• 제목/요약/키워드: Structural steel

검색결과 5,845건 처리시간 0.025초

Structural stability of fire-resistant steel (FR490) H-section columns at elevated temperatures

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • 제17권1호
    • /
    • pp.105-121
    • /
    • 2014
  • A fundamental limitation of steel structures is the decrease in their load-bearing capacity at high temperatures in fire situations such that structural members may require some additional treatment for fire resistance. In this regard, this paper evaluates the structural stability of fire-resistant steel, introduced in the late 1999s, through tensile coupon tests and proposes some experimental equations for the yield stress, the elastic modulus, and specific heat. The surface temperature, deflection, and maximum stress of fire-resistant steel H-section columns were calculated using their own mechanical and thermal properties. According to a comparison of mechanical properties between fire-resistant steel and Eurocode 3, the former outperformed the latter, and based on a comparison of structural performance between fire-resistant steel and ordinary structural steel of equivalent mechanical properties at room temperature, the former had greater structural stability than the latter through $900^{\circ}C$.

Structural Properties of Steel-glulam Composite Column

  • Jang, Sang-Sik;Kim, Yun-Hui;Shin, Il-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권5호
    • /
    • pp.399-404
    • /
    • 2010
  • A new green home designed to save money while at the same time saving the environment with some of the finest green features available in the market. Composite column composed of structural steel and structural glued laminated timber is avery Eco-friendly building products for design building because that use recycled or second hand. For compare to compressive strength of structural glued laminated timber (glulam), structural steel, and composite column (steel-glulam), tested compressive strength of each specimen. 1) structural glued laminated timber : Theoretical compressive strength is 151.6 kN similar to elastic limits. 2) structural steel (H type) : Theoretical compressive strength is 148.2 kN little under the elastic limits. 3) structural steel (D type) : Theoretical compressive strength is 147.3 kN upper than the elastic limits. 4) composite column : Actual elastic limits are about 600 kN. Result in, composite column improve compressive strength of Structural steel column and provide structural stability of the building.

교량용 강ㆍ콘크리트 합성 바닥판의 실험적 구조성능 (An Experimental Structural Performance of Steel Concrete Hybrid Deck for Bridge)

  • 정연주;정광회;구현본;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.524-529
    • /
    • 2003
  • This paper presents a experimental structural performance of steel-concrete hybrid bridge deck, which has studs to connect steel plate and concrete and T beam to improve structural performance, by steel plate shape, studs and load location. It proved that steel-concrete hybrid deck has a high structural performance and lightweight due to the efficient use of steel plate as a structural member, which has only used as formwork. In failure mode, few specimen failed at punching shear and many specimen at concrete crushing, therefore proved it has sufficient stability to punching shear which is the most frequent damage of bridge deck. Steel-concrete hybrid deck of plane steel plate has a high structural performance, and that of corrugated steel plate has a high reduction of weight.

  • PDF

Evaluating high performance steel tube-framed diagrid for high-rise buildings

  • Lee, Dongkyu;Ha, Taehyu;Jung, Miyoung;Kim, Jinho
    • Steel and Composite Structures
    • /
    • 제16권3호
    • /
    • pp.289-303
    • /
    • 2014
  • In recent, development of construction and design technology gives taller, larger and heavier steel framed structures. With the tendency of increasing high-rise building, this study is strongly related to structural system, one of significant components in structural design. This study presents an innovative structural system, with high performance steel material, diagrid. Its detail, structural analysis, and structural experiments are all included for the development of new structures.

An investigation into structural behaviour of modular steel scaffolds

  • Yu, W.K.
    • Steel and Composite Structures
    • /
    • 제4권3호
    • /
    • pp.211-226
    • /
    • 2004
  • This paper presents a study on the structural behaviour of modular steel scaffolds through both experimental and numerical investigations. Three one-storey and three two-storey modular steel scaffolds were built and tested to failure in order to examine the structural behaviour of typical modular steel scaffolds. Details of the tests and their test results were presented in this paper. Moreover, an advanced non-linear analysis method was employed to evaluate the load carrying capacities of these scaffolds under different support conditions. Comparisons between the experimental and the numerical results on the structural behaviour of these modular steel scaffolds were also presented. Moreover, the restraining effects of external supports in practical situations were also studied through finite element methods. The predicted load carrying capacities and deformations at failure of these models under partially restrained conditions were found to be close to the experimental results. A codified design method for column buckling with modified slenderness ratios was adopted for practical design of modular steel scaffolds.

