• 제목/요약/키워드: Structure-borne-noise

검색결과 238건 처리시간 0.028초

EXPERIMENTAL IDENTIFICATION ON A GEAR WHINE NOISE IN THE AXLE SYSTEM OF A PASSENGER VAN

  • Kim, S.J.;Lee, S.K.
    • International Journal of Automotive Technology
    • /
    • 제8권1호
    • /
    • pp.75-82
    • /
    • 2007
  • This paper presents practical work on the reduction of gear whine noise. In order to identify the source of the gear whine noise, transfer paths are searched and analyzed by operational deflection shape analysis and experimental modal analysis. It was found that gear whine noise has an air-borne noise path instead of structure-borne noise path. The main sources of air-borne noise were the two global modes caused by the resonance of an axle system. These modes created a vibro-acoustic noise problem. Vibro-acoustic noise can be reduced by controlling the vibration of the noise source. The vibration of noise source is controlled by the modification of structure to avoid the resonance or to reduce the excitation force. In the study, the excitation force of the axle system is attenuated by changing the tooth profile of the hypoid gear. The modification of the tooth profile yields a reduction of transmission error, which is correlated to the gear whine noise. Finally, whine noise is reduced by 10 dBA.

판넬기여도와 설계민감도를 이용한 구조기인소음 설계프로세스 (A Design Process for Structural Borne Noise using Panel Contribution and Design Sensitivity)

  • 김효식;김헌희;조효진;윤성호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.806-811
    • /
    • 2007
  • In this study, we propose a more systematic design process for the structure-borne noise. The proposed way consists of 4 steps: Problem definition, Cause analysis, Development of counter-measure and Validation. Especially, we improved the second step: Cause analysis. According to the PCA(Panel Contribution Analysis), a reduction in vibration of the panels of which panel contribution is positive and larger, results in a reduction in structure-borne noise. We have, however, met the case in which the concept of PCA is no valid in a few vehicle tests. In order to understand this phenomenon, we compared the major panels selected by PCA with the one chosen by DSA(Design Sensitivity Analysis). After investigating the difference between the two results, a more improved process is suggested. The proposed one for the second step in the design process consists of not only the previous way: PCA with deformation analysis results but also DSA. It is finally validated that the proposed design process decreases the sound pressure of the concerned noise transfer function more than 3.5 dB.

  • PDF

차량용 에어컨 부밍 소음의 전달 특성에 관한 연구 (A Study on Transfer Characteristics of Vehicle Air-conditioner Booming noise)

  • 임승택;주경훈;안휴남;박영덕;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.476-481
    • /
    • 2013
  • Transfer path analysis(TPA) and operational deflection shape(ODS) have been widely utilized to analyze the characteristics of noise. TPA enables to decompose a noise into air-borne and structure-borne noises then estimate the path contribution of noise. ODS enables to analyze a moving shape and direction of interest components at a particular frequency. In this paper, TPA and ODS are applied to transfer paths of air-conditioner booming noise in a vehicle to reduce noise level, then a fixture is mounted it's path for distributing the high portion path contribution to the low portion path contribution. Through this experiment, the reduction of sound pressure level in air-conditioner booming noise is observed. Thereafter, TPA is again employed to verify the results of contribution.

  • PDF

선체로 전달되는 해수 이송 배관의 진동 저감 분석 (Analysis for Reducing Vibration Transmitted from the Sea-Water Conveying Pipe to the Hull)

  • 한형석;박미유;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.145-151
    • /
    • 2008
  • URN(Underwater Radiated Noise) is one of the important performances of the battle ship related to the stealth. The main source of the URN is the structure-borne noise on the hull. And the pipe vibration transmitted to the hull is the main source of the structure-borne noise when the speed of the ship is lower than CIS(Cavitation Inception Speed). In this paper, the vibration isolator(rubber mount) for the pipe system is described in order to reduce the structure-borne noise transmitted to the hull. The vibrations on the sea-water conveying pipes and their supports are measured in order to know how much vibration occurs on those positions. Based on these test results, the improved design of the rubber mount is suggested by the parametric study and is verified numerically with the pipe and hull model.

  • PDF

공기 압축기 고체음 저감에 대한 연구 (A study on the reduction of structure-borne noise from air condensing compressor)

  • 정성진;최수현;조현동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.407-410
    • /
    • 2007
  • In the ship-building industry, reciprocating air condensing compressors are usually applied in the HVAC system because of their good performance, efficiency and the convenience. However, the inertia force and pressure fluctuation of the compressor may generate unexpected excessive noise and vibration in the near by cabins. This paper presents a theoretical background and appropriate countermeasures on the reduction of structure-borne noise from the compressors.

