• 제목/요약/키워드: Stub column

검색결과 100건 처리시간 0.02초

Structural behaviour of stainless steel stub column under axial compression: a FE study

  • Khate, Kevinguto;Patton, M. Longshithung;Marthong, Comingstarful
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1723-1740
    • /
    • 2018
  • This paper presents a Finite Element (FE) study on Lean Duplex Stainless Steel stub column with built-up sections subjected to pure axial compression with column web spacing varied at different position across the column flanges. The thicknesses of the steel sections were from 2 to 7 mm to encompass a range of section slenderness. The aim is to study and compare the strength and deformation capacities as well as the failure modes of the built-up stub columns. The FE results have been compared with the un-factored design strengths predicted through EN1993-1-4 (2006) + A1 (2015) and ASCE8-02 standards, Continuous Strength Method (CSM) and Direct Strength Method (DSM). The results showed that the design rules generally under predict the bearing capacities of the specimens. It's been observed that the CSM method offers improved mean resistance and reduced scatter for both classes of cross-sections (i.e. slender and stocky sections) compared to the EN1993-1-4 (2006) + A1 (2015) and ASCE 8-02 design rules which are known to be conservative for stocky cross-sections.

개량 T-stub 반강접합부의 기초적 연구 (The Basic Study of Semi-Rigid Connections with Reformed T-stubs)

  • 유봉현;이명재;김원기
    • 한국강구조학회 논문집
    • /
    • 제9권4호통권33호
    • /
    • pp.479-487
    • /
    • 1997
  • 강구조 건축물의 접합에서 강접합, 단순접합 이외에 반강접합의 이용이 고려될 수 있다. 반강접합의 장점으로서는 시공의 용이성과 부재의 효율적인 모멘트 분배가 가능하다는 점이다. 본 연구는 기존의 T-stub를 더 많은 회전능력이 생기도록 한 개량 T-stub를 접합요소로 선정하여 중층정도의 건축물에의 적용 가능성을 확인하기 위한 연구의 기초적 단계이다. 연구방법으로서는 개량 T-stub의 역학적 거동을 조사하기 위한 개량 T-stub요소의 인장 및 압축 실험과 개량 T-stub를 이용한 기둥-보 접합부의 단순재하실험이 실시되었다. 실험결과로부터 개량 T-stub의 정성적인 거동을 파악하였고, 개량 T-stub를 이용하면 반강접합으로서의 가능성도 확인하였다.

  • PDF

중심압축력을 받는 일반구조용 강관의 구조성능에 관한 연구 (A Study on the Structural Property of Structural Steel Tubes under Axial Compression)

  • 김종락;이은택;이소연;백기열
    • 한국강구조학회 논문집
    • /
    • 제20권3호
    • /
    • pp.437-444
    • /
    • 2008
  • 현재 국내에 유통되고 있는 강관은 국내산과 수입산이 혼용되고 있으며, 수입산 강관은 가격경쟁 면에서 그 수요가 꾸준히 증가하고 있다. 본 연구는 국내에 유통되고 있는 일반구조용 원형강관 및 비계용 강관에 대하여 소재의 인장시험과 Stub -column 압축시험 및 기둥의 좌굴실험을 통하여 일반구조용 강관의 기계적 성질과 기둥의 강도 및 거동을 파악하고자 한다. 또한 한계상태설계법의 기준식과 복수강도곡선의 적용으로 이론값과 실험값을 비교하여 기계적 요구 성능 및 적합성 여부를 조사하고, 설계기준에 대한 기초자료를 확보하고자 한다. 단주압축 실험결과 관경두께비를 만족하는 시험체의 경우에는 최대내력에 도달한 후 서서히 내력이 저하되는 결과를 나타내었다. 기둥좌굴 실험결과, 최대내력은 일정한 좌굴내력 범위를 나타내었으며 전반적으로 한계상태설계법의 기준곡선에 만족하는 결과를 나타내었다.

Behavior of polygonal concrete-filled steel tubular stub columns under axial loading

  • Zhang, Tao;Ding, Fa-xing;Wang, Liping;Liu, Xue-mei;Jiang, Guo-shuai
    • Steel and Composite Structures
    • /
    • 제28권5호
    • /
    • pp.573-588
    • /
    • 2018
  • The objective of this paper is to investigate the mechanical performances of polygonal concrete-filled circular steel tubular (CFT) stub columns under axial loading through combined experimental and numerical study. A total of 32 specimens were designed to investigate the effect of the concrete strength and steel ratio on the compressive behavior of polygonal CFT stub columns. The ultimate bearing capacity, ductility and confinement effect were analyzed based on the experimental results and the failure modes were discussed in detail. Besides, ABAQUS was adopted to establish the three dimensional FE model. The composite action between the core concrete and steel tube was further discussed and clarified. It was found that the behavior of CFT stub column changes with the change of the cross-section, and the change is continuous. Finally, based on both experimental and numerical results, a unified formula was developed to estimate the ultimate bearing capacity of polygonal CFT stub columns according to the superposition principle with rational simplification. The predicted results showed satisfactory agreement with both experimental and FE results.