Cyclic tests on bolted steel and composite double-sided beam-to-column joints

  • Dubina, Dan;Ciutina, Adrian Liviu;Stratan, Aurel
    • Steel and Composite Structures
    • /
    • 제2권2호
    • /
    • pp.147-160
    • /
    • 2002
  • This paper summarises results of the research performed at the Department of Steel Structures and Structural Mechanics from the "Politehnica" University of Timisoara, Romania, in order to evaluate the performance of beam-to-column extended end plate connections for steel and composite joints. It comprises laboratory tests on steel and composite joints, and numerical modelling of joints, based on tests. Tested joints are double-sided, with structural elements realised of welded steel sections. The columns are of cruciform cross-section, while the beams are of I section. Both monotonic and cyclic loading, symmetrically and antisymmetrically, has been applied. On the basis of tested joints, a refined computer model has been calibrated using a special connection element of the computer code DRAIN 2DX. In this way, a static/dynamic structural analysis of framed structures with real characteristics of the beam to column joints is possible.

강재 단순보 단부에 근접한 개구부의 구조성능에 관한 실험적 연구 (An Experimental Study on the Structural Performance of Openings at End Steel Beams)

  • 한동호;윤성기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.138-145
    • /
    • 2020
  • 본 연구는 강재 단순보의 유공보 시스템에서 개구부를 지지점 에 근접한 위치에 설치하는 경우에 대하여 구조성능을 파악하고자 실험을 실시하였다. 또한 수직·수평 강판을 이용한 개구부 보강에 대하여도 실험을 통하여 구조성능을 파악하였다. 강재 단순보에서 개구부가 지지점에 근접한 위치인 강재보 높이의 절반(D/2)인 경우에 강재보 높이(D)인 경우보다 적절한 개구부 위치인 것을 알 수 있었다. 또한 보강방법으로는 수직강판 보강보다는 수평강판 보강이 보강효과가 크며, 개구부와 강판의 간격이 없는 것이 구조성능이 더 큰 결과를 얻을 수 있었다.

건설용 강재개발 및 용접기술동향 (Development of Structural Steel and Trend of Welding Technology)

  • 김성진;정홍철
    • Journal of Welding and Joining
    • /
    • 제34권1호
    • /
    • pp.7-20
    • /
    • 2016
  • A brief overview is given of the development of various structural steels and their welding application technology. Firstly, the general characteristics and welding performance of structural steels used in architecture and bridge are introduced. For safety against earthquakes or strong wind, and for highly efficient welding in high-rise building constructions, ultra high strength steel with tensile strength over 800 MPa or high HAZ toughness steel plates under high heat input welding have been developed. In particular, efficient welding technology ensuring high resistance to cold and hot cracking of ultra high strength steel is reviewed in the present paper. Secondly, various coated steels used mainly for outer part in construction are briefly discussed. Moreover, a major drawback of coated steel during welding operation, and several solutions to overcome such technical problem are proposed. It is hoped that this review paper can lead to significant academic contributions and provide readers interested in the structural steels with useful welding technology.

초기재령 강섬유보강 철근콘크리트 보의 구조성능 평가 및 개선 (Improvement and Evaluation of Structural Performance of Steel Fiber Reinforced Concrete Beams Using Early Age Concrete)

  • 하기주;신종학;곽윤근;권칠성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.129-137
    • /
    • 1999
  • Reinforced concrete structures using early age concrete were result in the degradation of structural performance due to crack, overload, unexpected vibration and impact load. It demands urgently that reinforced concrete structure using early age concrete should be improved the serviceability and structural performance with the application of new fiber materials. Therefore specimens, designed by the test varibles, such as with or without stirrup and percent of steel fiber incorporated, were constructed and tested to evaluate and develop the structural performance of reinforced steel fiber concrete beam. Based on the test results reported in this study, the following conclusions are made. Specimens, designed by the over 0.75% of steel fiber incorporated, were showed the ductile behavior and failed slowly with flexure and flexure-shear. Comparing with the load-displacement relationship of specimen BSS, designed by the recommendations of the Ministry of Construction and Transportation, reinforced steel fiber concrete beam using early age concrete, over 0.75% of steel fiber incorporated, gets enough load carrying capacity and ductility. Increasing the percent of steel fiber incorporated(0.25~2.0%), the ultimate shear stress of each specimen were increased 12~40% than that of control specimen SSS.

  • PDF

강재 경계요소를 갖는 콘크리트 벽체의 내진 성능 (Seismic Response of Concrete Walls with Steel Boundary Elements)

  • 조순호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.290-297
    • /
    • 2000
  • A new form of construction utilizing structural steel as the boundary elements in ductile flexural concrete walls is proposed to solve the bar congestion problems associated with such a heavily reinforced region. Two wall specimens containing rectangular hollow structural sections(HSS) and channels at their ends respectively were constructed rectangular hollow structural sections(HSS) and channels ar their ends respectively were constructed and tested under reversed cyclic loading to evaluate the construction process as well as the structural performance. One companion standard reinforced concrete wall specimen was also tested for the comparison purpose At an Initial stage all three specimens were carefully detailed to have the approximately same flexural capacity. Analysis and comparison of test results indicated that the reversed cyclic responses of the three walls showed similar hysteretic properties but in those with steel boundaries local bucking of the corresponding steel elements following significant yielding of structural steel was prominent. Design procedures considering local instability of the structural steel elements and the interaction between steel chord and concrete web members in such composite walls are presented.

  • PDF