  • PDF

비드를 이용한 평판의 구조소음 저감 (Structure-borne Noise Reduction of Plate using bead)

  • 김호산;심현진;강귀현;정동현;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.269-274
    • /
    • 2007
  • With the importance of comfortable environment, research about noise reduction of construction is consisting much. If construction receives the input force, noise will be generated thereby. We must predict vibration and noise characteristic to reduce structured borne noise, and construction which become a basis of such research is plate. In order to predict the radiating noise from the vibrating surface. It is required to know the velocity distribution of vibration surface exactly. It is good to use bead for reducing vibration and noise of plate. In this study, we have analyzed structure-borne noise of plate with bead and compare with plate that there is no bead about equal exciting force.

  • PDF

전달경로해석법에 의한 진동하는 판넬의 방사 소음 예측 (Prediction Of Vibrating Panel's Radiating Noise By Transfer Path Analysis)

  • 오재응;이선훈;정운창;김진수;이유엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.292-293
    • /
    • 2014
  • Transfer Path Analysis is technique predicting transmitted energy through each path. Using the Transfer Path Analysis, structure-borne noise and air-borne noise can be predicted from the system. In this study, however, the Transfer Path Analysis to target only the structure-borne noise due to the noise radiated from the vibrating panel was performed. Predicted noise by the Transfer Path Analysis and measured noise by the experiment were a high correlation. We confirmed the validity of the Transfer Path Analysis through the analysis of these results, showed how to apply the Transfer Path Analysis.

  • PDF

승용차 대시부의 구조 방사 효율 저감 방법 제안 (A Suggestion of Method to reduce the Radiation Efficiency of Dash Panel of a Passenger Car)

  • 김영기;강연준;안옥균;기지현;최윤봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.268-272
    • /
    • 2002
  • A study to determine the structure-borne noise radiated by a dash panel of a real car is performed by using the finite element method (FEM) and the boundary element method (BEM). The radiation efficiency is used to estimate the structure-borne noise radiated by a dash panel. The curved surfaces of a dash panel change the radiation efficiency. Experimental results of radiation efficiency of a simple rectangular plate and a dash panel show good agreements with the simulation results.

  • PDF

서울지하철 4호선 R250m 인접구간 도시개발정비에 따른 궤도방진설계 (Case of track improvement in the area of redevelopment project surrounding around Seoul Metro Lin.4(R=250m))

  • 공선용;김상진;양태경;백찬호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.324-329
    • /
    • 2010
  • The surroundings around subway are becoming more lively for project of CBD (an redevelopment project), however vibrations which are made through passing train cold spread buildings around. The structure-borne noise could be generated at the same time that makes people including developers and th citizens have negative viewpoint on railway. Especially, Seoul Metro 1-4 lines ar built alongside the road nearby houses and business district. That could make plenty of public resentments because of the structure-borne noise. Seoul Metro should make active alternative plans for their future urban environment projects which will be conducted. The case was Railway Facility which were conducted to minimize structure-borne noise from sharp curved track section (4 line, Sinyongsan~Ichon, R 250m). The section is adjacent to house district as near as 6.6m related with pusing international city project, the 4th urban environment project around international building, near Yongsan station. The interval of sleepers would be downsized in half with breaking existing case, and pad stiffness is reduced 4 ton from 10 ton. That makes structure-borne noise minimized because of vibrations are lowered about 19.1-23.0db. The structure above has remained for a year and a half from October, 2008, and had not any trouble to perform excellence with 80million ton rail accumulated tonnage.

  • PDF

고무마운트를 통한 장비의 고체음 전달에 관한 연구 (Study on the Structure-borne Sound Transmission of a Machine through Rubber Mounts)

  • 김봉기;김재승;김현실;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.655-660
    • /
    • 2000
  • Machines on board a ship are mounted on decks and transmit its structure-borne sound to the deck through resilient mounts. To predict the ship noise generated by the structure-borne sound of the machine, It is necessary to estimate the vibration level of the base structure. In this paper, a simple dynamic model is considered for vibration isolation systems consisting of a source, an isolator, and a base structure. The high frequency mobilities of the simple base structure are reviewed and wave effects in the mount are discussed in relation to isolation performance.

  • PDF