~de md Increase the rel~ab~l~t) englneerlng in devclop~ng and procerslng phase of h~gh qualrty product

  • PDF

Partial-interaction fatigue assessment of stud shear connectors in composite bridge beams

  • Seracino, Rudolf;Oehlers, Deric J.;Yeo, Michael F.
    • Structural Engineering and Mechanics
    • /
    • v.13 no.4
    • /
    • pp.455-464
    • /
    • 2002
  • There is a growing demand to assess the remaining strength and endurance of existing composite steel and concrete bridge beams due to the aging infrastructure, increases in permissible vehicle weights and increases in their frequencies. As codes are generally dedicated to the design of new structures, new procedures are required to aid in the assessment of existing bridges to ensure that they are utilised to the full. In this paper, simple expressions are presented to perform partial-interaction analyses directly from full-interaction analyses, so that the beneficial effect of partial-interaction on the shear forces on the shear connectors can be utilised in assessment to extend the fatigue life of simply supported bridge beams and to determine the effect of remedial work if necessary. Use of the assessment technique is described by way of an illustrative example.

Composite Bonding Methods of Steel Pipe Piles into Pile Caps Using Steel Couplers (강재결합구를 이용한 강관말뚝 합성형 두부결합 방법)

  • 오성남;심창수;유재남;홍성영
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.323-330
    • /
    • 2001
  • The existing bonding methods of steel pipe piles into pile caps have many problems during construction or design. To overcome these, the composite bonding method of the bolting type and the welding type are proposed in this stud\ulcorner. The full scale test and the numerical analysis using finite element method were performed to verify the function of them. As results, the method of the filled with concrete in steel pipe piles head was good effective to increse strength. And the composite bonding methods are effective to protect the damage caused by earthquake than the bolted bonding method. Also, the composite bonding methods are cheaper than the existing bonding methods and a good construction as well.

  • PDF

Determining the effective width of composite beams with precast hollowcore slabs

  • El-Lobody, Ehab;Lam, Dennis
    • Structural Engineering and Mechanics
    • /
    • v.21 no.3
    • /
    • pp.295-313
    • /
    • 2005
  • This paper evaluates the effective width of composite steel beams with precast hollowcore slabs numerically using the finite element method. A parametric study, carried out on 27 beams with different steel cross sections, hollowcore unit depths and spans, is presented. The effective width of the slab is predicted for both the elastic and plastic ranges. 8-node three-dimensional solid elements are used to model the composite beam components. The material non-linearity of all the components is taken into consideration. The non-linear load-slip characteristics of the headed shear stud connectors are included in the analysis. The moment-deflection behaviour of the composite beams, the ultimate moment capacity and the modes of failure are also presented. Finally, the ultimate moment capacity of the beams evaluated using the present FE analysis was compared with the results calculated using the rigid - plastic method.

Experimental Study on Behaviour of Composite Beams with Ribbed Slabs and Unreinforced Web Openings (리브형 슬래브를 갖는 유공합성보의 거동에 관한 실험적 연구)

  • 김창호;박종원;김희구;이창섭;박준용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.989-994
    • /
    • 2000
  • Nine tests to failure are performed on full-scale eight composite beams with unreinforced web opening having ribbed slabs with formed deck which are perpendicular to the steel section and one steel beam. The effects of slab width, reinforcing of stud, moving of rib, moment-shear ratio are studied. At the low M/V ratio, Vierendeel action around the high moment end of the opening is occurred and the large deflection across the opening and transverse cracking are occurred with increasing of applied load. As the M/V ratio increases, the relative deflection across the opening decreases. And at failure, full tensile strain are occurred at bottom T section of steel beam, and concrete crushes at the High Moment End of the opening. With narrow slabs, diagonal tension failure at the high moment end of the opening is occurred. And with wide slabs, rib punch-through failure is occurred near the high moment end of the opening. The implications for design are discussed.

Experiments on the Composite Action of Steel Encased Composite Column (강재매입형 합성기둥의 합성작용에 관한 실험)

  • Jung In Keun;Min Jin;Shim Chang Su;Chung Young Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.485-488
    • /
    • 2004
  • Steel encased composite columns have been used for buildings and piers of bridges. Since column section for pier is relatively larger than that of building columns, economical steel ratio need to be investigated for the required performance. Composite action between concrete and embedded steel sections can be obtained by bonding and friction. However, the behavior. of the column depends on the load introduction mechanism. Compression can be applied to concrete section, steel section and composite section. In this paper, experiments on shear strength of the steel encased composite column were performed to study the effect of confinement by transverse reinforcements, mechanical interlock by holes, and shear connectors. Shear strength obtained from the tests showed considerably higher than the design value. Confinement, mechanical interlock and stud connectors increased the shear strength and these values can be used effectively to obtain composite action of SRC columns.

