• Title/Summary/Keyword: Structure load

Search Result 4,706, Processing Time 0.032 seconds

Effect of Span-to-Depth Ratio on Behavior and Capacity in Composite Structure of Sandwich System (샌드위치식 복합구조체의 셀(Cell)형상비가 거동과 성능에 미치는 영향)

  • 정연주;정광회;김병석;박성수;황일선
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.73-78
    • /
    • 2000
  • This paper describes the effect of span-to-depth ratio, which describes aspect of cell formed with top diaphragm steel plate, on capacity in composite steel-concrete structure of sandwich system. The span-to-depth ratio \ulcorner load-carrying mechanism and load-distribution capacity of structure. Therefore, stress levels of members and load-resis\ulcorner of system vary according to span-depth ratio. In this study, numerical nonlinear analysis was performed to various ratio for two types(MA, MB) composite structure of sandwich system to analyze the influence of span-to-depth ratio or, behavior. The difference of load-carrying mechanism and stress of members results from analysis results, then bas\ulcorner differences, the effects of span-to-depth ratio on shear capacity, flexural capacity and load-resistance capacity were analyze effects on failure mode and ductility were briefly. As a results of this study, as span-to-depth ratio increases, \ulcorner bottom steel plate and concrete lower. This implies an increase in effective flexural and shear capacity. Therefore lo\ulcorner capacity of structure improves as span-to-depth ratio increases, Especially, the effect is greate in shear than flexural span-to-depth ratio increases, this difference between flexural and shear capacity may change failure mode and ductility. span-to-depth ratio increases capacity increases more than flexural capacity, we should expect that structural behavior mode gradually change from shear to flexural and ductility of structure gradually improves.

  • PDF

Comparison of finite element analysis with wind tunnel test on stability of a container crane (컨테이너 크레인의 안정성에 대한 풍동실험과 유한요소해석의 비교)

  • Han, D.S.;Lee, S.W.;Han, G.J.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.29-35
    • /
    • 2008
  • This study is conducted to provide the proper analysis method to evaluate the stability of a container crane under wind load. Two analysis method, namely structure analysis and fluid-structure interaction, are adopted to evaluate the stability of a container crane in this investigation. To evaluate the effect of wind load on the stability of the crane, 50-ton class container crane widely used in container terminals is adopted for analysis model and 19-values are considered for wind direction as design parameter. We conduct structure analysis and fluid-structure interaction for a container crane with respect to the wind direction using ANSYS and CFX. Then we compare the uplift forces yielded from two analysis with it yielded from wind tunnel test. The results are as follows: 1) A correlation coefficient between structure analysis and wind tunnel test is lower than 0.65(as $0.29{\sim}0.57$), but between fluid-structure interaction and wind tunnel test is higher than 0.65(as $0.78{\sim}0.86$). 2) There is low correlation between structure analysis and wind tunnel test but very high correlation between fluid-structure interaction and wind tunnel test.

  • PDF

Strength Method Using Pre-flexed Members for the Corner of Underground Box Structures under Additional Surface Load (추가 상재하중을 받는 지중박스구조물의 우각부에 대한 프리플렉스 부재를 이용한 보강공법)

  • Chung, Jee Seung;Lee, Jin Hyuk;Kim, Ki Am
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.102-108
    • /
    • 2016
  • This paper presents a new strength method of underground box structures under additional surface load. An L-bracing using pre-flexed steel member threads called the "Pre-flex strength method" is used to improve capacity of the RC box structure under earth pressure due to additional surface load. The pre-flexed steel member is fixed the top and bottom of the structure after chemical anchor was installed by drilling hole on the box structure. The structural performance was evaluated analytically. 3 types of underground RC box structure were used; $2.0m{\times}2.0m$, $3.0m{\times}3.0m$ and $4.0m{\times}4.0m$. For the performance evaluation, structure analysis were performed on moment and shear resisting structures with and without pre-flex strength method. Numerical results confirmed that the proposed strength member system installed on underground RC box structures enhanced the strength capacity. The feasible region of the proposed pre-flex strength method in accordance with the earth pressure due to additional surface depth was evaluated.

Design of sensing element for 3-component load cell using parallel plate structure (병렬판구조를 이용한 3분력 로드셀 감지부의 설계)

  • Kim, Gap-Sun;Kang, Dae-Im;Jeong, Su-Yeon;Joo, Jin-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1871-1884
    • /
    • 1997
  • This paper describes the design process of a 3-component load cell with a multiple parallel plate structure which may be used to measure transverse forces and twisting moment simultaneously. Also we have derived equations to predict the bending strains on the surface of the beams in the multiple parallel plate structure under transverse force or twisting moment. It reveals that the bending strains calculated from the derived equations are in good agreement with the results from finite element analysis and experiment. Also we have evaluated the rated output and interference error of each component, which can be efficiently used to design a 3-component load cell with a multiple parallel plate structure.

Study on the Structural Optimization based on Equivalent Static Load under Dynamic Load (동하중을 받는 구조물의 등가정하중 기반 구조 최적화 연구)

  • Kim, Hyun-Gi;Kim, Euiyoung;Cho, Maenghyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.421-427
    • /
    • 2014
  • Most of the structure of the real world is influenced under dynamic loads. However, when structure analysis and the structural optimization is performed, it is assumed that the static load acts on structure. When considering the actual load of dynamic loads in order to take into account a variety of loads, computational resources and time becomes a big burden in terms of cost. However, considering only the simple static load condition is not preferable for structural safety. For this reason, a lot of studies have been conducted trying to compensate this trouble by applying weight factor or replacing dynamic load with the equivalent static load. In this study, structural optimization techniques for structures under dynamic loads is proposed by applying the equivalent static load. From previous study, after determining the positions of equivalent static load based on primary degrees of freedom, the equivalent static load is calculated through the optimization process. In this process, the equivalent static load optimization of previous research is complemented by adding constraints to avoid excessively large load extraction. In numerical examples, dynamic load is applied to the truss structure and the plate. Then, the reliability of the proposed optimization technique is verified by carrying out size optimization with the equivalent static load.