Numerical cyclic behavior of T-RBS: A new steel moment connection

  • Ataollahi, Saeed;Banan, Mohammad-Reza;Banan, Mahmoud-Reza
    • Steel and Composite Structures
    • /
    • 제21권6호
    • /
    • pp.1251-1264
    • /
    • 2016
  • After observing relatively poor performance of bolted web-welded flange beam-to-column connections during 1994 Northridge earthquake, various types of connections based on two concepts of: (i) strengthening the connection; and (ii) weakening the beam ends were proposed. Among these modified or newly proposed connections, bolted T-stub connection follows the concept of strengthening. One of the connections with the idea of weakening the beam ends is reduced beam section (RBS). In this paper, finite element simulation is used to study the cyclic behavior of a new proposed connection developed by using a combination of both mentioned concepts. Investigated connections are exterior beam-to-column connections designed to comply with AISC provisions. The results show that moment capacity and dissipated energy of the new proposed connection is almost the same as those computed for a T-stub connection and higher than corresponding values for an RBS connection.

Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns

  • Han, Lin-Hai;Zhao, Xiao-Ling;Tao, Zhong
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.51-74
    • /
    • 2001
  • A series of tests on concrete-filled SHS (Square Hollow Section) stub columns (twenty), columns (eight) and beam-columns (twenty one) were carried out. The main parameters varied in the tests are (1) Confinement factor (${\xi}$) from 1.08 to 5.64, (2) concrete compression strength from 10.7MPa to 36.6MPa, (3) tube width to thickness ratio from 20.5 to 36.5. (4) load eccentricity (e) from 15 mm to 80 mm and (5) column slenderness (${\lambda}$) from 45 to 75. A mechanics model is developed in this paper for concrete-filled SHS stub columns, columns and beam-columns. A unified theory is described where a confinement factor (${\xi}$) is introduced to describe the composite action between the steel tube and filled concrete. The predicted load versus axial strain relationship is in good agreement with stub column test results. Simplified models are derived for section capacities and modulus in different stages of the composite sections. The predicted beam-column strength is compared with that of 331 beam-column tests with a wide range of parameters. A good agreement is obtained. The predicted load versus midspan deflection relationship for beam-columns is in good agreement with test results. A simplified model is developed for calculating the member capacity of concrete-filled SHS columns. Comparisons are made with predicted columns strengths using the existing codes such as LRFD (AISC 1994), AIJ (1997), and EC4 (1996). Simplified interaction curves are derived for concrete-filled beam-columns.

개량 T-stub를 이용한 반강접 골조의 거동 (The Structural Behavior of the Frames with Semi-Rigid Connections Using Reformed T-stubs)

  • 이명재;조원혁
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.339-350
    • /
    • 2000
  • 본 연구의 목적은 개량 T-stub를 이용한 1층 1스팬 골조의 구조적 거동을 파악하고 중층규모의 건축물에 대하여 개량 T-stub의 적용가능성을 확인하기 위한 것이다. 연구방법으로 개량 T-stub 및 기존 T-stub를 이용한 반강접 골조의 반복가력실험을 하였으며 개량 T-stub의 플랜지 두께와 볼트중심거리를 변수로 하여 유한요소해석을 수행하여 그 결과를 실험결과와 비교하였다. 본 연구의 실험 및 해석결과로부터 개량 T-stub의 거동을 정성적으로 파악하고 반강접합부로서의 적용가능성을 확인하였다.

  • PDF

T-stub를 이용한 접합부의 초기강성 평가 (Initial Stiffness Evaluation of T-stub Connection)

  • 이명재
    • 한국강구조학회 논문집
    • /
    • 제18권6호
    • /
    • pp.805-813
    • /
    • 2006
  • 이 논문은 T-stub를 이용한 접합을 반강접이 아닌 강접합의 범주에 두고 그 적용 가능성을 확인하기 위한 초기단계의 연구로서 초기강성에 관한 실험과 유한요소해석을 통하여 T-stub접합과 강접합의 초기강성을 비교하였다. 또한 해석결과를 통하여 T-stub를 이용한 기둥-보 접합부의 초기강성의 영향인자를 조사하였다.

Compressive behavior of concrete-filled square stainless steel tube stub columns

  • Dai, Peng;Yang, Lu;Wang, Jie;Ning, Keyang;Gang, Yi
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.91-106
    • /
    • 2022
  • Concrete-filled square stainless steel tubes (CFSSST), which possess relatively large flexural stiffness, high corrosion resistance and require simple joint configurations and low maintenance cost, have a great potential in constructional applications. Despite that the use of stainless steel may result in high initial cost compared to their conventional carbon steel counterparts, the whole-life cost of CFSSST is however considered to be lower, which offers a competitive choice in engineering practice. In this paper, a comprehensive experimental and numerical program on 24 CFSSST stub column specimens, including 3 austenitic and 3 duplex stainless steel square hollow section (SHS) stub columns and 9 austenitic and 9 duplex CFSSST stub columns, has been carried out. Finite element (FE) models were developed to be used in parametric analysis to investigate the influence of the tube thickness and concrete strength on the ultimate capacities more accurately. Comparisons of the experimental and numerical results with the predictions made by design guides ACI 318, ANSI/AISC 360, Eurocode 4 and GB 50936 have been performed. It was found that these design methods generally give conservative predictions to the ultimate capacities of CFSSST stub columns. Improved calculation methods, developed based on the Continuous Strength Method, have been proposed to provide more accurate estimations of the ultimate resistances of CFSSST stub columns. The suitability of these proposals has been validated by comparison with the test results, where a good agreement between the predictions and the test results have been achieved.

컬럼-트리 형식 철골모멘트 접합부의 모델링 변수제안 (Modeling Parameters for Column-Tree Type Steel Beam-Column Connections)

  • 안희태;김태완;유은종
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.59-68
    • /
    • 2023
  • The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.