  • PDF

Design models for predicting the resistance of headed studs in profiled sheeting

  • Vigneri, Valentino;Hicks, Stephen J.;Taras, Andreas;Odenbreit, Christoph
    • Steel and Composite Structures
    • /
    • v.42 no.5
    • /
    • pp.633-647
    • /
    • 2022
  • This paper presents the results from reliability analyses of the current Eurocode 4 (EN 1994-1-1) and AISC 360-16 design models for predicting the resistance of headed stud shear connectors within profiled steel sheeting, when the ribs are oriented transverse to the supporting beam. For comparison purposes, the performance of the alternative "Luxembourg" and "Stuttgart" model were also considered. From an initial database of 611 push-out tests, 269 cases were included in the study, which ensured that the results were valid over a wide range of geometrical and material properties. It was found that the current EN 1994-1-1 design rules deliver a corrected partial safety factor γM* of around 2.0, which is significantly higher than the target value 1.25. Moreover, 179 tests fell within the domain of the concrete-related failure design equation. Notwithstanding this, the EN 1994-1-1 equations provide satisfactory results for re-entrant profiled sheeting. The AISC 360-16 design equation for steel failure covers 263 of the tests in the database and delivers 𝛾M*≈2.0. Conversely, whilst the alternative "Stuttgart" model provides an improvement over the current codes, only a corrected partial safety factor of 𝛾M*=1.47 is achieved. Finally, the alternative "Luxembourg" design model was found to deliver the required target value, with a corrected partial safety factor 𝛾M* between 1.21 and 1.28. Given the fact that the Luxembourg design model is the only model that achieved the target values required by EN 1990, it is recommended as a potential candidate for inclusion within the second generation of Eurocodes.

The Steel Coupling Beam-Wall Connections Strength

  • Park, Wan-Shin;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.

Axial load behavior and stability strength of circular tubed steel reinforced concrete (SRC) columns

  • Yan, Biao;Liu, Jiepeng;Zhou, Xuhong
    • Steel and Composite Structures
    • /
    • v.25 no.5
    • /
    • pp.545-556
    • /
    • 2017
  • The tubed steel reinforced concrete (SRC) column is a composite column in which the outer steel tube is mainly used to provide confinement on the core concrete. This paper presents experimental and analytical studies on the behavior of circular tubed SRC (TSRC) columns subjected to axial compression. Eight circular TSRC columns were tested to investigate the effects of length-to-diameter ratio (L/D) of the specimens, diameter-to-thickness ratio (D/t) of the steel tubes, and use of stud shear connectors on the steel sections. Elastic-plastic analysis on the steel tubes was used to investigate the mechanism of confinement on the core concrete. The test results indicated that the tube confinement increased the strength and deformation capacity for both short and slender columns, and the effects on strength were more pronounced for short columns. A nonlinear finite element (FE) model was developed using ABAQUS, in which the nonlinear material behavior and initial geometric imperfection were included. Good agreement was achieved between the predicted results using the FE model and the test results. The test and FE results were compared with the predicted strengths calculated by Eurocode 4 and the AISC Standard. Based on the analytical results, a new design method for this composite column was proposed.

A Study on the Composition of the Exhibition space unit in the Minimum Art Museum and Small Art Museum Admitting Multifunction (복합기능을 수용하는 소규모 및 극소규모 미술관의 단위전시공간 구성에 관한 연구)

  • 문정민;안우진;고성룡
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.181-187
    • /
    • 2001
  • The art museum plays a role as a cultural space that can solve the cultural desire of people and see a good art works. It is in exhibition space that they personally exchange the feeling between an art work and a viewer in art museum. The types and works - a fiber, a photo, an establishment that needs many places, devices, a video art, and an action art called "performance", cultural art - are shown in small art museum. Moreover, exhibition spaces are modified into the space of another art activities like dancing, music concerts in small art museum because it has no profit space for diverse art activities. And the exhibition the characters of the exhibition space in small art museum. So, it needs to change the characters of the exhibition space in small art museum. Under these background, this stud\ulcorner surveys and analyzes the exhibits, the organization methods, the modified conditions, and the scale of the existing exhibitional space in small art museum. Therefore, the goal of this study is to suggest the composition of the exhibition space unit considering the function and the multifunction in minimum art museum and small art museum.

  • PDF