Static stability and of symmetric and sigmoid functionally graded beam under variable axial load

  • Melaibari, Ammar;Khoshaim, Ahmed B.;Mohamed, Salwa A.;Eltaher, Mohamed A.
    • Steel and Composite Structures
    • /
    • v.35 no.5
    • /
    • pp.671-685
    • /
    • 2020
  • This manuscript presents impacts of gradation of material functions and axial load functions on critical buckling loads and mode shapes of functionally graded (FG) thin and thick beams by using higher order shear deformation theory, for the first time. Volume fractions of metal and ceramic materials are assumed to be distributed through a beam thickness by both sigmoid law and symmetric power functions. Ceramic-metal-ceramic (CMC) and metal-ceramic-metal (MCM) symmetric distributions are proposed relative to mid-plane of the beam structure. The axial compressive load is depicted by constant, linear, and parabolic continuous functions through the axial direction. The equilibrium governing equations are derived by using Hamilton's principles. Numerical differential quadrature method (DQM) is developed to discretize the spatial domain and covert the governing variable coefficients differential equations and boundary conditions to system of algebraic equations. Algebraic equations are formed as a generalized matrix eigenvalue problem, that will be solved to get eigenvalues (buckling loads) and eigenvectors (mode shapes). The proposed model is verified with respectable published work. Numerical results depict influences of gradation function, gradation parameter, axial load function, slenderness ratio and boundary conditions on critical buckling loads and mode-shapes of FG beam structure. It is found that gradation types have different effects on the critical buckling. The proposed model can be effective in analysis and design of structure beam element subject to distributed axial compressive load, such as, spacecraft, nuclear structure, and naval structure.

The Effect of Fiber Volume Fraction Non-uniformity through Thickness Direction on the Torsional Buckling Load of Cylindrical Composite Lattice Structure (두께방향 섬유체적비 불균일이 원통형 복합재 격자 구조의 비틀림 좌굴 하중에 미치는 영향)

  • Min-Hyeok Jeon;Hyun-Jun Cho;Yeon-Ju Kim;Mi-Yeon Lee;In-Gul Kim
    • Composites Research
    • /
    • v.36 no.2
    • /
    • pp.80-85
    • /
    • 2023
  • A cylindrical composite lattice structure is manufactured by filament winding. The distribution of nonuniform fiber volume fraction induced by the manufacturing process can be observed. The stiffness and buckling characteristics can be influenced by non-uniform fiber volume fraction. In this paper, the effect of non-uniform fiber volume fraction through thickness direction on the torsional buckling load of the cylindrical composite lattice structure was examined. The stiffness variation induced by the non-uniform fiber volume fraction was applied to the finite element model, and buckling analysis was performed. The variations of buckling load with variations of fiber volume fraction were compared. The non-uniform fiber volume fraction reduced the torsional buckling load of the composite lattice structure.

Load Sharing in Hierarchical Cell Structure for High Speed Downlink Packet Transmission (하향링크 고속 패킷 전송을 위한 계층적 셀 구조에서의 기지국간 부하 분배)

  • Jeong, Dong-Geun;Jeon, Wha-Sook
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.5
    • /
    • pp.466-472
    • /
    • 2002
  • We investigate the load sharing problem between the umbrella cell and the overlaid tells in hierarchical cell structure. A load sharing strategy is proposed and its performance is evaluated by simulation when it is used for transmission of the mobile Internet traffic using the High Speed Downlink Packet Access scheme. The results show that, with the proposed strategy, the microcell backs well the overlaid picocells up, especially when a specific picocell cluster suffers unusual heavy load condition. By using the strategy, we can reduce the installation cost, otherwise needed for increasing the system capacity of every picocell cluster to cope with the unusual heavy load.

LDO Regulator with Improved Fast Response Characteristics and Push-Pull Detection Structure (Push-Pull Detection 구조 및 빠른 응답 특성을 갖는 LDO 레귤레이터)

  • Lee, Joo-Young
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.201-205
    • /
    • 2021
  • In this paper present Low Drop-Out (LDO) regulator that improved load transient characteristics due to the push-pull detection structure. The response characteristic of the voltage delta value is improved due to the proposed push-pull sensing circuit structure between the input terminal of the LDO regulator pass transistor and the output terminal of the internal error amplifier. Voltage value has improved load transient characteristics than conventional LDO regulator. Compared to the conventional LDO regulator, it has an improved response speed of approximately 244 ns at rising time and approximately 90 ns at falling time. The proposed circuit was simulated by the samsung 0.13um process using Cadence's Specter and Virtuoso simulator.

LDO Regulator with Improved Regulation Characteristics and Feedback Voltage Buffer Structure (Feedback Buffer 구조 및 향상된 Regulation 특성을 갖는 LDO regulator)

  • Jung, Jun-Mo;Park, Tae-Ryong
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.462-467
    • /
    • 2022
  • The feedback buffer structure is proposed to alleviate the overshoot and undershoot phenomenon and the regulation of the output voltage. The conventional LDO regulator undergoes a regulation voltage change caused by a constant load current change. An LDO regulator with a feedback voltage sensing structure operates in the input voltage range of 3.3 to 4.5 V and has a load current of up to 150 mA at output voltage of 3 V. According to the simulation results, a regulation value of 6.2 mV was ensured when the load current uniformly changed to 150 mA.